Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MOLDING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Qualification of 3-D Printed Mortar With Electrical Conductivity Measurements

Additive manufacturing (AM) or 3D printing of concrete allows for construction of arbitrary shape structures without a mold. Since reproducibility of 3D printed concrete is lower than that of conventional fabrication, each 3D printed structure should be monitored for proper curing. Conventional qualification of concrete is based on several tests, including destructive compressive strength measurements. Because a structure is 3-D printed layer-by-layer, the surfaces of AM concrete structures have significant surface roughness. This limits the applicability of conventional nondestructive testing methods. We investigated qualification of 3D printed mortar by monitoring curing with nondestructive electrical conductivity measurements. Bulk resistance of concrete was extracted from electrochemical impedance spectroscopy (EIS measurements made using custom flexible self-adhesive electrodes, which contour to rough surfaces. We show that bulk resistivity of concrete increases linearly with time. This allows for developing a calibration curve for compressive strength lookup from nondestructive electrical conductivity measurements. Conductivity measurements also allow for estimation of formation factor, which is an indicator of mortar permeability.

36 MATERIALS SCIENCE↗

New alnico magnets fabricated from pre-alloyed gas-atomized powder through diverse consolidation techniques

Fine Alnico 8 spherical powder produced by gas atomization was consolidated through hot pressing (HP), hot isostatic pressing (HIP), and compression molding and subsequent sintering (CMS) techniques. The effects of different fabrication techniques and processing parameters on microstructure and magnetic properties were analyzed and compared. The HP, HIP, and CMS magnets exhibited different features in microstructures and magnetic properties. Magnetically annealed at 840°C for 10 min and subsequently tempered at 650°C for 5h and 580°C for 15h, the HIP sample achieved the best coercivity (H cj =1845 Oe) due to spinodally decomposed (SD) phases with uniform and well-faceted mosaic morphology. As a result, the CMS sample had a lower Hcj than HIP and HP samples, but a higher remanence and thus the best energy product (6.5 MGOe) due to preferential grain alignment induced by abnormal grain growth.

36 MATERIALS SCIENCE↗

Organic preservation of vase‐shaped microfossils from the late Tonian Chuar Group, Grand Canyon, Arizona, USA

Abstract Vase‐shaped microfossils (VSMs) are found globally in middle Neoproterozoic (800–730 Ma) marine strata and represent the earliest evidence for testate (shell‐forming) amoebozoans. VSM tests are hypothesized to have been originally organic in life but are most commonly preserved as secondary mineralized casts and molds. A few reports, however, suggest possible organic preservation. Here, we test the hypothesis that VSMs from shales of the lower Walcott Member of the Chuar Group, Grand Canyon, Arizona, contain original organic material, as reported by B. Bloeser in her pioneering studies of Chuar VSMs. We identified VSMs from two thin section samples of Walcott Member black shales in transmitted light microscopy and used scanning electron microscopy to image VSMs. Carbonaceous material is found within the internal cavity of all VSM tests from both samples and is interpreted as bitumen mobilized from Walcott shales likely during the Cretaceous. Energy dispersive X‐ray spectroscopy (EDS) and wavelength dispersive X‐ray spectroscopy (WDS) reveal that VSM test walls contain mostly carbon, iron, and sulfur, while silica is present only in the surrounding matrix. Raman spectroscopy was used to compare the thermal maturity of carbonaceous material within the samples and indicated the presence of pyrite and jarosite within fossil material. X‐ray absorption spectroscopy revealed the presence of reduced organic sulfur species within the carbonaceous test walls, the carbonaceous material found within test cavities, and in the sedimentary matrix, suggesting that organic matter sulfurization occurred within the Walcott shales. Our suite of spectroscopic analyses reveals that Walcott VSM test walls are organic and sometimes secondarily pyritized (with the pyrite variably oxidized to jarosite). Both preservation modes can occur at a millimeter spatial scale within sample material, and at times even within a single specimen. We propose that sulfurization within the Walcott Shales promoted organic preservation, and furthermore, the ratio of iron to labile VSM organic material controlled the extent of pyrite replacement. Based on our evidence, we conclude that the VSMs are preserved with original organic test material, and speculate that organic VSMs may often go unrecognized, given their light‐colored, translucent appearance in transmitted light.

58 GEOSCIENCES↗

Size effects in 3D–printed polymer–derived, zirconium diboride–reinforced ceramic composites

Preceramic polymers are of interest for use in many manufacturing techniques such as injection molding, ceramic fiber infiltration, and additive manufacturing. However, off-gassing of low molecular weight oligomers occurs when these polymers cure, potentially leading to porosity in the cured part. Here to study how porosity and strength are affected by the size of the printed part, and the presence of a high surface area nano-scale filler, polycarbosilane (PCS) microrods of varying diameter were fabricated via direct ink writing (DIW), an additive manufacturing technique, with two ink formulations containing either zirconium diboride (ZrB 2 ) alone, or ZrB 2 and fumed alumina (FA). Sets of microrods were printed in a range of sizes by using print nozzles of 450, 634, 979, 1 346, or 1 702 μm in diameter, which were thermally cured, pyrolyzed to form ceramic composite microrods, and tested in 3-pt flexure. Porosity increased with increasing diameter, while failure strength decreased. For a given nozzle size, the microrods containing FA displayed lower porosity and higher strength (up to ~500 MPa) compared to the microrods containing only ZrB 2 . Weibull strength analysis was performed on each group of microrods and shows that the addition of FA increased Weibull modulus from 4.63 ± 1.56 to 9.35 ± 0.601. In conjunction with optical microscopy, this analysis indicates two distinct flaw populations in the printed materials, porosity which arises during the curing step and cracking which arises during pyrolysis of the larger specimens.

36 MATERIALS SCIENCE↗

Mechanical and Thermal Characterization of Phase-Change Material and High-Density Polyethylene Functional Composites for Thermal Energy Storage

Abstract Phase-change materials (PCMs) can be used to develop thermal energy storage systems as they absorb large amount of latent heat nearly at a constant temperature when changing phase from a solid to a liquid. To prevent leakage when in a liquid state, PCM is shape stabilized in a polymer matrix of high-density polyethylene (HDPE). The present research explores the injection-molded mechanical and thermal properties of different PCM/HDPE composite ratios. The tensile strength and modulus of elasticity at room temperature and with the PCM fully melted within the composite are measured. Additionally, the hardness, latent heat of fusion, phase-change temperature, and thermal conductivity are investigated. An analysis of microstructures of the composite is used to support the findings. The PCM within the PCM/HDPE composite gives it the benefit of thermal storage but causes a decrease in mechanical properties.

Energy & Fuels↗

Towards directed energy deposition of metals using polymer-based supports: porosity of 316L stainless steel deposited on carbon-fiber-reinforced ABS

Directed energy deposition (DED) is increasingly valuable to many industries because of its high deposition rates relative to other metal additive manufacturing processes, but the design space of DED is limited. For instance, steep overhangs are difficult or impossible to manufacture. Polymer-based support structures could help address this challenge. The viability of DED on polymer composite substrates has begun to be explored, specifically with 316L stainless steel on carbon-fiber-reinforced ABS substrates. Monolithic metal components can be deposited on the polymer, but it was found that gas release during polymer degradation causes porosity due to gas entrapment in the metal. An interlayer cooling time was introduced to reduce polymer degradation and decrease the porosity due to gas entrapment, but this led to porosity from lack of fusion. The results of this work provide insight into process parameter selection and scan strategy development to enable the use of polymer support structures in blown-powder DED.

Kurfess, Rebecca↗

Additive Manufacturing: A New Paradigm for the Next Generation of High-Power-Density Direct-Drive Electric Generators

In recent years, there has been a growing demand for high-power-density direct-drive generators in the wind industry owing to their high reliability, torque per unit volume, and conversion efficiencies. However, direct-drive wind turbine generators are very large, low-speed electric machines, which pose remarkable design and manufacturing issues that challenge their upscaling potential and cost of implementation. With air-gap tolerance as the main design driver, the need for high stiffness shifts the focus toward support-structure design that forms a significant portion of the generator's total mass. Existing manufacturing processes allow the use of segmented-steel-weldment disk or spoke-arm assemblies that yield stiffer structures per unit mass but tend to be heavier and more expensive to build. As a result, there is a need for a transformative approach to realize lightweight designs that can also facilitate series production at competitive costs. Inspired by recent developments in metal additive manufacturing (AM), we explore a new freedom in the structural design space with a high potential for weight savings in direct-drive generators. This includes the feasibility of using nonconventional complex geometries, such as lattice-based structures as structurally efficient options. Powder-binder jetting of a sand-cast mold was identified as the most feasible AM technology to produce large-scale generator rotor structures with complex geometry. A parametric optimization study was performed and optimized results within deformation and mass constraints were found for each design. The response to the maximum Maxwell stress due to unbalanced magnetic pull was also explored for each design. Further, a topology optimization was applied for each parameter-optimized design to validate results and provide insights into further mass reduction. These novel designs catered for AM are compared in both deflection and mass to conventional rotor designs using NREL's systems engineering design tool, GeneratorSE. The optimized lattice design with a U-beam truss resulted in a 24% reduction in structural mass of the rotor and 60% reduction in radial deflection. It is demonstrated that additive manufacturing shifts the focus from manufacturability constraints toward lower mass.

17 WIND ENERGY↗

Techniques for Analyzing Lens Manufacturing Data with Optical Design Applications

Optical designers assume a mathematically derived statistical distribution of the relevant design parameters for their Monte Carlo tolerancing simulations. However, there may be significant differences between the assumed distributions and the likely outcomes from manufacturing. Of particular interest for this study are the data analysis techniques and how they may be applied to optical and mechanical tolerance decisions. The effect of geometric factors and mechanical glass properties on lens manufacturability will be also be presented. Although the present work concerns lens grinding and polishing, some of the concepts and analysis techniques could also be applied to other processes such molding and single-point diamond turning.

optical design, statistics, optomechanical, manufa↗

Infrared thermography NDT for in-situ defect detection in sandwich composite panel manufacturing

Composite manufacturing presents numerous challenges, as defects can arise from various sources throughout the process. In sandwich composite structures, the integration of a foam core introduces additional complexity and increases the likelihood of defect formation like delamination. To mitigate these issues and reduce the risk of future structural failures, in-situ monitoring during manufacturing is essential. This study investigates infrared (IR) thermography as a non-destructive technique for detecting manufacturing defects in foam-core sandwich composite panels under thermally excited conditions representative of in-situ processing. A stationary FLIR A8590 IR camera (640 × 512 pixels, 30Hz, 17mm lens, 9 ft stand-off distance) was used to monitor prefabricated panels subjected to controlled external heating simulating compression molding and resin cure exotherm. Interlaminar delamination defects with characteristic sizes ranging from 0.25 × 0.25in² to 5 × 5in² produced measurable surface temperature depressions of approximately 4–10°C during transient cooling, exceeding the effective noise floor of the camera by more than two standard deviations. Thicker laminates exhibited prolonged defect detectability windows due to increased thermal diffusion time. In contrast, embedded Teflon inclusions generated weak thermal contrasts of ≤ 3°C, approaching the measurement noise floor, due to limited thermal property contrast with the surrounding glass fiber composite. These results establish quantitative detectability limits for stationary thermographic inspection of sandwich composite panels under manufacturing-representative thermal cycles.

Barakat, Abdallah [ORNL] (ORCID:0000000296141398)↗

Second-surface silvered glass solar mirrors of very high reflectance

This paper reports methods developed to maximize the overall reflectance second-surface silvered glass. The reflectance at shorter wavelengths is increased with the aid of a dielectric enhancing layer between the silver and the glass, while at longer wavelengths it is enhanced by use of glass with negligible iron content. The calculated enhancement of reflectance, compared to unenhanced silver on standard low-iron float glass, corresponds to a 4.4% increase in reflectance averaged across the full solar spectrum, appropriate for CSP, and 2.7% for CPV systems using triple junction cells. An experimental reflector incorporating these improvements, of drawn crown glass and a silvered second-surface with dielectric boost, was measured at NREL to have 95.4% solar weighted reflectance. For comparison, non-enhanced, wetsilvered reflectors of the same 4 mm thickness show reflectance ranging from 91.6 - 94.6%, depending on iron content. A potential drawback of using iron-free drawn glass is reduced concentration in high concentration systems because of the inherent surface errors. This effect is largely mitigated for glass shaped by slumping into a concave mold, rather than by bending.

14 SOLAR ENERGY↗

Design, Assembly, and Testing of a Photon Doppler Velocimetry Probe

A novel fiber-optic probe measures the velocity distribution of an imploding surface along many lines of sight. Reflected light from each spot on the moving surface is Doppler shifted with a small portion of this light propagating backwards through the launching fiber. The reflected light is mixed with a reference laser in a technique called photon Doppler velocimetry, providing continuous time records. Within the probe, a matrix array of 56 single-mode fibers sends light through an optical relay consisting of three types of lenses. Seven sets of these relay lenses are grouped into a close-packed array allowing the interrogation of seven regions of interest. A six-faceted prism with a hole drilled into its center directs the light beams to the different regions. Several types of relay lens systems have been evaluated, including doublets and molded aspheric singlets. The optical design minimizes beam diameters and also provides excellent imaging capabilities. One of the fiber matrix arrays can be replaced by an imaging coherent bundle. This close-packed array of seven relay systems provides up to 476 beam trajectories. The pyramid prism has its six facets polished at two different angles that will vary the density of surface point coverage. Fibers in the matrix arrays are angle polished at 8{sup o} to minimize back reflections. This causes the minimum beam waist to vary along different trajectories. Precision metrology on the direction cosine trajectories is measured to satisfy environmental requirements for vibration and temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel transparent electrodes allow sustainable production of electronic devices

A novel technique for fabricating inexpensive, transparent electrodes from common metals has been developed by engineers and scientists at Iowa State University and Ames Laboratory. They exhibit very high transparency and are very good electrical conductors. This is a combination of properties that is difficult to achieve with common materials. The most frequently used transparent electrode in today's high-technology devices (such as LCD screens) is indium tin oxide (ITO). While ITO performs well in these applications, the supply of indium is very limited. In addition, it is rapidly decreasing as consumer demand for flat-panel electronics is skyrocketing. According to a 2004 US Geological Survey report, as little as 14 years exploitation of known indium reserves remains. In addition to increasing prices, the dwindling supply of indium suggests its use is not sustainable for future generations of electronics enthusiasts. Solar cells represent another application where transparent electrodes are used. To make solar-energy collection economically feasible, all parts of solar photovoltaics must be made more efficient and cost-effective. Our novel transparent electrodes have the potential to do both. In addition, there is much interest in developing more efficient, cost-effective, and environmentally friendly lighting. Incandescent light bulbs are very inefficient, because most of their energy consumption is wasted as heat. Fluorescent lighting is much more efficient but still uses mercury, an environmental toxin. An attractive alternative is offered by LEDs, which have very high efficiencies and long lifetimes, and do not contain mercury. If made bright enough, LED use for general lighting could provide a viable alternative. We have fabricated electrodes from more commonly available materials, using a technique that is cost effective and environmentally friendly. Most of today's electronic devices are made in specialized facilities equipped with low-particle-count clean-room facilities and multimillion-dollar equipment. On the other hand, the novel process we developed uses a method that makes use of polymer molds and standard deposition techniques in an ambient laboratory environment. The final structure consists of tall ribbons of metal (standing on edge) that are so thin that they do not block light but are very good conductors. The advantage of this design is that it avoids the competition between conductivity and transparency inherent in transparent oxide electrodes. By making the structure taller, conductivity can be increased without impacting transparency. We have measured both electrical conductivity and transparency for these structures. We performed two-wire electrical measurements to quantify the structures resistance using metal contacts deposited on each end. The total sample area was 4 x 4mm{sup 2}. We measured a resistance of structures with 40nm gold sidewalls of 7.3{Omega}, which is lower than that of ITO glass (which has a sheet resistance around 10O/square). We investigated the structures optical properties based on both specular- and total-transmission measurements. Specular transmission is measured by collecting the transmitted light at normal incidence, while total transmission is obtained by collecting transmitted light at normal incidence and diffracted light using an integrating sphere. Figure 3 shows the total transmission of a grating with 40nm gold or silver sidewalls on a glass substrate compared to that of ITO. Additionally, the transparency changes very little within 30{sup o} off normal incidence. This high visible-light transmission of our metal-patterned structures is very promising for their application as transparent electrodes, because most visible light was allowed to propagate through the patterned metallic/polymeric structures. Researchers in our group continue to refine the fabrication methods and are investigating methods to make large-scale structures for use in a variety of applications that require both transparency and high electrical conductivity. We are also applying these fabrication techniques to build other structures that can manipulate light in novel ways.

14 SOLAR ENERGY↗

HDR brachytherapy of rectal cancer using a novel grooved-shielding applicator design

Purpose: The aim of this work was to design a novel high-dose rate (HDR) ({sup 192}Ir) brachytherapy applicator for treatment of rectal carcinomas that uses tungsten shielding for possibly improved dosimetric results over commercial brachytherapy applicator(s).Methods: A set of 15 single-depth applicators and one dual-depth applicator were designed and simulated using Monte Carlo (MCNPX). All applicators simulated were high-density tungsten alloy cylinders, 16-mm in diameter, and 60-mm long, with longitudinal grooves within which an {sup 192}Ir source can be placed. The single-depth designs varied regarding the number and depth of these grooves, ranging from 8 to 16 and 1-mm to 3-mm, respectively. The dual-depth design had ten channels, each of which had two depths at which the source could be placed. Optimized treatment plans were generated for each design on data from 13 treated patients (36 fractions) with asymmetrical clinical target volumes (CTVs). All results were compared against the clinically treated plans which used intracavitary mold applicator (ICMA), as well as a recently designed, highly automated, and collimated intensity modulation device named dynamic modulated brachytherapy (DMBT) device.Results: All applicator designs outperformed the ICMA in every calculated dosimetric criteria, except the total dwell times (∼30% increase). There were clear, but relative, tradeoffs regarding both the number of channels and the depth of each channel. Overall, the 12-channel, 1-mm depth, and 14-channel 2-mm depth designs had the best results of the simpler designs, sparing the healthy rectal tissues the most while achieving comparable CTV coverage with the dose heterogeneity index and lateral spill doses improving by over 10% and the contralateral healthy rectum dose dropping over 30% compared to ICMA. The ten-channel dual-depth design outperformed each single-depth design, yielding the best coverage and sparing.Conclusions: New grooved tungsten HDR-brachytherapy devices have been designed and simulated. The results of this work attest to the capability of these new, highly anisotropic, intelligently shielded applicators to limit dose to healthy tissues while maintaining a conformal prescription dose to the CTV.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-265: Presage Thin Sheet Dosimeter Characterization

Purpose: To quantify the sensitivity and stability of the Presage dosimeter in sheet form for different concentrations of chemicals and for a diverse range of clinical photon energies. Methods: Presage polymer dosimeters are formulated to investigate and optimize their sensitivity and stability. The dosimeter is composed of clear polyurethane base, leucomalachite green reporting dye, and bromoform radical initiator in 1mm thick sheets. The chemicals are well mixed together, cast in an aluminum mold, and left to cure at 60 psi for a minimum of 2 days. Dosimeter response will be characterized at multiple energies including Co-60, 6 MV, 15 MV, 50 kVp, and 250 kVp. The dosimeters are read by an Epson 10000 XL scanner at 800 dpi, 2{sup 16} bit depth. Red component images are analyzed with ImageJ. Results: Analysis of optical density verse dose for Co-60 energies indicates that the bromoform containing Presage was able to quantify dose from 0 to 300 Gy, with saturation beyond 300 Gy. Initial results show two regions of linear response, 0–100 Gy and 150–300 Gy. The 150–300 Gy region has a sensitivity of 0.0024 net OD/Gy. Further results on other energies are still in progress. Conclusions: This work shows the potential for use of thin sheets of Presage dosimeter as a dosimeter capable of being analyzed with a flatbed scanner.

60 APPLIED LIFE SCIENCES↗

SU-E-T-511: Do Presage 3D Dosimeters Show Dose Fractionation Sensitivity?

Purpose: To determine whether Presage 3D polymer dosimeter dose response is sensitive to dose delivery fractionation. Bang gels have demonstrated a dose fractionation related dependence in which a single 400 cGy irradiation would produce a different detector response than four 100 cGy irradiations even if delivered closely in time to one another. Such a fractional dependent response in Presage would be detrimental for measuring multi-beam irradiations. Methods: Two separate batches of Presage were poured into cuvettes, and a third batch was molded into cuvette shaped blocks. A total of 37 cuvettes/blocks were irradiated in a Cobalt-60 irradiator to 400 cGy within solid water phantoms in either one, eight, or sixteen fractions. Another group of 15 cuvettes were also kept unirradiated and used for background subtraction between the pre-scan and post-scan results. The times between fractional deliveries were held constant at 30 seconds and the Cobalt irradiator dose rate was 49 cGy/min. Each Presage batch has a separate dose sensitivity and therefore fractionation response comparisons were only performed within the same batch. The cuvettes were first pre-scanned the day prior to irradiation and post-scanned the day after irradiation. Other than approximately 3 hours warming time prior to each irradiation and optical density measurement the cuvettes were stored in a refrigerator. All cuvettes were stored in a lightless environment throughout manufacturing and testing. The cuvettes’ optical densities were optically measured at 632 nm with a spectrophotometer. Results: No noticeable dose fractionation dependence was detected for any of the three independent batches of Presage for either the eight or sixteen fraction irradiation schemes. Conclusion: These results indicate using Presage 3D dosimeters to measure multi-beam photon irradiations common in IMRT, Gamma Knife, and Cyberknife treatment delivery schemes. Presage dosimeters are made by and trademarked by Heuris Inc. Skillman, NJ. Dr. John Adamovics is a founder of Heuris Inc.

07 ISOTOPE AND RADIATION SOURCES↗

SU-C-19A-07: Influence of Immobilization On Plan Robustness in the Treatment of Head and Neck Cancer with IMPT

Purpose: We evaluated the effect of interposing immobilization devices into the beam's path on the robustness of a head and neck plan. Methods: An anthropomorphic head phantom was placed into a preliminary prototype of a specialized head and neck immobilization device for proton beam therapy. The device consists of a hard low density shell, a custom mold insert, and thermoplastic mask to immobilize the patient's head in the shell. This device was provided by CIVCO Medical Solutions for the purpose of evaluation of suitability for proton beam therapy. See Figure 1. Two pairs of treatment plans were generated. The first plan in each pair was a reference plan including only the anthropomorphic phantom, and the second plan in each pair included the immobilization device. In all other respects the plans within the pair were identical. Results: In the case of the simple plan the degradation of plan robustness was found to be clinically insignificant. In this case, target coverage in the worst case scenario was reduced from 95% of the target volume receiving 96.5% of prescription dose to 95% of the target volume receiving 96.3% of prescription dose by introducing the immobilization device. In the case of the complex plan, target coverage of the boost volume in the worst case scenario was reduced from 95% of the boost target volume receiving 97% of prescription dose to 95% of the boost target volume receiving 83% of prescription dose by introducing the immobilization device. See Figure 2. Conclusion: Immobilization devices may have a deleterious effect on plan robustness. Evaluation of the preliminary prototype revealed a variable impact on the plan robustness depending of the complexity of the case. Brian Morse is an employee of CIVCO Medical Solutions.

60 APPLIED LIFE SCIENCES↗