Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MICROSCOPE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Microscopic Examination of the Silicon Surface Subjected to High-Dose Silver Implantation

Low-energy (E = 30 keV) Ag{sup +} ions have been implanted into single-crystalline Si wafers (c-Si) with an implantation dose varying from 1.25 × 10{sup 15} to 1.5 × 10{sup 17} ions cm{sup –2} and an ion beam current density varying from 2 to 15 μA/cm{sup 2}. The surface morphology of implanted wafers has been examined using scanning electron microscopy, transmission electron microscopy, and atomic force microscopy, and their structure has been studied by means of reflection high-energy electron diffraction and elemental microanalysis. It has been shown that for minimal irradiation doses used in experiments, the surface layer of c-Si experiences amorphization. It has been found that when the implantation dose is in excess of the threshold value (~3.1 × 10{sup 15} ions cm{sup –2}), Ag nanoparticles uniformly distributed over the Si surface arise in the irradiated Si layer. At a dose exceeding 10{sup 17} ions cm{sup –2}, a porous Si structure is observed. In this case, the Ag nanoparticle size distribution becomes bimodal with coarse particles localized at the walls of Si pores.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Daniel Gogny’s vision for a microscopic theory of fission

Daniel Gogny made many contributions to our understanding of nuclear fission over a span of 35 years. This paper reviews some of those contributions, focusing in particular on fission dynamics, the challenges of describing scission in a quantum-mechanical context, and the calculation of fragment properties such as their mass, kinetic, and excitation energy distributions. Here, the generator coordinate method provides the common theoretical framework within which these various aspects of fission are formulated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Beyond $\rho ^{2/3}$ scaling: microscopic origins and multimessengers of high-density nuclear symmetry energy

The nature and Equation of State (EOS) of dense neutron-rich matter are still very poorly known, while they have broad impacts on many interesting issues in both astrophysics and nuclear physics. In particular, the nuclear symmetry energy $E_{\textrm{sym}}(\rho )$ encoding the cost to make nuclear matter more neutron-rich has been the most uncertain component of the EOS of dense neutron-rich nucleonic matter. It significantly affects the radii, tidal deformations, cooling rates, and frequencies of various oscillation modes of isolated neutron stars as well as the strain amplitude and frequencies of gravitational waves from their mergers, besides its many effects on the structures of nuclei as well as the dynamics and observables of their collisions. Siemens (1970s) observed that $E_{\textrm{sym}}(\rho )$ scales as $(\rho /\rho _0)^{2/3}$ near the saturation density $\rho _0$ of nuclear matter, since both the kinetic part and the potential contribution (quadratic in momentum) exhibit this dependence. The scaling holds if: (1) the nucleon isoscalar potential is quadratic in momentum, and (2) the isovector interaction is weakly density-dependent. After examining many empirical evidences and understanding theoretical findings in the literature, we conclude that: (1) Siemens’ $\rho ^{2/3}$ scaling is robust and serves as a valuable benchmark for both nuclear theories and experiments up to $2\rho _0$ but breaks down at higher densities, (2) Experimental and theoretical findings about $E_{\textrm{sym}}(\rho )$ up to $2\rho _0$ are broadly consistent, but uncertainties remain large for its curvature $K_{\textrm{sym}}(\rho )$ and higher-order parameters, (3) Above $2\rho _0$ , uncertainties grow due to poorly constrained spin-isospin-dependent tensor and three-body forces as well as the resulting nucleon short-range correlations. Looking forward, combining signals from both observations of neutron stars and terrestrial heavy-ion reaction experiments is the most promising path to finally constraining the high-density $E_{\textrm{sym}}(\rho )$ and the EOS of supradense neutron-rich matter. Multiple examples of community efforts to further constrain the high-density $E_{\textrm{sym}}(\rho )$ using both real and mocked data of present and future high-precision observations of neutron stars, as well as heavy-ion collisions involving high-energy rare isotopes, are briefly reviewed.

Li, Bao-An [East Texas A & M Univ., Commerce, TX (↗

A microscopic description of black hole evaporation via holography

Here, we propose a description of how a large, cold black hole (black zero-brane) in type IIA superstring theory evaporates into freely propagating D0-branes, by solving the dual gauge theory quantitatively. The energy spectrum of emitted D0-branes is parametrically close to thermal when the black hole is large. The black hole, while initially cold, gradually becomes an extremely hot and stringy object as it evaporates. As it emits D0-branes, its emission rate speeds up and it evaporates completely without leaving any remnant. Hence this system provides us with a concrete holographic description of black hole evaporation without information loss.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A microscopic model for an emergent cosmological constant

In this work, the value of the cosmological constant is explained in terms of a noisy diffusion of energy from the low energy particle physics degrees of freedom to the fundamental Planckian granularity which is expected from general arguments in quantum gravity. The quantitative success of our phenomenological model is encouraging and provides possibly useful insights about physics at the scale of quantum gravity.

79 ASTRONOMY AND ASTROPHYSICS↗

From microscopic black hole entropy toward Hawking radiationc

The AdS/CFT correspondence has recently provided a novel approach for counting the microstates of black holes impressively matching the macroscopic Bekenstein–Hawking entropy formula of rotating electrically charged asymptotically AdS black holes in four to seven dimensions. This approach is designed for supersymmetric extremal black holes, but can also be extended to nonsupersymmetric, near-extremal black holes. Besides the dual higher-dimensional boundary CFT, an effective 2D CFT emerges in a certain near-horizon limit accounting for both the extremal and the near-extremal black hole entropies. Furthermore, this effective 2D description is universal across dimensions and comes naturally equipped with an approach to quantitatively tackle aspects of Hawking radiation.

79 ASTRONOMY AND ASTROPHYSICS↗

Correlation Between Microscopic Current Fluctuations Observed at Ultra-Microelectrodes and Macroscopic Bulk Electrolysis Performance in Redox-Active Microemulsions

Microemulsions (μEs) have been proposed as redox flow battery (RFB) electrolytes that maximize ionic conductivity and charge capacity by synergizing two immiscible phases. However, charge transfer during electrolysis in μEs is poorly understood. Here, we show that ultramicroelectrode electrolysis of ferrocene-loaded μEs –20%, 60%, and 90% water - reveals stochastic current fluctuations. These are differentiated in the scanning electrochemical microscopy (SECM) geometry, where power spectral density analysis showed distinct changes in the frequency contributions. SECM in the substrate generation-tip collection mode showed that fluctuations arise under mass-transfer control. Significant differences in the diffusion coefficient of ferrocene species were deducted from SECM approach curves, suggesting phase transfer behavior. Using bulk electrolysis, we calculated the charge accessibility and cycling behavior in the μEs. A decrease in the stochastic behavior of the μEs seems to correlate to a higher accessibility and cycling performance, with the 90% water μE displaying the best reversibility and the 60% the lowest. Altogether, these results suggest that Marangoni-type convection driven by concentration gradients and/or μE restructuring during charge transfer play a role in the electrochemical performance of μEs. This presents opportunities for screening and diagnosing the performance of these emerging RFB electrolytes.

25 ENERGY STORAGE↗

In Situ Liquid Electron Microscope Cells Strongly Attenuate Electrochemical Behavior

In situ electrochemical Scanning Transmission Electron Microscopy (ec-S/TEM) probes the dynamics of electrochemical processes in real time and at high spatial resolution. This method utilizes microfabricated electrochemical cells, with enclosed dimensions of 800 μm wide, 800 μm long, and 1–2 μm tall, with electron-transparent silicon nitride windows. Working, counter, and reference electrodes in the configuration studied are deposited Pt with a planar surface area of about 1 μm 2 and a height of 50 nm. The cell confines the electrolyte within a 1 μm tall channel, and the microfabricated electrodes have a non-standard geometry, are coplanar, and are not front-facing. As such, standard assumptions of electrochemical experiments do not apply. COMSOL modeling was used to compare and contrast differences in electrochemical behavior between conventional experimental setups and the in situ ec-S/TEM cells. Cell height strongly affected voltammogram measurements: peak magnitudes and shifts correlate directly to cell height. Reactant concentration above the electrode quickly decreases during deposition, leading to a planar diffusion-dominated regime. The concentration gradient prioritizes particle growth along the thin edges of the electrode and not on the planar part of the electrode. Experiments done in the ec-S/TEM ex situ of a TEM verify the model’s accuracy.

Wittman, Reed M. [Oak Ridge National Laboratory (O↗

Detecting structural variances of Co3O4 catalysts by controlling beam-induced sample alterations in the vacuum of a transmission electron microscope

Abstract This article summarizes core aspects of beam-sample interactions in research that aims at exploiting the ability to detect single atoms at atomic resolution by mid-voltage transmission electron microscopy. Investigating the atomic structure of catalytic Co 3 O 4 nanocrystals underscores how indispensable it is to rigorously control electron dose rates and total doses to understand native material properties on this scale. We apply in-line holography with variable dose rates to achieve this goal. Genuine object structures can be maintained if dose rates below ~100 e/Å 2 s are used and the contrast required for detection of single atoms is generated by capturing large image series. Threshold doses for the detection of single atoms are estimated. An increase of electron dose rates and total doses to common values for high resolution imaging of solids stimulates object excitations that restructure surfaces, interfaces, and defects and cause grain reorientation or growth. We observe a variety of previously unknown atom configurations in surface proximity of the Co 3 O 4 spinel structure. These are hidden behind broadened diffraction patterns in reciprocal space but become visible in real space by solving the phase problem. An exposure of the Co 3 O 4 spinel structure to water vapor or other gases induces drastic structure alterations that can be captured in this manner.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sub-Ångstrom electric field measurements on a universal detector in a scanning transmission electron microscope

Scanning transmission electron microscopy (STEM) excels in accessing atomic-scale structure and chemistry. Enhancing our ability to directly image the functionalities of local features in materials has become one of the most important topics in the future development of STEM. Recently, differential phase contrast (DPC) imaging has been utilized to map the internal electric and magnetic fields in materials from nanoscale features such as p–n junctions, skyrmions, and even from individual atoms. Here, we use an ultra-low noise SCMOS detector in as the diffraction plane camera to collect four-dimensional (4D) datasets. The high angular resolution, efficient high-SNR acquisition, and modifiability of the camera allow it to function as a universal detector, where STEM imaging configurations, such as DPC, bright field, annular bright field, and annular dark field can all be reconstructed from a single 4D dataset. By examining a distorted perovskite, DyScO3, which possesses projected lattice spacings as small as 0.83 Å, we demonstrate DPC spatial resolution almost reaching the information limit of a 100 keV electron beam. In addition, the perovskite has ordered O-coordinations with alternating octahedral tilts, which can be quantitatively measured with single degree accuracy by taking advantage of DPC’s sensitivity to light atoms. The results, acquired on a standard Ronchigram camera as opposed to a specialized DPC detector, open up new opportunities to understand and design functional materials and devices that involve lattice and charge coupling at nano- and atomic-scales.

47 OTHER INSTRUMENTATION↗

Imaging effectiveness calculator for non-design microscope samples

When attempting to integrate single-molecule fluorescence microscopy with microfabricated devices such as microfluidic channels, fabrication constraints may prevent using traditional coverslips. Instead, the fabricated devices may require imaging through material with a different thickness or index of refraction. Altering either can easily reduce the quality of the image formation (measured by the Strehl ratio) by a factor of 2 or more, reducing the signal-to-noise ratio accordingly. In such cases, successful detection of single-molecule fluorescence may prove difficult or impossible. Furthermore, we provide software to calculate the effect of non-design materials upon the Strehl ratio or ensquared energy and explore the impact of common materials used in microfabrication.

47 OTHER INSTRUMENTATION↗

Two-photon X-ray ghost microscope

This article presents a non-classical imaging mechanism that produces a diffraction-limited and magnified ghost image of the internal structure of an object through the measurement of intensity fluctuation correlation formed by two-photon interference. In principle, the lensless X-ray ghost imaging mechanism may achieve a spatial resolution determined by the wavelength and the angular diameter of the X-ray source, ∼ λ /Δ θ s , with possible reduction caused by additional optics. In addition, it has the ability to image select “slices” deep within an object, which can be used for constructing 3D view of its internal structure.

Smith, Thomas A. (ORCID:0000000275427047)↗