Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Logs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

A Scientific Data Provenance Harvester for Distributed Applications

Data provenance provides a way for scientists to observe how experimental data originates, conveys process history, and explains influential factors such as experimental rationale and associated environmental factors from system metrics measured at runtime. The US Department of Energy Office of Science Integrated end-to-end Performance Prediction and Diagnosis for Extreme Scientific Workflows (IPPD) project has developed a provenance harvester that is capable of collecting observations from file based evidence typically produced by distributed applications. To achieve this, file based evidence is extracted and transformed into an intermediate data format inspired in part by W3C CSV on the Web recommendations, called the Harvester Provenance Application Interface (HAPI) syntax. This syntax provides a general means to pre-stage provenance into messages that are both human readable and capable of being written to a provenance store, Provenance Environment (ProvEn). HAPI is being applied to harvest provenance from climate ensemble runs for Accelerated Climate Modeling for Energy (ACME) project funded under the U.S. Department of Energy’s Office of Biological and Environmental Research (BER) Earth System Modeling (ESM) program. ACME informally provides provenance in a native form through configuration files, directory structures, and log files that contain success/failure indicators, code traces, and performance measurements. Because of its generic format, HAPI is also being applied to harvest tabular job management provenance from Belle II DIRAC scheduler relational database tables as well as other scientific applications that log provenance related information.

Stephan, Eric G.↗

A Butterfly-Accelerated Volume Integral Equation Solver for Broad Permittivity and Large-Scale Electromagnetic Analysis

In this work, a butterfly-accelerated volume integral equation (VIE) solver is proposed for fast and accurate electromagnetic (EM) analysis of scattering from heterogeneous objects. The proposed solver leverages the hierarchical off-diagonal butterfly (HOD-BF) scheme to construct the system matrix and obtain its approximate inverse, used as a preconditioner. Complexity analysis and numerical experiments validate the O(N log 2 N) construction cost of the HOD-BF-compressed system matrix and O(N log 1.5 N) inversion cost for the preconditioner, where N is the number of unknowns in the high-frequency EM scattering problem. For many practical scenarios, the proposed VIE solver requires less memory and computational time to construct the system matrix and obtain its approximate inverse compared to a H matrix-accelerated VIE solver. The accuracy and efficiency of the proposed solver have been demonstrated via its application to the EM analysis of large-scale canonical and real-world structures comprising of broad permittivity values and involving millions of unknowns.

42 ENGINEERING↗

GraphCH: A Deep Framework for Assessing Cyber-Human Aspects in Insider Threat Detection

Insider threat is one of the most damaging cyber attacks that could cause the loss of intellectual property and enterprise data security breaches. Action sequence data such as host logs are used to investigate such threats and develop anomaly-based AI detectors. However, insider threat actions are similar to legitimate user activities, causing AI detectors to fail and suffer from high false alarm rates. Therefore, user cyber activity logs are inadequate to fully unfold insider threats. In this study, we adopt human psychological principles of risk-taking and impulsiveness along with host data to assess the influence and usefulness of human behavioral aspects in insider threat detection. Here, we hypothesize that individuals' impulsive and risk-taking behavior correlates with cyberspace activities. To validate our hypothesis, we conducted an IRB-approved study recruiting 35 participants who work in a large U.S. university and collected their cyber and psychological data for 90 days. Host and human-behavioral data analysis and mapping indicate that impulsive and risk-taking users trigger more system errors causing (un)intentional insider threats and are susceptible to attackers' social engineering and cognitive hacking. Utilizing cyber-human aspects, we introduce a Cyber-Human Graph Neural Network (GNN) based framework GraphCH to identify abnormal user behaviors and detect insider threats.

97 MATHEMATICS AND COMPUTING↗

Investigating the Effects of Individual Neutron-Induced Defects in Bipolar Junction Transistors

Here, this study investigates neutron-induced displacement damage in Bipolar Junction Transistors (BJTs) using TCAD models informed by Deep-Level-Transient-Spectroscopy (DLTS) data. These models are calibrated and validated against experimental measurements performed at various neutron fluences. Both npn and pnp transistor configurations are studied to analyze the effects of individual traps on carrier recombination and base leakage currents. In npn transistors, deep traps (0.42 eV from the conduction band) dominate at low voltages, while shallow traps (0.17 eV from the conduction band) become prominent at higher voltages. Conversely, pnp transistors have base leakage current predominantly due to deep-level traps. The study observes a notable trend in trap density versus fluence, characterized by a linear relationship on a log-log scale. These insights into defect evolution under radiation conditions are crucial for optimizing semiconductor device reliability and performance in radiation-prone environments.

42 ENGINEERING↗

HIDES: Hybrid Intrusion Detector for Energy Systems

The establishment of a resilient electric grid accompanied by a secure communications network is an ongoing battle as advanced persistent threats continue to exploit existing vulnerabilities in legacy supervisory control and data acquisition system (SCADA) infrastructure. Traditional intrusion detection systems (IDSs) lack consistent performance because of the continuously evolving attack surface of SCADA systems. These shortcomings can be overcome by integrating logical system behavior, protocol-specific knowledge, and data-based learning to develop a comprehensive IDS solution. In this paper, we present a Hybrid Intrusion Detector for Energy Systems by integrating a network-based IDS, state-of-the-art machine learning-based IDS, and model-based IDS to detect unknown and stealthy cyberattacks targeting the SCADA networks. The proposed IDS uses synchrophasor measurements and cyber logs to learn patterns of different scenarios based on spatiotemporal behaviors of power systems. As a proof of concept, we implement and validate the proposed IDS by leveraging resources available at the National Renewable Energy Laboratory's Energy Systems Integration Facility test bed. Experimental results show promising performance in detecting cyberattacks while providing realtime visualization of power system measurements and cyber logs.

machine-learning intrusion detection system↗

Melting temperature measurement of refractory oxide ceramics as a function of oxygen fugacity using containerless methods

An aerodynamic conical nozzle levitator (CNL) has been used to measure the melting temperatures of refractory ceramics. The well-established method of cooling traces has been adapted to allow measurements for air-sensitive samples using a controlled atmosphere, where the oxygen partial pressure can be adjusted and monitored in real time. In this study, we explain the details of a system that we developed for use at the Spallation Neutron Source (Oak Ridge National Laboratory). Measurements of the melting behavior of (Fe,Cr,Al) 3 O 4 spinels were made between log (PO 2 (atm)) of -0.7 and -5. The melting temperature of hercynite is found to be oxygen potential dependent, ranging between 1692 and 1767°C at log (PO 2 ) values from -4.42 to -0.70.

36 MATERIALS SCIENCE↗

HIV influences clustering and intracellular replication of hepatitis C virus

We report HCV and HIV coinfection is common and HIV leads to increased HCV viraemia and accelerated disease progression. However, the biological basis of this interaction remains poorly understood and little is known about the impact of HIV on HCV replication at the cellular level. We analysed HCV RNA, based on single-cell laser-capture microdissection, in liver biopsies from monoinfected (n = 4) and HCV/HIV-coinfected (n = 5) participants. HCV RNA was assayed in 3200 hepatocytes with information of spatial position. We compared HCV RNA levels and clustering properties of infection between mono- and coinfected participants, and developed a mathematical model of infection. Although the median plasma HCV RNA level and the fraction of infected cells were comparable in monoinfected (7.0 log 10 IU/mL and ~ 30%) and coinfected (7.3 log 10 IU/mL and ~ 40%) participants, the median HCV RNA per infected hepatocyte in monoinfected (2.8IU) was significantly lower than in coinfected (8.2IU) participants (p = .03). Clustering of infected cells was more prominent in monoinfected participants (91% of samples) than in coinfected participants (~48%), p = .0045, suggesting that spatial spread may be influenced by HIV coinfection. Interestingly, when clustering does occur, the size of clusters is similar in both types of infection. A mathematical model of infection suggested that HIV allows higher intracellular accumulation of HCV RNA by impeding the export of HCV RNA. Our observations show that HIV coinfection impacts intracellular accumulation of HCV RNA and the clustering of HCV-infected cells, but to a less extent the fraction of HCV-infected cells.

59 BASIC BIOLOGICAL SCIENCES↗

SU-D-BRE-04: Evaluating the Dose Accuracy of a 2D Ion Chamber Array in High Dose Rate Pencil Beam Scanning Proton Beam

Purpose: To evaluate the absolute dose accuracy of the PTW Octavius 729 XDR 2D ion chamber array at a high dose rate pencil beam scanning proton therapy facility. Methods: A set of 18 plans were created in our treatment planning system, each of which comprising a unique combination of field sizes (FS), length of spread out of Bragg peaks (SOBP) and depths. The parameters used were: FS of 5×5cm{sup 2}, 10×10cm{sup 2} and 15×15cm{sup 2}; flat SOBP of 5cm and 10cm; and isocenter depths of 10cm, 15cm and 20cm, which coincides with the center of the SOBP. The 2D array detector was positioned at the machine isocenter and the appropriate amount of solid water was used to match the planned depths of 10, 15 and 20 cm water equivalent depth. Subsequently, we measured the absolute dose at isocenter using a CC04 ion chamber in a 1D water tank. Both 2D array and CC04 were previously cross calibrated. We also collected the MU rates used by our proton machine from the log files. Results: The relative differences between the CC04 and the 2D array can be summarized into two groups, one with 5 cm SOBP and another with 10 cm SOBP. Plotting these datasets against FS shows that the 2D array response for high dose rate fields (FS of 5×5cm{sup 2} and 5cm SOBP) can be up to 2% lower. Similarly, plotting them against isocenter depths reveals the detector's response can be up to 2% lower for higher energy beams (about 200MeV nominal). The MU rate found in the machine log files for 5cm SOBP's were as high as twice the MU rate for the 10cm SOBP. Conclusion: The 2D array dose response showed a dose rate effect in scanning pencil beam delivery, which needs to be corrected to achieve a better dose accuracy.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-100: Designing a QA Tool for Enhance Dynamic Wedges Based On Dynalog Files

Purpose: A robust quality assurance (QA) program for computer controlled enhanced dynamic wedge (EDW) has been designed and tested. Calculations to perform such QA test is based upon the EDW dynamic log files generated during dose delivery. Methods: Varian record and verify system generates dynamic log (dynalog) files during dynamic dose delivery. The system generated dynalog files contain information such as date and time of treatment, energy, monitor units, wedge orientation, and type of treatment. It also contains the expected calculated segmented treatment tables (STT) and the actual delivered STT for the treatment delivery as a verification record. These files can be used to assess the integrity and precision of the treatment plan delivery. The plans were delivered with a 6 MV beam from a Varian linear accelerator. For available EDW angles (10°, 15°, 20°, 25°, 30°, 45°, and 60°) Varian STT values were used to manually calculate monitor units for each segment. It can also be used to calculate the EDW factors. Independent verification of fractional MUs per segment was performed against those generated from dynalog files. The EDW factors used to calculate MUs in TPS were dosimetrically verified in solid water phantom with semiflex chamber on central axis. Results: EDW factors were generated from the STT provided by Varian and verified against practical measurements. The measurements were in agreement of the order of 1 % to the calculated EDW data. Variation between the MUs per segment obtained from dynalog files and those manually calculated was found to be less than 2%. Conclusion: An efficient and easy tool to perform routine QA procedure of EDW is suggested. The method can be easily implemented in any institution without a need for expensive QA equipment. An error of the order of ≥2% can be easily detected.

60 APPLIED LIFE SCIENCES↗

SU-E-T-406: Use of TrueBeam Developer Mode and API to Increase the Efficiency and Accuracy of Commissioning Measurements for the Varian EDGE Stereotactic Linac

Purpose: The Varian EDGE machine is a new stereotactic platform, combining Calypso and VisionRT localization systems with a stereotactic linac. The system includes TrueBeam DeveloperMode, making possible the use of XML-scripting for automation of linac-related tasks. This study details the use of DeveloperMode to automate commissioning tasks for Varian EDGE, thereby improving efficiency and measurement consistency. Methods: XML-scripting was used for various commissioning tasks,including couch model verification,beam-scanning,and isocenter verification. For couch measurements, point measurements were acquired for several field sizes (2×2,4×4,10×10cm{sup 2}) at 42 gantry angles for two couch-models. Measurements were acquired with variations in couch position(rails in/out,couch shifted in each of motion axes) compared to treatment planning system(TPS)-calculated values,which were logged automatically through advanced planning interface(API) scripting functionality. For beam scanning, XML-scripts were used to create custom MLC-apertures. For isocenter verification, XML-scripts were used to automate various Winston-Lutz-type tests. Results: For couch measurements, the time required for each set of angles was approximately 9 minutes. Without scripting, each set required approximately 12 minutes. Automated measurements required only one physicist, while manual measurements required at least two physicists to handle linac positions/beams and data recording. MLC apertures were generated outside of the TPS,and with the .xml file format, double-checking without use of TPS/operator console was possible. Similar time efficiency gains were found for isocenter verification measurements Conclusion: The use of XML scripting in TrueBeam DeveloperMode allows for efficient and accurate data acquisition during commissioning. The efficiency improvement is most pronounced for iterative measurements, exemplified by the time savings for couch modeling measurements(approximately 10 hours). The scripting also allowed for creation of the files in advance without requiring access to TPS. The API scripting functionality enabled efficient creation/mining of TPS data. Finally, automation reduces the potential for human error in entering linac values at the machine console,and the script provides a log of measurements acquired for each session. This research was supported in part by a grant from Varian Medical Systems, Palo Alto, CA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MO-G-BRE-04: Automatic Verification of Daily Treatment Deliveries and Generation of Daily Treatment Reports for a MR Image-Guided Treatment Machine

Purpose: Two aims of this work were to develop a method to automatically verify treatment delivery accuracy immediately after patient treatment and to develop a comprehensive daily treatment report to provide all required information for daily MR-IGRT review. Methods: After systematically analyzing the requirements for treatment delivery verification and understanding the available information from a novel MR-IGRT treatment machine, we designed a method to use 1) treatment plan files, 2) delivery log files, and 3) dosimetric calibration information to verify the accuracy and completeness of daily treatment deliveries. The method verifies the correctness of delivered treatment plans and beams, beam segments, and for each segment, the beam-on time and MLC leaf positions. Composite primary fluence maps are calculated from the MLC leaf positions and the beam-on time. Error statistics are calculated on the fluence difference maps between the plan and the delivery. We also designed the daily treatment delivery report by including all required information for MR-IGRT and physics weekly review - the plan and treatment fraction information, dose verification information, daily patient setup screen captures, and the treatment delivery verification results. Results: The parameters in the log files (e.g. MLC positions) were independently verified and deemed accurate and trustable. A computer program was developed to implement the automatic delivery verification and daily report generation. The program was tested and clinically commissioned with sufficient IMRT and 3D treatment delivery data. The final version has been integrated into a commercial MR-IGRT treatment delivery system. Conclusion: A method was developed to automatically verify MR-IGRT treatment deliveries and generate daily treatment reports. Already in clinical use since December 2013, the system is able to facilitate delivery error detection, and expedite physician daily IGRT review and physicist weekly chart review.

60 APPLIED LIFE SCIENCES↗

SU-C-BRE-06: Radiobiological Advantage of Very Rapid Irradiation

Purpose: To characterize the effect of very rapid dose delivery as compared to conventional therapeutic irradiation times on clonogenic cell survival. Methods: We used a Varian Trilogy linear accelerator to deliver doses up to 10 Gy using a 6 MV SRS photon beam. We irradiated four cancer cell lines in times ranging from 30 sec to 30 min. We also used a Varian TrueBeam linear accelerator to deliver 9 MeV electrons at 10 Gy in 10 s to 30 min to determine the effect of irradiation time on cell survival. We then evaluated the effect of using 60 and 120 MeV electrons on cell survival using the Next Linear Collider Test Accelerator (NLCTA) beam line at the SLAC National Accelerator Laboratory. During irradiation, adherent cells were maintained at 37oC with 20%O2/5%CO2. Clonogenic assays were completed following irradiation to determine changes in cell survival due to dose delivery time and beam quality, and the survival data were fitted with the linear-quadratic model. Results: Cell lines varied in radiosensitivity, ranging from two to four logs of cell kill at 10 Gy for both conventional and very rapid irradiation. Delivering radiation in shorter times decreased survival in all cell lines. Log differences in cell kill ranged from 0.2 to 0.7 at 10 Gy for the short compared to the long irradiation time. Cell kill differences between short and long irradiations were more pronounced as doses increased for all cell lines. Conclusion: Our findings suggest that shortening delivery of therapeutic radiation doses to less than 1 minute may improve tumor cell kill. This study demonstrates the potential advantage of technologies under development to deliver stereotactic ablative radiation doses very rapidly. Bill Loo and Peter Maxim have received Honoraria from Varian and Research Support from Varian and RaySearch.

60 APPLIED LIFE SCIENCES↗

Poster — Thur Eve — 30: 4D VMAT dose calculation methodology to investigate the interplay effect: experimental validation using TrueBeam Developer Mode and Gafchromic film

The interplay effect between the tumor motion and the radiation beam modulation during a VMAT treatment delivery alters the delivered dose distribution from the planned one. This work present and validate a method to accurately calculate the dose distribution in 4D taking into account the tumor motion, the field modulation and the treatment starting phase. A QUASAR™ respiratory motion phantom was 4D scanned with motion amplitude of 3 cm and with a 3 second period. A static scan was also acquired with the lung insert and the tumor contained in it centered. A VMAT plan with a 6XFFF beam was created on the averaged CT and delivered on a Varian TrueBeam and the trajectory log file was saved. From the trajectory log file 10 VMAT plans (one for each breathing phase) and a developer mode XML file were created. For the 10 VMAT plans, the tumor motion was modeled by moving the isocentre on the static scan, the plans were re-calculated and summed in the treatment planning system. In the developer mode, the tumor motion was simulated by moving the couch dynamically during the treatment. Gafchromic films were placed in the QUASAR phantom static and irradiated using the developer mode. Different treatment starting phase were investigated (no phase shift, maximum inhalation and maximum exhalation). Calculated and measured isodose lines and profiles are in very good agreement. For each starting phase, the dose distribution exhibit significant differences but are accurately calculated with the methodology presented in this work.

60 APPLIED LIFE SCIENCES↗

Sci—Sat AM: Stereo — 04: Evaluation of VMAT interplay effect for lung SABR using TrueBeam 10XFFF beam

During a VMAT treatment delivery, the interplay effect between the moving target and varying machine parameters result in dose distributions that are different from those initially planned. In this work, we investigate this effect for lung SABR by using 4D dose calculation derived from the Varian TrueBeam trajectory log file. The impact of treatment start phase is also evaluated. A QUASAR™ respiratory motion phantom was scanned with motion amplitudes of 0.4, 1, 2 and 3 cm with a 4 second period. MIP and the average dataset were generated from the 4DCT. A static CT was also acquired with the tumor in its centre position. Plans were optimized with 10X FFF beam until PTV and fictitious critical structures met the dose constraints. Ten temporally interleaved plans were constructed with the temporal machine parameter information from the trajectory log file. Ten plans were calculated with isocentre shifts to simulate respiratory motion and then summed. For each motion amplitude, three separate sum plans were created with various phase shifts (no phase shift, maximum inhalation and maximum exhalation) to assess the impact of treatment start phase. For all the phase shifts investigated, the DVH for PTV demonstrated good dose coverage. However, a careful review of slice by slice plan comparison indicates dose “holes” are observed within PTV. The PTV dose difference between various treatment start phases can be as high as 19%. This assumes all treatment fractions have identical treatment start phase. Our future work includes evaluation of interplay effect for various breathing periods.

60 APPLIED LIFE SCIENCES↗

Texture analysis on the fluence map to evaluate the degree of modulation for volumetric modulated arc therapy

Purpose: Texture analysis on fluence maps was performed to evaluate the degree of modulation for volumetric modulated arc therapy (VMAT) plans. Methods: A total of six textural features including angular second moment, inverse difference moment, contrast, variance, correlation, and entropy were calculated for fluence maps generated from 20 prostate and 20 head and neck VMAT plans. For each of the textural features, particular displacement distances (d) of 1, 5, and 10 were adopted. To investigate the deliverability of each VMAT plan, gamma passing rates of pretreatment quality assurance, and differences in modulating parameters such as multileaf collimator (MLC) positions, gantry angles, and monitor units at each control point between VMAT plans and dynamic log files registered by the Linac control system during delivery were acquired. Furthermore, differences between the original VMAT plan and the plan reconstructed from the dynamic log files were also investigated. To test the performance of the textural features as indicators for the modulation degree of VMAT plans, Spearman’s rank correlation coefficients (r{sub s}) with the plan deliverability were calculated. For comparison purposes, conventional modulation indices for VMAT including the modulation complexity score for VMAT, leaf travel modulation complexity score, and modulation index supporting station parameter optimized radiation therapy (MI{sub SPORT}) were calculated, and their correlations were analyzed in the same way. Results: There was no particular textural feature which always showed superior correlations with every type of plan deliverability. Considering the results comprehensively, contrast (d = 1) and variance (d = 1) generally showed considerable correlations with every type of plan deliverability. These textural features always showed higher correlations to the plan deliverability than did the conventional modulation indices, except in the case of modulating parameter differences. The r{sub s} values of contrast to the global gamma passing rates with criteria of 2%/2 mm, 2%/1 mm, and 1%/2 mm were 0.536, 0.473, and 0.718, respectively. The respective values for variance were 0.551, 0.481, and 0.688. In the case of local gamma passing rates, the r{sub s} values of contrast were 0.547, 0.578, and 0.620, respectively, and those of variance were 0.519, 0.527, and 0.569. All of the r{sub s} values in those cases were statistically significant (p < 0.003). In the cases of global and local gamma passing rates, MI{sub SPORT} showed the highest correlations among the conventional modulation indices. For global passing rates, r{sub s} values of MI{sub SPORT} were −0.420, −0.330, and −0.632, respectively, and those for local passing rates were −0.455, −0.490 and −0.502. The values of r{sub s} of contrast, variance, and MI{sub SPORT} with the MLC errors were −0.863, −0.828, and 0.795, respectively, all with statistical significances (p < 0.001). The correlations with statistical significances between variance and dose-volumetric differences were observed more frequently than the others. Conclusions: The contrast (d = 1) and variance (d = 1) calculated from fluence maps of VMAT plans showed considerable correlations with the plan deliverability, indicating their potential use as indicators for assessing the degree of modulation of VMAT plans. Both contrast and variance consistently showed better performance than the conventional modulation indices for VMAT.

60 APPLIED LIFE SCIENCES↗

SU-C-BRD-03: Closing the Loop On Virtual IMRT QA

Purpose: To develop an algorithm that predicts a priori IMRT QA passing rates. Methods: 416 IMRT plans from all treatment sites were planned in Eclipse version 11 and delivered using a dynamic sliding window technique on Clinac iX or TrueBeam linacs (Varian Medical Systems, Palo Alto, CA). The 3%/3mm and 2%/2mm local distance to agreement (DTA) were recorded during clinical operations using a commercial 2D diode array (MapCHECK 2, Sun Nuclear, Melbourne, FL). Each plan was characterized by 37 metrics that describe different failure modes between the calculated and measured dose. Machine-learning algorithms (MLAs) were trained to learn the relation between the plan characteristics and each passing rate. Minimization of the cross validated error, together with maximum a posteriori estimation (MAP), were used to choose the model parameters. Results: 3%/3mm local DTA can be predicted with an error smaller than 3% for 98% of the plans. For the remaining 2% of plans, the residual error was within 5%. For 2%/2mm local DTA passing rates, 96% percent of the plans were successfully predicted with an error smaller than 5%. All high-risk plans that failed the 2%/2mm local criteria were correctly identified by the algorithm. The most important metric to describe the passing rates was determined to be the MU per Gray (modulation factor). Conclusions: Logs files and independent dose calculations have been suggested as possible substitutes for measurement based IMRT QA. However, none of these methods answer the fundamental question of whether a plan can be delivered with a clinically acceptable error given the limitations of the linacs and the treatment planning system. Predicting the IMRT QA passing rates a priori closes that loop. For additional robustness, virtual IMRT QA can be combined with Linac QA and log file analysis to confirm appropriate delivery.

60 APPLIED LIFE SCIENCES↗

SU-E-T-67: A Quality Assurance Procedure for VMAT Delivery Technique with Multiple Verification Metric Using TG-119 Protocol

Purpose: A successful VMAT plan delivery includes precise modulations of dose rate, gantry rotational and multi-leaf collimator shapes. The purpose of this research is to construct routine QA protocol which focuses on VMAT delivery technique and to obtain a baseline including dose error, fluence distribution and mechanical accuracy during VMAT. Methods: The mock prostate, head and neck (HN) cases supplied from AAPM were used in this study. A VMAT plans were generated in Monaco TPS according to TG-119 protocol. Plans were created using 6 MV and 10 MV photon beams for each case. The phantom based measurement, fluence measurement and log files analysis were performed. The dose measurement was performed using 0.6 cc ion chamber, which located at isocenter. The fluence distribution were acquired using the MapCHECK2 mounted in the MapPHAN. The trajectory log files recorded inner 20 leaf pairs and gantry angle positions at every 0.25 sec interval were exported to in-house software developed by MATLAB and determined those RMS values. Results: The dose difference is expressed as a ratio of the difference between measured and planned doses. The dose difference for 6 MV was 0.91%, for 10 MV was 0.67%. In turn, the fluence distribution using gamma criteria of 2%/2 mm with a 50% minimum dose threshold for 6 MV was 98.8%, for 10 MV was 97.5%, respectively. The RMS values of MLC for 6 MV and 10 MV were 0.32 mm and 0.37 mm, of gantry were 0.33 degree and 0.31 degree. Conclusion: In this study, QA protocol to assess VMAT delivery accuracy is constructed and results acquired in this study are used as a baseline of VMAT delivery performance verification.

60 APPLIED LIFE SCIENCES↗

SU-E-T-464: Implementation and Validation of 4D Acuros XB Dose Calculations

Purpose: In this abstract we implement and validate a 4D VMAT Acuros XB dose calculation using Gafchromic film. Special attention is paid to the physical material assignment in the CT dataset and to reported dose to water and dose to medium. Methods: A QUASAR phantom with a 3 cm sinusoidal tumor motion and 5 second period was scanned using 4D computed tomography. A CT was also obtained of the static QUASAR phantom with the tumor at the central position. A VMAT plan was created on the average CT dataset and was delivered on a Varian TrueBeam linear accelerator. The trajectory log file from this treatment was acquired and used to create 10 VMAT subplans (one for each portion of the breathing cycle). Motion for each subplan was simulated by moving the beam isocentre in the superior/inferior direction in the Treatment Planning System on the static CT scan. The 10 plans were calculated (both dose to medium and dose to water) and summed for 1) the original HU values from the static CT scan and 2) the correct physical material assignment in the CT dataset. To acquire a breathing phase synchronized film measurements the trajectory log was used to create a VMAT delivery plan which includes dynamic couch motion using the Developer Mode. Three different treatment start phases were investigated (mid inhalation, full inhalation and full exhalation). Results: For each scenario the coronal dose distributions were measured using Gafchromic film and compared to the corresponding calculation with Film QA Pro Software using a Gamma test with a 3%/3mm distance to agreement criteria. Good agreement was found between calculation and measurement. No statistically significant difference in agreement was found between calculations to original HU values vs calculations to over-written (material-assigned) HU values. Conclusion: The investigated 4D dose calculation method agrees well with measurement.

60 APPLIED LIFE SCIENCES↗