Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC FIELD COIL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

PERSISTENT CURRENT EFFECT IN 15-16 T NB3SN ACCELERATOR DIPOLES AND ITS CORRECTION

Nb3Sn magnets with operating fields of 15-16 T are considered for the LHC Energy Doubler and a future Very High Energy pp Collider. Due to large coil volume, high critical current density and large superconducting (SC) filament size the persistent current effect is very large in Nb3Sn dipoles al low fields. This paper presents the results of analysis of the persistent current effect in the 15 T Nb3Sn dipole demonstrator being developed at FNAL, and describes different possibilities of its correction including passive SC wires, iron shims and coil geometry.

43 PARTICLE ACCELERATORS↗

Magnetic Field Analysis of Helical Undulators

The analytical expression of the on-axis field for an infinitely long helical undulator, derived in terms of undulator period length, uniform current density, inner ra ius and dimensions of the coils, was compared with numerical analyses of model undulators based on the Biot-Savart law. The two calculations agreed within 1 x 10 -3 . The expression also showed that the on-axis field has the first harmonic only, and no higher harmonics exist, regardless of the coil dimensions. Calculations for 61-period models showed that the third and fifth harmonics were less than 2 x 10 -7 . For a finite-length model the end fields were adjusted by reducing the currents in a discrete number of steps for the last two or four periods of both ends. It was also shown as a practical method that increasing the coil winding radius can be a substitute for reducing the coil current.

Kim, S. H.↗

Design for a Muon Front End with Magnetically Shielded RF Cavities

In the baseline Neutrino Factory muon front end, strong, closely spaced solenoid magnets are used to contain the high emittance muon beam. In addition, significant acceleration is required for bunching, phase rotation and cooling, requiring RF cavities operating near to their maximum achievable gradient. There are experimental indications that RF cavities may not be able to achieve these large gradients in the presence of such intense magnetic fields. In this paper, I discuss the design of a muon cooling channel that is designed with RF cavities removed from the intense magnetic fields, and examine the change in performance that results from this compromise.

43 PARTICLE ACCELERATORS↗

Correction of the axial asymmetry of the poloidal magnetic field in the Globus-M spherical tokamak

The toroidal inhomogeneity of the poloidal magnetic field-the so-called error fields that arise due to imperfections in manufacturing and assembling of the electromagnetic system-was measured in the Globus-M spherical tokamak. A substantial inhomogeneity corresponding to the n = 1 mode, which gave rise to a locked mode and led to discharge disruption, was revealed. After compensation of this inhomogeneity with the help of special correction coils, the discharge duration increased and the global plasma parameters improved substantially. A technique for determining and compensating the n = 1 mode inhomogeneity is described, the measured dependences of the penetration threshold of the m = 2/n = 1 mode on the plasma parameters are given, and results of experiments in which record parameters for the Globus-M tokamak were achieved after correction of the poloidal magnetic field are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nonlinear modeling of ELM mitigation with RMP on HL-2A

Abstract Nonlinear modeling of mitigation of the edge localized mode (ELM) with resonant magnetic perturbation (RMP) is performed for the HL-2A tokamak, utilizing the three-dimensional (3D) magnetohydrodynamic code JOREK. Based on the 3D equilibrium established after application of the n = 1 ( n is the toroidal mode number) RMP at 4.9 kAt coil current with odd parity, ELM mitigation is successfully simulated consistent with the experimental result. Nonlinear simulations show strong mode coupling among toroidal Fourier harmonics, allowing redistribution of the magnetic energy such that the most unstable toroidal mode saturates at a lower level. This magnetic energy cascade offers an explanation of the RMP-induced ELM mitigation achieved in HL-2A. Detailed examination of the simulation results shows persistent resonant field screening even during the ELM mitigation phase. Finite plasma resistivity however does enable partial penetration of the resonant field thus modifying the edge magnetic topology and characteristics of the edge transport. Plasma radial profiles undergo pronounced changes around the pedestal region, when the magnetic energy of the most unstable toroidal mode reaches the maximum value. Systematic scans of the applied RMP coil current with the JOREK simulations find a threshold value of around 4.5 kAt required for achieving the ELM mitigation on HL-2A.

Physics↗

Trapping ultracold atoms in a time-averaged adiabatic potential

We report an experimental realization of ultracold atoms confined in a time-averaged, adiabatic potential (TAAP). This trapping technique involves using a slowly oscillating ({approx}kHz) bias field to time-average the instantaneous potential given by dressing a bare magnetic potential with a high-frequency ({approx}MHz) magnetic field. The resultant potentials provide a convenient route to a variety of trapping geometries with tunable parameters. We demonstrate the TAAP trap in a standard time-averaged orbiting potential trap with additional Helmholtz coils for the introduction of the radio frequency dressing field. We have evaporatively cooled 5x10{sup 4} atoms of {sup 87}Rb to quantum degeneracy and observed condensate lifetimes of longer than 3 s.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetization, Low Field Instability and Quench of RHQT Nb(3)Al Strands

Since 2005, we made and tested three RHQT Nb{sub 3}Al strands, one with Nb matrix and two with Ta matrix, which are fully stabilized with Cu electroplating. We observed anomalously large magnetization curves extending beyond 1 to 1.5 Tesla with the F1 Nb matrix strand at 4.2 K, when we measured its magnetization with a balanced coil magnetometer. This problem was eliminated with the Ta matrix strands operating at 4.2 K. But with these strands a similar but smaller anomalous magnetization was observed at 1.9 K. We studied these phenomena with FEM. With the F1 Nb matrix strand, it is explained that at low external field, inter-filamentary coupling currents in the outer layers of sub-elements create a shielding effect. It reduces the inside field, keeps the inside Nb matrix superconductive, and stands against a higher outside field beyond the Hc of Nb. At an even higher external field, the superconductivity of the whole Nb matrix collapses and releases a large amount of energy, which may cause a big quench. Depending on the size of the energy in the strand or the cable, a magnet could quench, causing the low field instability. Some attempt to analyze the anomaly with FEM is presented.

43 PARTICLE ACCELERATORS↗

Magnetic measurements using array of integrated Hall sensors on the CASTOR tokamak

We have performed the first tests of 'integrated' Hall sensors (IHSs) in a tokamak in-vessel environment. IHS combines the sensing element together with the complex electronic circuitry on a single small chip. The on-chip integrated circuits provide stabilization of the supply voltage, output amplification, noise suppression, and elimination of temperature dependencies. Eight IHSs of A1322LUA type produced by Allegro MicroSystems, Inc. were mounted on a stainless steel ring symmetrically encircling the CASTOR plasmas in poloidal direction 10 mm outside the limiter radius. IHSs were oriented such that they measure the horizontal and vertical magnetic fields. We found out that these sensors qualify for in-vessel use of small to middle sized fusion devices where the radiation is not an issue and the temperature below 150 deg. C can be guaranteed. The main advantages over the traditional pickup coils are the smaller size and more straightforward interpretation of output without the need of rather cumbersome integration and drift removal procedure associated with the use of inductive loops. We successfully exploited the sensors for determination of vertical plasma displacement on CASTOR. This new diagnostic helped us to shed more light into long term observed discrepancy on CASTOR between vertical plasma displacement as deduced by standard magnetic and by nonmagnetic diagnostics (Langmuir probes, bolometers)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of Coil Current on the Properties of Hydrogenated DLC Coatings Fabricated by Filtered Cathodic Vacuum Arc Technique

We successfully prepared hydrogenated DLC (a-C:H) with a thickness higher than 25 μm on stainless steel using a filtered cathode vacuum arc (FCVA) technique. The structural and mechanical properties of DLC were systematically analyzed using different methods such as x-ray photoelectron spectroscopy, Raman spectroscopy, scanning electron microscopy, Vickers hardness, nanohardness, and friction and wear tests. The effect of coil current on the arc voltage, ion current, and mechanical properties of resultant films was systematically investigated. The novelty of this study is the fabrication of DLC with Vickers hardness higher than 1500 HV, in the meanwhile with the thickness higher than 30 μm through varying the coil current with FCVA technique. The results indicated that the ion current, deposition rate, friction coefficient, and Vickers hardness of DLC were significantly affected by the magnetic field inside the filtered duct.

36 MATERIALS SCIENCE↗

Effect of Various Errors on the Spin Tune and Stable Spin Axis

Even though RHIC has two full Siberian snakes in each ring, there are various perturbations to the ideal case including orbit errors at the snakes, experiment solenoids, injection bumps, and interlaced horizontal-vertical bumps at the hydrogen jet polarimeter. These errors can cause depolarization by shifting the spin tune and tilting the stable spin direction away from vertical. Tilting of the stable spin axis can enhance horizontal depolarizing resonances. This paper presents preliminary results for some of these error scenarios, as well as their impact on the stable spin directions at STAR and PHENIX.

43 PARTICLE ACCELERATORS↗

Identification of multiple eigenmode growth rates towards real time detection in DIII-D and KSTAR tokamak plasmas

Abstract The successful application of three-dimensional (3D) magnetohydrodynamic (MHD) spectroscopy enables us to identify the multi-mode eigenvalues in DIII-D and KSTAR tokamak experiments with stable plasmas. The temporal evolution of the multi-modes’ stabilities have been detected. The new method is numerically efficient allowing the real time detection of MHD modes’ stabilities during the discharge. The method performs active detection of the plasma stability by utilizing the upper and lower rows of internal non-axisymmetric coils to apply a wide variety of 3D fields. Multi-mode eigenvalues are extracted using subspace system identification of the plasma response measured by 3D-field magnetic sensors distributed at different poloidal locations. The equivalence of this new method with the one introduced by Wang (2019 Nucl. Fusion 59 024001) has been numerically corroborated. The more robust and efficient calculation developed here will enable real time monitoring of the plasma stability based on the extracted eigenvalues of stable modes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Transformer Analysis with ANSYS Maxwell and COMSOL

This is an extension of work described by Rodriguez et al . (2021). It continues analyses of a generic transformer design by Wes Greenwood. In this report, we summarize that work and add comparable results using the ANSYS Maxwell software (henceforward, “ANSYS”), and with COMSOL . We found the ANSYS and COMSOL calculations of inductance agreed well with previous results for simplified coils in air, and with a ferromagnetic core. We then describe the ANSYS and COMSOL approach and show results for a full transformer model based on magnetic field analyses. Finally, we present electrostatic analyses of E field enhancement, once again resolving individual wires. The purpose is to assess the electrostatic fields in order to locate where electric breakdown is likely to originate. We found the maximum enhancement between the secondary and either the primary or the tertiary at the end of the windings with a large potential difference.

42 ENGINEERING↗

Magnetoelastic sensors in combination with nanometer-scale honeycombed thin film ceramic TiO2 for remote query measurement of humidity

Ribbonlike magnetoelastic sensors can be considered the magnetic analog of an acoustic bell; in response to an externally applied magnetic field impulse the sensors emit magnetic flux with a characteristic resonant frequency. The magnetic flux can be detected external to the test area using a pick-up coil, enabling query remote monitoring of the sensor. The characteristic resonant frequency of a magnetoelastic sensor changes in response to mass loads. [L.D. Landau and E. M. Lifshitz, Theory of Elasticity, 3rd ed. (Pergamon, New York, 1986). p. 100].Therefore, remote query chemical sensors can be fabricated by combining the magnetoelastic sensors with a mass changing, chemically responsive layer. In this work magnetoelastic sensors are coated with humidity-sensitive thin films of ceramic, nanodimensionally porous TiO2 to make remote query humidity sensors. c2000 American Institute of Physics.

NASA Discipline Life Sciences Technologies↗

Quench performance of a 4-m long Nb3Sn shell-type dipole coil

Fermilab has finished the first phase of Nb{sub 3}Sn technology scale up by testing 2-m and 4-m long shell-type dipole coils in a 'magnetic mirror' configuration. The 2-m long coil, made of Powder-in-Tube (PIT) Nb{sub 3}Sn strand, reached its short sample limit at a field level of 10 T. The 4-m long coil, made of advanced Nb{sub 3}Sn strand based on the Restack Rod Process (RRP) of 108/127 design, has been recently fabricated and tested. Coil test results at 4.5 K and 2.2 K are reported and discussed.

43 PARTICLE ACCELERATORS↗

Some Aspects of an Air-Core Single-Coil Magnetic Suspension System

This paper presents some of the technical aspects in the development at the Langley Research Center of an air-cove, dual-wound, single-coil, magnetic-suspension system with one-dimensional control. Overall electrical system design features and techniques are discussed in addition to the problems of control and stability. Special treatment is given to the operation of a dual-wound, high-current support coil which provides the bias fields and superimposed modulated field. Other designs features include a six-phase, solid-state power stage for modulation of the relatively large magnitude control current, and an associated six-phase trigger circuit.

SUPPORT SYSTEM↗

Dynamical cancellation of pulse-induced transients in a metallic shielded room for ultra-low-field magnetic resonance imaging

Pulse-induced transients such as eddy currents can cause problems in measurement techniques where a signal is acquired after an applied preparatory pulse. In ultra-low-field magnetic resonance imaging, performed in magnetic fields typically of the order of 100 μT, the signal-to-noise ratio is enhanced in part by prepolarizing the proton spins with a pulse of much larger magnetic field and in part by detecting the signal with a Superconducting QUantum Interference Device (SQUID). The pulse turn-off, however, can induce large eddy currents in the shielded room, producing an inhomogeneous magnetic-field transient that both seriously distorts the spin dynamics and exceeds the range of the SQUID readout. It is essential to reduce this transient substantially before image acquisition. We introduce dynamical cancellation (DynaCan), a technique in which a precisely designed current waveform is applied to a separate coil during the later part and turn off of the polarizing pulse. This waveform, which bears no resemblance to the polarizing pulse, is designed to drive the eddy currents to zero at the precise moment that the polarizing field becomes zero. We present the theory used to optimize the waveform using a detailed computational model with corrections from measured magnetic-field transients. SQUID-based measurements with DynaCan demonstrate a cancellation of 99%. Dynamical cancellation has the great advantage that, for a given system, the cancellation accuracy can be optimized in software. This technique can be applied to both metal and high-permeability alloy shielded rooms, and even to transients other than eddy currents.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Study on Conduction Cooling of Superconducting Magnets for the ILC Main Linac

In the main linac of the International Linear Collider (ILC), superconducting magnets for beam focusing and steering will be located periodically in superconducting RF (SRF) cavity string for beam acceleration in common cryomodules. A concept of conduction cooling of the combined-functioned, splittable superconducting magnets has been proposed and investigated to adapt much different features and to meet different requirements for the superconducting magnet and SRF cavity in fabrication, assembly, and operation. It is required to integrate the superconducting magnet after the SRF cavity string assembly which completed under an ultra-clean environment. The magnet must be conductively cooled down through thermal links to a liquid helium supply pipe. According to this concept, a model magnet development was carried out in cooperation with Fermilab and KEK, and has been demonstrated in KEK superconducting RF test facility (STF). In addition, an important issue has been recently identified. High gradient SRF cavities naturally emit field emission electron flux from the inner surface, so-called dark current. It may pass through the subsequent SRF cavity string and penetrate into the superconducting magnets placed downstream. It may heat up the superconducting coils, and may cause a quench. Therefore, further study on reliable conduction cooling and to secure the superconducting magnet operation with a keeping sufficient safety margin is quite essential. In this paper, we report the installation, the improvement achieved in STF, and the R&D progress in the study on the conduction cooling of the superconducting magnet for the ILC main linac.

43 PARTICLE ACCELERATORS↗

Aluminum Stabilized NbTi Conductor Test Coil Design, Fabrication, and Test Results

A new generation of precision muon conversion experiments is planned at both Fermilab and KEK. These experiments will depend upon a complex set of solenoid magnets for the production, momentum selection and transport of a muon beam to a stopping target, and for tracking detector momentum analysis of candidate conversion electrons from the target. Baseline designs for the production and detector solenoids use NbTi cable that is heavily stabilized by an extruded high RRR aluminum jacket. A U.S.-Japan research collaboration has begun whose goal is to advance the development of optimized Al-NbTi conductors, gain experience with the technology of winding coils from this material, and test the conductor performance as modest length samples become available. For this purpose, a 'conductor test' solenoid with three coils was designed and built at Fermilab. A sample of the RIKEN Al-NbTi conductor from KEK was wound into a 'test' coil; this was sandwiched between two 'field' coils wound from doubled SSC cable, to increase the peak field on the RIKEN test coil. All three solenoid coils were epoxy impregnated, and utilized aluminum outer bandage rings to apply preload to the coils when cold. The design and fabrication details, and results of the magnet quench performance tests are presented and discussed.

43 PARTICLE ACCELERATORS↗