Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Immortal Time Bias: A Frequently Unrecognized Threat to Validity in the Evaluation of Postoperative Radiotherapy

Purpose: To evaluate the influence of immortal time bias on observational cohort studies of postoperative radiotherapy (PORT) and the effectiveness of sequential landmark analysis to account for this bias. Methods and Materials: First, we reviewed previous studies of the Surveillance, Epidemiology, and End Results (SEER) database to determine how frequently this bias was considered. Second, we used SEER to select three tumor types (glioblastoma multiforme, Stage IA-IVM0 gastric adenocarcinoma, and Stage II-III rectal carcinoma) for which prospective trials demonstrated an improvement in survival associated with PORT. For each tumor type, we calculated conditional survivals and adjusted hazard ratios of PORT vs. postoperative observation cohorts while restricting the sample at sequential monthly landmarks. Results: Sixty-two percent of previous SEER publications evaluating PORT failed to use a landmark analysis. As expected, delivery of PORT for all three tumor types was associated with improved survival, with the largest associated benefit favoring PORT when all patients were included regardless of survival. Preselecting a cohort with a longer minimum survival sequentially diminished the apparent benefit of PORT. Conclusions: Although the majority of previous SEER articles do not correct for it, immortal time bias leads to altered estimates of PORT effectiveness, which are very sensitive to landmark selection. We suggest the routine use of sequential landmark analysis to account for this bias.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparative Effectiveness of 5 Treatment Strategies for Early-Stage Non-Small Cell Lung Cancer in the Elderly

Purpose: The incidence of early-stage non-small cell lung cancer (NSCLC) among older adults is expected to increase because of demographic trends and computed tomography-based screening; yet, optimal treatment in the elderly remains controversial. Using the Surveillance, Epidemiology, and End Results (SEER)-Medicare cohort spanning 2001-2007, we compared survival outcomes associated with 5 strategies used in contemporary practice: lobectomy, sublobar resection, conventional radiation therapy, stereotactic ablative radiation therapy (SABR), and observation. Methods and Materials: Treatment strategy and covariates were determined in 10,923 patients aged {>=}66 years with stage IA-IB NSCLC. Cox regression, adjusted for patient and tumor factors, compared overall and disease-specific survival for the 5 strategies. In a second exploratory analysis, propensity-score matching was used for comparison of SABR with other options. Results: The median age was 75 years, and 29% had moderate to severe comorbidities. Treatment distribution was lobectomy (59%), sublobar resection (11.7%), conventional radiation (14.8%), observation (12.6%), and SABR (1.1%). In Cox regression analysis with a median follow-up time of 3.2 years, SABR was associated with the lowest risk of death within 6 months of diagnosis (hazard ratio [HR] 0.48; 95% confidence interval [CI] 0.38-0.63; referent is lobectomy). After 6 months, lobectomy was associated with the best overall and disease-specific survival. In the propensity-score matched analysis, survival after SABR was similar to that after lobectomy (HR 0.71; 95% CI 0.45-1.12; referent is SABR). Conventional radiation and observation were associated with poor outcomes in all analyses. Conclusions: In this population-based experience, lobectomy was associated with the best long-term outcomes in fit elderly patients with early-stage NSCLC. Exploratory analysis of SABR early adopters suggests efficacy comparable with that of surgery in select populations. Evaluation of these therapies in randomized trials is urgently needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tumor Size on Abdominal MRI Versus Pathologic Specimen in Resected Pancreatic Adenocarcinoma: Implications for Radiation Treatment Planning

Purpose: We assessed the accuracy of abdominal magnetic resonance imaging (MRI) for determining tumor size by comparing the preoperative contrast-enhanced T1-weighted gradient echo (3-dimensional [3D] volumetric interpolated breath-hold [VIBE]) MRI tumor size with pathologic specimen size. Methods and Materials: The records of 92 patients who had both preoperative contrast-enhanced 3D VIBE MRI images and detailed pathologic specimen measurements were available for review. Primary tumor size from the MRI was independently measured by a single diagnostic radiologist (P.M.) who was blinded to the pathology reports. Pathologic tumor measurements from gross specimens were obtained from the pathology reports. The maximum dimensions of tumor measured in any plane on the MRI and the gross specimen were compared. The median difference between the pathology sample and the MRI measurements was calculated. A paired t test was conducted to test for differences between the MRI and pathology measurements. The Pearson correlation coefficient was used to measure the association of disparity between the MRI and pathology sizes with the pathology size. Disparities relative to pathology size were also examined and tested for significance using a 1-sample t test. Results: The median patient age was 64.5 years. The primary site was pancreatic head in 81 patients, body in 4, and tail in 7. Three patients were American Joint Commission on Cancer stage IA, 7 stage IB, 21 stage IIA, 58 stage IIB, and 3 stage III. The 3D VIBE MRI underestimated tumor size by a median difference of 4 mm (range, −34-22 mm). The median largest tumor dimensions on MRI and pathology specimen were 2.65 cm (range, 1.5-9.5 cm) and 3.2 cm (range, 1.3-10 cm), respectively. Conclusions: Contrast-enhanced 3D VIBE MRI underestimates tumor size by 4 mm when compared with pathologic specimen. Advanced abdominal MRI sequences warrant further investigation for radiation therapy planning in pancreatic adenocarcinoma before routine integration into the treatment planning process.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prospective Evaluation of Dual-Energy Imaging in Patients Undergoing Image Guided Radiation Therapy for Lung Cancer: Initial Clinical Results

Purpose: A prospective feasibility study was conducted to investigate the utility of dual-energy (DE) imaging compared to conventional x-ray imaging for patients undergoing kV-based image guided radiation therapy (IGRT) for lung cancer. Methods and Materials: An institutional review board-approved feasibility study enrolled patients with lung cancer undergoing IGRT and was initiated in September 2011. During daily setup, 2 sequential respiration-gated x-ray images were obtained using an on-board imager. Imaging was composed of 1 standard x-ray image at 120 kVp (1 mAs) and a second image obtained at 60 kVp (4 mAs). Weighted logarithmic subtraction of the 2 images was performed offline to create a soft tissue-selective DE image. Conventional and DE images were evaluated by measuring relative contrast and contrast-to-noise ratios (CNR) and also by comparing spatial localization, using both approaches. Imaging dose was assessed using a calibrated ion chamber. Results: To date, 10 patients with stage IA to IIIA lung cancer were enrolled and 57 DE images were analyzed. DE subtraction resulted in complete suppression of overlying bone in all 57 DE images, with an average improvement in relative contrast of 4.7 ± 3.3 over that of 120 kVp x-ray images (P<.0002). The improvement in relative contrast with DE imaging was seen for both smaller (gross tumor volume [GTV] ≤5 cc) and larger tumors (GTV >5 cc), with average relative contrast improvement ratios of 3.4 ± 4.1 and 5.4 ± 3.6, respectively. Moreover, the GTV was reliably localized in 95% of the DE images versus 74% of the single energy (SE images, (P=.004). Mean skin dose per DE image set was 0.44 ± 0.03 mGy versus 0.43 ± 0.03 mGy, using conventional kV imaging parameters. Conclusions: Initial results of this feasibility study suggest that DE thoracic imaging may enhance tumor localization in lung cancer patients receiving kV-based IGRT without increasing imaging dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simple Factors Associated With Radiation-Induced Lung Toxicity After Stereotactic Body Radiation Therapy of the Thorax: A Pooled Analysis of 88 Studies

Purpose: To study the risk factors for radiation-induced lung toxicity (RILT) after stereotactic body radiation therapy (SBRT) of the thorax. Methods and Materials: Published studies on lung toxicity in patients with early-stage non–small cell lung cancer (NSCLC) or metastatic lung tumors treated with SBRT were pooled and analyzed. The primary endpoint was RILT, including pneumonitis and fibrosis. Data of RILT and risk factors were extracted from each study, and rates of grade 2 to 5 (G2+) and grade 3 to 5 (G3+) RILT were computed. Patient, tumor, and dosimetric factors were analyzed for their correlation with RILT. Results: Eighty-eight studies (7752 patients) that reported RILT incidence were eligible. The pooled rates of G2+ and G3+ RILT from all 88 studies were 9.1% (95% confidence interval [CI]: 7.15-11.4) and 1.8% (95% CI: 1.3-2.5), respectively. The median of median tumor sizes was 2.3 (range, 1.4-4.1) cm. Among the factors analyzed, older patient age (P=.044) and larger tumor size (the greatest diameter) were significantly correlated with higher rates of G2+ (P=.049) and G3+ RILT (P=.001). Patients with stage IA versus stage IB NSCLC had significantly lower risks of G2+ RILT (8.3% vs 17.1%, odds ratio = 0.43, 95% CI: 0.29-0.64, P<.0001). Among studies that provided detailed dosimetric data, the pooled analysis demonstrated a significantly higher mean lung dose (MLD) (P=.027) and V20 (P=.019) in patients with G2+ RILT than in those with grade 0 to 1 RILT. Conclusions: The overall rate of RILT is relatively low after thoracic SBRT. Older age and larger tumor size are significant adverse risk factors for RILT. Lung dosimetry, specifically lung V20 and MLD, also significantly affect RILT risk.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Constrained optimization framework for interface-aware sub-scale dynamics models for voids closure in Lagrangian hydrodynamics

In hydrocodes, voids are used to represent vacuum and model free boundaries between vacuum and real materials. We give a systematic description of a new treatment of void closure in the framework of the multimaterial arbitrary Lagrangian–Eulerian (ALE) methods. This includes a new formulation of the interface-aware sub-scale-dynamics (IA-SSD) closure model for multimaterial cells with voids, which is used in the Lagrangian stage of our indirect ALE scheme. The results of the comprehensive testing of the new model are presented for one- and two-dimensional multimaterial calculations in the presence of voids. Finally, we also present a sneak peek of a realistic shaped charge calculation in the presence of voids and solids.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Structures of Coiled-Coil Domains from Type III Secretion System Translocators Reveal Homology to Pore-Forming Toxins

Many pathogenic Gram-negative bacteria utilize type III secretion systems (T3SSs) to alter the normal functions of target cells. Shigella flexneri uses its T3SS to invade human intestinal cells to cause bacillary dysentery (shigellosis) that is responsible for over one million deaths per year. The Shigella type III secretion apparatus is composed of a basal body spanning both bacterial membranes and an exposed oligomeric needle. Host altering effectors are secreted through this energized unidirectional conduit to promote bacterial invasion. The active needle tip complex of S. flexneri is composed of a tip protein, IpaD, and two pore-forming translocators, IpaB and IpaC. While the atomic structure of IpaD has been elucidated and studied, structural data on the hydrophobic translocators from the T3SS family remain elusive. We present here the crystal structures of a protease-stable fragment identified within the N-terminal regions of IpaB from S. flexneri and SipB from Salmonella enterica serovar Typhimurium determined at 2.1 {angstrom} and 2.8 {angstrom} limiting resolution, respectively. These newly identified domains are composed of extended-length (114 {angstrom} in IpaB and 71 {angstrom} in SipB) coiled-coil motifs that display a high degree of structural homology to one another despite the fact that they share only 21% sequence identity. Further structural comparisons also reveal substantial similarity to the coiled-coil regions of pore-forming proteins from other Gram-negative pathogens, notably, colicin Ia. This suggests that these mechanistically separate and functionally distinct membrane-targeting proteins may have diverged from a common ancestor during the course of pathogen-specific evolutionary events.

59 BASIC BIOLOGICAL SCIENCES↗

Preparation, crystal structure and photoluminescence of garnet-type calcium tin titanium aluminates

Colorless and transparent single crystals of Ca{sub 3}Sn{sub 2.2}Ti{sub 0.8}Al{sub 2}O{sub 12}, which emit blue-white light under ultraviolet light, were prepared by heating a mixture of oxides and calcium carbonate with a calcium and aluminum-rich composition at 1500 {sup o}C. Single crystal X-ray diffraction revealed that the crystal structure is the garnet-type with a cubic cell parameter (a=12.5309(3) A) and the space group, Ia 3-bar d (R1=0.0277, wR2=0.0663, and S=1.367 for all data). The structural formula is presented as Ca{sub 3}[Sn{sub 0.96}Ti{sub 0.04}]{sub octa}[Al{sub 0.67}Ti{sub 0.24}Sn{sub 0.09}]{sub tetra}O{sub 12}. Polycrystalline solid solutions of Ca{sub 3}Sn{sub 3-x}Ti{sub x}Al{sub 2}O{sub 12} were prepared by solid state reaction in air at 1370 {sup o}C with nominal titanium contents from x=0.6 to 1.4. The refined unit cell parameter decreased with increasing x. A broad blue-white emission with a peak wavelength of 465 nm was observed for the solid solutions at room temperature. -- Graphical abstract: Garnet-type solid solutions of Ca{sub 3}Sn{sub 3-x}Ti{sub x}Al{sub 2}O{sub 12} (x=0.6-1.4) were prepared. Sn{sup 4+} and Ti{sup 4+} partially occupy both tetrahedral and octahedral sites. The solid solutions showed a broad emission band peaking at 465 nm under UV excitation. Display Omitted Research highlights: {yields} New garnet-type solid solutions were found in the CaO-Al{sub 2}O{sub 3}-TiO{sub 2}-SnO{sub 2} system. {yields} Single crystals of Ca{sub 3}Sn{sub 2.2}Ti{sub 0.8}Al{sub 2}O{sub 12} were obtained by the self-flux method. {yields} Solid solutions with nominal compositions Ca{sub 3}Sn{sub 3-x}Ti{sub x}Al{sub 2}O{sub 12} (x=0.6-1.4) were prepared by solid state reaction at 1370 {sup o}C. {yields} Sn{sup 4+} and Ti{sup 4+} partially occupy both tetrahedral and octahedral sites, respectively, in the garnet-type structure. {yields} Ca{sub 3}Sn{sub 3-x}Ti{sub x}Al{sub 2}O{sub 12} solid solutions emitted blue-white light with a peak wavelength at 465 nm under UV irradiation.

36 MATERIALS SCIENCE↗

An X-ray diffraction, magnetic susceptibility and spectroscopic studies of Yb{sub 2-x}Cr{sub x}O{sub 3}

Polycrystalline samples with general formula Yb{sub 2-x}Cr{sub x}O{sub 3} (0<x<0.03), obtained by sol-gel method and analyzed by X-ray diffraction, formed solid solutions over all the mentioned range. Cr showed a maximum solubility of 2.8 mol% in Yb{sub 2}O{sub 3} sesquioxide at 1000 deg. C. A preferential substitution of Cr{sup 3+} ions over two cationic sites, 8b and 24d in the space group Ia-3 was found. The lattice parameters a are found to vary linearly (10.4402(4) A <a<10.4372(1) A) with the composition x. The two independent atoms Yb/Cr have octahedral coordination; however, the degrees of distortion of their coordination polyhedron are different. Replacing Yb{sup 3+} by Cr{sup 3+} introduces slight changes in the atomic coordinates leading to an increase of the mean cation-anion distances. The ability of Raman spectroscopy to detect changes in local coordination is utilized. A pseudo-tetrahedral coordination for the Cr{sup 3+} in the 24d site was found. Magnetic susceptibility measurements of all samples were done in a temperature range of 2-50 K. For T<37 K, the inverse paramagnetic susceptibilities depend linearly on temperature. However, in the high-temperature region, for T>37 K, the inverse paramagnetic susceptibilities are non-linear versus temperature. This deviation from the Curie-Weiss behaviour was discussed. - Graphical abstract: The least square fit to the modified Curie-Weiss law shows paramagnetic interaction in Yb{sub 2-x}Cr{sub x}O{sub 3} (0<x{<=}0.03). The YbCrO{sub 3} phase impurity will have no influence on the magnetic properties of the samples with x>0.03 Highlights: > We described our attempts to synthesize Yb{sub 2-x}Cr{sub x}O{sub 3} series of compounds.{yields} The products were characterized by X-ray diffraction, Raman and magnetic measurements. > Cr showed a maximum solubility of 2.8 mol% in Yb{sub 2}O{sub 3} sesquioxide at 1000 deg. C. > The least square fit to the modified Curie-Weiss law shows paramagnetic interaction. > The YbCrO{sub 3} phase impurity has no influence on the magnetic properties of the samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In-situ X-ray diffraction study of phase transformations in the Am-O system

In the frame of minor actinides recycling, americium can be transmuted by adding it in UO{sub 2} or (U, Pu)O{sub 2} fuels. Americium oxides exhibiting a higher oxygen potential than U or Pu oxides, its addition alters the fuel properties. To comprehend its influence, a thorough knowledge of the Am-O phase equilibria diagram and of thermal expansion behavior is of main interest. Due to americium scarcity and high radiotoxicity, few experimental reports on this topic are available. Here we present in-situ high-temperature XRD results on the reduction from AmO{sub 2} to Am{sub 2}O{sub 3}. We show that fluorite (Fm-3m) AmO{sub 2} is reduced to cubic (Ia-3) C Prime -type Am{sub 2}O{sub 3+{delta}}, and then into hexagonal (P6{sub 3}/mmc) A-type Am{sub 2}O{sub 3}, which remains stable up to 1840 K. We also demonstrate the transitional existence of the monoclinic (C2/m) B-type Am{sub 2}O{sub 3}. At last, we describe, for the first time, the thermal expansion behavior of the hexagonal Am{sub 2}O{sub 3} between room temperature and 1840 K. - Graphical abstract: Americium dioxide was in situ studied by high-temperature X-ray diffraction. First, fluorite AmO{sub 2} is reduced to cubic C Prime -type Am{sub 2}O{sub 3+{delta}} and then transforms into hexagonal A-type Am{sub 2}O{sub 3}, which remains stable up to 1840 K. Then, we demonstrate the transitional existence of monoclinic B-type Am{sub 2}O{sub 3}. At last, we describe, for the first time, the thermal expansion of A-type Am{sub 2}O{sub 3} between room temperature and 1840 K. This work may contribute to a better understanding of Am oxide behavior. Highlights: Black-Right-Pointing-Pointer We realize an in-situ high-temperature X-ray diffraction study on an AmO{sub 2} sample. Black-Right-Pointing-Pointer Fluorite AmO{sub 2} transforms to cubic Am{sub 2}O{sub 3+{delta}} and then to hexagonal Am{sub 2}O{sub 3}. Black-Right-Pointing-Pointer Little-known monoclinic Am{sub 2}O{sub 3} is observed during the cubic-to-hexagonal transition. Black-Right-Pointing-Pointer Lattice parameter thermal expansion of hexagonal Am{sub 2}O{sub 3} is given up to 1840 K. Black-Right-Pointing-Pointer We give additional data on AmO{sub 2} lattice parameter expansion under self-irradiation.

36 MATERIALS SCIENCE↗

Self-irradiation and oxidation effects on americium sesquioxide and Raman spectroscopy studies of americium oxides

Americium oxides samples were characterized by X-ray diffraction (XRD) and Raman spectroscopy, with an emphasis on their structural behavior under oxidation and self-irradiation. Raman spectra of americium dioxide (AmO{sub 2}) and sesquioxide (Am{sub 2}O{sub 3}) were obtained for the first time. With the help of literature data on isostructural oxides, Raman signatures of Ia-3 C-type Am{sub 2}O{sub 3} and P-3m1 A-type Am{sub 2}O{sub 3} are identified. For AmO{sub 2,} a clear band is noted at 390 cm{sup −1}. Its nature is compared to that of the other actinide dioxides. Am{sub 2}O{sub 3} evolution under ambient conditions and against {sup 241}Am α self-irradiation was monitored by powder XRD. The sample, initially composed of A-type Am{sub 2}O{sub 3} as major phase as well as C2/m B-type and C-type structures as minor phases, progressively oxidizes to Fm-3m AmO{sub 2−δ} over a few months. On the basis of diffractogram refinements, evolutions of unit cell volumes caused by self-irradiation are also determined and discussed. - Graphical abstract: The evolution of americium oxide under ambient conditions was monitored using XRD (X-ray diffraction) and Raman spectroscopy. After a thermal treatment under reducing conditions, a polyphasic sample mainly composed of A- and C-type americium sesquioxides is evidenced by XRD and Raman spectroscopy. The sample then evolves through two processes: oxidation and self-irradiation. The first one provokes the progressive appearance of F-type americium dioxide while the initial phases disappear, whereas the main effect of the second is a structural swelling with time. - Highlights: • The first Raman spectroscopy measurements on americium oxides were performed. • Observed Am{sub 2}O{sub 3} Raman bands were identified thanks to data on analogue compounds. • AmO{sub 2} assumed T{sub 2g} band presents a shift compared to the actinide dioxide series. • Am{sub 2}O{sub 3} evolution under self-irradiation and oxidation was also monitored by XRD. • The three Am{sub 2}O{sub 3} phases observed have different behaviors under self-irradiation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The solubility and site preference of Fe{sup 3+} in Li{sub 7−3x}Fe{sub x}La{sub 3}Zr{sub 2}O{sub 12} garnets

A series of Fe{sup 3+}-bearing Li{sub 7}La{sub 3}Zr{sub 2}O{sub 12} (LLZO) garnets was synthesized using solid-state synthesis methods. The synthetic products were characterized compositionally using electron microprobe analysis and inductively coupled plasma optical emission spectroscopy (ICP-OES) and structurally using X-ray powder diffraction and {sup 57}Fe Mössbauer spectroscopy. A maximum of about 0.25 Fe{sup 3+} pfu could be incorporated in Li{sub 7−3x}Fe{sub x}La{sub 3}Zr{sub 2}O{sub 12} garnet solid solutions. At Fe{sup 3+} concentrations lower than about 0.16 pfu, both tetragonal and cubic garnets were obtained in the synthesis experiments. X-ray powder diffraction analysis showed only a garnet phase for syntheses with starting materials having intended Fe{sup 3+} contents lower than 0.52 Fe{sup 3+} pfu. Back-scattered electron images made with an electron microprobe also showed no phase other than garnet for these compositions. The lattice parameter, a{sub 0}, for all solid-solution garnets is similar with a value of a{sub 0}≈12.98 Å regardless of the amount of Fe{sup 3+}. {sup 57}Fe Mössbauer spectroscopic measurements indicate the presence of poorly- or nano-crystalline FeLaO{sub 3} in syntheses with Fe{sup 3+} contents greater than 0.16 Fe{sup 3+} pfu. The composition of different phase pure Li{sub 7−3x}Fe{sub x}La{sub 3}Zr{sub 2}O{sub 12} garnets, as determined by electron microprobe (Fe, La, Zr) and ICP-OES (Li) measurements, give Li{sub 6.89}Fe{sub 0.03}La{sub 3.05}Zr{sub 2.01}O{sub 12}, Li{sub 6.66}Fe{sub 0.06}La{sub 3.06}Zr{sub 2.01}O{sub 12}, Li{sub 6.54}Fe{sub 0.12}La{sub 3.01}Zr{sub 1.98}O{sub 12}, and Li{sub 6.19}Fe{sub 0.19}La{sub 3.02}Zr{sub 2.04}O{sub 12}. The {sup 57}Fe Mössbauer spectrum of cubic Li{sub 6.54}Fe{sub 0.12}La{sub 3.01}Zr{sub 1.98}O{sub 12} garnet indicates that most Fe{sup 3+} occurs at the special crystallographic 24d position, which is the standard tetrahedrally coordinated site in garnet. Fe{sup 3+} in smaller amounts occurs at a general 96h site, which is only present for certain Li-oxide garnets, and in Li{sub 6.54}Fe{sub 0.12}La{sub 3.01}Zr{sub 1.98}O{sub 12} this Fe{sup 3+} has a distorted 4-fold coordination. - Graphical abstract: Cubic nominally Li{sub 7}La{sub 3}Zr{sub 2}O{sub 12} (LLZO) garnet is a promising candidate to be used as a solid electrolyte in Li-ion batteries. A series of Fe{sup 3+}-bearing LLZO garnets was synthesized and characterized compositionally and structurally. {sup 57}Mössbauer measurements were made to determine where Fe is incorporated in the crystal structure. X-ray diffraction, electron microprobe, ICP-OES and {sup 57}Mössbauer measurements are needed to obtain a full description of the synthetic products, some of which contain small amounts of nano- or poorly crystalline FeLaO{sub 3}. - Highlights: • A series of Fe{sup 3+}-bearing Li{sub 7}La{sub 3}Zr{sub 2}O{sub 12} (LLZO) garnets was synthesized and characterized compositionally and structurally. • {sup 57}Mössbauer measurements were made to determine where Fe is incorporated in the crystal structure. • Most Fe{sup 3+} substitutes for Li{sup +} in LLZO at the 24d and 96h sites in the cubic phase (Ia-3d). • No more than about 0.25 Fe{sup 3+} pfu can be incorporated into the LLZO garnet structure. • X-ray powder diffractions measurements indicate the presence of both cubic and tetragonal garnets phases in some syntheses. • The probable presence of small amounts of poorly or nano-crystalline FeLaO3 can only be identified by Mössbauer spectroscopy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Syntheses, structure and magnetic properties of two vanadate garnets Ca{sub 5}M{sub 4}V{sub 6}O{sub 24} (M=Co, Ni)

Two vanadate compounds Ca{sub 5}M{sub 4}V{sub 6}O{sub 24} (M=Co, Ni) have been synthesized by a high-temperature solid-state reaction. The compounds are found to crystallize in the cubic system with a space group Ia-3d, which exhibit a typical garnet structural framework. Magnetic measurements show that Ca{sub 5}M{sub 4}V{sub 6}O{sub 24} (M=Co, Ni) exhibit similar magnetic behaviors, in which Ca{sub 5}Co{sub 4}V{sub 6}O{sub 24} possesses an antiferromagnetic ordering at T{sub N}=~6 K while Ca{sub 5}Ni{sub 4}V{sub 6}O{sub 24} shows an antiferromagnetic ordering at T{sub N}=~7 K. - Graphical abstract: Garnet vanadate compounds Ca{sub 5}M{sub 4}V{sub 6}O{sub 24} (M=Co, Ni) have been synthesized by a high-temperature solid-state reaction. Structural features and magnetic behaviors are also investigated. - Highlights: • New type of garnet vanadates Ca{sub 5}M{sub 4}V{sub 6}O{sub 24} (M=Co, Ni) are synthesized by a high-temperature solid-state reaction. • Structural features are confirmed by single crystal samples. • Magnetic behaviors are firstly investigated in the systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nuclear Data Sheets for A = 44

The experimental data are evaluated for known nuclides of mass number A=44 (Si,P,S,Cl,Ar,K,Ca,Sc,Ti,V, Cr,Mn). Detailed evaluated level properties and related information are presented, including adopted values of level and {gamma}-ray energies, decay data (energies, intensities and placement of radiations), and other spectroscopic data. This work supersedes earlier full evaluations of A=44 published by 1999Ca45 and 1990En08 (also 1998En04 update). No excited states are known in {sup 44}Si, {sup 44}P, {sup 44}Cr, {sup 44}Mn. Only one excited state is known in 44V and its Isobaric Analog State (IAS) has been observed but with the level energy not known. Information for {sup 44}S, {sup 44}Cl and {sup 44}Ar is limited and their radioactive decay schemes seem incomplete in view of large Q values and known excitations much below than allowed by Q values. The {sup 44}Ca, {sup 44}Sc and {sup 44}Ti nuclides remain as the most extensively studied from many different reactions and decays.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear Data Sheets for A = 43

The experimental data are evaluated for known nuclides of mass number A = 43 (Al,Si,P,S,Cl,Ar,K,Ca,Sc,Ti,V,Cr). Detailed evaluated level properties and related information are presented, including adopted values of level and γ–ray energies, decay data (energies, intensities and placement of radiations), and other spectroscopic data. Here, this work supersedes earlier full evaluations of A = 43 published by 2001Ca24 and 1990En08 (also 1978En04, and 1998En04 update).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SNAD transient miner: Finding missed transient events in ZTF DR4 using k-D trees

Here we report the automatic detection of 11 transients (7 possible supernovae and 4 active galactic nuclei candidates) within the Zwicky Transient Facility fourth data release (ZTF DR4), all of them observed in 2018 and absent from public catalogs. Among these, three were not part of the ZTF alert stream. Our transient mining strategy employs 41 physically motivated features extracted from both real light curves and four simulated light curve models (SN Ia, SN II, TDE, SLSN-I). These features are input to a k-D tree algorithm, from which we calculate the 15 nearest neighbors. After pre-processing and selection cuts, our dataset contained approximately a million objects among which we visually inspected the 105 closest neighbors from seven of our brightest, most well-sampled simulations, comprising 89 unique ZTF DR4 sources. Our result illustrates the potential of coherently incorporating domain knowledge and automatic learning algorithms, which is one of the guiding principles directing the SNAD team. It also demonstrates that the ZTF DR is a suitable testing ground for data mining algorithms aiming to prepare for the next generation of astronomical data.

79 ASTRONOMY AND ASTROPHYSICS↗

DECam Integration Tests on Telescope Simulator

The Dark Energy Survey (DES) is a next generation optical survey aimed at measuring the expansion history of the universe using four probes: weak gravitational lensing, galaxy cluster counts, baryon acoustic oscillations, and Type Ia supernovae. To perform the survey, the DES Collaboration is building the Dark Energy Camera (DECam), a 3 square degree, 570 Megapixel CCD camera which will be mounted at the Blanco 4-meter telescope at the Cerro Tololo Inter- American Observatory. DES will survey 5000 square degrees of the southern galactic cap in 5 filters (g, r, i, z, Y). DECam will be comprised of 74 250 micron thick fully depleted CCDs: 62 2k x 4k CCDs for imaging and 12 2k x 2k CCDs for guiding and focus. Construction of DECam is nearing completion. In order to verify that the camera meets technical specifications for DES and to reduce the time required to commission the instrument, we have constructed a full sized telescope simulator and performed full system testing and integration prior to shipping. To complete this comprehensive test phase we have simulated a DES observing run in which we have collected 4 nights worth of data. We report on the results of these unique tests performed for the DECam and its impact on the experiments progress.

79 ASTRONOMY AND ASTROPHYSICS↗