Robust Combined Heat and Hybrid Power (CHHP) for High Electrical Efficiency Cogeneration

Georgia Tech (Prime Recipient), the University of Texas at El Paso (UTEP) and the National Energy Technology Laboratory (NETL) investigated a hybrid fuel cell/ gas turbine system concept as a combined heat and hybrid power (CHHP) system for both robust and high power-to-process heat ratio cogeneration. The novelty of the proposed system entailed the distinct, elevated electrical efficiencies it maintains while simultaneously supporting a broad span of heating needs (e.g., supply temperatures) demanded across variable heat loads. The scope included: 1) leveraging a pioneering national lab facility configured for dynamic system operability development of hybrid fuel cell/gas turbine cycles; 2) enabling technology development to adjust and modulate the quality and quantity of thermal supply to bottoming heat loads via novel extreme temperature gas bypass valves. Hybrid fuel cell/gas turbine systems have primarily been reduced-to-practice in a constrained (e.g., initial proof-of-concept) manner and have still demonstrated considerable electrical efficiencies. However, these pre-pilot systems have focused upon electrical efficiencies and electrical power generation as the exclusive energy demand. Such hybrid systems had not been extensively researched or developed for flexible and variable operation consisting of both power and heat demands; however, these variable combined power and heat demands are characteristic of many types of manufacturers such as animal/poultry processing, bakeries and milk/flour/pastry manufacturing, textile mills, and electrochemical processing. Commercially, developing the system into a working combined heat and power system benefits these types of manufacturers by allowing them to meet their power and heat demands at a lower cost, higher efficiency, and/or through onsite generation. Therefore, the technical scope of this project was largely to study and facilitate these hybrid systems as combined heat and hybrid power (CHHP) systems that include dynamic operability for variable heat and power loads and/or grid dynamics for various types of manufacturers. Simulation results were used to predict the performance of the CHHP system and conceptually develop it to achieve desired dynamic operability. Experimentally, the primary goal was to design, manufacture, and experiment upon a high-temperature bypass valve. Experimental data included air mass flow rates through the valve orifice when the valve was changed to variable extent between fully closed and fully open. The experimental data was then used to create a semi-empirical computational model of the bypass valve. Concluded simulation goals for the research included developing computational heat exchanger models for the hybrid system inclusive of the bottoming heat exchanger and the recuperative heat exchanger, and then combining the computational recuperator model with the computational valve model. Afterwards, the computational models were then integrated to predict the dynamic operation of hybrid fuel cell/gas turbine cycles throughout a design space and reporting such. The scope stated in the preceding paragraph was packaged into five specific goals: 1) enabling the simulation of dynamic combined heat and power through the creation of computational, modular heat exchanger models; 2) simulation and exploration of the CHHP system’s performance by integrating the heat exchanger models with the national lab’s pre-existing hybrid system (computational) simulation, but without the recuperator bypass valve concept in order to initially determine how the (baseline) system behaves and can be controlled in order to meet variable heat and power demands; 3) development and initial deployment of the high-temperature recuperator bypass valve technology in order to confirm and characterize the approach; 4) usage of the experimental data for the valve to create a semi-empirical computational model for the bypass valve which could then be combined with the heat exchanger computational models; 5) repeat of the second task of simulating and exploring the system’s performance, but this time including the bypass valve to resolve its efficacy. Tasks were successfully completed, and the general notion of flexibly operating, high electrical efficiency CHHP was further corroborated. Supportive details are provided in the report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Bubble Dynamics, Two-Phase Flow, and Boiling Heat Transfer in Microgravity

This report contains two independent sections. Part one is titled "Terrestrial and Microgravity Pool Boiling Heat Transfer and Critical heat flux phenomenon in an acoustic standing wave." Terrestrial and microgravity pool boiling heat transfer experiments were performed in the presence of a standing acoustic wave from a platinum wire resistance heater using degassed FC-72 Fluorinert liquid. The sound wave was created by driving a half wavelength resonator at a frequency of 10.15 kHz. Microgravity conditions were created using the 2.1 second drop tower on the campus of Washington State University. Burnout of the heater wire, often encountered with heat flux controlled systems, was avoided by using a constant temperature controller to regulate the heater wire temperature. The amplitude of the acoustic standing wave was increased from 28 kPa to over 70 kPa and these pressure measurements were made using a hydrophone fabricated with a small piezoelectric ceramic. Cavitation incurred during experiments at higher acoustic amplitudes contributed to the vapor bubble dynamics and heat transfer. The heater wire was positioned at three different locations within the acoustic field: the acoustic node, antinode, and halfway between these locations. Complete boiling curves are presented to show how the applied acoustic field enhanced boiling heat transfer and increased critical heat flux in microgravity and terrestrial environments. Video images provide information on the interaction between the vapor bubbles and the acoustic field. Part two is titled, "Design and qualification of a microscale heater array for use in boiling heat transfer." This part is summarized herein. Boiling heat transfer is an efficient means of heat transfer because a large amount of heat can be removed from a surface using a relatively small temperature difference between the surface and the bulk liquid. However, the mechanisms that govern boiling heat transfer are not well understood. Measurements of wall temperature and heat flux near the wall would add to the database of knowledge which is necessary to understand the mechanisms of nucleate boiling. A heater array has been developed which contains 96 heater elements within a 2.5 mm square area. The temperature of each heater element is held constant by an electronic control system similar to a hot-wire anemometer. The voltage that is being applied to each heater element can be measured and digitized using a high-speed Analog to Digital (A/D) converter, and this digital information can be compiled into a series of heat-flux maps. Information for up to 10,000 heat flux maps can be obtained each second. The heater control system, the A/D system and the heater array construction are described in detail. Results are presented which show that this is an effective method of measuring the local heat flux during nucleate and transition boiling. Heat flux maps are obtained for pool boiling in FC-72 on a horizontal surface. Local heat flux variations are shown to be three to six times larger than variations in the spatially averaged heat flux.

Chung, Jacob N.↗

A System Approach to Deep Heating Savings Through Measurement, Management, and Motivation

Across multi-tenant commercial office and multifamily buildings, centrally metered fuel use represents a substantial fraction of whole-building energy use. Energy audit practitioners understand that improving heating distribution efficiency is typically more of an opportunity than combustion efficiency and that differing thermal comfort preferences between tenants are the bane of operators across these building typologies. There is an unmet market need for retrofit technologies that allow for the delivery of the right amount of heat to the right spaces, at the right time. The Energy Management and Information System (EMIS) package fills this gap through enhanced controls and metering, incorporating low-cost sensors and wireless communication infrastructure to provide a platform for ongoing commissioning and tenant feedback, including heat cost allocation. With support from the US DOE Building Technologies Office, Steven Winter Associates, Inc. (SWA) partnered with Sentient Buildings, E Source, building owners, and utility and policy stakeholders, to demonstrate a market viable EMIS that achieves a reduction in space heating energy use by reducing heating load, improving control, and positively impacting behavior while providing an acceptable financial return. In this study, EMIS packages were implemented in two New York City multifamily rental buildings. Both buildings conducted basic mechanical work (e.g., repairing steam traps) to ensure the heating system was operating well before any tenant feedback was layered in. Heating Energy Use Reports (HEUR) were created to provide tenants with social comparisons and energy savings tips to influence their behavior; these were provided monthly to all tenants in both buildings. Additionally, one building allocated heating costs to a portion of the tenants. Heat cost allocation (HCA) has a long history in the European Union (EU), although it is not common in the US or in steam-heated buildings. SWA leveraged existing EU best practices and stakeholder feedback to develop a Heat Cost Allocation algorithm that was considered equitable and intuitive. Energy use and tenant behavior impacts were tracked throughout the study. The basic mechanical repair work saved between 11-20% of heating energy. Those savings rose to 17-24% with the addition of tenant feedback. While it may not be possible to precisely determine the impact of COVID-19 on research studies like this, there may have been additional savings realized had the study taken place in a period of normal occupancy patterns. These types of central heating systems have been a blind spot for utilities, who have traditionally had little visibility into detailed behind-the-meter gas usage. Heating energy savings stayed consistent during the coldest months, indicating the potential for utilities to utilize EMIS packages for peak gas demand reductions or demand response programs. Tenant comfort was also improved. Post installation, room temperatures more closely matched thermostat set points. Perhaps due to this greater level of control, the vast majority of tenants being billed for heating were accepting of the allocation costs. And tenants receiving heat cost allocations were more likely to reduce their thermostat setpoints than tenants receiving behavioral feedback without financial impacts were. Variation in building specifics makes it difficult to provide precise energy and financial savings estimates. But within the range of expected conditions, the study identified a few key variables that can have the greatest impact on financial returns: the cost of fuel, the ability and willingness to allocate heating costs to tenants, and a well-functioning heating system as a starting point. This study focused on two multifamily buildings, but additional use cases, such as commercial buildings and affordable housing, should be explored to better understand the full market potential. While this type of upgrade has the potential for deep energy reductions and cost savings, future projects should take into account the balance of costs and benefits between owners and tenants, especially in the affordable, regulated, or other low-to-moderate income (LMI) segments of the market. Rent credits, utility allowances, or a shared savings program are possible options to accelerate adoption of this strategy in these market segments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Active Lithium Injection for a Real Time Control of the Divertor Heat Flux for Fusion Devices

When the local heat flux exceeds specified flux limit, tungsten PFC surfaces can be damaged, which is not acceptable for a reliable reactor operations. The divertor PFCs are typically designed for a specific heat flux limit usually assuming an average steady-state heat flux which is typically 5–10 MW/m 2 . However, in addition to steady-state heat flux, fusion reactor divertor PFCs could experience transient heat fluxes such as ELMs and/or other magnetic reconnection events which can deposit large transient heat fluxes onto the divertor PFCs. The transient divertor heat flux could be significantly larger than the steady-state heat flux which could damage the solid PFC surfaces. The divertor heat flux can be subjected to additional complications such as the uncertainties in the the divertor strike point heat flux projection. Moreover, there are additional experimental observations of non-axisymmetric power flux which can occur under non-axisymmetric magnetic perturbations. The liquid lithium (LL) PFCs is more resilient against such transient heat fluxes as they could evaporate LL as needed and the lost LL can be then replenished afterward. In this paper, we analyze a case for a transient divertor heat pulse of 1 MJ in 10 ms for a ITER-size reactor. This is a small perturbation (~ 0.1%) to the expected plasma stored energy compared to the previously analyzed case of 20 MJ heat pulse. Even with this relatively modest heat pulse, the LL surface undergoes ~ 100 °C temperature rise. However, the resulting LL surface heating without rapid cooldown mechanism could lead to excessive LL evaporation continuing well after the transient heat flux resulting in a significant Li injection of ~ 0.6 mol in about a 200 ms period. This amount of Li injection could cause plasma dilution and performance degradation. On the other hand, an active Li injection capability if optimized could prevent the LL surface temperature rise and thus reducing subsequent Li evaporation into the plasma by a factor of 7 compared to the passive LL PFC case. A crucial tool of active Li injection is a rapid response pellet injector which could inject light impurity pellets before the excessive heat flux could reach the divertor plate causing serious damage. A simple pellet ablation model suggests a favorable pellet deposition profile for smaller ~ 0.1 mm radius pellet with ~ 10–20 m/s velocity. Moreover, if it is possible to inject from the private flux region, the pellet injection efficiency into the high heat flux strike point region can be as high as 80% compared to ~ 50% for the injection from outer radius region. The pellet deposition efficiency can be further improved by designing a shell-pellet which can burst when a certain ablation fraction is reached. Finally, a possible implementation technique using an inductive pellet injector with a rapid time response of a few msec is proposed here which can be tested in NSTX-U.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Solar assisted heat pump on air collectors: A simulation tool

The heating system of the bioclimatic building of the Greek National Centre for Renewable Energy Sources (CRES) comprises two heating plants: the first one includes an air source heat pump, Solar Air Collectors (SACs) and a heat distribution system (comprising a fan coil unit network); the second one is, mainly, a geothermal heat pump unit to cover the ground floor thermal needs. The SAC configuration as well as the fraction of the building heating load covered by the heating plant are assessed in two operation modes; the direct (hot air from the collectors is supplied directly to the heated space) and the indirect mode (warm air from the SAC or its mixture with ambient air is not supplied directly to the heated space but indirectly into the evaporator of the air source heat pump). The technique of the indirect mode of heating aims at maximizing the efficiency of the SAC, saving electrical power consumed by the compressor of the heat pump, and therefore, at optimizing the coefficient of performance (COP) of the heat pump due to the increased intake of ambient thermal energy by means of the SAC. Results are given for three research objectives: assessment of the heat pump efficiency whether in direct or indirect heating mode; Assessment of the overall heating plant efficiency on a daily or hourly basis; Assessment of the credibility of the suggested simulation model TSAGAIR by comparing its results with the TRNSYS ones. (author)

14 SOLAR ENERGY↗

On Heating the Sun's Corona by Magnetic Explosions: Feasibility in Active Regions and prospects for Quiet Regions and Coronal Holes

We build a case for the persistent strong coronal heating in active regions and the pervasive quasi-steady heating of the corona in quiet regions and coronal holes being driven in basically the same way as the intense transient heating in solar flares: by explosions of sheared magnetic fields in the cores of initially closed bipoles. We begin by summarizing the observational case for exploding sheared core fields being the drivers of a wide variety of flare events, with and without coronal mass ejections. We conclude that the arrangement of an event's flare heating, whether there is a coronal mass ejection, and the time and place of the ejection relative to the flare heating are all largely determined by four elements of the form and action of the magnetic field: (1) the arrangement of the impacted, interacting bipoles participating in the event, (2) which of these bipoles are active (have sheared core fields that explode) and which are passive (are heated by injection from impacted active bipoles), (3) which core field explodes first, and (4) which core-field explosions are confined within the closed field of their bipoles and which ejectively open their bipoles. We then apply this magnetic-configuration framework for flare heating to the strong coronal heating observed by the Yohkoh Soft X-ray Telescope in an active region with strongly sheared core fields observed by the MSFC vector magnetograph. All of the strong coronal heating is in continually microflaring sheared core fields or in extended loops rooted against the active core fields. Thus, the strong heating occurs in field configurations consistent with the heating being driven by frequent core-field explosions that are smaller but similar to those in confined flares and flaring arches. From analysis of the thermal and magnetic energetics of two selected core-field microflares and a bright extended loop, we find that (1) it is energetically feasible for the sheared core fields to drive all of the coronal heating in the active region via a staccato of magnetic microexplosions, (2) the microflares at the feet of the extended loop behave as the flares at the feet of flaring arches in that more coronal heating is driven within the active bipole than in the extended loop, (3) the filling factor of the X-ray plasma in the core field microflares and in the extended loop is approximately 0.1, and (4) to release enough magnetic energy for a typical microflare (10^27 - 10^28 erg), a microflaring strand of sheared core field need expand and/or untwist by only a few percent at most. Finally, we point out that (1) the field configurations for strong coronal heating in our example active region (i.e., neutral-line core fields, many embedded in the feet of extended loops) are present in abundance in the magnetic network in quiet regions and coronal holes, and (2) it is known that many network bipoles do microflare and that many produce detectable coronal heating. We therefore propose that exploding sheared core fields are the drivers of most of the heating and dynamics of the solar atmosphere, ranging from the largest and most powerful coronal mass ejections and flares, to the vigorous microflaring and coronal heating in active regions, to the multitude of fine-scale explosive events in the magnetic network. The low-lysing exploding core fields in the network drive microflares, spicules, global coronal heating, and ,consequently, the solar wind.

Moore, Ronald L.↗

An Overview of Liquid Fluoride Salt Heat Transport Systems

Heat transport is central to all thermal-based forms of electricity generation. The ever increasing demand for higher thermal efficiency necessitates power generation cycles transitioning to progressively higher temperatures. Similarly, the desire to provide direct thermal coupling between heat sources and higher temperature chemical processes provides the underlying incentive to move toward higher temperature heat transfer loops. As the system temperature rises, the available materials and technology choices become progressively more limited. Superficially, fluoride salts at {approx}700 C resemble water at room temperature being optically transparent and having similar heat capacity, roughly three times the viscosity, and about twice the density. Fluoride salts are a leading candidate heat-transport material at high temperatures. Fluoride salts have been extensively used in specialized industrial processes for decades, yet they have not entered widespread deployment for general heat transport purposes. This report does not provide an exhaustive screening of potential heat transfer media and other high temperature liquids such as alkali metal carbonate eutectics or chloride salts may have economic or technological advantages. A particular advantage of fluoride salts is that the technology for their use is relatively mature as they were extensively studied during the 1940s-1970s as part of the U.S. Atomic Energy Commission's program to develop molten salt reactors (MSRs). However, the instrumentation, components, and practices for use of fluoride salts are not yet developed sufficiently for commercial implementation. This report provides an overview of the current understanding of the technologies involved in liquid salt heat transport (LSHT) along with providing references to the more detailed primary information resources. Much of the information presented here derives from the earlier MSR program. However, technology has evolved over the intervening years, and this report also describes more recently developed technologies such as dry gas seals. This report also provides a high-level, parametric evaluation of LSHT loop performance to allow general intercomparisons between heat-transport fluid options as well as provide an overview of the properties and requirements for a representative loop. A compilation of relevant thermophysical properties of useful fluoride salts is also included for salt heat transport systems. Fluoride salts can be highly corrosive depending on the container materials selected, the salt chemistry, and the operating procedures used. The report includes an overview of the state-of-the-art in reduction-oxidation chemistry control methodologies employed to minimize corrosion issues. Salt chemistry control technology, however, remains at too low a level of understanding for widespread industrial usage. Loop operational issues such as start-up procedures and system freeze-up vulnerability are also discussed. Liquid fluoride salts are a leading candidate heat transport medium for high-temperature applications. This report provides an overview of the current status of liquid salt heat transport technology. The report includes a high-level, parametric evaluation of liquid fluoride salt heat transport loop performance to allow intercomparisons between heat-transport fluid options as well as providing an overview of the properties and requirements for a representative loop. Much of the information presented here derives from the earlier molten salt reactor program and a significant advantage of fluoride salts, as high temperature heat transport media is their consequent relative technological maturity. The report also includes a compilation of relevant thermophysical properties of useful heat transport fluoride salts. Fluoride salts are both thermally stable and with proper chemistry control can be relatively chemically inert. Fluoride salts can, however, be highly corrosive depending on the container materials selected, the salt chemistry, and the operating procedures used. The report also provides an overview of the state-of-the-art in reduction-oxidation chemistry control methodologies employed to minimize salt corrosion as well as providing a general discussion of heat transfer loop operational issues such as start-up procedures and freeze-up vulnerability.

heat transfer↗

Enabling residential heating decarbonization through hydronic low-temperature thermal distribution using forced-air assistive devices

Space heating represents approximately one-tenth of the United States’ energy use and has a breadth of potential for emission reduction. An element of space heating, hydronic heat distribution methods, use water supply temperatures up to 82.2 °C (180 °F). However, this operating temperature can be incompatible with high-efficiency heat generation systems, which typically provide heating temperatures of up to 60 °C (140 °F). In this work, a low-cost retrofit solution is developed using experimentally validated computational tools by incorporating an airflow distributor that preferentially directs the airflow from a fan to enhance heat transfer over the finned-tube heat exchanger found in conventional baseboards. The same heat output of traditional baseboard heat distribution systems operating at higher water supply temperatures (71.1 – 82.2 °C) can also be achieved at lower temperatures (≤60 °C). Specifically, results indicate that the technology can produce more than a 46.7% improvement in the heat transfer output at temperatures as low as 60 °C (140 °F), effectively matching the same output range achieved by 71.1 – 82.2 °C (160–180 °F) water supply temperatures. An important benefit of this solution is that it utilizes the existing infrastructure as opposed to requiring the replacement of the entire distribution system. Additionally, this technology enables existing building infrastructure to be coupled with newer, high-efficiency heating systems such as condensing boilers, solar-thermal systems, and geothermal/air-to-water heat pumps that may produce lower water supply temperatures (60 °C). A geospatially resolved techno-economic and environmental analysis is completed and presented to further understand the equivalent carbon footprint of enabling higher efficiency heat generation systems with the improved efficiency heat distribution system disclosed. Using 2021 grid-average emission factors, an emission reduction of up to a 67.5% decrease (2658 kgCO 2 /yr) for a single-family home, depending on state and climate region, could be realized by replacing a traditional natural gas-fired boiler with an air-to-water heat pump coupled to the same high-temperature heat distribution system along with the low-cost retrofit solution. A complete CO 2 emission reduction of 6688 kgCO 2 /yr, depending on state and climate region, could be realized if all electricity is further renewably sourced. Thus, this study provides a possible pathway towards enabling the reduction of operational emissions in space heating.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Importance of the Heat Treatment Scheme on Self-Reducing Reactive Silver Inks

Self-reducing reactive silver inks can print high-quality silver at reasonable temperatures. While numerous studies have explored the impact of processing temperature on electrical properties, the role of the heat treatment scheme has not yet been studied. Common heat treatment schemes include printing and drying inks at room temperature before heat treatment, performing heat treatments while the inks are still wet, and directly printing the inks onto heated substrates. Each scheme generates distinct heat transfer and mass transport kinetics that can affect the silver morphology and electrical properties. However, to date, the impact of different schemes has not been systematically investigated. To address this knowledge gap, this work investigates how different heat treatment schemes impact metal formation, sintering, and the resultant electrical properties of printed self-reducing reactive silver inks. Heat treatment on room-temperature dried inks and wet inks, with top-down (oven) and bottom-up (hot plate) heating sources, were compared. Inks dried at room temperature resulted in extremely porous films that required high heat treatment temperatures (>100 °C) for silver densification. However, these dried films could only densify locally, and their high initial porosities resulted in voids and high resistances (~0.6 Ω mm –1 ) even after heat treatments above 300 °C. Inks that were wet during heat treatment showed moderate improvements in electrical properties with resistances on the order of 0.4 Ω mm –1 at heat treatments of 250 °C. Printing reactive inks directly onto heated substrates yielded the best low-temperature results, with 0.46 Ω mm –1 (5.5 × bulk silver) line resistances achieved at only 90 °C. Overall, this work’s experimental results provide detailed insights into why printing onto a heated substrate results in superior electrical performance compared to more common heat treatment schemes. Additionally, controlling where the precipitation reaction occurs is critical to controlling the film morphology and properties. As a result, this work shows that even an ammonia-based silver reactive ink can achieve good, low-temperature electrical properties with the proper heat treatment scheme.

14 SOLAR ENERGY↗

High temperature ceramic heat exchanger for solid oxide fuel cell

A ceramic heat exchanger with high effectiveness and low-pressure drop has been developed for application as a cathode air preheater for a Solid Oxide Fuel Cell (SOFC). At the operating conditions of SOFCs, typical metallic alloys as those used in commercial heat exchangers may undergo chromium volatilization, which is a known cathode degradation mechanism that reduces SOFC performance and life. Use of ceramics such as alumina or alumina-silicate instead of chromium-containing metal is one approach to eliminate the effects of chromium on the SOFC cathode. This project leverages the geometric design of a heat exchanger previously prototyped and tested [1] to fabricate a novel heat exchanger made from a ceramic material. All calculations of heat exchanger performance requirements are based on state of the art SOFC operating conditions. The alumina-silicate material selected to fabricate the modular prototype heat exchanger was made via a heat transfer based trade-off analysis that shows that for low pressure-drop devices, flow convection is the limiting heat transfer mechanism, and therefore wall conductivity becomes less relevant to heat transfer effectiveness. The modular design presented allows for incremental aggregation of modules to target a broad range of operating conditions typical of present and upcoming SOFC applications (e.g., 25 to 400 kWe). The completed prototype was subjected to a series of static leak/pressure tests, dynamic pressure drop tests both at ambient and realistic service temperature conditions, and finally to a matrix of heat transfer experiments to fully characterize its heat transfer effectiveness (including tests at hot gas temperatures up to 1033 K or 1400oF). The stand-alone system was demonstrated in the laboratory to successfully satisfy the design criteria at realistic operating conditions, showing a total pressure drop at the design flow of 8 g/sec of 6 kPa (vs. 3.45 kPa approximate requirement). It was also shown to have heat transfer effectiveness of 76% (with 73% being the design requirement). Moreover, the unit was shown to operate leak-free, and the ceramic elements and seals were capable of withstanding the thermal cycling resulting from the testing procedure. The heat exchanger was then integrated into a modified fuel cell test stand and tested at steady state operation. Unfortunately, the level of performance achieved was lower than expected based on laboratory performance tests. This appears to have been the result of an unforeseen loosening of a heat exchanger structural component, which resulted into a leak that prevented proper supply of hot gas to the heat exchanger. However, in general terms, the heat exchanger/fuel cell integration process provides confidence that a future application of the unit with a SOFC is feasible, assuming structural issues are addressed. It is considered that the difficulties encountered at the last stage of the program provided invaluable input in locating shortcomings of the mechanical design and integration approach. A portion of this work was presented at the ASME Power & Energy Conference, in Charlotte, NC, on June 28th 2016 in a paper entitled “Development of a Ceramic Heat Exchanger for Application as Solid Oxide Fuel Cell Cathode Air Preheater” and the corresponding paper was published in the Proceedings of the ASME 2016 Power & Energy Conference, Paper No.: PowerEnergy2016-59333 [8].

20 FOSSIL-FUELED POWER PLANTS↗

Field Validation of Air-Source Heat Pumps for Cold Climates

Heating energy is the largest end-use for U.S. residential buildings accounting for approximately one-third of residential building energy consumption (EIA 2021). Historically, air-source heat pumps have been limited to temperate climates because of subpar performance at extremely cold outdoor air temperatures. However, recent advances to cold-climate air-source heat pump technology, which typically rely on inverter-driven, variable-speed compressors and variable-speed fans, have significantly improved low-temperature heat pump performance enabling the technology to save energy for many homes in cold climates. The primary objective of this project was to measure in-field performance of centrally ducted, variable-capacity air-source heat pumps in cold climates to validate performance and develop field-based performance maps. The project focused on quantifying heat pump performance at cold temperatures. The sites identified for the study were primarily located in the Northwest United States since homes in the region tend to have all-electric space heating systems and high-efficiency heat pumps have been incentivized in the region for several years. NREL partnered with Ecotope, Inc., a small energy consulting firm located in Seattle, WA, for site recruitment, monitoring equipment installation, data quality management. All the sites included in the study had previously installed a high-efficiency, central heat pump system. One site was in a Denver, CO suburb, which was the only dual fuel heat pump in the study. We used airside and power measurements, collected at 5-second intervals, to quantify heat pump capacity, coefficient of performance (COP), and auxiliary heater energy consumption. We developed algorithms to automatically determine the heat pump operating mode including defrost and auxiliary heating operation. A whole-house thermal and duct audit was completed during the initial site visit to estimate winter heating loads and assess heat pump sizing. Whole-home heating design loads were calculated at ASHRAE 99% design temperatures and compared to manufacturer-reported maximum capacities to assess the heat pump sizing at each site.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Documentation: Heat Pump Rooftop Units with Standard Performance

This documentation focuses on a single end-use savings shape measure - heat pump rooftop units (HP-RTUs) with standard efficiencies that are prevalent in the current market. Today, these products are claimed as standard efficiency by the manufacturers and are most commonly installed. This document will primarily discuss the additional changes of performance and configuration of the standard efficiency HP-RTUs while a comprehensive overview of the fundamental modeling methodology and background of the HP-RTU measure, including applicability, sizing scheme, and other key assumptions can be found in the original documentation: Heat Pump RTU. The definition of "standard efficiency" can be a bit vague when considering detailed specifics other than efficiency metrics of a heat pump. Thus, we have focused on reflecting products where manufacturers claim as standard efficiency and products that are not top-of-the-line in their model lineup. Based on gathering information from eight products from four major manufacturers, there are some common (or relatively prevalent) characteristics and we have defined standard efficiency product as follows: direct drive outdoor unit fan, two stages of heat pump cooling, single stage heat pump heating (i.e., all compressors running at the same time), heat pump minimum lockout temperature of 0°F (-17.8°C), backup electric resistance heating, backup heating runs at the same time as heat pump heating , heat pump heating locking out below minimum operating temperature, IEER in between 11-13, and HSPF in between 8-8.9. There are cases where some of these products have other variations: a variable frequency drive fan, dual fuel (i.e., gas backup heating) option, three or more cooling stages, two stages of heat pump heating, no backup heating as default , etc. However, this work tried to reflect the most common and prevalent options for a standard efficiency product.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling and analysis of heat emissions from buildings to ambient air

Heat emissions from buildings is a significant source of anthropogenic heat influencing the urban microclimate; however, they are usually oversimplified in urban climate and microclimate modeling. This study developed a bottom-up physics-based approach to calculate heat emissions from buildings to the ambient air and implemented the approach in EnergyPlus. In this work, a simple result verification was conducted by comparing the EnergyPlus simulated results against the spreadsheet calculations. Simulations covering 16 commercial building types, four climates, and two energy efficiency levels were conducted to understand and evaluate the building heat emissions and their temporal patterns as well as three major components: (1) building envelope (convective heat transfer to ambient air), (2) zones (air exfiltration and exhaust air), and (3) HVAC systems (relief air and heat rejection from condensers or cooling towers). The main findings are: (1) heat emissions are usually higher than the site energy use (about 2.5 times), and their dynamics should be considered; (2) building characteristics and their energy systems lead to differences in heat emission contributions from the three components, and their dynamics, for example, in the warehouse models, the envelope component accounts for 90.4%, while it is 12.7% for the large office models; (3) for most building typologies, the climate has a strong impact on heat emissions, for example, buildings with dominant heat emissions from the zone exhaust air and/or the HVAC reject heat, a general decrease in heat emissions in hotter climates is observed, while envelope-dominated buildings show the opposite; and (4) building technologies that reduce energy use in buildings may perform differently in reducing heat emissions. The developed heat emissions calculation method can be adopted in EnergyPlus and most other building energy modeling programs. It can provide dynamic building heat emissions as an input to urban climate computational fluid dynamics (CFD) models at a higher spatial and temporal resolution than is currently available, to improve the simulation accuracy of the urban microclimate and capture the urban heat island effect and urban overheating.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and field demonstration of residential air source integrated heat pump using a three-stage compressor

To promote decarbonization and all electrification at residential sectors, it is necessary to use air source heat pumps (ASHPs) to replace natural gas for space heating and water heating. ASHPs are widely utilized for residential space cooling, heating, and water heating due to their simplicity and cost-effectiveness. However, their performance can be compromised in cold climates, where they may experience reduced heating capacity. A multi-functional heat pump, using a single compressor, to meet all home space conditioning and water heating demands, is an emerging technology. To address this limitation, we have developed and demonstrated an air source integrated heat pump to fulfill comprehensive home comfort requirements. This system employs a three-stage compressor and a single set of heat exchangers and valves, optimizing functionality while minimizing costs. The performance of the developed system was rigorously evaluated in both laboratory and field settings. In laboratory conditions, the system achieved a Seasonal Energy Efficiency Ratio of 17.0 (average COP of 4.98) and a Heating Seasonal Performance Factor of 11.0 (3.22). Additionally, in its most efficient operational mode—combining space cooling and water heating—the unit attained a total energy efficiency exceeding 7.0 seasonal COP in the field and could heat a 189-liter tank of water in just 25 min. The field study corroborated the laboratory findings, validating the system’s performance in real-world conditions. Here, this integrated heat pump represents an ideal solution for decarbonizing homes in northern climates by providing efficient space heating and water heating, thereby replacing the need for natural gas.

Integrated heat pump↗

Theoretical Design of Thermosyphon for Process Heat Transfer from NGNP to Hydrogen Plant

The Next Generation Nuclear Plant (NGNP) will most likely produce electricity and process heat, with both being considered for hydrogen production. To capture nuclear process heat, and transport it to a distant industrial facility requires a high temperature system of heat exchangers, pumps and/or compressors. The heat transfer system is particularly challenging not only due to the elevated temperatures (up to ~ 1300K) and industrial scale power transport (=50 MW), but also due to a potentially large separation distance between the nuclear and industrial plants (100+m) dictated by safety and licensing mandates. The work reported here is the preliminary analysis of two-phase thermosyphon heat transfer performance with alkali metals. A thermosyphon is a device for transporting heat from one point to another with quite extraordinary properties. In contrast to single-phased forced convective heat transfer via ‘pumping a fluid’, a thermosyphon (also called a wickless heat pipe) transfers heat through the vaporization / condensing process. The condensate is further returned to the hot source by gravity, i.e. without any requirement of pumps or compressors. With this mode of heat transfer, the thermosyphon has the capability to transport heat at high rates over appreciable distances, virtually isothermally and without any requirement for external pumping devices. Two-phase heat transfer by a thermosyphon has the advantage of high enthalpy transport that includes the sensible heat of the liquid, the latent heat of vaporization, and vapor superheat. In contrast, single-phase forced convection transports only the sensible heat of the fluid. Additionally, vapor-phase velocities within a thermosyphon are much greater than single-phase liquid velocities within a forced convective loop. Thermosyphon performance can be limited by the sonic limit (choking) or vapor flow and/or by condensate entrainment. Proper thermosyphon requires analysis of both.

08 HYDROGEN↗

Experimental study of heating scheme effect on the inner divertor power footprint widths in EAST lower single null discharges

A comprehensive work of the effects of plasma current and heating schemes on divertor power footprint widths is carried out in the experimental advanced superconducting tokamak (EAST). The divertor power footprint widths, i.e., the scrape-off layer heat flux decay length λ q and the heat spreading S, are crucial physical and engineering parameters for fusion reactors. Strong inverse scaling of λ q and S with plasma current have been demonstrated for both neutral beam (NB) and lower hybrid wave (LHW) heated L-mode and H-mode plasmas at the inner divertor target. For plasmas heated by the combination of the two kinds of auxiliary heating schemes (NB and LHW), the divertor power widths tend to be larger in plasmas with higher ratio of LHW power. Comparison between experimental heat flux profiles at outer mid-plane (OMP) and divertor target for NB heated and LHW heated L-mode plasmas reveals that the magnetic topology changes induced by LHW may be the main reason to the wider divertor power widths in LHW heated discharges. The effect of heating schemes on divertor peak heat flux has also been investigated, and it is found that LHW heated discharges tend to have a lower divertor peak heat flux compared with NB heated discharges under similar input power. All these findings seem to suggest that plasmas with LHW auxiliary heating scheme are better heat exhaust scenarios for fusion reactors and should be the priorities for the design of next-step fusion reactors like China Fusion Engineering Test Reactor.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Failures and Implications of Heat Pipe Systems

Under Department of Energy (DOE), Office of Nuclear Energy (NE), Gateway for Accelerated Innovation in Nuclear (GAIN), Sandia National Laboratories (SNL) was awarded DOE-NE GAIN voucher GA-19SN020107, "Risk-informed mechanistic source term calculations for a sodium fast reactor." Under this GAIN voucher, SNL supported the industry partners development in preparation for licensing and commercialization by providing subject matter expertise on heat pipe technologies, providing computer code training and support, and perform first-of-a-kind experiments demonstrating the safety/risk impacts of heat pipe breach failures. The experiments that were performed had two primary goals: measure the peak heat fluxes that lead to heat pipe dry out and subsequent wall breach; and observe the consequences that result from catastrophic failure of a heat pipe wall. Intentional breaching of the heat pipe walls took advantage of heat pipe physics and operating limits. Large and nearly instantaneous heat fluxes were applied to the heat pipe to first cause localized dry out at the evaporator section which then leads to melting of the heat pipe wall. The hour glass heat pipe (Test 1) experienced dry out at 112 W/cm 2 and after 45 seconds, wall temperatures measure about 1,280°C and intentional failure of the heat pipe wall was achieved. The cylindrical heat pipe (Test 2) experienced dry out at 125 W/cm 2 and after 65 seconds, wall temperatures exceeded 1,400°C and intentional failure of the heat pipe wall was achieved. Both experiments characterize the parameters needed to lead to heat pipe wall failure. Furthermore, the failure of the heat pipes characterizes the safety/risk impacts from sodium-oxygen reactions that occur following the intentional failure. There were two major conclusions of these intentional failure tests: the heat pipes were able to continue operating beyond expected performance limits, and the failure behavior validated decades of operational experience.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermion: Verification of a thermionic heat pipe in microgravity

The Idaho National Engineering Laboratory (INEL) is conducting intensive research in the design and development of a small excore heat-pipe-thermionic space nuclear reactor power system (SEHPTR). The SEHPTR spacecraft will be able to supply 40 kW of power in any given orbit. The key components in this reactor are the thermionic heat pipes. The heat pipes have two major functions: (1) to convert heat energy into electrical energy, and (2) to radiate the excess heat to space. Thermionic power conversion is the process of converting heat energy into electrical energy with no moving parts. Heat is applied to the cathode surface. This heat will boil off electrons that will jump across the gap to the cooler surface of the anode, which will cause a potential difference between the two plates and induce a current through the load. Thermionic power conversion is incorporated as part of the heat pipe. The heat pipe, which is being developed by Thermacore Inc., is actually two heat pipes. It uses a radial heat pipe, called the emitter, and an axial heat pipe collector. The emitter heat pipe will pass the heat from the nuclear core to the cathode surface. The collector heat pipe keeps the anode surface cooler by transferring the heat from the anode surface and radiating it to space.