At least 1,297 records · Page 72

Puerto Rico Grid and Recovery Post Hurricane Maria

This presentation discusses the impact of and recovery from Hurricanes Irma and Maria in Puerto Rico. The hurricanes hit two weeks apart in 2017, resulting in damage to all elements (generation, distribution, and transmission) of Puerto Rico's already fragile energy system.

demand response↗

A Data-Driven Approach for High-Impedance Fault Localization in Distribution Systems: Preprint

Accurate and quick identification of high-impedance faults (HIFs) is critical for the reliable operation of distribution systems. Unlike other faults in power grids, HIFs are very difficult to detect by conventional overcurrent relays due to the low fault current. Although HIFs can be affected by various factors, the voltage-current characteristics can substantially imply how the system responds to the disturbance and thus provides opportunities to effectively localize HIFs. In this work, we propose a data-driven approach for the identification of HIF events. To tackle the nonlinearity of the voltage-current trajectory, first, we formulate optimization problems to approximate the trajectory with piecewise functions. Then we collect the function features of all segments as inputs and use the support vector machine approach to efficiently identify HIFs at different locations. Numerical studies on the IEEE 123-node test feeder demonstrate the validity and accuracy of the proposed approach for real-time HIF identification.

explainable artificial intelligence↗

Scaling Demand Flexibility: Building on 30 Years of Energy Efficiency Success

With electricity consumption across the United States (US) and Canada anticipated to grow, energy efficiency program administrators have a key role to play in helping to ensure energy affordability and reliability in support of the broader economic systems utilities and grid support. Connected, demand side load balancing solutions, such as load shifting heating, ventilation and air conditioning (HVAC) systems and managed charging for electric vehicles (EVs), can dynamically manage energy, allowing for more volumetric electricity consumption without incurring the expense of upgraded transmission and distribution capabilities. When combined, or aggregated, many small loads can be managed to have meaningful impact on energy demand on the grid. Utilities and their partners have an opportunity to leverage decades of experience and the infrastructure needed to assess, design, implement, and measure programs to scale up the adoption of equipment with built-in load flexibility capabilities. Current efforts among a wide variety of electricity system service providers, utilities, standards agencies, regulators, national labs and private industry stakeholders aim to identify common standards, metrics, and methodologies for valuing grid services offered by demand side equipment. By combining those efforts with decades of proven energy efficiency resources, utilities are poised to effectuate a scaling up of equipment with energy management capabilities installed in homes and businesses across the US and Canada. This paper will provide an overview of how utilities are approaching this era of load growth and new peak demands across the United States and Canada. It will highlight the specific strategies that program administrators are employing to advance market transformation for grid-enabled products and devices that have the greatest potential to reduce energy use and increase load flexibility.

Grant, Peter↗

Medium Voltage Testbed for Comparing Advanced Power Line Sensors vs. Transformers with Electrical Grid Events

Electrical utilities have relied upon potential transformers (PTs) and current transformers (CTs) for very accurate metering and to provide reliable signals for protective relays. These devices measure phase voltages and currents and are commissioned by electrical engineers. PTs/CTs can detect and react to various electrical anomalies that could adversely affect electrical grid operations. Less expensive alternative sensing technologies offer the possibility of wider deployment, particularly in grids that employ distributed energy resources. In this work, the performance of an advanced medium-voltage sensor is compared with that of a reference PT and a CT and experimentally evaluated for different power grid scenarios on an advanced outdoor power line sensor testbed at the U.S. Department of Energy’s Oak Ridge National Laboratory. The sensor is based on a capacitive divider for voltage monitoring and a Rogowski coil with an integrator for current monitoring. This study simulated a power grid model based on a utility circuit at the Riverside EPB of Chattanooga. The simulation circuit was created with MATLAB/Simulink software and was integrated into an RT-LAB project to run with the OP4510 real-time simulator at the OPLST. During the tests, the real-time simulations were run for 40 s, and the signal to record the test event with the power meter was set at 30 s for the event-trigger circuit. The advanced outdoor power line sensor testbed has a real-time simulator that is used to generate transient scenarios (e.g., electrical faults, capacitor bank operation, and service restoration), while the analog signals are recorded by the same high-resolution power meter. The behaviors of analog signals, harmonic components, total harmonic distortion, and crest factors are assessed for this power line sensor and compared with those of the reference PT/CT because of the absence of testing standards for advanced outdoor power line sensors. The results showed that this OPLS technology responded identically to the PT and CT under all conditions.

Piesciorovsky, Emilio [ORNL]↗

Production of hydrogen driven from biomass waste to power Remote areas away from the electric grid utilizing fuel cells and internal combustion engines vehicles

Recent concerns over the security and reliability of the world’s energy supply has caused a flux towards the research and development of renewable sources. A leading renewable source has been found in the biomass gasification of biological materials derived from organic matters such as wood chips, forest debris, and farm waste that are found in abundance in the USA. Accordingly, there is a very strong interest worldwide in the development of new technologies that provide an in-depth understanding of this economically viable energy source. This work aims to allow the coupling of biomass gasification and fuel cell systems as well as Internal Combustion Engines (ICE) to produce high-energy efficiency, clean environmental performance and near-zero greenhouse gas emissions. Biomass gasification is a process, which produces synthesis gas (syngas) that contains 19% hydrogen and 20% carbon monoxide from inexpensive organic matter waste. This project main goal is to provide cost effective energy to the public utilizing remote farms’ waste and landfill recycling area.

08 HYDROGEN↗

Optimal Operation for Resilient and Economic Modes in an Islanded Alaskan Grid: Preprint

Power System is a complex system, with an objective to provide power to the customers. The objective is driven by a complex consideration of the secure, economic and resilient operation of the system. With the growing occurrence of extreme events emphasis has been shifted towards making the grid more resilient. However, an economic operation is still a priority for the utilities as well as its customers. Many utilities especially small isolated micro-grids do not emphasize much on an economic and resilient operation, but more on reliability. In this research we focus on striking a balance between economic and resilientoperation, ensuring reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Guidance for Grid Resilience Decisions in Rural Minnesota

This report assesses the hazard landscape of the state of Minnesota, identifies weather hazards that are most impactful to the distribution system, includes a statewide assessment of household access to services dependent on reliable power, reviews resilience planning activities of electric utilities in Minnesota, and presents analysis of distribution grid performance in the face of extreme weather events with data from seven electric cooperatives dispersed throughout outstate Minnesota. This information is synthesized to provide considerations for resilience investment prioritization.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Natural Hazard Forecast Alert Grid Risk System

Weather events cause most power outages. Often, we even get notifications on our phones to take cover or be prepared for an imminent event. If electric grid utilities had a similar warning that also included probable scenarios and the equipment involved, they could prepare and minimize the effects. Idaho National Laboratory had a project with the U.S. Department of Energy’s Cybersecurity, Energy Security, and Emergency Response program to develop a grid alert application that receives messages from the existing emergency alert system, filters and determines components possibly affected by the emergency event, calculates probable scenarios using MASTERRI (Modeling And Simulation for Targeted Reliability and Resilience Improvement). For high-risk events, the application can then send alert links to subscribed electric distribution utility operations staff to allow them to see and evaluate the scenarios and the impact in a web based interactive map tool. This proof of concept application used data from utilities and organizations, such as the international regulatory body North American Electric Reliability Corporation, which have complied historical failure data of elements that comprise the U.S. electric grid. Nominal failure rates are obtained from this data. To make this tool possible, estimated failure rates were calculated for different component types given the alert type, severity, and location. Historic weather-related grid element failures were correlated with historic weather events from the Integrated Public Alert & Warning System. These correlated events and failures are used along with Bayesian updates from the historical norms to provide a modified failure rate for grid elements in the alert areas and calculate probable scenarios. Working with an industry collaborator, actual grid models and data were used for demonstration cases. This report outlines the work performed for this project.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Data-Driven Probabilistic Anomaly Detection for Electricity Market under Cyber Attacks

Information and communication technologies have been widely used in smart grid for efficient operation. However, these technologies are vulnerable to malicious cyber attacks, which may lead to severe reliability and economic issues. Recently, a variety of data-driven anomaly detection approaches have been explored to detect potential cyber attacks in smart grids. In this paper, we researched on the electricity market data aiming to identify anomalies from the locational marginal prices (LMPs) and provide a new indicator for potential cyber attacks in power grids. Specifically, a novel data-driven probabilistic anomaly detection framework is proposed for electricity market, which consists of three major components: long short-term memory (LSTM) based deterministic electricity price forecasting, probabilistic electricity price forecasting and anomaly detection. This framework is tested on a model-based electricity market simulator under two types of cyber attacks, i.e., load redistribution attack (LRA) and price responsive attack (PRA). Numerical results on the simulated LMPs show that the proposed framework is capable of detecting data anomalies over these attacks.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Flywheel Energy Storage - Dynamic Modeling

A flywheel energy storage systems (FESS) is suitable for high-power, low-energy content to deliver or absorb power in surges. This type of application is very suitable for frequency regulation in an electric grid. In addition, a modern FESS is built as a high-efficiency, high-speed motor/generator drive system that employs modern power electronics, therefore, the power quality of the grid-connected output is excellent. In addition, a FESS is very valuable to delivering ancillary services to the grid, and it can contribute reactive power compensation. Thus, a FESS can maintain high reliability in power systems by providing ride-through capability to the power system area while the rest of the generating fleet, which has a slower response in the power system, performs primary and secondary frequency response to the grid. A FESS has several advantages compared to a chemical-based energy storage (CBES) system, namely: it has high energy density and durability, and it can be cycled frequently without impacting performance. The response of FESS is faster than that of a CBES. Also, unlike some CBES, FESS has the same performance regardless of the number of cycles of charging/discharging performed throughout its lifetime.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Interconnecting PV on New York City's Secondary Network Distribution System

The U.S. Department of Energy (DOE) has teamed with cities across the country through the Solar America Cities (SAC) partnership program to help reduce barriers and accelerate implementation of solar energy. The New York City SAC team is a partnership between the City University of New York (CUNY), the New York City Mayor s Office of Long-term Planning and Sustainability, and the New York City Economic Development Corporation (NYCEDC).The New York City SAC team is working with DOE s National Renewable Energy Laboratory (NREL) and Con Edison, the local utility, to develop a roadmap for photovoltaic (PV) installations in the five boroughs. The city set a goal to increase its installed PV capacity from1.1 MW in 2005 to 8.1 MW by 2015 (the maximum allowed in 2005). A key barrier to reaching this goal, however, is the complexity of the interconnection process with the local utility. Unique challenges are associated with connecting distributed PV systems to secondary network distribution systems (simplified to networks in this report). Although most areas of the country use simpler radial distribution systems to distribute electricity, larger metropolitan areas like New York City typically use networks to increase reliability in large load centers. Unlike the radial distribution system, where each customer receives power through a single line, a network uses a grid of interconnected lines to deliver power to each customer through several parallel circuits and sources. This redundancy improves reliability, but it also requires more complicated coordination and protection schemes that can be disrupted by energy exported from distributed PV systems. Currently, Con Edison studies each potential PV system in New York City to evaluate the system s impact on the network, but this is time consuming for utility engineers and may delay the customer s project or add cost for larger installations. City leaders would like to streamline this process to facilitate faster, simpler, and less expensive distributed PV system interconnections. To assess ways to improve the interconnection process, NREL conducted a four-part study with support from DOE. The NREL team then compiled the final reports from each study into this report. In Section 1 -- PV Deployment Analysis for New York City -- we analyze the technical potential for rooftop PV systems in the city. This analysis evaluates potential PV power production in ten Con Edison networks of various locations and building densities (ranging from high density apartments to lower density single family homes). Next, we compare the potential power production to network loads to determine where and when PV generation is most likely to exceed network load and disrupt network protection schemes. The results of this analysis may assist Con Edison in evaluating future PV interconnection applications and in planning future network protection system upgrades. This analysis may also assist other utilities interconnecting PV systems to networks by defining a method for assessing the technical potential of PV in the network and its impact on network loads. Section 2. A Briefing for Policy Makers on Connecting PV to a Network Grid presents an overview intended for nontechnical stakeholders. This section describes the issues associated with interconnecting PV systems to networks, along with possible solutions. Section 3. Technical Review of Concerns and Solutions to PV Interconnection in New York City summarizes common concerns of utility engineers and network experts about interconnecting PV systems to secondary networks. This section also contains detailed descriptions of nine solutions, including advantages and disadvantages, potential impacts, and road maps for deployment. Section 4. Utility Application Process Review -- looks at utility interconnection application processes across the country and identifies administrative best practices for efficient PV interconnection.

14 SOLAR ENERGY↗

Assessing the energy equity benefits of energy storage solutions

Safety, reliability, efficiency, and affordability are no longer the sole tenets of electric grid planning. The evolving social and policy climate have placed new explicit requirements on the electric grid, including resilience, decarbonization, and energy equity and justice. Integrating energy equity strategies into modern grid design is intended to achieve a fair and just distribution of benefits within the energy system. This study aims to characterize the energy equity and community benefits of energy storage systems (ESS) under the following three use-case models: utility ESS that are operated within the distribution system; community-owned ESS; and behind-the-meter ESS that are customer-owned to serve the household. The goal of this energy equity analysis is to characterize the environmental, economic, and social benefits of ESS through applied metrics such as energy burden, energy poverty, energy vulnerability, job creation, and more. A 13.8 kV, 265 node representative feeder corresponding to the hot-humid climate of Louisiana, chosen for its high energy burden, frequent hurricanes and outage events, was used to perform a storage adequacy analysis for six different outage scenarios to determine energy storage access for each use-case. The results of this analysis are then used to characterize both the grid and equity benefits of storage solutions to inform a prioritization framework matching community needs with system preferences for utility planning processes, market regulations, and the wider network of energy system stakeholders.

Energy Equity, energy justice, equity, reliability↗

Integrated multimodel analysis reveals achievable pathways toward reliable, 100% renewable electricity for Los Angeles

Climate change has prompted many communities to set targets for carbon-free power supplies, but they often lack data-driven strategies to achieve them. We present a comprehensive analysis of an entirely renewable electric power system that can maintain operating reliability and resource adequacy using detailed models of the city of Los Angeles power grid. In consultation with the operating utility, the Los Angeles Department of Water and Power (LADWP), and the local community, we develop four supply scenarios across three demand projections to analyze which types of infrastructure and operational changes would achieve reliable electricity at least cost. We find that a reliable, 100%-renewable power system yielding more than $1 billion annually in health and climate co-benefits is achievable. Solar can supply most future energy needs, while combustion turbines that use renewable, storable carbon-neutral fuels are key to maintaining reliability. This study provides a replicable methodology that other jurisdictions globally can follow.

14 SOLAR ENERGY↗

Robust, multidimensional mesh motion based on Monge-Kantorovich equidistribution

Mesh-motion (r-refinement) grid adaptivity schemes are attractive due to their potential to minimize the numerical error for a prescribed number of degrees of freedom. However, a key roadblock to a widespread deployment of this class of techniques has been the formulation of robust, reliable mesh-motion governing principles, which (1) guarantee a solution in multiple dimensions (2D and 3D), (2) avoid grid tangling (or folding of the mesh, whereby edges of a grid cell cross somewhere in the domain), and (3) can be solved effectively and efficiently. In this study, we formulate such a mesh-motion governing principle, based on volume equidistribution via Monge-Kantorovich optimization (MK). In earlier publications [1] and [2], the advantages of this approach with regard to these points have been demonstrated for the time-independent case. In this study, we demonstrate that Monge-Kantorovich equidistribution can in fact be used effectively in a time-stepping context, and delivers an elegant solution to the otherwise pervasive problem of grid tangling in mesh-motion approaches, without resorting to ad hoc time-dependent terms (as in moving-mesh PDEs, or MMPDEs [3] and [4]). We explore two distinct r-refinement implementations of MK: the direct method, where the current mesh relates to an initial, unchanging mesh, and the sequential method, where the current mesh is related to the previous one in time. We demonstrate that the direct approach is superior with regard to mesh distortion and robustness. The properties of the approach are illustrated with a hyperbolic PDE, the advection of a passive scalar, in 2D and 3D. Velocity flow fields with and without flow shear are considered. Three-dimensional grid, time-step, and nonlinear tolerance convergence studies are presented which demonstrate the optimality of the approach.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Driving Zn-MnO2 grid-scale batteries: A roadmap to cost-effective energy storage

Highlights Zn-MnO 2 batteries promise safe, reliable energy storage, and this roadmap outlines a combination of manufacturing strategies and technical innovations that could make this goal achievable. Approaches such as improved efficiency of manufacturing and increasing active material utilization will be important to getting costs as low as $100/kWh, but key materials innovations that facilitate the full 2-electron capacity utilization of MnO 2 , the use of high energy density 3D electrodes, and the promise of a separator-free battery with greater than 2V potential offer a route to batteries at $50/kWh or less. Abstract Large-scale energy storage is certain to play a significant, enabling role in the evolution of the emerging electrical grid. Battery-based storage, while not a dominant form of storage today, has opportunity to expand its utility through safe, reliable, and cost-effective technologies. Here, secondary Zn–MnO 2 batteries are highlighted as a promising extension of ubiquitous primary alkaline batteries, offering a safe, environmentally friendly chemistry in a scalable and practical energy dense technology. Importantly, there is a very realistic pathway to also making such batteries cost-effective at price points of $50/kWh or lower. By examining manufacturing examples at the Zn–MnO 2 battery manufacturer Urban Electric Power, a roadmap has been created to realize such low-cost systems. By focusing on manufacturing optimization through reduced materials waste, scalable manufacturing, and effective materials selection, costs can be significantly reduced. Ultimately, though, coupling these approaches with emerging research and development advances to enable full capacity active materials utilization and battery voltages greater than 2V are likely needed to drive costs below a target of $50/kWh. Reaching this commercially important goal, especially with a chemistry that is safe, well-known, and reliably effective stands to inject Zn–MnO 2 batteries in the storage landscape at a critical time in energy storage development and deployment. Graphical abstract

Spoerke, Erik D. (ORCID:0000000322862560)↗

SIW21-95: Hybridizing Synchronous Condensers with Grid-Forming Battery Energy Storage Systems

One of the main challenges associated with deployment of high shares of inverter-based resources (IBRs) in power grid is not only reduced system inertia but also degrading system strength that may cause severe stability impacts. A minimum level of system strength is needed for the power system to remain stable under normal conditions and to return to a steady state condition following a system disturbance. Significant system strength reduction is expected in almost all planned areas for solar and wind generation deployment. Synchronous condensers (SC) have been considered as one main technology to address the system strength issues for the areas with high levels of IBRs. SCs can help improving reliability and resiliency of power system but they do not provide the full range of services needed by power systems for reliable and economic integration of high shares of inverter-coupled variable generation such as PV generation. Services related to active power controls cannot be provided by SCs due to lack of prime mover. Even for provision of reactive power SCs have certain constraints based on their thermal and stability limits. NREL has been conducting research on a hybridized concept that combines SCs with grid forming (GFM) battery energy storage systems (BESS). This super flexible AC transmission system (SuperFACTS) that combines these two technologies in a single plant under the same controller offers a unique scalable set of services to the power system at all levels (transmission, sub-transmission, distribution, islands and isolated microgrids). Depending on use cases, SuperFACTS can be controlled to provide fully dispatchable and flexible operation using energy storage component, provide a full range of existing and future ancillary and reliability services to the grid (similar or better than conventional sources), maintain adequate levels of grid strength and inertia, and provide fault current for proper operation of protection systems. Therefore, this economic and easy to commercialize solution has potential for significant impacts on certain segments of global energy sector. All types of gird services (market based, reliability and resiliency) can be provided by SuperFACTS plants. GFM BESS can act as a self-black start source for each SuperFACTS module, which in turn can act a black start resource for co-located PV and wind power plants, segments of transmission and distribution networks, for conventional power plants, etc. The issue of in-rush currents during black start is addressed by overcurrent capability of SCs. In this paper we describe the results of modeling for SuperFACTS concept.

grid forming↗