Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Linear accelerator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Conceptual Design for the New RPI 2020 Linac

The Rensselaer Polytechnic Institute (RPI) spectrometer is an installation based on an L-band linear accelerator designed and installed many decades ago. While this installation has served many important experiments over the decades, a new more powerful and more flexible linac to serve a wider range of experiments is envisioned as an upgrade to the existing installation by 2020.

47 OTHER INSTRUMENTATION↗

Mercury Thermal Hydraulic Loop (MTHL) Summary Report

The Spallation Neutron Source (SNS) is a high-power linear accelerator built at Oak Ridge National Laboratory (ORNL) which incorporates the use of a flowing liquid mercury target. The Mercury Thermal Hydraulic Loop (MTHL) was constructed to investigate and verify the heat transfer characteristics of liquid mercury in a rectangular channel. This report provides a compilation of previously reported results from the water-cooled and electrically heated straight and curved test sections that simulate the geometry of the window cooling channel in the target nose region.

43 PARTICLE ACCELERATORS↗

Notes on the design of experiments and beam diagnostics with synchrotron light detected by a gated photomultiplier for the Fermilab superconducting electron linac and for the Integrable Optics Test Accelerator (IOTA)

We outline the design of beam experiments for the electron linac at the Fermilab Accelerator Science and Technology (FAST) facility and for the Integrable Optics Test Accelerator (IOTA), based on synchrotron light emitted by the electrons in bend dipoles, detected with gated microchannel-plate photomultipliers (MCP-PMTs). The system can be used both for beam diagnostics (e.g., beam intensity with full dynamic range, turn-by-turn beam vibrations, etc.) and for scientific experiments, such as the direct observation of the time structure of the radiation emitted by single electrons in a storage ring. The similarity between photon pulses and spectrum at the downstream end of the electron linac and in the IOTA ring allows one to test the apparatus during commissioning of the linac.

43 PARTICLE ACCELERATORS↗

A Parasitic Electron Beam and Tagged Photon Beam

A parasitic electron beam facility has been developed at the Mark III linear accelerator, Stanford University. The beam has been used both for physics experiments and for counter and spark chamber tests, even though the beam intensity is very low. A tagged photon beam was installed as part of the facility. A description of the two beams and a short discussions of the applications of these beams is included.

43 PARTICLE ACCELERATORS↗

Proceedings of the Workshop on e + e - Physics at High Luminosities

This report contains an account of the work done in the workshop on e + e - Physics at High Luminosities. The Workshop was sponsored jointly by the SLAC-LBL Users Organization (SLUO) and the Stanford Linear Accelerator Center. Over 150 physicists participated in 2 sessions, one on 30 November - 1 December 1984 and one on 5-6 April 1985. The motivation for the workshop was provided by the realization that a simple inexpensive upgrade of PEP may lead to a luminosity of order 10 32 cm -2 sec -1 . The participants explored the physics opportunities that would become available for experiments logging 1 fb -1 . In addition the questions of optimal beam energy and detector upgrades were considered.

43 PARTICLE ACCELERATORS↗

Solid-State Ultra-High Power Amplifier Modules Based on 100 V RF GaN Technology for LINACS Operating at 325 and 650 MHz

Purpose / objectives. This research project explores the groundwork for developing a new high efficiency, high reliability and cost effective radio frequency technology to be used in power sources for future linear accelerators. The frequencies of operation are 650 and 325 MHz, in use at Fermi National Laboratory. The technology can be extended to other frequencies. Brief Description. In this research work ultra-high power solid-state radio frequency sources are proposed operating at the stated frequencies of interest. The approach employs high voltage Gallium Nitride radio frequency transistors, operating at 100 V or higher, to achieve 5-kilowatts continuous-wave and 10 kilowatts pulse power level in a small form factor. The 5 kilowatts building block reduces the required number of combiners and related losses to achieve megawatts power levels. The design employs harmonic tuning techniques as used in class E, F and inverse F power amplifiers to achieve >70% efficiency and assembly techniques that overcome heat dissipation in such high power density systems. Solid-state technology achieves million hour operating lifetime compared to 10 – 100 thousand hours for incumbent technology based on vacuum tubes. Additionally, the modular approach afforded by a solid-state solution avoids complete system shutdown when one module fails. Overall, the approach reduces capital and operating cost. Research Results. During Phase I radio frequency Gallium Nitride building block transistors with 50 mm gate periphery were designed and built which achieve ~600 W continuous-wave when operating at 100 V bias and 1-kW pulsed when operating at 150V. This level of performance has been demonstrated with operation at 325 and 650 MHz, and in both cases measured efficiency exceeded 70%. Potential Applications. The technology identified as suitable for high efficiency power sources in particle accelerators can also be applied in megawatt class radars and several industrial, scientific and medical applications such as microwave sintering, radio frequency and microwave ablation, oil percolation, MRI scanners and Nuclear Magnetic Resonance spectrometers, etc… The high efficiency of these devices also translates into reduced electrical power consumption and lower cost of operation.

100 VDC↗

Analysis of the Rhodotron Pulsed Beam Impact on the Northstar Mo100 Target Window

Northstar has elected to use rhodotrons rather than linear accelerators to deliver the electron beam to their targets. This decision has imposed a much lower frequency beam pulse on the target, resulting in short duration high power deposition. The impact on the target window is of particular importance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NSLS-II Linac Klystron Filament Failure Analysis

The NSLS-II linear accelerator uses the TH2100A klystron tube. One tube has failed with broken window with less than 8000 hours. The tuning (impedance matching) posts were clearly bent, indicating that this tube had a mismatch at the window that was tuned out at the factory. None of our other tubes arrived like this. It is not clear if this was a contributing factor to the failure. This tube was purchased by BNL and installed after linac commissioning to verify operation. Tube delivered with linac held as spare and re-installed when this tube failed.

42 ENGINEERING↗

Development of X-Ray FEL Oscillators with Higher Out-Coupling Efficiency

This program focused on the development of high-outcoupling efficiency resonators for x-ray free-electron laser oscillators (XFELOs). The goal was to produce a viable design for an XFELO that can be implemented on the LCLS-II which is the x-ray FEL facility under construction at the Stanford Linear Accelerator Center (SLAC). The program designed at regenerative amplifier (RAFEL) design that employs a high-gain undulator with a low-Q resonator with the goal of producing a scientific design for the RAFEL as well as a software suite that can be used to design XFELOs. The Phase I program considered a resonator consisting of six diamond Bragg reflectors/mirrors with two focusing lenses. This resonator was used in conjunction with the electron beam produced by the LCLS-II and the HXR undulator to design a RAFEL producing 3.05 keV photons in the fundamental resonance and 9.15 keV photons in the 3rd harmonic. The research program included the extension of the Optics Propagation Code (OPC) to describe Bragg reflection from diamond crystal mirrors and went on to use OPC, in conjunction with the MINERVA simulation code to treat the undulator interaction, to simulate the RAFEL. Simulations were conducted in both the steady-state and time-dependent regimes to determine the basic performance characteristics of the RAFEL.

43 PARTICLE ACCELERATORS↗

Part 1: Detailed Electromagnetic Design of an Integrated and Compact 1.3 GHZ Superconducting Radio Frequency (SRF) Electron

There exists a need for compact, reliable, high-power electron sources for applications including those in water treatment, basic science, defense, and security. There also exists a need for compact electron-beam based light and power sources of various power levels and at different frequencies (mm-wave to gamma rays) for applications also in the fields of basic science, industry, and defense and security. Today’s examples of high-average-power electron sources are neither very compact nor highly efficient. The same may be said for many of the electron-beam based light sources operated worldwide for myriad of applications. Recent breakthroughs in superconducting (SC) materials technology, radio-frequency (RF) power systems, specialized cathodes, and RF cavity designs offer ways to overcome the above-mentioned shortcomings. In this report, all these new features are integrated in a comprehensive design into one promising concept for a compact superconducting RF (SRF) high-average power electron linear accelerator. This design is capable of 5-50 kW average electron beam power and continuous wave operation with the corresponding electron beam energy up to 10 MeV.

43 PARTICLE ACCELERATORS↗

AASC Coated Cavities

The price of niobium is a significant part of the cost of superconducting RF cavity production. One route to significant cost reduction is to use cavities that have a thin layer of niobium deposited on a less expensive substrate. However, to date, all attempts to use thin films of niobium in superconducting RF cavities have resulted in cavity performance that does not meet the requirements for modern linear accelerators. Fermilab will provide two (2) cavities to AASC. AASC will coat the two (2) cavities with niobium using its high-purity deposition method. AASC will return the coated cavities to Fermilab for Quality Assurance (QA) testing. If the coatings pass preliminary QA tests performed at Fermilab, they will be subjected to RF testing at Fermilab and their performance will be evaluated relative to solid niobium cavities.

43 PARTICLE ACCELERATORS↗

Development of Tunable, Precision Permanent Magnet Phase Shifter for X-Ray FEL

In an X-ray free-electron laser (XFEL), a high quality relativistic electron beam from a linear accelerator traverses an array of undulator magnets to generate a high power X-ray beam by allowing the FEL to reach saturation. In many XFELs, phase shifters haven’t been commonly used or included in their designs. The importance of the phase shifter was recognized only recently. A phase shifter can be constructed using either an electromagnet (EM) or a permanent magnet (PM). EM phase shifters are heavy, complex to operate, and take more valuable longitudinal space between the undulators. Compared to EMs, the PMs have several outstanding advantages, including compactness, lighter weights, simple operation, and low maintenance. This project has developed an innovative design of fixed-gap, tunable PM-based compact phase shifter for the XFEL. While keeping the poles and gap fixed, the new design incorporates proven features from the prior work, along with novel field tuning methods, which allow the field strength to be adjusted within a reasonably large range to achieve the desired range of the phase delay control. The PM design without electric currents and power electronics associated with EMs improves reliability by reducing the number of possible points of failure and lowers the operation cost. The compactness makes it possible to use PM phase shifters in the existing XFELs with small gaps between adjacent undulators, as well as in the new XFELs without significantly increasing the FEL length. In Phase I we have accomplished the followings; 1) determined the optimum physics parameters for both weak and strong phase shifters; 2) conducted magnetic design with concrete magnetic and geometrical parameters of actual produced PM materials; 3) provided solutions to achieve precision fine tuning of the magnetic fields with unique methods; 4) elaborated a design based upon ease of manufacturing and cost analysis; and 5) produced rare-earth PM materials, which will be used for prototyping in Phase II. The phase I results provide a foundation for the research and development in the Phase II project, which will aim at building two full-size PM phase shifters and testing at SLAC National Accelerator Laboratory. This project will significantly provide the potential to bring a paradigm change in accelerator technology, replacing conventional electromagnets for many existing accelerator applications and allowing the development of new applications in completely new areas. For example, the PM FEL phase shifters can help significantly improve coherence and power of an XFEL. The proposed use of PM phase shifters will also bring significant cost savings to the construction, operation and maintenance of FEL facilities.

43 PARTICLE ACCELERATORS↗

DOE Data Day 2019 Report

The Department of Energy (DOE) has joined the larger scientific community in the promotion of data management as a means to higher quality, more efficient research and analysis, and as a critical component of data science. Tools and platforms to support data management and analysis are rapidly evolving and provide enormous opportunities. They also pose challenges that can be specific to DOE but are common across DOE mission areas and organizations. The DOE Data Day (D3) workshop was held on September 25–26, 2019, and organized by a team at Lawrence Livermore National Laboratory (LLNL) in an effort to gather the data management practitioners at the DOE labs together to share their work and results, facilitating knowledge transfers and best practices across project teams. Over 100 attendees participated from multiple national labs—LLNL, Sandia (SNL), Lawrence Berkeley (LBNL), Los Alamos (LANL), Oak Ridge (ORNL), Argonne (ANL), Pacific Northwest (PNNL), Stanford Linear Accelerator (SLAC)—along with Mission Support and Test Services (MSTS), National Energy Technology Laboratory (NETL), Pantex, National Security Complex (Y-12), National Nuclear Security Administration (NNSA), the DOE Office of Scientific and Technical Information (OSTI), and elsewhere in the DOE complex.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Advanced Control Methods for Particle Accelerators (ACM4PA) 2019

Los Alamos is currently developing novel particle accelerator controls and diagnostics algorithms to enable higher quality beams with lower beam losses than is currently possible. The purpose of this workshop was to consider tuning and optimization challenges of a wide range of particle accelerators including linear proton accelerators such as the Los Alamos Neutron Science Center (LANSCE), rings such as the Advanced Photon Source (APS) synchrotron, free electron lasers (FEL) such as the Linac Coherent Light Source (LCLS) and LCLS-II, the European X-ray Free Electron Laser (EuXFEL), the Swiss FEL, and the planned MaRIE FEL, and plasma wake- eld accelerators such as FACET, FACET-II, and AWAKE at CERN. One major challenge is an the ability to quickly create very high quality, extremely intense, custom current and energy pro le beams while working with limited real time non-invasive diagnostics and utilizing time-varying uncertain initial beam distributions and accelerator components. Currently, a few individual accelerator labs have been developing and applying their own diagnostics tools and custom control and ML algorithms for au- tomated machine tuning and optimization. The goal of this workshop was to bring together a group of accelerator physicists and accelerator related control and ML experts in order to de ne which controls and diagnostics would be most useful for existing and future accelerators and to create a plan for developing a new family of algorithms that can be shared and maintained by the community.

43 PARTICLE ACCELERATORS↗

Acceptance Calculation and Study of Fault Scenarios in the PIP-II Linac

The Proton Improvement Plan (PIP)-II is a proposed high intensity proton facility being developed at the Fermilab. The PIP-II is primarily based on construction of a new superconducting radio frequency (SRF) linear accelerator (linac) that would deliver an average beam current of 2mA with output energy up to 800 MeV. The acceptance of an accelerator outlines its sensitivity against deviations from its nominal design parameters. Consequently, a higher acceptance minimizes possibility of the beam loss. This paper presents longitudinal and transverse acceptance of the PIP-II SRF linac. Furthermore, paper also discusses implications of fault scenarios, such as the cavity failure, on the beam optics and acceptances.

43 PARTICLE ACCELERATORS↗

Beam Dynamics Study of PIP-II Superconducting Linac in the Presece of Misalignment Errors

The Proton Improvement Plan (PIP)-II is a proposed high intensity proton facility being developed at the Fermilab. The PIP-II is primarily based on construction of a new superconducting radio frequency (SRF) linear accelerator (linac) that would deliver an average beam current of 2mA with output energy up to 800 MeV. The linac performance is mainly determined by beam sensitivity against various component errors. These errors trigger not only emittance dilution but also a beam loss in worst cases. This paper discusses effects of component misalignments on the beam and presents alignment budget for the PIP-II SRF linac.

43 PARTICLE ACCELERATORS↗

The Future of LANSCE [Slides]

LANSCE is a NNSA Center for Materials and Nuclear Research. An aging stockpile presents unique challenges in materials and nuclear science. The grand challenge of a predictive materials capability includes design to manufacture and born certified. This requires capability to study manufacture to structure relationships and capability to study structure to performance relationships. LANSCE has the capabilities needed for this mission. We leverage our capability to provide broader benefit to the Nation including production of medical isotopes, industrial irradiation facility for electronics certification, and fundamental materials and physics research. The LANSCE linear accelerator is nearly 50 years old. The severity of maintenance issues is increasing. We must reinvest in LANSCE to ensure mission delivery into the future. We must develop new capability to be responsive to changing mission needs. Ultimately this will require a Dynamic Mesoscale Materials Science Capability. Now we must develop a pathway to MaRIE that ensures continued operation of LANSCE.

43 PARTICLE ACCELERATORS↗

Activation Study of Isotopically Enriched Samples During Neutron Time-of-Flight Measurements

Over the course of a time-of-flight neutron cross section measurement, the sample isotope(s) of interest are irradiated by neutrons and photons. Ideally, the enriched sample will not have any additional radioactivity after the measurement as compared to the baseline detectable radioactivity (0.6 Bq/g) established prior to acquisition of the sample. This document presents the process for estimating the activation of a stable enriched isotope exposed to a mixed photon and neutron source using tools from the SCALE code system developed at Oak Ridge National Laboratory. The report also presents the activation analysis for the isotopes of current interest: 90;91;92;94 Zr. This information is provided for two sets of Zr samples: one set of ZrO 2 samples, and one set of metal Zr samples. It was determined that, following measurements at the GELINA linear accelerator facility, all of the enriched Zr samples would contain less than 0.6 Bq/g of radioactivity within 183 days after irradiation.

07 ISOTOPE AND RADIATION SOURCES↗