Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LOOPS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Flight Testing of a Cryogenic Capillary Pumped Loop

This paper describes the flight test results of the fifth generation cryogenic capillary pumped loop (CCPL-5) which flew on the Space Shuttle STS-95 in October of 1998 as part of the CRYOTSU Flight Experiment. This flight was the first in-space demonstration of the CCPL, a lightweight heat transport and thermal switching device for future integrated cryogenic bus systems. The CCPL-5 utilized nitrogen as the working fluid and operated between 80K and 110K. Flight results indicated excellent performance of the CCPL-5 under zero-G environment. The CCPL could start from a supercritical condition in all tests, and the loop operating temperature could be tightly controlled regardless of changes in the heat load and/or the sink temperature. In addition, the loop demonstrated successful operation with a heat load of 0.5 W as well as with parasitic heat loads alone.

Ku, Jentung↗

Capillary Pumped Loop 3 Flight Experiment Overview

The Capillary Pumped Loop 3 (CAPL 3) Experiment is a follow on to the CAPL 1 and CAPL 2 experiments which flew on STS-60 (2/94) and STS-69 (9/95), respectively. CAPL 3 is tentatively scheduled to fly on the Space Shuttle in late 2000 as part of the Hitchhiker Experiments Advancing Technology (HEAT) payload. The experiment is a joint Naval Research Laboratory (NRL)/Goddard Space Flight Center (GSFC) payload which will meet technology objectives for both the Department of Defense and NASA. The primary objective of CAPL 3 is to demonstrate in space a multiple evaporator capillary pumped loop system, capable of reliable start-up, reliable continuous operation, and at least 50% heat load sharing with hardware for a deployable radiator. CAPL 3 is a full scale CPL system with four parallel capillary evaporators. The loop also contains a capillary starter pump, 8 parallel direct condensation condensers with associated flow regulators, a back pressure regulator, a two-phase reservoir, and various headers and transport tubing. A variable conductance heat pipe is located between one of the evaporators and the experiment radiator to provide a cooling source for the demonstration of heat load sharing. The experiment has an operating power range of 100 W to approximately 1400 W. The experiment ammonia charge will cause it to transition to a fixed conductance mode of operation if the radiator usage reaches 85%. Ambient functional tests have been performed on the experiment. Tests performed included start-up, low power, power cycles, high power, heat load sharing, variable/fixed conductance transition, saturation temperature changes, and pressure primes while the system was operating. The majority of the testing was performed at an ammonia saturation temperature of 30C, but a few tests were done at temperatures above and below this. The testing was highly successful. Details of the tests performed and a discussion of the results will be given in the presentation.

Ottenstein, Laura↗

Flight Testing of a Cryogenic Capillary Pumped Loop

Future space-based cryogenic systems will require enhanced integration flexibility, lower weight reduced parasitic penalties, better vibration isolation, and a variety of other improvements to meet performance goals. Additionally, there is an increasing need to locate cooling sources remotely from cooled components. In the past flexible conductive links were used and worked well in most cases. However, as the transport lengths increase, conductive couplings become heavier and less effective, and must be replaced by higher performance systems. One available option, which can meet many of these future requirements, is the cryogenic capillary pumped loop (CCPL). The development of the CCPL technology started in 1992, following the success of the room temperature CPLS. The extrapolation of CCPL technology to cryogenic temperatures offers many performance benefits, which are not currently within the reach of traditional heat pipes or conductive links. Specific advantages of the CCPL technology pertaining to cryocooler integration include: (1) greater capillary pumping pressure for improved ground testability; (2) improved mechanical isolation; (3) faster diode shutdown and lower reverse heat leaks; (4) tighter control of detector temperature; (5) variable or fixed conductance operation; and (6) ease of integration due to their flexibility. The applications of CCPL technology are numerous. Military and commercial applications include surveillance satellites, earth observing satellites, deep space observation systems, medical devices, and many other cryogenic systems. Over the past few years, several breadboard and prototype CCPLs have been built and ground tested. A prototype CCPL has demonstrated successful operation between 80K and 110K with heat loads between O.5W and 12W using nitrogen as the working fluid, and 35K and 40K with head loads of 0.25W to 3.5W using neon. In order to verify CCPL performance in a microgravity environment, a flight unit, CCPL-5, was tested onboard the Space Shuttle STS-95 in October of 1998 as part of the CRYOTSU Flight Experiment. This flight was the first in-space demonstration of the CCPL. The CCPL-5 utilized nitrogen as the working fluid and operated between 75K and 110K. Flight results indicated excellent performance of the CCPL-5 under zero-G environment The CCPL could start from a supercritical condition in all tests, and the loop operating temperature could be tightly controlled regardless of changes in the heat load and/or the sink temperature. In addition, the loop demonstrated successful operation with a heat load of 0.5W as well as with parasitic heat loads alone. There were no noticeable differences between zero-G and one-G operation.

Ku, Jentung↗

An Assessment of Magnetic Conditions for Strong Coronal Heating in Solar Active Regions by Comparing Observed Loops with Computed Potential Field Lines

We report further results on the magnetic origins of coronal heating found from combining coronal images with photospheric magnetograms. Here, for two complementary active regions, we compare the measured photospheric magnetic roots, extrapolated potential fields, and the distribution of bright coronal loops, to examine the global nonpotentiality of bright extended coronal loops and the three-dimensional structure of the magnetic field at their feet and to assess the role of these magnetic conditions in the strong coronal heating in these loops.

Falconer, D. A.↗

Thermal Control and Enhancement of Heat Transport Capacity of Two-Phase Loops With Electrohydrodynamic Conduction Pumping

There are three kinds of electrohydrodynamics (EHD) pumping based on Coulomb force: induction pumping, ion-drag pumping, and pure conduction pumping. EHD induction pumping relies on the generation of induced charges. This charge induction in the presence of an electric field takes place due to a non-uniformity in the electrical conductivity of the fluid which can be caused by a non-uniform temperature distribution and/or an inhomogeneity of the fluid (e.g. a two-phase fluid). Therefore, induction pumping cannot be utilized in an isothermal homogeneous liquid. In order to generate Coulomb force, a space charge must be generated. There are two main mechanisms for generating a space charge in an isothermal liquid. The first one is associated with the ion injection at a metal/liquid interface and the related pumping is referred to as ion-drag pumping. Ion-drag pumping is not desirable because it can deteriorate the electrical properties of the working fluid. The second space charge generation mechanism is associated with the heterocharge layers of finite thickness in the vicinity of the electrodes. Heterocharge layers result from dissociation of the neutral electrolytic species and recombination of the generated ions. This type of pumping is referred to as pure conduction pumping. This project investigates the EHD pumping through pure conduction phenomenon. Very limited work has been conducted in this field and the majority of the published papers in this area have mistakenly assumed that the electrostriction force was responsible for the net flow generated in an isothermal liquid. The main motivation behind this study is to investigate an EHD conduction pump for a two-phase loop to be operated in the microgravity environment. The pump is installed in the liquid return passage (isothermal liquid) from the condenser section to the evaporator section. Unique high voltage and ground electrodes have been designed that generate sufficient pressure heads with very low electric power requirements making the EHD conduction pumping attractive to applications such as two-phase systems (e.g. capillary pumped loops and heat pipes). Currently, the EHD conduction pump performance is being tested on a two-phase loop under various operating conditions in the laboratory environment. The simple non-mechanical and lightweight design of the EHD pump combined with the rapid control of performance by varying the applied electric field, low power consumption, and reliability offer significant advantages over other pumping mechanisms; particularly in reduced gravity applications.

Seyed-Yagoobi, J.↗

Closed-Loop Control System for Friction Stir Welding Retractable Pin Tool

NASA invention disclosure, NASA Case No. MFS-31413, entitled "System for Controlling the Stirring Pin of a Friction Stir Welding Apparatus", (Patent Pending) authored by Jeff Ding, Dr Peter Romine and Pete Oelgoetz, addresses the precision control of the friction stir welding process. The closed-loop control system automatically adjusts the spinning welding pin, real-time, to maintain a precise penetration ligament (i.e., distance between pin-tip and weld panel backside surface). A specific pin length can be maintained while welding constant thickness or tapered material thickness weld panels. The closed-loop control system provides operator data and information relative to the exact position of the welding pin inside the weld joint. This paper presents the closed-loop RPT control system that operates using the auto-feedback of force signals sensed by the tip and shoulder of the welding pin. Significance: The FSW process can be successfully used in a production environment only if there is a method or technique that informs the FSW operator the precise location of the welding pin inside the weld joint. This is essential for applications in aerospace, automotive, pressure vessel, commercial aircraft and other industries.

Ding, R. Jeffrey↗

Investigation of Capillary Limit in a Loop Heat Pipe

This paper presets an experimental study on the capillary limit of a loop heat pipe (LHP) at low powers. The slow thermal response of the loop at low powers made it possible to observe interactions among various components after the capillary limit was exceeded. The capillary limit at low powers was achieved by imposing additional pressure drops on the vapor line through the use of a metering valve. A differential pressure transducer was also used to measure the pressure drop across the evaporator and the compensation chamber (CC). Test results show that when the capillary limit is exceeded, vapor will penetrate the primary wick, resulting in a partial dry-out of the evaporator and a rapid increase of the CC temperature. Because the evaporator can tolerate vapor bubbles, the LHP will continue to function and may reach a new steady state at the higher temperature. Thus, the LHP will exhibit a graceful degradation in performance rather than a complete failure. Moreover, the loop can recover from a partial dry-out by reducing the heat load without a re-start.

Ku, Jentung↗

Flight Testing of the Capillary Pumped Loop 3 Experiment

The Capillary Pumped Loop 3 (CAPL 3) experiment was a multiple evaporator capillary pumped loop experiment that flew in the Space Shuttle payload bay in December 2001 (STS-108). The main objective of CAPL 3 was to demonstrate in micro-gravity a multiple evaporator capillary pumped loop system, capable of reliable start-up, reliable continuous operation, and heat load sharing, with hardware for a deployable radiator. Tests performed on orbit included start-ups, power cycles, low power tests (100 W total), high power tests (up to 1447 W total), heat load sharing, variable/fixed conductance transition tests, and saturation temperature change tests. The majority of the tests were completed successfully, although the experiment did exhibit an unexpected sensitivity to shuttle maneuvers. This paper describes the experiment, the tests performed during the mission, and the test results.

Ottenstein, Laura↗

Strategies for Small Volume Resuscitation: Hyperosmotic-Hyperoncotic Solutions, Hemoglobin Based Oxygen Carriers and Closed-Loop Resuscitation

Introduction: Logistic constraints on combat casualty care preclude traditional resuscitation strategies which can require volumes and weights 3 fold or greater than hemorrhaged volume. We present a review of quantitative analyses of clinical and animal data on small volume strategies using 1) hypertonic-hyperosmotic solutions (HHS); 2) hemoglobin based oxygen carriers (HBOCs) and 3) closed-loop infusion regimens.Methods and Results: Literature searches and recent queries to industry and academic researchers have allowed us to evaluate the record of 81 human HHS studies (12 trauma trials), 19 human HBOCs studies (3trauma trials) and two clinical studies of closed-loop resuscitation.There are several hundreds animal studies and at least 82 clinical trials and reports evaluating small volume7.2%-7.5% hypertonic saline (HS) most often combined with colloids, e.g., dextran (HSD) or hetastarch(HSS). HSD and HSS data has been published for 1,108 and 392 patients, respectively. Human studies have documented volume sparing and hemodynamic improvements. Meta-analyses suggest improved survival for hypotensive trauma patients treated with HSD with significant reductions in mortality found for patients with blood pressure < 70 mmHg, head trauma, and penetrating injury requiring surgery. HSD and HSS have received regulatory approval in 14 and 3 countries, respectively, with 81,000+ units sold. The primary reported use was head injury and trauma resuscitation. Complications and reported adverse events are surprisingly rare and not significantly different from other solutions.HBOCs are potent volume expanders in addition to oxygen carriers with volume expansion greater than standard colloids. Several investigators have evaluated small volume hyperoncotic HBOCs or HS-HBOC formulations for hypotensive and normotensive resuscitation in animals. A consistent finding in resuscitation with HBOCs is depressed cardiac output. There is some evidence that HBOCs more efficiently unload oxygen from plasma hemoglobin as well as facilitate RBC unloading. We analyzed one volunteer study, 15 intraoperative trials, and 3 trauma studies using HBOCs. Perioperative studies generally suggest ability to deliver oxygen, but one trauma trial using HBOCs (HemAssist) for treatment of trauma resulted in a dramatic increase in mortality, while an intraoperative trauma study using Polyheme demonstrated reductions in blood use and lower mortality compared to historic controls of patients refusing blood. Transfusion reductions with HBOC use have been modest. Two HBOCs (Hemopure and Polyheme) are now in new or planned large-scale multicenter prehospital trials of trauma treatment. A new implementation of small volume resuscitation is closed-loop resuscitation (CLR), which employs microprocessors to titrate just enough fluid to reach a physiologic target . Animal studies suggest less risk of rebleeding in uncontrolled hemorrhage and a reduction in fluid needs with CLR. The first clinical application of CLR was treatment of burn shock and the US Army. Conclusions: Independently sponsored civilian trauma trials and clinical evaluations in operational combat conditions of different small volume strategies are warranted.

Kramer, George C.↗

Closed-Loop Evaluation of an Integrated Failure Identification and Fault Tolerant Control System for a Transport Aircraft

Formal robustness analysis of aircraft control upset prevention and recovery systems could play an important role in their validation and ultimate certification. Such systems developed for failure detection, identification, and reconfiguration, as well as upset recovery, need to be evaluated over broad regions of the flight envelope or under extreme flight conditions, and should include various sources of uncertainty. To apply formal robustness analysis, formulation of linear fractional transformation (LFT) models of complex parameter-dependent systems is required, which represent system uncertainty due to parameter uncertainty and actuator faults. This paper describes a detailed LFT model formulation procedure from the nonlinear model of a transport aircraft by using a preliminary LFT modeling software tool developed at the NASA Langley Research Center, which utilizes a matrix-based computational approach. The closed-loop system is evaluated over the entire flight envelope based on the generated LFT model which can cover nonlinear dynamics. The robustness analysis results of the closed-loop fault tolerant control system of a transport aircraft are presented. A reliable flight envelope (safe flight regime) is also calculated from the robust performance analysis results, over which the closed-loop system can achieve the desired performance of command tracking and failure detection.

Shin, Jong-Yeob↗

Motion of 3-6 keV Nonthermal Sources Along the Legs of a Flare Loop

Observations of nonthermal X-ray sources me critical to studying electron acceleration and transport in solar flares. Strong thermal emission radiated from the preheated plasma before the flare impulsive phase often makes it difficult to detect low-energy X-ray sources that are produced by relatively low-energy nonthermal electrons. Knowledge of the distribution of these low-energy nonthermal electrons is particularly important in determining the total nonthermal electron energy in solar flares. We report on an 'early impulsive flare' in which impulsive hard X-ray emission was seen early in the flare before the soft X-ray emission had risen significantly, indicating limited plasma pre-heating. Early in the flare, RHESSI < 25 keV images show coronal sources that moved first downward and then upwards along the legs of a flare loop. In particular, the 3-6 keV source appeared as a single coronal source at the start of the flare, and then it involved into two coronal sources moving down along the two legs of the loop. After nearly reaching the two footpoints at the hard X-ray peak, the two sources moved back up to the looptop again. RHESSI images and light curves all indicate that nonthermal emission dominated at energies as low as 3-6 keV. We suggest that the evolution of both the spectral index and the low-energy cutoff of the injected electron distribution could result in the accelerated electrons reaching a lower altitude along the legs of the dense flare loop and hence result in the observed downward and upward motions of the nonthermal sources.

Sui, Linhui↗

Effects of Gravity on Start-up of a Miniature Loop Heat Pipe with Multiple Evaporators and Multiple Condensers

This paper describes an experimental study on the effect of gravity on the start-up of a miniature loop heat pipe (MLHP) with two evaporators and two condensers. Each evaporator has an outer diameter of 9 mm and has its own integral compensation chamber (CC). The MLHP was placed under five configurations where the relative elevation and tilt among the loop components were varied. The four well-known initial conditions between the evaporator and CC prior to the LHP start-up were created in this experimental study through combinations of: 1) the test configuration; 2) the method of preconditioning the loop prior to start-up, and 3) the heat load distribution among the evaporators. A total of 165 start-ups were conducted under the five test configurations. All of these start-ups were successful. However, the effect of gravity on start-up transients was clearly seen under otherwise the same heat load distribution and sink temperatures. An analytical model was used to simulate the MLHP transient behaviors, and the model predictions agreed very well with the experimental results.

Ku, Jentung↗

Phase-locked loop FM demodulator

A conventional phase-locked loop is improved by replacing its phase detector with one comprising a linear ramp generator and a sample-and-hold circuit, thus eliminating the need for a lowpass loop filter, although the output of the sample-and-hold circuit may be filtered in the case of a very low level modulating signal on the incoming FM signal, but then filtering is not a difficult problem as in a conventional phase-locked loop. The result is FM demodulation by zero-order estimation. For FM demodulation by first-order estimation, the arithmetic difference between adjacent samples is formed, and using a second sample-and-hold circuit an arithmetic difference signal is produced as an input to a second ramp generator that is reset after each sampling cycle to generate a ramp the slope of which is a function of the arithmetic difference signal stored in the second sample-and-hold circuit. The ramp thus generated by the second ramp generator is arithmetically summed with the zero-estimation signal from the first sample-and-hold circuit to form a first-order estimation signal. Filtering such a first-order estimation signal is less of a problem than filtering a zero-order estimation signal.

Kirkham, Harold↗

Digital phase-lock loop

An improved digital phase lock loop incorporates several distinctive features that attain better performance at high loop gain and better phase accuracy. These features include: phase feedback to a number-controlled oscillator in addition to phase rate; analytical tracking of phase (both integer and fractional cycles); an amplitude-insensitive phase extractor; a more accurate method for extracting measured phase; a method for changing loop gain during a track without loss of lock; and a method for avoiding loss of sampled data during computation delay, while maintaining excellent tracking performance. The advantages of using phase and phase-rate feedback are demonstrated by comparing performance with that of rate-only feedback. Extraction of phase by the method of modeling provides accurate phase measurements even when the number-controlled oscillator phase is discontinuously updated.

Thomas, Jr., Jess B.↗

Pump, and earth-testable spacecraft capillary heat transport loop using augmentation pump and check valves

A spacecraft includes heat-generating payload equipment, and a heat transport system with a cold plate thermally coupled to the equipment and a capillary-wick evaporator, for evaporating coolant liquid to cool the equipment. The coolant vapor is coupled to a condenser and in a loop back to the evaporator. A heated coolant reservoir is coupled to the loop for pressure control. If the wick is not wetted, heat transfer will not begin or continue. A pair of check valves are coupled in the loop, and the heater is cycled for augmentation pumping of coolant to and from the reservoir. This augmentation pumping, in conjunction with the check valves, wets the wick. The wick liquid storage capacity allows the augmentation pump to provide continuous pulsed liquid flow to assure continuous vapor transport and a continuously operating heat transport system. The check valves are of the ball type to assure maximum reliability. However, any type of check valve can be used, including designs which are preloaded in the closed position. The check valve may use any ball or poppet material which resists corrosion. For optimum performance during testing on Earth, the ball or poppet would have neutral buoyancy or be configured in a closed position when the heat transport system is not operating. The ball may be porous to allow passage of coolant vapor.

Baker, David↗

Flow Components in a NaK Test Loop Designed to Simulate Conditions in a Nuclear Surface Power Reactor

A test loop using NaK as the working fluid is presently in use to study material compatibility effects on various components that comprise a possible nuclear reactor design for use on the lunar surface. A DC electromagnetic (EM) pump has been designed and implemented as a means of actively controlling the NaK flow rate through the system and an EM flow sensor is employed to monitor the developed flow rate. These components allow for the matching of the flow rate conditions in test loops with those that would be found in a full-scale surface-power reactor. The design and operating characteristics of the EM pump and flow sensor are presented. In the EM pump, current is applied to a set of electrodes to produce a Lorentz body force in the fluid. A measurement of the induced voltage (back-EMF) in the flow sensor provides the means of monitoring flow rate. Both components are compact, employing high magnetic field strength neodymium magnets thermally coupled to a water-cooled housing. A vacuum gap limits the heat transferred from the high temperature NaK tube to the magnets and a magnetically-permeable material completes the magnetic circuit. The pump is designed to produce a pressure rise of 5 psi, and the flow sensor's predicted output is roughly 20 mV at the loop's nominal flow rate of 0.5 GPM.

Polzin, Kurt A.↗

Capillary Limit of a Miniature Loop Heat Pipe with Multiple Evaporators and Multiple Condensers

An experimental investigation of a miniature loop heat pipe with multiple evaporators and multiple condensers were conducted in order to evaluate its capillary limit. The experimental tests were conducted by varying heat load to one or both evaporators, with and without active temperature control of compensation chamber (CC) using the thermoelectric devices, and variable tilts between the evaporators and the CCs. The physical process of the loop and thermal conductance of the heat leak from evaporator to (CC) were discussed based on the test results. The difference of the temperature profiles between with and without active control of CC temperature was evaluated. The effect of the gravity on capillary limit and CC temperature was also evaluated by comparing the test result in horizontal position with that in vertical position. The loop recovery after capillary limit was exceeded was also described.

Ku, Jentung↗