Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Liquid flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Flight Metal Plasma Thruster (MPT) Development, Qualification, and Thrust Measurement Campaign

A torsional thrust stand, calibrated for impulse bits in the range of 0.1mNs -0.5 mNs, was used to measure impulse bits during two campaigns at the NASA/GRC VF-3 Vacuum test Facility. Metal Plasma Thrusters (MPTs) with targets of Molybdenum, Copper and Stainless Steel (as used in upper stages of launch vehicles that are abandoned in LEO) were tested. This paper describes data from Mo targets (called pucks). The Cu and ss data will be presented elsewhere. Model predictions (based on a simple circuit model and published plasma parameters) were validated by data from the calibrated torsional thrust stand. The Metal Plasma Thruster uses solid metal propellant, hence requires no liquids, gases, flow valves or flow controls and has no moving parts. Total impulse ~5000Ns/U provides orbit raising and drag compensation capability.

Electric Propulsion↗

Flight MPT Development, Qualification and Thrust Measurement Campaign

A torsional thrust stand, calibrated for impulse bits in the range of 0.1mNs -0.5 mNs, was used to measure impulse bits during two campaigns at the NASA/GRC VF-3 Vacuum test Facility. Metal Plasma Thrusters (MPTs) with targets of Molybdenum, Copper and Stainless Steel (as used in upper stages of launch vehicles that are abandoned in LEO) were tested. This paper describes data from Mo targets (called pucks). The Cu and ss data will be presented elsewhere. Model predictions (based on a simple circuit model and published plasma parameters) were validated by data from the calibrated torsional thrust stand. The Metal Plasma Thruster uses solid metal propellant, hence requires no liquids, gases, flow valves or flow controls and has no moving parts. Total impulse ~5000Ns/U provides orbit raising and drag compensation capability.

Electric Propulsion↗

Overview of Extractive and Optical PM Measurements from the NASA SE-5 High Pressure Flame Diagnostics Laboratory

Soot emissions measurements of multiphase non-premixed flames are sparse in the literature due to the complexities of sampling in such environments. We present an overview from on-going work at the NASA SE-5 High Pressure Flame Diagnostics laboratory focusing on soot and gaseous emissions at elevated pressures. SE-5 is a gaseous and liquid fueled high pressure flame tube facility capable of operating at pressures up to 880 psia, cooling capacity of 4,000,000 BTU/hr, liquid fuel flow rates up to 2 GPH, and an equivalence ratio range of 0.2 (fuel lean) to 4 (fuel rich). SE-5 provides optical access via four UV-grade fused silica optical windows of the primary reaction zone enabling non-intrusive optical diagnostics of the flame.

Soot↗

Refrigerant pressurization system with a two-phase condensing ejector

A refrigerant pressurization system including an ejector having a first conduit for flowing a liquid refrigerant therethrough and a nozzle for accelerating a vapor refrigerant therethrough. The first conduit is positioned such that the liquid refrigerant is discharged from the first conduit into the nozzle. The ejector includes a mixing chamber for condensing the vapor refrigerant. The mixing chamber comprises at least a portion of the nozzle and transitions into a second conduit having a substantially constant cross sectional area. The condensation of the vapor refrigerant in the mixing chamber causes the refrigerant mixture in at least a portion of the mixing chamber to be at a pressure greater than that of the refrigerant entering the nozzle and greater than that entering the first conduit.

42 ENGINEERING↗

Thermal management of long-length HTS cable systems

Projections of electric power production suggest a major shift to renewables, such as wind and solar, which will be in remote locations where massive quantities of power are available. One solution for transmitting this power over long distances to load centers is direct current (dc), high temperature superconducting (HTS) cables. Electric transmission via dc cables promises to be effective because of the low-loss, highcurrent- carrying capability of HTS wire at cryogenic temperatures. However, the thermal management system for the cable must be carefully designed to achieve reliable and energyefficient operation. Here we extend the analysis of a superconducting dc cable concept proposed by the Electric Power Research Institute (EPRI), which has one stream of liquid nitrogen flowing in a cryogenic enclosure that includes the power cable, and a separate return tube for the nitrogen. Refrigeration stations positioned every 10 to 20 km cool both nitrogen streams. Both go and return lines are contained in a single vacuum/cryogenic envelope. Other coolants, including gaseous helium and gaseous hydrogen, could provide potential advantages, though they bring some technical challenges to the operation of long-length HTS dc cable systems. A discussion of the heat produced in superconducting cables and a system to remove the heat are discussed. Also, an analysis of the use of various cryogenic fluids in long-distance HTS power cables is presented.

08 HYDROGEN↗

Modeling the dynamic behavior of proton-exchange membrane fuel cell

A two-phase transient model that incorporates the permanent hysteresis observed in the experimentally measured capillary pressure of GDL has been developed. The model provides explanation for the difference in time constant between membrane hydration and dehydration observed in the HFR experiment conducted at LANL. When there is liquid water at the cathode catalyst layer, time constant of the water content in the membrane is closely tied to that of liquid water saturation in the CCL, as the vapor is already saturated. The water content in the membrane will not reach steady state as long as the liquid water flow in the CCL is not at steady state. Also, Increased resistance to proton transport in the membrane is observed when the cell voltage is stepped down to a very low value.

30 DIRECT ENERGY CONVERSION↗

Microfluidic process monitor for industrial solvent extraction system

The present invention provides a system for solvent extraction utilizing a first electrode with a raised area formed on its surface, which defines a portion of a microfluidic channel; a second electrode with a flat surface, defining another portion of the microfluidic channel that opposes the raised area of the first electrode; a reversibly deformable substrate disposed between the first electrode and second electrode, adapted to accommodate the raised area of the first electrode and having a portion that extends beyond the raised area of the first electrode, that portion defining the remaining portions of the microfluidic channel; and an electrolyte of at least two immiscible liquids that flows through the microfluidic channel. Also provided is a system for performing multiple solvent extractions utilizing several microfluidic chips or unit operations connected in series.

42 ENGINEERING↗

Method for solid-liquid separations

Devices, systems, and methods are disclosed to separate solids from liquids. A vessel includes a screw, an inlet, a first outlet, and a second outlet. The inlet receives a first slurry having an incoming solids concentration. The first slurry consists of solids and a contact liquid. The first outlet is disposed toward the first end of the vessel. The second outlet is disposed toward a second end of the vessel. The screw preferentially conveys the solids over the contact liquid towards the second end of the vessel, the solids displacing at least a portion of the contact liquid, causing that portion of the contact liquid to flow toward the first outlet. A melting device is included.

Baxter, Larry↗

The developments and verifications of trace model for IIST LOCA experiments

The test facility IIST (INER Integral System Test) is a Reduced-Height and Reduced-Pressure (RHRP) integral test loop, which was constructed for the purposes of conducting thermal hydraulic and safety analysis of the Westinghouse three-loop PWR Nuclear Power Plants. The main purpose of this study is to develop and verify TRACE models of IIST through the IIST small break loss of coolant accident (SBLOCA) experiments. First, two different IIST TRACE models which include a pipe-vessel model and a 3-D vessel component model have been built. The steady state and transient calculation results show that both TRACE models have the ability to simulate the related IIST experiments. Comparing with IIST SBLOCA experiment data, the 3-D vessel component model has shown better simulation capabilities so that it has been chosen for all further thermal hydraulic studies. The second step is the sensitivity studies of two phase multiplier and subcooled liquid multiplier in choked flow model; and two correlation constants in CCFL model respectively. As a result, an appropriate set of multipliers and constants can be determined. In summary, a verified IIST TRACE model with 3D vessel component, and fine-tuned choked flow model and CCFL model is established for further studies on IIST experiments in the future. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Oxidative Degradation of Organic Compounds from Sludge by Ozonation: Study of Process - 19191

This study investigates the performance of the ozonation process in the treatment of petroleum sludge from an offshore production platform situated in Brazil. The effect of operating conditions is studied such as the phase to be treated and the sludge/water ratio. Total organic carbon content increased in O{sub 2} and O{sub 3} experiments, mainly because of the mixing factor. The decrease of sludge mass was observed in a situation of forced mixing and with only ozone flow. The liquid phase indicated a high TOC value, but very low radioactive activities, whereas the solid phase did not present detectable TOC amounts but significant values of radioactive activity. More experiments and analyzes will be carried out to obtain more relevant results for future discussion. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Residual Dose Rates Analyses from Vent Lines Shield Block on the Target Cart at Spallation Neutron Source

The target carriage supports the mercury target vessel in the Spallation Neutron Source (SNS) in a cantilevered fashion and supplies the liquid mercury flowing to and from the target vessel. The target carriage is designed to move the target vessel into its target monolith position to receive the proton beam and then remove it horizontally back into an adjacent service cell, where the target vessel can be exchanged about 2-3 times per calendar year. At the time of the performed studies, the SNS mercury target can accept a proton beam at 1 GeV energy and 1.4 MW power; however, it will be upgraded to receive 1.3 GeV energy at 2 MW by the end of 2024 year [1]. The cart is practically a shield block on wheels to minimize fluxes and dose rates in the service cell downstream of the carriage. There are vent lines located inside a passage on top of the target carriage, and they are covered by a stepping-up steel shield block (vent lines shield block). Vent lines are permanently attached to the shield block. New vent lines with a different design are going to be installed. These lines are shielded by the new steel block to which the vent lines are attached. The estimate of the residual dose rates from the block after it is extracted from the target carriage is performed to estimate the radiation fields and to decide on the type of storage container to be used.

Popova, Irina I↗

Combustor assembly for low-emissions and alternate liquid fuels

Implementations of a combustor assembly yield low emissions, require low power, are suitable for alternate liquid fuels, including highly viscous fuels, and are scalable for various heat release rates. The combustor assembly includes a fuel injector and a swirler. The fuel injector may include a choke portion and a spacer. The choke portion is disposed just upstream of an outlet of a liquid fuel conduit and prevents atomizing gas from interrupting continuous flow of the liquid fuel through the liquid fuel conduit. The spacer is disposed downstream of the outlet to precisely control the gap and thus, bifurcation of atomizing gas flow, between the outlet of liquid fuel conduit and an inlet of an orifice plate. The swirler is disposed radially outwardly and adjacent the fuel injector and includes a plurality of angled vanes.

42 ENGINEERING↗