Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IONIZATION CHAMBER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Measurement Of The Neutron Spectrum Of A DD Electronic Neutron Generator

A Cuttler-Shalev (C-S){sup 3}He proportional counter has been used to measure the energy spectrum of neutrons from a portable deuterium-deuterium electronic neutron generator. To improve the analysis of results from the C-S detector digital pulse shape analysis techniques have been used to eliminate neutron recoil artifacts in the recorded data. Data was collected using a 8-GHz, 10-bit waveform digitizer with its full scale corresponding to approximately 6-MeV neutrons. The measurements were made with the detector axis perpendicular to the direction of ions in the ENG in a plane 0.5-m to the side of the ENG, measuring neutrons emitted at an angle from 87.3 deg. to 92.7 deg. with respect to the path of ions in the ENG. The system demonstrated an energy resolution of approximately 0.040 MeV for the thermal peak and approximately 0.13 MeV at the DD neutron energy. In order to achieve the ultimate resolution capable with this type of detector it is clear that a higher-precision digitizer will be needed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Commissioning of Angle Dispersive X-ray Diffraction Beamline on Indus-2

An Angle dispersive x-ray diffraction (ADXRD) beamline on bending magnet source of Indus-2 synchrotron (2.5 GeV, 300 mA) has been commissioned, for the study of single and polycrystalline samples. The beamline optics is based on vertically focusing Pt-coated pre and post mirrors and sagittal focusing Si (311) based double crystal monochromator. Experimental station consists of a six circle diffractometer equipped with scintillation detector and an image plate area detector for powder diffraction. XRD experiments have been performed to study single crystal and polycrystalline samples.

43 PARTICLE ACCELERATORS↗

A detection system for very low-energy protons from {beta}-delayed proton decay

We have recently developed a gas based detection system called AstroBox, motivated by nuclear astrophysics studies. The goal was to detect very low-energy protons from {beta}-delayed p-decay with reduced beta background and improved energy resolution. The detector was tested using the {beta}-delayed proton-emitter 23Al previously studied with a set-up based on thin double-sided Si strip detectors. The proton spectrum obtained with AstroBox showed no beta background down to {approx}80 keV. The low energy (206 keV, 267 keV) proton peaks were positively identified, well separated, and the resolution was improved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large area liquid argon detectors for interrogation systems

Measurements of the efficiency, pulse shape, and energy and time resolution of liquid argon (LAr) detectors are presented. Liquefied noble gas-based (LNbG) detectors have been developed for the detection of dark matter and neutrinoless double-beta decay. However, the same qualities that make LNbG detectors ideal for these applications, namely their size, cost, efficiency, pulse shape discrimination and resolution, make them promising for portal screening and the detection of Special Nuclear Materials (SNM). Two 18-liter prototype detectors were designed, fabricated, and tested, one with pure LAr and the other doped with liquid Xe (LArXe). The LArXe detector presented the better time and energy resolution of 3.3 ns and 20% at 662 KeV, respectively. The total efficiency of the detector was measured to be 35% with 4.5% of the total photons detected in the photopeak.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New developments in micro-X-ray diffraction and X-ray absorption spectroscopy for high-pressure research at 16-BM-D at the Advanced Photon Source

We report the monochromator and focusing mirrors of the 16-BM-D beamline, which is dedicated to high-pressure research with micro-X-ray diffraction (micro-XRD) and X-ray absorption near edge structure (XANES) (6-45 keV) spectroscopy, have been recently upgraded. Monochromatic X-rays are selected by a Si (111) double-crystal monochromator operated in an artificial channel-cut mode and focused to 5 μm × 5 μm (FWHM) by table-top Kirkpatrick-Baez type mirrors located near the sample stage. The typical X-ray flux is ~5 × 10 8 photons/s at 30 keV. The instrumental resolution, Δq/q max , reaches to 2 × 10 –3 and is tunable through adjustments of the detector distance and X-ray energy. The setup is stable and reproducible, which allows versatile application to various types of experiments including resistive heating and cryogenic cooling as well as ambient temperature compression. Transmission XANES is readily combined with micro-XRD utilizing the fixed-exit feature of the monochromator, which allows combined XRD-XANES measurements at a given sample condition.

47 OTHER INSTRUMENTATION↗

Charge carrier mobility of halide perovskite single crystals for ionizing radiation detection

Halide perovskites have recently emerged as promising semiconductor materials for several applications including solar cells, light-emitting diodes (LEDs), and radiation detectors. The charge carrier transport properties, which could be evaluated by the mobility-lifetime (mu-tau or μ-г) product, serve an important role for the development of halide perovskites for radiation detection applications. In this perspective, we firstly explain the charge transport mechanism and the limiting factors that determine the intrinsic charge carrier mobility in halide perovskite single crystals. Then, we overview the techniques and methods that have been employed for evaluating the charge carrier mobility (for both electrons and holes). Lastly, we discuss the discrepancy between the experimentally determined carrier mobility from the literature for halide perovskite single crystals and a perspective on future developments for carrier mobility enhancement is provided.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-resolution radiation detection using Ni/SiO 2 /n-4H-SiC vertical metal-oxide-semiconductor capacitor

In this article, we demonstrate the radiation detection performance of vertical metal-oxide-semiconductor (MOS) capacitors fabricated on 20 μm thick n-4H-SiC epitaxial layers with the highest energy resolution ever reported. The 100 nm SiO2 layer was achieved on the Si face of n-4H-SiC epilayers using dry oxidation in air. The Ni/SiO2/n-4H-SiC MOS detectors not only demonstrated an excellent energy resolution of 0.42% (ΔE/E 100) for 5.48 MeV alpha particles but also caused a lower enhancement in the electronic noise components of the spectrometer compared with that observed for the best high-resolution Schottky barrier detectors. The MOS detectors also exhibited a high charge collection efficiency (CCE) of 96% at the optimized operating bias despite the presence of the oxide layer. A drift-diffusion model applied to the CCE vs gate bias voltage data revealed a minority (hole) carrier diffusion length of 24 μm. Capacitance mode deep level transient spectroscopy (C-DLTS) scans in the temperature range 84–800 K were carried out to identify the resolution limiting electrically active defects. Interestingly, the C-DLTS spectra revealed both positive and negative peaks, indicating the simultaneous presence of electron (majority) and hole (minority) trap centers. It has been inferred that at the steady-state bias for the C-DLTS measurement, the MOS detector operates in the inversion mode at certain device temperatures, causing holes to populate the minority trap centers and, hence, manifests minority carrier peaks as well.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Charge breeders: Development of diagnostic tools to probe the underlying physics

Charge breeders were developed more than 20 years ago in the context of radioactive ion beam (RIB) production. The main goal is to boost the charge state of a singly charged RIB to a higher value matching the A/Q of a post-accelerator. In that way, the RIB produced at some tens of keV can efficiently be accelerated to energies in a range of few MeV/u up to several tens of MeV/u, which is of interest for nuclear structure and nuclear astrophysics experiments. Two families of charge breeders have been developed: one based on Electron Cyclotron Resonance Ion Sources (ECRISs) suitable for Continuous Wave (CW) operation and another built around Electron Beam Ion Sources (EBISs) used for pulsed post-accelerators. For many years, experimental studies have been carried out to enhance the charge breeding process and improve the extracted beam quality, i.e., purity, intensity, emittance, and time structure. The evolution of the charge breeders is also closely related to the emergence of new facilities delivering even more exotic beams. Diagnostic tools, such as Faraday cups, beam profile monitors, and emittance scanners, are mandatory to tune the machines and evaluate their performances. However, to go beyond that, a better understanding of plasma physics (in ECRIS) and electron-ion interactions (in EBIS), as well as the 1+ beam characteristics, for instance, energy spread transverse emittance, is needed. Therefore, simulation codes modeling the physics phenomena in both type of charge breeders were developed to support the understanding of experimental outputs and to gain insights into non-observable parameters. Nevertheless, more sophisticated diagnostic tools are required to improve the charge breeding performance and to extend the potential applications toward new RIB facilities. This Review will present the two kinds of charge breeders and their technical evolutions. It will review the diagnostic tools and simulation codes employed for operation and evaluation of the internal physics processes.

47 OTHER INSTRUMENTATION↗

Evaluation of a deuterated detector for gamma-ray beam intensity measurements

Laser-Compton scattering sources of quasi-monochromatic γ-ray beams have been in operation for over 30 years, with new facilities being under construction or proposed. To sustain a high-quality experimental physics program, continuous monitoring of these beams is essential by measuring the spectral, temporal, and spatial characteristics. In this work, we introduce a new method for determining the γ-ray beam intensity by using photodisintegration of deuterons in an active target detector approach. Measurements were performed using deuterated liquid scintillator detectors at several incident gamma energies between 4 and 13 MeV at the High Intensity γ-ray Source, Durham, USA. The results demonstrate that an instrument based on a deuterated active detector can be used to monitor the intensity of the γ-ray beam with high efficiency and operational simplicity.

Compton scattering↗

Development of a Clear Fiber Cherenkov Counter

We have developed a new PID detector consists of clear fibers. PID efficiency was measured with 470 MeV e{sup +} beam. As a result, this detector with thickness of 5 cm has the PID efficiency of 95 %. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Global Analysis of Light and Charge Yields in Liquid Xenon

Here, we present an updated model of light and charge yields from nuclear recoils in liquid xenon with a simultaneously constrained parameter set. A global analysis is performed using measurements of electron and photon yields compiled from all available historical data, as well as measurements of the ratio of the two. These data sweep over energies from keV and external applied electric fields from V/cm. The model is constrained by constructing global cost functions and using a simulated annealing algorithm and a Markov Chain Monte Carlo approach to optimize and find confidence intervals on all free parameters in the model. This analysis contrasts with previous work in that we do not unnecessarily exclude datasets nor impose artificially conservative assumptions, do not use spline functions, and reduce the number of parameters used in NEST v 0.98. Here, we report our results and the calculated best-fit charge and light yields. These quantities are crucial to understanding the response of liquid xenon detectors in the energy regime important for rare event searches such as the direct detection of dark matter particles.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Wide field array calibration dependence on the stability of measured dose distributions

Purpose: The aim of this work was to simulate the effect of dose distribution changes on detector array calibrations and to explore compensatory methods that are used during calibration measurements. Methods: The array calibration technique that was investigated is known as wide field (WF) calibration. Using this method, a linear array [y-axis (65 detectors) of the IC PROFILER (Sun Nuclear Corporation, Melbourne, FL)] is calibrated with three measurements ({alpha}, {theta}, and {lambda}); each measurement uses the same radiation field, which is larger than the array. For measurement configuration {theta}, the array is rotated by 180 deg. from its position in {alpha}; for {lambda}, the array is shifted by one detector from its position in {theta}. The relative detector sensitivities are then determined through ratios of detector readings at the same field locations (using {theta} and {lambda}). This method results in error propagation that is proportional to the number of detectors in the array. During the procedure, the calibration protocol operates under three postulates, which state that (a) the beam shape does not change between measurements; (b) the relative sensitivities of the detectors do not change; and (c) the scatter to the array does not change as the array is moved. The WF calibration's sensitivity to a postulate (a) violation was quantified by applying a sine shaped perturbation (of up to 0.1%) to {alpha}, {theta}, or {lambda}, and then determining the change relative to a baseline calibration. Postulate (a) violations were minimized by using a continuous beam and mechanized array movement during {theta} and {lambda}. A continuously on beam demonstrated more stable beam symmetry as compared to cycling the beam on and off between measurements. Additional side-scatter was also used to satisfy postulate (c). Results: Simulated symmetry perturbations of 0.1% to {theta} or {lambda} resulted in calibration errors of up to 2%; {alpha} was relatively immune to perturbation (<0.1% error). Wide field calibration error on a linear accelerator with similar symmetry variations was {+-}1.6%. Using a continuous beam during {theta} and {lambda} with additional side-scatter reduced the calibration error from {+-}1.6% to {+-}0.48%. Conclusions: This work increased the reproducibility of WF calibrations by limiting the effect of measurement perturbations primarily due to linear accelerator symmetry variations. The same technique would work for any array using WF calibration.

60 APPLIED LIFE SCIENCES↗

On charged particle equilibrium violation in external photon fields

Purpose: In a recent paper by Bouchard et al.[Med. Phys. 36(10), 4654-4663 (2009)], a theoretical model of quality correction factors for idealistic so-called plan-class specific reference (PCSR) fields was proposed. The reasoning was founded on the definition of PCSR fields made earlier by Alfonso et al.[Med. Phys. 35(11), 5179-5186 (2008)], requiring the beam to achieve charged particle equilibrium (CPE), in a time-averaged sense, in the reference medium. The relation obtained by Bouchard et al. was derived using Fano's theorem (1954) which states that if CPE is established in a given medium, the dose is independent of point-to-point density variations. A potential misconception on the achievability of the condition required by Fano (1954) might be responsible for false practical conclusions, both in the definition of PCSR fields as well as the theoretical model of quality correction factor. Methods: In this paper, the practical achievability of CPE in external beams is treated in detail. The fact that this condition is not achievable in single or composite deliveries is illustrated by an intuitive method and is also formally demonstrated. Conclusions: Fano's theorem is not applicable in external beam radiation dosimetry without (virtually) removing attenuation effects, and therefore, the relation conditionally defined by Bouchard et al. (2009) cannot be valid in practice. A definition of PCSR fields in the recent formalism for nonstandard beams proposed by Alfonso et al. (2008) should be modified, revising the criterion of CPE condition. The authors propose reconsidering the terminology used to describe standard and nonstandard beams. The authors argue that quality correction factors of intensity modulated radiation therapy PCSR fields (i.e., k{sub Q{sub p{sub c{sub s{sub r,Q}{sup f{sub p}{sub c}{sub s}{sub r},f{sub r}{sub e}{sub f}}}}}}) could be unity under ideal conditions, but it is concluded that further investigation is necessary to confirm that hypothesis.

61 RADIATION PROTECTION AND DOSIMETRY↗

Absolute beam emittance measurements at RHIC using ionization profile monitors

In the past, comparisons between emittance measurements obtained using ionization profile monitors, Vernier scans (using as input the measured rates from the zero degree counters, or ZDCs), the polarimeters and the Schottky detectors evidenced significant variations of up to 100%. In this report we present studies of the RHIC ionization profile monitors (IPMs). After identifying and correcting for two systematic instrumental errors in the beam size measurements, we present experimental results showing that the remaining dominant error in beam emittance measurements at RHIC using the IPMs was imprecise knowledge of the local beta functions. After removal of the systematic errors and implementation of measured beta functions, precise emittance measurements result. Also, consistency between the emittances measured by the IPMs and those derived from the ZDCs was demonstrated.

43 PARTICLE ACCELERATORS↗

PHENIX Fast TOF

This is a technical scope of work (TSW) between the Fermi National Accelerator Laboratory (Fermilab) and the experimenters of PHENIX Fast TOF group who have committed to participate in beam tests to be carried out during the FY2014 Fermilab Test Beam Facility program. The goals for this test beam experiment are to verify the timing performance of the two types of time-of-flight detector prototypes.

43 PARTICLE ACCELERATORS↗