Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

An instrument combining an electrospray ionization source and a velocity-map imaging spectrometer for studying delayed electron emission of polyanions

An instrument combining an electrospray ionization source and a velocity-map imaging (VMI) spectrometer has been developed in order to study the delayed electron emission of molecular anions and especially of polyanions. It operates at a high repetition rate (kHz) in order to increase the acquisition speed. The VMI spectrometer has been upgraded for nanosecond time resolution by gating the voltages applied on the position-sensitive detector. Kinetic energy release distribution of thermionic emission (without any contribution from direct detachment) can be recorded for well-defined delays after the nanosecond laser excitation. The capability of the instrument is demonstrated by recording photodetachment spectra of the benchmark C{sub 60}{sup −} anion and C{sub 84}{sup 2−} dianion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstration of a time-resolved x-ray scattering instrument utilizing the full-repetition rate of x-ray pulses at the Pohang Light Source

We report on the development of a new experimental instrument for time-resolved x-ray scattering (TRXS) at the Pohang Light Source (PLS-II). It operates with a photon energy ranging from 5 to 18 keV. It is equipped with an amplified Ti:sappahire femtosecond laser, optical diagnostics, and laser beam delivery for pump-probe experiments. A high-speed single-element detector and high trigger-rate oscilloscope are used for rapid data acquisition. While this instrument is capable of measuring sub-nanosecond dynamics using standard laser pump/x-ray probe techniques, it also takes advantage of the dense 500 MHz standard fill pattern in the PLS-II storage ring to efficiently record nano-to-micro-second dynamics simultaneously. We demonstrate this capability by measuring both the (fast) impulsive strain and (slower) thermal recovery dynamics of a crystalline InSb sample following intense ultrafast laser excitation. Exploiting the full repetition rate of the storage ring results in a significant improvement in data collection rates compared to conventional bunch-tagging methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An instrument for in situ coherent x-ray studies of metal-organic vapor phase epitaxy of III-nitrides

Here, we describe an instrument that exploits the ongoing revolution in synchrotron sources, optics, and detectors to enable in situ studies of metal-organic vapor phase epitaxy (MOVPE) growth of III-nitride materials using coherent x-ray methods. The system includes high-resolution positioning of the sample and detector including full rotations, an x-ray transparent chamber wall for incident and diffracted beam access over a wide angular range, and minimal thermal sample motion, giving the sub-micron positional stability and reproducibility needed for coherent x-ray studies. The instrument enables surface x-ray photon correlation spectroscopy, microbeam diffraction, and coherent diffraction imaging of atomic-scale surface and film structure and dynamics during growth, to provide fundamental understanding of MOVPE processes.

36 MATERIALS SCIENCE↗

A suite-level review of the neutron powder diffraction instruments at Oak Ridge National Laboratory

The suite of neutron powder diffractometers at Oak Ridge National Laboratory (ORNL) utilizes the distinct characteristics of the Spallation Neutron Source and High Flux Isotope Reactor to enable the measurements of powder samples over an unparalleled regime at a single laboratory. Full refinements over large Q ranges, total scattering methods, fast measurements under changing conditions, and a wide array of sample environments are available. Here, this article provides a brief overview of each powder instrument at ORNL and details the complementarity across the suite. Future directions for the powder suite, including upgrades and new instruments, are also discussed.

47 OTHER INSTRUMENTATION↗

Instrumentation for the upgrade to the JET core charge-exchange spectrometers

Charge-exchange spectroscopy on JET has become particularly challenging with the introduction of the ITER-like wall. The line intensities are weaker and contaminated by many nuisance lines. We have therefore upgraded the instrumentation to improve throughput and allow the simultaneous measurement of impurity and fuel-ion charge exchange by splitting the light between two pairs of imaging spectrometers using dichroic beam splitters. Imaging instruments allow us to stack 11 × 1 mm diameter fibres on the entrance slits without cross talk. CCD cameras were chosen to have 512 × 512 pixels to allow frame transfer times <0.2 ms which with minimum exposure times of 5 ms give tolerable smearing even without a chopper. The image plane is optically demagnified 2:1 to match the sensor size of these cameras. Because the image plane of the spectrometer is tilted, the CCD must also be tilted to maintain focus over the spectrum (Scheimpflug condition). To avoid transverse keystoning (causing the vertical height of the spectra to change across the sensor), the configuration is furthermore designed to be telecentric by a suitable choice of the lens separation. The lens configuration is built almost entirely from commercial off-the-shelf components, which allowed it to be assembled and aligned relatively rapidly to meet the deadline for in-vessel calibration in the JET shutdown.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Warm Electron Beam Ion Trap (WEBIT): An instrument for ground calibration of space-borne x-ray spectrometers

The warm electron beam ion trap (WEBIT) at Lawrence Livermore National Laboratory is being developed as a pre-launch, ground calibration source for space-borne, high-throughput, high-resolution x-ray spectrometers, such as the x-ray imaging and spectroscopy mission Resolve quantum calorimeter. Historically, calibration sources for calorimeter spectrometers have relied on characteristic line emission from x-ray tubes, fluorescing metals, and radioactive sources. The WEBIT, by contrast, relies on emission from x-ray transitions in highly charged ions, for example, hydrogen-like and helium-like ions, whose energies are well known and whose line shapes are relatively simple. The WEBIT can create astrophysically relevant ions whose x-ray emission falls in the 0.3-12 keV science bandpass of Resolve and has a portable design advantageous for a calibration source. The WEBIT will be used to help calibrate Resolve’s instrumental line shape and gain scale as a function of various operational parameters during both detector subsystem level testing and instrumental level testing.

47 OTHER INSTRUMENTATION↗

Nanopositioning Flexure Stages Development for Synchrotron Radiation Instrumentation at the Advanced Photon Source

Nanopositioning techniques present an important capability to support the state-of-the-art synchrotron radiation instrumentation research for the Advanced Photon Source (APS) operations and upgrade project. To overcome the performance limitations of precision ball-bearing-based or roller-bearing-based stage systems, compact nanopositioning flexure stages have been designed and developed at the APS for x-ray beamline instrumentation applications. Recent progress of such stages development is discussed in this paper, which includes: rotary flexure stages with degrees travel range and 10-nrad-level resolution for x-ray monochromators and analysers, tip-tilting flexure stages for K-B mirror based nanofocusing hard x-ray optics, and linear vertical and horizontal nanopositioning flexure stages with centimeter-level travel range and microradian-level motion trajectory reproducibility for x-ray optics and sample manipulation. The mechanical design and preliminary test results are described in this paper.

Nanopositioning, X-ray optics, synchrotron radiati↗

VIPIR: A High-Throughput Drop-Weight Impact Instrument for Imaging the Initiation and Propagation of Reactions in Energetic Materials

Characterizing the handling safety and sensitivity of explosives has been a challenging area of study for over 60 years. Historically one of the most accessible and widely utilized experiments has been the drop-weight impact test, which involves dropping a weight on a small sample sandwiched between two anvils. Because this experiment generally only utilizes sound thresholds to determine whether or not a sample reacted, the physical and chemical properties governing sensitivity remain convolved. Better understanding of chemical and material characteristics is needed to give the chemistry and engineering communities a predictive tool to determine the handling sensitivity of explosives prior to pursuing expensive and potentially hazardous synthesis and formulation operations. Here, we are developing a high throughput drop tower instrument capable of imaging the deformation and flow of energetic materials during impact and the resulting thermal ignition and propagation events. This instrument is based on previous designs but has been modified for higher throughput and tailorable modifications in the future. Herein, we present key design features that enable high-speed visible and thermal imaging of explosive initiation by sub-shock impacts, as well as preliminary results in which ignition sites were observed in an erythritol tetranitrate sample.

47 OTHER INSTRUMENTATION↗

High-resolution inelastic x-ray scattering at the high energy density scientific instrument at the European X-Ray Free-Electron Laser

We introduce a setup to measure high-resolution inelastic x-ray scattering at the High Energy Density scientific instrument at the European X-Ray Free-Electron Laser (XFEL). The setup uses the Si (533) reflection in a channel-cut monochromator and three spherical diced analyzer crystals in near-backscattering geometry to reach a high spectral resolution. An energy resolution of 44 meV is demonstrated for the experimental setup, close to the theoretically achievable minimum resolution. The analyzer crystals and detector are mounted on a curved-rail system, allowing quick and reliable changes in scattering angle without breaking vacuum. The entire setup is designed for operation at 10 Hz, the same repetition rate as the high-power lasers available at the instrument and the fundamental repetition rate of the European XFEL. Among other measurements, it is envisioned that this setup will allow studies of the dynamics of highly transient laser generated states of matter.

47 OTHER INSTRUMENTATION↗

Instrument for spatially resolved, temperature-dependent electrochemical impedance spectroscopy of thin films under locally controlled atmosphere

We demonstrate an instrument for spatially resolved measurements (mapping) of electrochemical impedance under various temperatures and gas environments. Automated measurements are controlled by a custom LabVIEW program, which manages probe motion, sample motion, temperature ramps, and potentiostat functions. Sample and probe positioning is provided by stepper motors. Dry or hydrated atmospheres (air or nitrogen) are available. The configurable heater reaches temperatures up to 500 °C, although the temperature at the sample surface is moderated by the gas flow rate. The local gas environment is controlled by directing flow toward the sample via a glass enclosure that surrounds the gold wire probe. Software and hardware selection and design are discussed. Reproducibility and accuracy are quantified on a Ba(Zr,Y)O 3-δ proton-conducting electrolyte thin film synthesized by pulsed laser deposition. The mapping feature of the instrument is demonstrated on a compositionally graded array of electrocatalytically active Ba(Co,Fe,Zr,Y)O 3-δ thin film microelectrodes. The resulting data indicate that this method proficiently maps property trends in these materials, thus demonstrating the reliability and usefulness of this method for investigating electrochemically active thin films.

47 OTHER INSTRUMENTATION↗

Instrumentation development and testing of a wind turbine blade for sub-scale wake studies

Wind turbine blade aerodynamics and the resulting wake flow are complex, and wind tunnel testing of these flows can provide critical insight. The data from such tests are also valuable for validation of numerical models. For experiments using sub-scale turbines to be useful, the blade aerodynamics and wakes must exhibit the important features observed in utility-scale turbine flows. In this work, ~1 m blades designed to produce physics relevant to larger scale turbines were manufactured and affixed to an existing turbine. One of the blades was instrumented for blade surface pressure measurements. Time-dependent surface pressure measurements coupled with instantaneous measurements of the inflow with Cobra probes and the wake with particle image velocimetry allowed for characterization of the inflow, blade flow, and near wake. The results demonstrate that the instrumentation was effective in characterizing the blade loading and the flow field. For the one test case discussed in this paper, the measurements of inflow, blade loading, and wake properties facilitate understanding of the wake's behavior.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A multi-scale cognitive interaction model of instrument operations at the Linac Coherent Light Source

The Linac Coherent Light Source (LCLS) is the world’s first x-ray free electron laser. It is a scientific user facility operated by the SLAC National Accelerator Laboratory, at Stanford, for the U.S. Department of Energy. As beam time at LCLS is extremely valuable and limited, experimental efficiency—getting the most high quality data in the least time—is critical. Our overall project employs cognitive engineering methodologies with the goal of improving experimental efficiency and increasing scientific productivity at LCLS by refining experimental interfaces and workflows, simplifying tasks, reducing errors, and improving operator safety and stress. Here, in this study, we describe a multi-agent, multi-scale computational cognitive interaction model of instrument operations at LCLS. Our model simulates the aspects of human cognition at multiple cognitive and temporal scales, ranging from seconds to hours, and among agents playing multiple roles, including instrument operator, real time data analyst, and experiment manager. The model can roughly predict impacts stemming from proposed changes to operational interfaces and workflows. Example results demonstrate the model’s potential in guiding modifications to improve operational efficiency. We discuss the implications of our effort for cognitive engineering in complex experimental settings and outline future directions for research. The model is open source, and the videos of the supplementary material provide extensive detail.

47 OTHER INSTRUMENTATION↗

Instrumental Backgrounds to $t\bar{t}$ and Single Top Production at Hadron Colliders

A number of backgrounds to top-quark production at the LHC and Tevatron experiments are characterized as instrumental: beam related-backgrounds, cosmic ray backgrounds, and backgrounds from non-prompt (or fake) leptons. A number of strategies have been deployed in the experiments to minimize these backgrounds and to estimate their rates. The strategies are applied at the level of the accelerator, the detector apparatus, the first few cuts which are common to many physics analyses, and more refined kinematic cuts. Remaining fake lepton background is estimated using sophisticated data-driven techniques. We present here a survey of the state-of-the-art in the reduction of instrumental backgrounds and also their estimation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and performance characterisation of the HAPG von Hámos Spectrometer at the High Energy Density Instrument of the European XFEL

The von Hámos spectrometer setup at the HED instrument of the European XFEL is described in detail. The spectrometer is designed to be operated primarily between 5 and 15 keV to complement the operating photon energy range of the HED instrument. Four Highly Annealed Pyrolitic Graphite (HAPG) crystals are characterised with thicknesses of 40 μm or 100 μm and radius-of-curvature 50 mm or 80 mm, in conjunction with either an ePix100 or Jungfrau detector. The achieved resolution with the 50 mm crystals, operated between 6.5 and 9 keV, matches that reported previously: ~8 eV for a thickness of 40 μm, whereas, with an 80 mm crystal of thickness 40 μm, the resolution exceeds that expected. Namely, a resolution of 2 eV is demonstrated between 5–6 keV implying a resolving power of 2800. Therefore, we posit that flatter HAPG crystals, with their high reflectivity and improved resolving power, are a powerful tool for hard x-ray scattering and emission experiments allowing unprecedented measurements of collective scattering in a single shot.

47 OTHER INSTRUMENTATION↗

The X-ray correlation spectroscopy instrument at the Linac Coherent Light Source

The X-ray Correlation Spectroscopy instrument is dedicated to the study of dynamics in condensed matter systems using the unique coherence properties of free-electron lasers. It covers a photon energy range of 4–25 keV. The intrinsic temporal characteristics of the Linac Coherent Light Source, in particular the 120 Hz repetition rate, allow for the investigation of slow dynamics (milliseconds) by means of X-ray photon correlation spectroscopy. Double-pulse schemes could probe dynamics on the picosecond timescale. In addition, a description of the instrument capabilities and recent achievements is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low-kilovolt coherent electron diffractive imaging instrument based on a single-atom electron source

In this work, a transmission-type, low-kilovolt coherent electron diffractive imaging instrument was constructed. It comprised a single-atom field emitter, a triple-element electrostatic lens, a sample holder, and a retractable delay line detector to record the diffraction patterns at different positions behind the sample. It was designed to image materials thinner than 3 nm. The authors analyzed the asymmetric triple-element electrostatic lens for focusing the electron beams and achieved a focused beam spot of 87 nm on the sample plane at the electron energy of 2 kV. High-angle coherent diffraction patterns of a suspended graphene sample corresponding to (0.62 Å){sup −1} were recorded. This work demonstrated the potential of coherent diffractive imaging of thin two-dimensional materials, biological molecules, and nano-objects at a voltage between 1 and 10 kV. The ultimate goal of this instrument is to achieve atomic resolution of these materials with high contrast and little radiation damage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integration of a 6 LilnSe 2 thermal neutron detector into a CubeSat instrument

This paper describes the development of a preliminary compact and lightweight neutron detection system that uses the low power consuming CubeSat platform and will be especially effective for space-based applications. This is made possible using the novel 6 LiInSe 2 scintillator crystal and a silicon avalanche photodiode (Si-APD). The schematics of this instrument are presented as well as the response of the instrument to initial testing under alpha radiation. The entire system weighs 670 grams and requires 5 volts direct current at 3 watts.

36 MATERIALS SCIENCE↗

Overview of the Dark Energy Spectroscopic Instrument

The Dark Energy Spectroscopic Instrument (DESI) is under construction to measure the expansion history of the Universe using the Baryon Acoustic Oscillation technique. The spectra of 35 million galaxies and quasars over 14000 square degrees will be measured during the life of the experiment. A new prime focus corrector for the KPNO Mayall telescope will deliver light to 5000 fiber optic positioners. The fibers in turn feed ten broad-band spectrographs. We present an overview of the instrumentation, the main technical requirements and challenges, and the current status of the project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗