Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Grating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

A two-temperature model for the flare of 5 September, 1973

A study of the energetics and mass transfer during the X-ray flare on Sept. 5, 1973, using the observations in the objective grating mode of the spectrographic telescope on Skylab is presented. The data are approximately monochromatic images of a small X-ray source which show a continued rise in the emission for several minutes followed by a decline. The observations are analyzed using a two-temperature model to determine the changes in the distribution of emission measure and of the amount of material as a function of temperature. The development of the flare can be divided into three periods comprising evaporation which drives mass into the entire emitting region, cessation of evaporation, and decline in the emission measure.

Little-Marenin, I. R.↗

Design and operation of the Pioneer Venus Orbiter ultraviolet spectrometer

The University of Colorado's ultraviolet spectrometer instrument carried on the Pioneer Venus Orbiter spacecraft is a 125-mm f/5 Ebert-Fastie design with a 250-mm Cassegrain telescope. The instrument has extensive logic to control the grating motor drive and to adapt the basic spectrometer to the constraints and opportunities of the mission. Success has been achieved in reconciling the conflicting requirements of spectroscopic, limb profile, and imaging observations. A description of the instrument operating techniques is given together with representative results of all three types.

Stewart, A. I. F.↗

Anomalous /C-13/H4:/C-12/H4 line strengths in 2 nu 3

Anomalous intensity ratios between 2 nu 3 singlet lines of C-13 methane and C-12 methane are reported. Absolute strengths of the Q1, R0 and R1 singlets were measured for essentially pure samples of (C-13)H4 and (C-12)H4 at a resolution of 0.035 kaysers at pressures of 10 and 20 Torr, using a computer controlled grating spectrometer. Line strength ratios between the isotopic species are presented which demonstrate a dramatic effect of isotopic substitution on line strengths. If this effect can be observed in the 3 nu 3 vibration-rotation band of methane, which is widely used in planetary atmosphere studies, revision of the (C-12)H4/(C-13)H4 abundance ratios of the outer planets will be necessary.

Fox, K.↗

A search for stellar remnants of supernovae

The slitless spectra of the stars in the central regions of six galactic supernova remnants Cas A, Kepler, Tycho, SN 1006, RCW 86, and the Cygnus Loop were obtained with the prime focus transmission gratings at the 4M telescopes on Kitt Peak and Cerro Tololo. It was found that no stellar remnant with an unusually blue or peculiar spectrum is present in any of the remnants down to the limit of m sub pg of 18.5. Except for the Cygnus Loop, the area searched in each remnant is large enough that objects with transverse velocities of 1000 km/s would be well within the field. The results are also compared with a computation of emission from gas near a neutron star and with the unpulsed emission from the Crab pulsar; in both cases upper limits were set which place constraints on a possible condensed stellar remnant.

Fesen, R. A.↗

Physical properties of individual coronal loops in a solar active region observed in the XUV

The physical properties of individual coronal loops in a solar active region observed in the XUV by the slitless objective grating spectroheliograph on board Skylab are investigated. Spectroheliograms of the normal active loop region McMath 12378 reveal three distinctive structural groups of loops in different temperature ranges, namely (1) small compact and smaller loops at temperatures of about 2,000,000 K observed in Fe XV and Fe XVI; (2) large Ne VII and Mg IX loops at temperatures from 500,000 to 1,000,000 K; and (3) chromospheric ribbons in He II and H alpha. The temperature of the active region is found to be uniform at about 2,000,000 K in the loops and background while loop density is found to be 3.5 x 10 to the 9th/cu cm in the loops and 2.5 x 10 to the 9th/cu cm in the surrounding background. Significant changes in the active region are observed in 24 h, although the gross temperature density structures of many loops do not show changes in 7 min. Gas pressure within the coronal loops is found to be about 40% greater than that of the background plasma. The observed loop parameters are noted to be consistent with flux-limited models of density enhancement in magnetic flux tubes and thus no esoteric heating function is required.

Cheng, C.-C.↗

Echelle efficiencies - Theory and experiment

The effect of one echelle spectrograph design factor, orientation of the incident light bundle, is examined. Comparison of theoretical calculations and experimental measurements of echelle grating efficiencies are given for R2 echelles used in three possible configurations: alpha greater than beta, alpha smaller than beta, and the quasi-Littrow mode. The throughput-resolution products for these various cases are also compared.

Schroeder, D. J.↗

Fast Holographic Comparator

Comparator is integrated-optical system constructed on a LiNb03sub. waveguide chip. Only the laser, lens and detector are external to chip. Aluminized surface gratings serve as input coupler and beam splitter. Light beams striking edges are returned by ordinary total internal reflection. Three operating modes are possible: A "screening" mode, an "identification" mode and a novel "self-subtraction" mode.

Vahey, D. W.↗

System performance conclusions

The advantages and disadvantages of reducing power levels and using antennas with diameters smaller than 1 Km were evaluated if rectenna costs and land usage requirements become major factors, operating at 5800 megahertz should be considered. Three sequences (random, incoherent phasing, and concentric rings - center to edge) provided satisfactory performance in that the resultant sidelobe levels during startup/ shutdown were lower than the steady-state levels present during normal operations. Grating lobe peaks and scattered power levels were used to determine the array/subarray mechanical alignment requirements. The antenna alignment requirement is 1 min or 3 min depending on phase control configuration. System error parameters were defined to minimize scattered microwave power.

Arndt, G. D.↗

An investigation for the development of an integrated optical data preprocessor

A laboratory model of a 16 channel integrated optical data preprocessor was fabricated and tested in response to a need for a device to evaluate the outputs of a set of remote sensors. It does this by accepting the outputs of these sensors, in parallel, as the components of a multidimensional vector descriptive of the data and comparing this vector to one or more reference vectors which are used to classify the data set. The comparison is performed by taking the difference between the signal and reference vectors. The preprocessor is wholly integrated upon the surface of a LiNbO3 single crystal with the exceptions of the source and the detector. He-Ne laser light is coupled in and out of the waveguide by prism couplers. The integrated optical circuit consists of a titanium infused waveguide pattern, electrode structures and grating beam splitters. The waveguide and electrode patterns, by virtue of their complexity, make the vector subtraction device the most complex integrated optical structure fabricated to date.

Verber, C. M.↗

Design study for Thermal Infrared Multispectral Scanner (TIMS)

The feasibility of dividing the 8-12 micrometer thermal infrared wavelength region into six spectral bands by an airborne line scanner system was investigated. By combining an existing scanner design with a 6 band spectrometer, a system for the remote sensing of Earth resources was developed. The elements in the spectrometer include an off axis reflective collimator, a reflective diffraction grating, a triplet germanium imaging lens, a photoconductive mercury cadmium telluride sensor array, and the mechanical assembly to hold these parts and maintain their optical alignment across a broad temperature range. The existing scanner design was modified to accept the new spectrometer and two field filling thermal reference sources.

Stanich, C. G.↗

Liquid-phase epitaxy grown PbSnTe distributed feedback laser diodes with broad continuous single-mode tuning range

Distributed feedback (DFB) pulsed laser operation has been demonstrated in stripe geometry Pb(1-x)Sn(x)Te double-heterostructures grown by liquid-phase epitaxy. The grating structure of 0.79 micron periodicity operates in first order near 12.8 microns and was fabricated prior to the liquid-phase epitaxial growth using holographic exposure techniques. These DFB lasers had moderate thresholds, 3.6 kA/sq cm, and the output power versus current curves exhibited a sharp turn-on free of kinks. Clean, single-mode emission spectra, continuously tunable over a range in excess of 20 per cm, centered about 780 per cm (12.8 microns), and at an average rate of 1.2 per cm-K from 9 to 26 K, were observed. While weaker modes could at times be seen in the spectrum, substantially single-mode operation was obtained over the entire operating range and to over 10 times threshold.

Hsieh, H.-H.↗

The remote-controlled spectrograph, area scanner, and spectropolarimeter for the Lick 3-m telescope

A Cassegrain spectrograph used in conjunction with an image-tube, image-dissector scanner (ITS) is discussed with reference to its design features and operation. The spectrograph has a remote control feature, and its parameters, such as slit width, decker position, filter selection, focus, and grating selection, can be easily changed by computer command or a hard-wired control box. The discussion also includes the area scanner modification which allows raster scanning and limited picture taking. Finally, the design of a two-channel polarization analyzer is presented which allows simultaneous sky and sky-plus-star observations and faint-object polarimetry.

Miller, J. S.↗

Production of carbon, sulfur, and CS in Comet West

Results from ultraviolet spectrographic observations of Comet West (1975n) in the 1620-3960 A wavelength range are presented. Objective grating imagery of the comet reveals for the first time emission from sulfur atoms and CS molecules as well as previously observed lines or bands in carbon atoms and CO(+), CO2(+) and OH molecules. Some evidence exists for emission in the C2 Mulliken bands and in the CO Cameron bands. On the basis of the observations, production rates of C (ground state), C(1D), S, and CS are inferred to be 3.8 x 10 to the 29th per sec, 4.4 x 10 to the 29th per sec, 1.7 x 10 to the 28th per sec, and greater than approximately 3.1 x 10 to the 27th per sec, respectively.

Smith, A. M.↗

Measurements of mass flow in the transition region and inner corona

A solar rocket experiment launched on June 5, 1979 is described which provides high spectral resolution line profiles across the solar disk. The instrument consists of a small telescope with moderate spatial resolution and a spectrograph with stability and high spectroscopic resolution (about 0.028 A at 600 A). The detector system uses a microchannel plate array to provide 1,024 simultaneous measurements spanning approximately 30 A of the solar spectrum. The spectrograph uses a 3600 l/mm grating, and the spectral range 609-634 A is recorded in second order overlapping 1218-1268 A in first order. The position of the emission lines is determined by a center-of-mass routine and velocity shifts are evident. The qualitative results are in general agreement with the results of Cushman and Rense (1976).

Rottman, G. J.↗

A 10 micron heterodyne receiver for ultra high resolution astronomical spectroscopy

An improved CO2 laser heterodyne spectrometer is examined. The present system uses reflective optics to eliminate refocusing at different wavelengths, and the local oscillator is a line-center-stabilized isotopic CO2 laser. A tunable diffraction grating makes possible easy and rapid selection of over 50 transitions per isotope of CO2. The IF (0 to 1.6 GHz) from the HgCdTe photomizer is analyzed by a 128-channel filter bank, consisting of 64 tunable 5-MHz filters and 64 fixed 25-MHz RF filters. These filters provide resolving powers of about 1,000,000 to 10,000,000 and velocity resolution of 50 to 250 m/sec; their output is synchronously detected, integrated, multiplexed and stored in a buffer memory for the desired integration period. Kitt Peak observations show the wide spectral coverage, wide mixer and electronics bandwidth, and high sensitivity of the system.

Buhl, D.↗

The galactic center - 16-30 micron observations and the 18 micron extinction

Within the galactic center, ionized gas, stars, and heated dust are in close proximity to each other. Observations of the galactic center were made during two flight series on NASA aircraft flying at altitudes of more than 12 km. In both series the instrument used was a 10-channel liquid helium cooled grating spectrometer. Three 16-30 micrometers continuum spectra are presented along with two-color scans of the galactic center. No 18.71 micrometers line emission has been detected from Sgr A West. This is consistent with large dust extinction and normal S III/H II abundances. All three 16-30 micrometers continuum spectra show a broad depression centered at about 18 micrometers. This observation is attributed to absorption by cold silicate dust grains. The characteristics of a silicate model are discussed.

Mccarthy, J. F.↗

Airborne simultaneous spectroscopic detection of laser-induced water Raman backscatter and fluorescence from chlorophyll a and other naturally occurring pigments

The airborne laser-induced spectral emission bands obtained simultaneously from water Raman backscatter and the fluorescence of chlorophyll and other naturally occurring waterborne pigments are reported here for the first time. The importance of this type data lies not only in its single-shot multispectral character but also in the application of the Raman line for correction or calibration of the spatial variation of the laser penetration depth without the need for in situ water attenuation measurements. The entire laser-induced fluorescence and Raman scatter emissions resulting from each separate 532-nm 10-nsec laser pulse are collected and spectrally dispersed in a diffraction grating spectrometer having forty photomultiplier tube detectors. Results from field experiments conducted in the North Sea and the Chesapeake Bay/Potomac River are presented. Difficulties involving the multispectral resolution of the induced emissions are addressed, and feasible solutions are suggested together with new instrument configurations and future research directions.

Hoge, F. E.↗

Scattering of waves from periodic surfaces

In order to study the scattering of waves from periodic surfaces, the basic grating equations are reviewed, and a general approach for scattering from impenetrable and penetrable media is formulated. Three analytical methods for scattering on a conducting sinusoidal surface for both TE and TM polarized waves are compared. In The Masel, Merrill, and Miller (MMM) method for quantum scattering of atoms (1975, 1976), the surface field expansions are expressed in terms of Fourier series. The Modified Physical Optics (MPO) method (DeSanto, 1975; Whitman and Schwering, 1977) uses surface field expansions consisting of a leading term proportional to the physical optics approximation multiplied by a Fourier series expansion. The Waterman's Plane Harmonics (WPH) approach (1975) makes use of basis functions which are downward plane harmonics evaluated on the surface. The MMM method proved to be the most efficient one in terms of rate and range of convergence. For dielectric media with periodic rough surfaces, an improved method is developed for calculating the reflected and transmitted powers, and the results are compared with experimental data obtained at optical frequencies.

Chuang, S.-L.↗