Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Linearization error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Polarization of prompt J/{psi} in proton-proton collisions at RHIC

Within the framework of the nonrelativistic QCD (NRQCD) factorization approach, we compute the polarization of prompt J/{psi} produced at the Brookhaven's Relativistic Heavy-Ion Collider from proton-proton collisions at the center-of-momentum energy {radical}(s)=200 GeV. The perturbative contributions are computed at leading order in the strong coupling constant. The prediction reveals that the color-singlet contribution severely underestimates the PHENIX preliminary data for the differential cross section integrated over the rapidity range |y|<0.35 and its contribution is strongly transversely polarized, which disagrees with the PHENIX preliminary data. After including the color-octet contributions, we find that the NRQCD predictions for both the cross section and polarization over the transverse-momentum range 1.5 GeV<p{sub T}<5 GeV (1.5 GeV<p{sub T}<2 GeV) integrated over the rapidity range |y|<0.35 (1.2<|y|<2.2) agree with the data within errors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of CP observables in B{sup {+-}{yields}D}{sub CP}K{sup {+-}}decays and constraints on the CKM angle {gamma}

Using the entire sample of 467x10{sup 6} {Upsilon}(4S){yields}BB decays collected with the BABAR detector at the PEP-II asymmetric-energy B factory at the SLAC National Accelerator Laboratory, we perform an analysis of B{sup {+-}}{yields}DK{sup {+-}}decays, using decay modes in which the neutral D meson decays to either CP-eigenstates or non-CP-eigenstates. We measure the partial decay rate charge asymmetries for CP-even and CP-odd D final states to be A{sub CP+}=0.25{+-}0.06{+-}0.02 and A{sub CP-}=-0.09{+-}0.07{+-}0.02, respectively, where the first error is the statistical and the second is the systematic uncertainty. The parameter A{sub CP+} is different from zero with a significance of 3.6 standard deviations, constituting evidence for direct CP violation. We also measure the ratios of the charged-averaged B partial decay rates in CP and non-CP decays, R{sub CP+}=1.18{+-}0.09{+-}0.05 and R{sub CP-}=1.07{+-}0.08{+-}0.04. We infer frequentist confidence intervals for the angle {gamma} of the unitarity triangle, for the strong phase difference {delta}{sub B}, and for the amplitude ratio r{sub B}, which are related to the B{sup -}{yields}DK{sup -} decay amplitude by r{sub B}e{sup i({delta}{sub B}-{gamma})}=A(B{sup -}{yields}D{sup 0}K{sup -})/A(B{sup -}{yields}D{sup 0}K{sup -}). Including statistical and systematic uncertainties, we obtain 0.24<r{sub B}<0.45 (0.06<r{sub B}<0.51) and, modulo 180 deg., 11.3 deg. <{gamma}<22.7 deg. or 80.8 deg. <{gamma}<99.2 deg. or 157.3 deg. <{gamma}<168.7 deg. (7.0 deg. <{gamma}<173.0 deg.) at the 68% (95%) confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Unscented Kalman Filter-based Unbiased Minimum-Variance Estimation for Nonlinear Systems with Unknown Inputs

This paper proposes an unscented Kalman filter (UKF)-based unbiased minimum-variance estimation (UMV) method for the nonlinear system with unknown inputs. By utilizing the statistical linerization, the nonlinear system and measurement functions are transformed into a “linear-like” regression form. The latter preserves the nonlinearity of the system and the measurement models. To this end, the unknown inputs can be estimated by the weighted least-squares. This “linear-like” regression form also allows us to resort to the UMV state estimation framework for the development of new nonlinear filter to handle unknown inputs. Specifically, two approaches have been developed: 1) given the estimated inputs, we derive a filter by minimizing the trace of the state error covariance matrix; 2) without input estimation, we derive the filter by minimizing the trace of the state error covariance matrix subject to a constraint imposed on the gain matrix. We prove that these two approaches provide the same results. Numerical results validate the effectiveness of the proposed method.

Unscented Kalman filter, unbiased minimumvariance ↗

Analog In-Memory Computing for the Synthetic Aperture Radar Polar Format Algorithm

As the utility of synthetic aperture radar (SAR) systems increases in autonomous vehicles, satellites, and other power- and space-constrained edge applications, there is a growing need for processors that can form SAR images at low power. In recent years, analog in-memory compute (AIMC) has shown immense promise for accelerating neural networks and other matrix-vector multiplication (MVM) heavy workloads at the edge. Here, in this work, we examine how the polar format algorithm (PFA), a popular SAR image formation algorithm, can be mapped to these AIMC systems. The PFA maps readily onto analog MVMs because it primarily consists of two linear operations: interpolation of frequency-domain data to a Cartesian grid, followed by a 2-D Fourier transform. This work presents two approaches to map the interpolation operation onto MVMs in analog hardware: a chirp transform and a modified form of sinc interpolation. These mappings introduce algorithmic errors, and their effect on the quality of SAR image formation is examined, both quantitatively and qualitatively. In addition, the impact of errors introduced by the analog hardware is explored to determine which approach is optimal under varying assumptions about the underlying analog memory devices and circuits.

Analog computing↗

SU-F-T-445: Effect of Triaxial Cables and Microdetectors in Small Field Dosimetry

Purpose: Advances in radiation treatment especially with smaller fields used in SRS, Gamma knife, Tomotherapy, Cyberknife, and IMRT, require a high degree of precision especially with microdetectors for small field dosimetry (Das et al, Med Ph, 35, 206, 2008; Alfonso et al, Med Phys, 35, 5179, 2008). Due to small signal, the triaxial cable becomes critical in terms of signal to noise ratio (SNR) which is studied with microdetectors. Methods: Six high quality triaxial cables, 9.1 meters long from different manufacturers without any defects were acquired along with 5 most popular microdetectors (microdiamond, plastic scintillators, SRS-diode, edge-diode and pinpoint). A dedicated electrometer was used for each combination except W1 which has its own supermax electrometer. A 6MV photon beam from Varian True beam with 100 MU at a 600 MU/min was used. Measurements were made at a depth of 5 cm in water phantom. Field sizes were varied from 0.5 cm to 10 cm square fields. Readings were taken with combination of cables and microdetectors. Results: Signal is dependent on the quality of the connectors, cables and types of microdetector. The readings varied from nC to pC depending on the type of microdetector. The net signal, S, (Sc-Sn), where Sc is signal with chamber and Sn is without chamber is a linear function of sensitive volume, v; (S = α+β•V), where α and β are constants. The standard deviation (SD) in 3 sets of reading with each combination of cable-detector was extremely low <0.02%. As expected the SD is higher in small fields (<3cm). Maximum estimated error was only ±0.2% in cables-detector combinations. Conclusion: The choice of cables has relatively small effect (±0.2%) with microdosimeter and should be accounted in overall error estimation in k value that is needed to convert ratio of reading to dose in small field dosimetry.

60 APPLIED LIFE SCIENCES↗

iTOUGH2 v7.1

iTOUGH2 (inverse TOUGH2) provides inverse modeling capabilities for TOUGH2, a simulator for multi-dimensional, multi-phase, multi-component, non-isothermal flow and transport in fractured porous media. iTOUGH2 performs sensitivity analyses, data-worth analyses, parameter estimation, and uncertainty propagation analyses in geosciences and reservoir engineering and other application areas. iTOUGH2 supports a number of different combinations of fluids and components (equation-of-state (EOS) modules). In addition, the optimization routines implemented in iTOUGH2 can also be used for sensitivity analysis, automatic model calibration, and uncertainty quantification of any external code that uses text-based input and output files using the PEST protocol. iTOUGH2 solves the inverse problem by minimizing a non-linear objective function of the weighted differences between model output and the corresponding observations. Multiple minimization algorithms (derivative-free, gradient-based, and second-order; local and global) are available. iTOUGH2 also performs Latin Hypercube Monte Carlo simulations for uncertainty propagation analyses. A detailed residual and error analysis is provided. This upgrade includes (a) global sensitivity analysis methods, (b) dynamic memory allocation (c) additional input features and output analyses, (d) increased forward simulation capabilities, (e) parallel execution on multicore PCs and Linux clusters, and (f) bug fixes.

Finsterle, Stefan↗

Photonic-bandgap-fiber sensors for gas detection

Currently, the technology available for rapid detection and characterization of different gaseous species is limited. Existing methods are either too slow or too error-prone to allow the real-time analysis of similar gasses in a mixture. Although marginal success has been reported using other techniques, we believe that Raman spectroscopy possesses the clearest capabilities to serve as a gas sensing tool. Because spontaneous Raman spectroscopy produces signals which vary linearly with gas concentration, and Raman spectra are unique to individual molecules, this technique provides both concentration and definitive identification information. Unfortunately, Raman crosssections for most gasses of interest are extremely small and detected powers are usually tiny.

99 GENERAL AND MISCELLANEOUS↗

GREAT3 results - I. Systematic errors in shear estimation and the impact of real galaxy morphology

The study present first results from the third GRavitational lEnsing Accuracy Testing (GREAT3) challenge, the third in a sequence of challenges for testing methods of inferring weak gravitational lensing shear distortions from simulated galaxy images. GREAT3 was divided into experiments to test three specific questions, and included simulated space- and ground-based data with constant or cosmologically varying shear fields. The simplest (control) experiment included parametric galaxies with a realistic distribution of signal-to-noise, size, and ellipticity, and a complex point spread function (PSF). The other experiments tested the additional impact of realistic galaxy morphology, multiple exposure imaging, and the uncertainty about a spatially varying PSF; the last two questions will be explored in Paper II. The 24 participating teams competed to estimate lensing shears to within systematic error tolerances for upcoming Stage-IV dark energy surveys, making 1525 submissions overall. GREAT3 saw considerable variety and innovation in the types of methods applied. Several teams now meet or exceed the targets in many of the tests conducted (to within the statistical errors). We conclude that the presence of realistic galaxy morphology in simulations changes shear calibration biases by ~1 per cent for a wide range of methods. Other effects such as truncation biases due to finite galaxy postage stamps, and the impact of galaxy type as measured by the Sérsic index, are quantified for the first time. Our results generalize previous studies regarding sensitivities to galaxy size and signal-to-noise, and to PSF properties such as seeing and defocus. Almost all methods’ results support the simple model in which additive shear biases depend linearly on PSF ellipticity.

79 ASTRONOMY AND ASTROPHYSICS↗

Reduced‐Order Modeling for Linearized Representations of Microphysical Process Rates

Abstract Representing cloud microphysical processes in large scale atmospheric models is challenging because many processes depend on the details of the droplet size distribution (DSD, the spectrum of droplets with different sizes in a cloud). While full or partial statistical moments of droplet size distributions are the typical variables used in bulk models, prognostic moments are limited in their ability to represent microphysical processes across the range of conditions experienced in the atmosphere. Microphysical parameterizations employing prognostic moments are known to suffer from structural uncertainty in their representations of inherently higher dimensional cloud processes, which limit model fidelity and lead to forecasting errors. Here we investigate how data‐driven reduced‐order modeling can be used to learn predictors for microphysical process rates in bulk microphysics schemes in an unsupervised manner from higher dimensional bin distributions. Using simulations characteristic of marine stratiform clouds, we simultaneously learn lower dimensional representations of droplet size distributions and predict the evolution of the microphysical state of the system. Droplet collision‐coalescence, the main process for generating warm rain, is estimated to have an intrinsic dimension of three. This intrinsic dimension provides a lower limit on the number of degrees of freedom needed to accurately represent collision‐coalescence in models. We demonstrate how deep learning based reduced‐order modeling can be used to discover intrinsic coordinates describing the microphysical state of the system, where process rates such as collision‐coalescence are globally linearized. These implicitly learned representations of the DSD retain more information about the DSD than typical moment‐based representations.

54 ENVIRONMENTAL SCIENCES↗

PRIMORDIAL GRAVITATIONAL WAVE DETECTABILITY WITH DEEP SMALL-SKY COSMIC MICROWAVE BACKGROUND EXPERIMENTS

We use the Bayesian estimation on direct T - Q - U cosmic microwave background (CMB) polarization maps to forecast errors on the tensor-to-scalar power ratio r, and hence on primordial gravitational waves, as a function of sky coverage f{sub sky}. This map-based likelihood filters the information in the pixel-pixel space into the optimal combinations needed for r detection for cut skies, providing enhanced information over a first-step linear separation into a combination of E, B, and mixed modes, and ignoring the latter. With current computational power and for typical resolutions appropriate for r detection, the large matrix inversions required are accurate and fast. Our simulations explore two classes of experiments, with differing bolometric detector numbers, sensitivities, and observational strategies. One is motivated by a long duration balloon experiment like Spider, with pixel noise {proportional_to}{radical}(f{sub sky}) for a specified observing period. This analysis also applies to ground-based array experiments. We find that, in the absence of systematic effects and foregrounds, an experiment with Spider-like noise concentrating on f{sub sky} {approx} 0.02-0.2 could place a 2{sigma}{sub r} Almost-Equal-To 0.014 boundary ({approx}95% confidence level), which rises to 0.02 with an l-dependent foreground residual left over from an assumed efficient component separation. We contrast this with a Planck-like fixed instrumental noise as f{sub sky} varies, which gives a Galaxy-masked (f{sub sky} = 0.75) 2{sigma}{sub r} Almost-Equal-To 0.015, rising to Almost-Equal-To 0.05 with the foreground residuals. Using as the figure of merit the (marginalized) one-dimensional Shannon entropy of r, taken relative to the first 2003 WMAP CMB-only constraint, gives -2.7 bits from the 2012 WMAP9+ACT+SPT+LSS data, and forecasts of -6 bits from Spider (+ Planck); this compares with up to -11 bits for CMBPol, COrE, and PIXIE post-Planck satellites and -13 bits for a perfectly noiseless cosmic variance limited experiment. We thus confirm the wisdom of the current strategy for r detection of deeply probed patches covering the f{sub sky} minimum-error trough with balloon and ground experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

The use of RapidArc volumetric-modulated arc therapy to deliver stereotactic radiosurgery and stereotactic body radiotherapy to intracranial and extracranial targets

Twenty-three targets in 16 patients treated with stereotactic radiosurgery (SRS) or stereotactic body radiotherapy (SBRT) were analyzed in terms of dosimetric homogeneity, target conformity, organ-at-risk (OAR) sparing, monitor unit (MU) usage, and beam-on time per fraction using RapidArc volumetric-modulated arc therapy (VMAT) vs. multifield sliding-window intensity-modulated radiation therapy (IMRT). Patients underwent computed tomography simulation with site-specific immobilization. Magnetic resonance imaging fusion and optical tracking were incorporated as clinically indicated. Treatment planning was performed using Eclipse v8.6 to generate sliding-window IMRT and 1-arc and 2-arc RapidArc plans. Dosimetric parameters used for target analysis were RTOG conformity index (CI{sub RTOG}), homogeneity index (HI{sub RTOG}), inverse Paddick Conformity Index (PCI), D{sub mean} and D5-D95. OAR sparing was analyzed in terms of D{sub max} and D{sub mean}. Treatment delivery was evaluated based on measured beam-on times delivered on a Varian Trilogy linear accelerator and recorded MU values. Dosimetric conformity, homogeneity, and OAR sparing were comparable between IMRT, 1-arc RapidArc and 2-arc RapidArc plans. Mean beam-on times {+-} SD for IMRT and 1-arc and 2-arc treatments were 10.5 {+-} 7.3, 2.6 {+-} 1.6, and 3.0 {+-} 1.1 minutes, respectively. Mean MUs were 3041, 1774, and 1676 for IMRT, 1-, and 2-arc plans, respectively. Although dosimetric conformity, homogeneity, and OAR sparing were similar between these techniques, SRS and SBRT fractions treated with RapidArc were delivered with substantially less beam-on time and fewer MUs than IMRT. The rapid delivery of SRS and SBRT with RapidArc improved workflow on the linac with these otherwise time-consuming treatments and limited the potential for intrafraction organ and patient motion, which can cause significant dosimetric errors. These clinically important advantages make image-guided RapidArc useful in the delivery of SRS and SBRT to intracranial and extracranial targets.

61 RADIATION PROTECTION AND DOSIMETRY↗

Emulating galaxy and peculiar velocity clustering on non-linear scales

We explore the potential of cross-correlating galaxies and peculiar velocities on non-linear scales to enhance cosmological constraints. Leveraging the ABACUSSUMMIT simulation suite and the halo occupation distribution (HOD) formalism, we trained emulator models to describe the non-linear clustering of galaxies and velocities in redshift space. Our analysis demonstrates that combining galaxy and peculiar velocity clustering provides tighter constraints on both HOD and cosmological parameters, particularly on σ8 and w0. We further applied our models to realistic mock catalogues, reproducing the expected density and peculiar velocity errors of type-Ia supernovae, Tully-Fisher and fundamental plane measurements for the combined ZTF and DESI measurements. While systematic biases arise in the HOD parameters, the cosmological constraints remain unbiased, yielding a 3.8% precision measurement on fσ 8 compared to 4.7% when using galaxy clustering alone. We demonstrate that while combining tracers with realistic velocity measurements still yields an improvement, the gains are diminished, highlighting the need for further efforts to reduce velocity measurement uncertainties and correct observational systematics on small scales.

79 ASTRONOMY AND ASTROPHYSICS↗

Simulating the JET ITER-like Antenna circuit

A set of simulation/interpretation tools based on transmission line theory and on the RF model developed by M. Vrancken has been developed to study the ITER-like Antenna (ILA) at JET. For given tuning element settings, the unique solution of the equations governing the ILA circuit requires solving a system of coupled linear equations relating the voltages and currents at the antenna straps and other key locations. This computation allows cross-checking predicted values against measured experimental ones. Further more, a minimization procedure allows improving the correspondence with the quantities measured in the circuit during shots, thus coping with unavoidable errors arising from uncertainties in the measurements or from inaccuracies in the adopted RF model. Typical applications are e.g. fine-tuning of the second-stage of the ILA circuit for increased ELM-resilience, cross-checking the calibration of the measurements throughout the circuit and predicting the antenna performance and matching conditions in new plasma scenarios.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MATCHING THE SPECTRAL ENERGY DISTRIBUTION AND p-MODE OSCILLATION FREQUENCIES OF THE RAPIDLY ROTATING DELTA SCUTI STAR {alpha} OPHIUCHI WITH A TWO-DIMENSIONAL ROTATING STELLAR MODEL

Spectral energy distributions are computed using two-dimensional (2D) rotating stellar models and non-LTE plane-parallel model atmospheres. A rotating, 2D stellar model has been found that matches the observed ultraviolet and visible spectrum of {alpha} Oph. The SED match occurs for the interferometrically deduced surface shape and inclination, and is different from the SED produced by spherical models. The p-mode oscillation frequencies in which the latitudinal variation is modeled by a linear combination of eight Legendre polynomials were computed for this model. The five highest and seven of the nine highest amplitude modes show agreement between computed axisymmetric, equatorially symmetric mode frequencies and the mode frequencies observed by the Microvariability and Oscillations of Stars satellite (MOST) to within the observational error. Including nonaxisymmetric modes up through |m| = 2, and allowing for the possibility that the eight lowest amplitude modes could be produced by modes that are not equatorially symmetric, matches for 24 out of the 35 MOST modes to within the observational error and another eight modes to within twice the observational error. The remaining three observed modes can be fitted within 4.2 times the observational error, but even these may be fitted to within the observational error if the criteria for computed modes are expanded.

79 ASTRONOMY AND ASTROPHYSICS↗

Bayesian High-Rank Hankel Matrix Completion for Nonlinear Synchrophasor Data Recovery

Phasor measurement units (PMUs) provide high temporal-resolution synchrophasor measurements for power system monitoring and control. The frequent data quality issues, such as missing and bad data, prevent the incorporation of synchrophasor data in real-time operations. Most existing data-driven data recovery methods assume the power system dynamics can be approximated by a linear dynamical system, and the recovery performance degrades significantly when the power system is experiencing nonlinear dynamics during significant events. Here, this paper proposes a data-driven Bayesian nonlinear synchrophasor data recovery method (Ba-NSDR) that can recover a consecutive time period of simultaneous data losses or errors across all channels, even when the underlying system is highly nonlinear. The idea is to lift the Hankel matrix of the spatial-temporal synchrophasor data to a higher dimension such that the lifted Hankel matrix is low-rank in that space and can be processed with the kernel trick. Our proposed Bayesian method then infers the probabilistic distributions of synchrophasor from the partial observations. Some distinctive features of Ba-NSDR include an uncertainty index to measure the accuracy of the recovery result and the robustness to parameter selections. Our method is verified on both synthetic and recorded event datasets.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Objective models of compressed breast shapes undergoing mammography

Purpose: To develop models of compressed breasts undergoing mammography based on objective analysis, that are capable of accurately representing breast shapes in acquired clinical images and generating new, clinically realistic shapes. Methods: An automated edge detection algorithm was used to catalogue the breast shapes of clinically acquired cranio-caudal (CC) and medio-lateral oblique (MLO) view mammograms from a large database of digital mammography images. Principal component analysis (PCA) was performed on these shapes to reduce the information contained within the shapes to a small number of linearly independent variables. The breast shape models, one of each view, were developed from the identified principal components, and their ability to reproduce the shape of breasts from an independent set of mammograms not used in the PCA, was assessed both visually and quantitatively by calculating the average distance error (ADE). Results: The PCA breast shape models of the CC and MLO mammographic views based on six principal components, in which 99.2% and 98.0%, respectively, of the total variance of the dataset is contained, were found to be able to reproduce breast shapes with strong fidelity (CC view mean ADE = 0.90 mm, MLO view mean ADE = 1.43 mm) and to generate new clinically realistic shapes. The PCA models based on fewer principal components were also successful, but to a lesser degree, as the two-component model exhibited a mean ADE = 2.99 mm for the CC view, and a mean ADE = 4.63 mm for the MLO view. The four-component models exhibited a mean ADE = 1.47 mm for the CC view and a mean ADE = 2.14 mm for the MLO view. Paired t-tests of the ADE values of each image between models showed that these differences were statistically significant (max p-value = 0.0247). Visual examination of modeled breast shapes confirmed these results. Histograms of the PCA parameters associated with the six principal components were fitted with Gaussian distributions. The six-component model was also used to generate CC and MLO view mammogram breast shapes, using the mean PCA parameter values of these distributions and randomly generated values based on the fitted Gaussian distributions, which resemble clinically encountered breasts. A spreadsheet with the data necessary to apply this model is provided as the supplementary material. Conclusions: Our PCA models of breast shapes in both mammographic views successfully reproduce analyzed breast shapes and generate new clinically relevant shapes. This work can aid in research applications which incorporate breast shape modeling, such as x-ray scatter correction, dosimetry, and image registration.

60 APPLIED LIFE SCIENCES↗

A method for volumetric imaging in radiotherapy using single x-ray projection

Purpose: It is an intriguing problem to generate an instantaneous volumetric image based on the corresponding x-ray projection. The purpose of this study is to develop a new method to achieve this goal via a sparse learning approach. Methods: To extract motion information hidden in projection images, the authors partitioned a projection image into small rectangular patches. The authors utilized a sparse learning method to automatically select patches that have a high correlation with principal component analysis (PCA) coefficients of a lung motion model. A model that maps the patch intensity to the PCA coefficients was built along with the patch selection process. Based on this model, a measured projection can be used to predict the PCA coefficients, which are then further used to generate a motion vector field and hence a volumetric image. The authors have also proposed an intensity baseline correction method based on the partitioned projection, in which the first and the second moments of pixel intensities at a patch in a simulated projection image are matched with those in a measured one via a linear transformation. The proposed method has been validated in both simulated data and real phantom data. Results: The algorithm is able to identify patches that contain relevant motion information such as the diaphragm region. It is found that an intensity baseline correction step is important to remove the systematic error in the motion prediction. For the simulation case, the sparse learning model reduced the prediction error for the first PCA coefficient to 5%, compared to the 10% error when sparse learning was not used, and the 95th percentile error for the predicted motion vector was reduced from 2.40 to 0.92 mm. In the phantom case with a regular tumor motion, the predicted tumor trajectory was successfully reconstructed with a 0.82 mm error for tumor center localization compared to a 1.66 mm error without using the sparse learning method. When the tumor motion was driven by a real patient breathing signal with irregular periods and amplitudes, the average tumor center error was 0.6 mm. The algorithm robustness with respect to sparsity level, patch size, and presence or absence of diaphragm, as well as computation time, has also been studied. Conclusions: The authors have developed a new method that automatically identifies motion information from an x-ray projection, based on which a volumetric image is generated.

60 APPLIED LIFE SCIENCES↗

The fully nonconforming virtual element method for biharmonic problems

Here in this paper, we address the numerical approximation of linear fourth-order elliptic problems on polygonal meshes. In particular, we present a novel nonconforming virtual element discretization of arbitrary order of accuracy for biharmonic problems. The approximation space is made of possibly discontinuous functions, thus giving rise to the fully nonconforming virtual element method. We derive optimal error estimates in a suitable (broken) energy norm and present numerical results to assess the validity of the theoretical estimates.

97 MATHEMATICS AND COMPUTING↗