Experimental Investigations of Energy Dependent Gamma-Neutron Noise [Slides]
PFUNS was an integral experiment performed at the National Criticality Experiments Research Center (NCERC) by Los Alamos National Laboratory in 2024.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
PFUNS was an integral experiment performed at the National Criticality Experiments Research Center (NCERC) by Los Alamos National Laboratory in 2024.
Modeling approach has significant impact on expected neutron spectral flux. Presence of water in Unit 3 greatly reduces neutron signal. Neutron flux from Homogeneous and Lattice models behaved more similarly as opposed to Layered model.
The 1FRAME (1F Fuel Retrieval and Monitoring Experiments) project includes collaborative research and development in the area of neutron detection, analysis, and simulations for fuel debris removal at Fukushima Daiichi nuclear power station. Technical advances are needed in all three focus areas to provide technical recommendations on a course of action for fuel debris removal. This work is part of collaborative research and development efforts between the US, Japan, and France.
The objective of this research was to create an algorithm to provide an estimate of special nuclear material (SNM) mass using only neutron count rate data from a Radioisotope Identification Device (RIID), rather than using time-correlated data from a neutron multiplicity counter. To meet this objective neutron count rate measurements of a 252 Cf source were taken at varying distances with an ORTEC Detective X, FLIR Identifinder 2, and an ORTEC RADEAGLET-R. An algorithm was created to estimate mass of SNM utilizing the singles rate equation and the measured absolute efficiency curves.
Some Radioisotope Identification Devices (RIIDs) have a low efficiency neutron detector that can provide a neutron singles counting rate along with the primary gamma spectra that can be used to identify a radioisotope. When we know absolute efficiency, other characteristics of a radioisotope can be estimated such as mass or source strength when accompanied by the identity of the isotope and other observable variables. This study focuses on characterizing and comparing the absolute neutron efficiencies of some commonly used RIIDs: the ORTEC Detective X, ORTEC RADEAGLET-R, and FLIR IDentifinder 2.
Modeling approach has significant impact on expected neutron spectral flux. Presence of water in Unit 3 greatly reduces neutron signal. Neutron flux from Homogeneous and Lattice models behaved more similarly as opposed to Layered model.
This presentation begins with a flattop description then touches on current benchmark model, path to reevaluation, planned revision configurations and ends with conclusions.
This presentation discusses the first campaign on the Deimos platform. There was planned for 3 configurations and got 6. In process of writing ICSBEP evaluation with Section 1: to external review end of FY25 and the Full evaluation to TRG: FY27.
Useful method for high-precision measurements of integral cross section in various samples. The availability of benchmark-quality effective delayed neutron fraction (ßeff) values for nuclear data and code validation remains limited.
Criticality monitoring is integral to fuel debris removal during deactivation & decommissioning. This is challenging when fuel debris is not well characterized, i.e. the Fukushima-Daiichi Nuclear Power Station (1F) site.
Reactor noise is a nondestructive approach to measure neutron/gamma fluctuations. Extract kinetic parameters such the prompt neutron decay constant (a). Used in applications such as safeguards and reactor physics. This work address the impact on precision from frequency domain analysis methodology.
Abstract not provided.
The purpose of this presentation is to provide NCS with a clear path to reduce NCERC vault footprint for over 1,000 ZPPR 3PANN fuel plates.
VALID continues to serve as a library of high-quality models used for evaluating SCALE and nuclear data. Large number of cases are in the pipeline. Online repository is available for use. Future plans include simplifying the process for adding cases, including additional models outside the ICSBEP Handbook (HTC models, DNCSH models, International Handbook of Evaluated Reactor Physics Benchmark Experiments [IRPhE], SINBAD, etc.), and increasing the availability of models and results for external users.
The ENDF/B-VIII.1 evaluation library has seen a great growth in the thermal neutron scattering sub-library. The SCALE code system has traditionally approached CE transport by assuming that the CE library on disk represented the fully expanded cumulative probability distributions, conditional on exiting angle and marginal on exiting energy. While this is a complete description of the data, it comes at the potential cost of large amounts of on-disk storage. This approach was strained by several TSL files in ENDF/B-VIII.1, such as graphite, which contained data for a large number of Bragg edges. In the fully expanded probability distributions, this was found to be a disproportionately large fraction of the SCALE CE library.
This presentation goes over membership of ANS-8 subcommittee (SC) and WGs. Additionally discussed is ANS-8 SC and NCSCC ballots for ANS-8 standards since the last meeting, ANS-8 business, ISO TC85/SC5/WG8 September Meeting – quick summary. Working Group Chair Reports, ISO TC85/SC5/WG8 “Nuclear Criticality Safety” committee, and How to volunteer/participate.
This presentation covers motivation and Introduction, experimental Data Considered in the Analysis, R-Matrix Analysis and Model Details and Selection of Critical Benchmark Experiments.
The hybrid method stemmed from a need to develop a way for CLUTCH to generate more accurate sensitivity coefficients for systems with large fissionable reflectors (i.e., HMF-028-001). For additional systems, the method has been shown to generate accurate sensitivity coefficients for a variety of systems with different fissile nuclides, fissile forms, and neutron energy spectra.