Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Golden”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

High-Resolution South American Wind Resource Data Downscaled with Generative Machine Learning Conditioned on Near-Surface Observations

High-resolution historical wind data was developed for the entirety of South America using the innovative Super-Resolution for Renewable Resource Data (sup3r) machine learning framework. The publicly available Sup3rWind South America dataset represents a significant advancement in wind resource data generation, leveraging generative machine learning conditioned on near-surface observations from the Meteorological Assimilation Data Ingest System (MADIS) to efficiently and accurately downscale coarse reanalysis data from the European Centre for Medium-Range Weather Forecasts (ERA5). This approach produces fine-scale, spatially and temporally coherent wind and meteorological fields hundreds of times more computationally efficient than traditional numerical weather modeling methods, enabling access to high-fidelity wind information across both continental and offshore regions. Sup3rWind South America builds on the earlier Sup3rWind Ukraine dataset through improvements in model architecture and outputs conditioned on near-surface observation inputs. As with the Ukraine data release, this dataset includes wind speed, wind direction, temperature, relative humidity, and pressure at a horizontal resolution of ~2 km, representing a 15x spatial enhancement relative to the 31 km ERA5 grid. Wind speed and direction are provided at 5-minute resolution, a 12x temporal refinement compared to the hourly ERA5 data, while temperature, relative humidity, and pressure remain at hourly resolution. The data covers all years from 2005 to 2024. Before downscaling, ERA5 inputs were bias-corrected using long-term monthly means and a limited number of quality-controlled observations to align large-scale statistics with regional conditions. The resulting dataset is the first publicly available high-resolution timeseries wind record that provides full spatial coverage of South America. Model validation demonstrates strong agreement with observations across several statistical metrics, consistent with other state-of-the-art high-resolution wind resource datasets. The potential applications of Sup3rWind South America span renewable energy resource assessment, energy system modeling, and grid resilience analysis. The 20-year record and high spatial and temporal resolution support accurate estimation of long-term energy yield and the economic feasibility of potential wind development sites. Continuous coverage across both continental and offshore regions enables comprehensive site prospecting within exclusive economic zones. The 2 km, 5-minute resolution data provide the spatial and temporal variability required for power system simulation, operational planning, and regional risk assessments.

17 WIND ENERGY↗

Evolving Electricity Supply and Demand to Achieve Net-Zero Emissions: Insights from the EMF-37 Study

This paper explores the role of electricity in achieving economy-wide net-zero CO2 emissions by 2050 in the United States based on results from 17 models as part of the 37th Stanford Energy Modeling Forum (EMF-37). In the study's Net-Zero scenario, the models use diverse pathways to achieve net-zero emissions by 2050, with gross energy-related residual emissions ranging from 17.2 to 66.6 % of 2020 levels. Electricity consistently emerges as central to achieving net-zero, with models projecting rapid electrification of end-uses and rapidly declining CO2 intensity of electricity. However, the extent of electrification and the technology mix to decarbonize the power sector vary considerably across models. In the Net-Zero scenario, electricity is projected to evolve from ~20 % of final energy in 2020 to 17-63 % in 2050 across the models driven by electrification in all sectors-buildings, industry, and transportation-and, to a lesser extent by direct air capture. By 2050, total electricity consumption increases by 24-176 % (relative to 2020), accompanied by significant expansion in renewable electricity production. Together, solar and wind generation grows by 175-834 %, supplying 45-90 % of total electricity in 2050, with wind achieving slightly higher shares than solar. Electricity storage technologies are deployed at scale to support wind and solar generation. The electricity generation mix varies across models: some project almost complete reliance on renewables, while others see a substantial role for natural gas, often with carbon capture and storage. This paper synthesizes the rich diversity of modeling approaches and results, highlighting differing views on how key drivers of electricity demand and supply might evolve.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Scaling of energy delivered through an electrostatic discharge to a small series load

We study the energy delivered through a small-resistance series “victim” load during electrostatic discharge events in air. For gap lengths over 1 mm, the fraction of the stored energy delivered is mostly gap-length independent, with a slight decrease at larger gaps due to electrode geometry. The energy to the victim scales linearly with circuit capacitance and victim load resistance but is not strongly dependent on circuit inductance. This scaling leads to a simple approach to predicting the maximum energy that will be delivered to a series resistance for the case where the victim load resistance is lower than the spark resistance.

42 ENGINEERING↗

Experimental characterization and potential energy savings of insulated cladding for U.S. residential buildings

This study evaluates a novel insulated cladding composed of foamed cement and vinyl siding that is designed as a retrofit product to enhance thermal performance in U.S. residential buildings. Experimental measurements showed that foamed cement exhibits a thermal conductivity of 0.0334–0.0365 W/m-K (R-value of 4.0–4.3 °F⋅ft 2 ⋅h/BTU), which is significantly higher than that of conventional fiber cement boards. Although mechanical testing confirmed the material’s brittleness and low strength, it also indicated its suitability for nonstructural insulation applications. Water vapor permeability testing demonstrated effective moisture resistance with the polymer coating. To evaluate the insulated cladding’s energy performance, we used the U.S. Department of Energy’s prototype single-family building model and simulated across 50 locations spanning 16 International Energy Conservation Code climate zones. The R-7 (R-value of 7 °F⋅ft 2 ⋅h/BTU per inch) retrofit cladding resulted in heating energy savings up to 275 therms (Fairbanks, AK) and cooling energy savings up to 1,547 kWh (Phoenix, AZ). The energy cost savings varied by region, but the highest annual cost savings ($\$$434/year) were observed in Santa Maria, CA, and the highest annual cost savings percentage (37 %) were noted in Monterey, CA. On a national scale, the insulated retrofit provided an average annual energy cost reduction of 16 %, highlighting the cladding system’s broad applicability and financial viability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Conditional distribution estimation of building characteristics with diffusion models for urban energy modeling

Understanding current energy consumption behavior in communities is critical for informing future energy use decisions and enabling efficient energy management. Urban energy models, which are used to simulate these energy use patterns, require large datasets with detailed building characteristics for accurate outcomes. However, such detailed characteristics at the individual building level are often unknown and costly to acquire, or unavailable. Through this work, we propose using a generative modeling approach to generate realistic building attributes to fill in the data gaps and finally provide complete characteristics as inputs to energy models. Our model learns complex, building-level patterns from training on a large-scale residential building stock model containing 2.2 million buildings. We employ a tabular diffusion-based framework that is designed to handle heterogeneous (discrete and continuous) features in tabular building data, such as occupancy, floor area, heating, cooling, and other equipment details. We develop a capability for conditional diffusion, enabling the imputation of missing building characteristics conditioned on known attributes. We conduct a comprehensive validation of our conditional diffusion model, firstly by comparing the generated conditional distributions against the underlying data distribution, and secondly, by performing a case study for a Baltimore residential region, showing the practical utility of our approach. Our work is one of the first to demonstrate the potential of generative modeling to accelerate building energy modeling workflows.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hydrogen Production System Scaling Using a High-Fidelity Simulation-Optimization Framework

Proton exchange membrane (PEM) electrolyzers are widely used for hydrogen production, yet few validated, high-fidelity tools can reliably guide scale-up. Using measured performance from a 50-hour hardware-in-the-loop pilot test, a physics-based, plant-level model of a 1.25 MW PEM electrolyzer and its balance-of-plant (BoP) subsystems is developed and validated. The model couples electrochemistry and thermal/flow submodels and is calibrated against pilot test data via a genetic algorithm (GA) workflow. Validation yields a mean absolute percentage error (APE) of 0.43% for cell voltage and stack power. Two scale-out strategies are then benchmarked under a common 7-day wind-and-photovoltaic (PV) profile: (i) linear duplication of 1.25 MW blocks and (ii) shared-BoP architectures. Sharing BoP between stacks reduces BoP energy by 27% at 10 MW and 34% at 100 MW (vs. linear duplication) and improves system specific energy consumption (SEC) to 52.9 and 52.6 kWh/kg, respectively (from 54.0 kWh/kg with linear duplication). Partial-load studies (25-100% set-point) show that cumulative hydrogen production remains nearly constant down to 50% load because all cases use the same weekly renewable-energy input. Below 50%, the power cap limits how much energy can be used within 168 h, which reduces hydrogen output. The model further indicates that the practical operating optimum lies between 50% and 85% load, where efficiency gains begin to appear without significant loss in hydrogen output. Moreover, the efficiency gains at lower loads are offset by reduced production. The validated framework supports scenario-based engineering trade-off studies for large configurations (10-100 MW) and for operating policies under variable renewables.

08 HYDROGEN↗

Sparse chronology strategy for integrating seasonal energy storage in capacity expansion models

Here, this study develops the sparse chronology method to enhance the representative period framework in capacity expansion models, enabling the effective integration of long-duration energy storage modeling. Traditional representative period methods cannot capture the state of charge of seasonal energy storage systems because they do not establish effective inter-day linkages to connect the state of charge between periods. The sparse chronology approach addresses this limitation by establishing inter-day linkages that allow state of charge to shift inter-seasonally. At the same time, it groups identical representative days into partitions, applying constraints sparsely and implicitly to reduce computational load further. Validation results demonstrate that this method successfully simulates long-duration energy storage patterns, achieving close alignment with a continuous yearly benchmark model, with seasonal trends and state of charge cycles clearly represented. The computational load analysis reveals that the sparse chronology method efficiently applies constraints on maximum and minimum state of charge limits within the representative day framework, eliminating the need for detailed constraints on each individual day. By partitioning representative days and constraining only the start and end of each partition, the method significantly decreases computational requirements. Simulation results show that sparse chronology closely approximates the continuous yearly method's accuracy, even with as few as 20 representative days, achieving correlation values with the benchmark of nearly 0.9 in state of charge plots. Furthermore, it maintains computational efficiency, requiring only 4 % of the solver time compared to the continuous yearly method with 20 representative days. This approach allows capacity expansion models to incorporate long-duration energy storage with high temporal, spatial, and technological resolution, enabling more detailed modeling for large-scale power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Linking structure to performance: Characterization of porous transport layers for high-pressure water electrolysis

Proton exchange membrane (PEM) water electrolysis is a promising technology to produce cost-efficient hydrogen. PEM electrolyzers offer a large current density range and the ability to operate at differential pressure which can be used to minimize both capital and operational expenditures. However, directly producing pressurized hydrogen at the cathode results in pushing the membrane against the anode porous transport layer (PTL). This can lead to detrimental effects, such as membrane deformation or ruptures, which depend on membrane properties as well as PTL material properties such as pore size, structure, and morphology. In this work, a range of sinter and felt-based commercial PTLs are evaluated for their contributions to the cell's electrochemical and H 2 crossover performance at cathode pressures up to 30 bar. X-ray tomography and post-operando optical microscopy are used to assess the morphology of the PTLs, and the PTL induced deformation experienced by the catalyst coated membrane (CCM), respectively. PTL samples with lower porosity were found to reduce both the cell voltage and the amount of H 2 permeating from the cathode to the anode exhaust, which was ascribed to improved catalyst layer contact and reduced membrane deformation, respectively. The best performing PTLs improved electrolyzer efficiency by ~1.5 kWh/kg H2 . Specifically, 1 kWh/kg H2 was gained due to reducing membrane deformation and decreasing H 2 crossover. The remainder 0.5 kWh/kg H2 were achieved by improving the electrical contact at the electrode/PTL interface which decreased cell voltage.

08 HYDROGEN↗

Grid-responsive hydrogen production: Capital utilization and current density vs. efficiency in variable electricity markets

To achieve low-cost hydrogen production from water electrolyzers, grid tied electrolysis may need to operate dynamically to minimize the cost of supplying energy to the electrolyzer stack and produce hydrogen during low-cost hours and turn off/down during high-cost hours. Operating systems in this way can decrease capital utilization (capacity factor) and electricity costs. This strategy would shift the dominant cost drivers away from electricity (and thus efficiency) to the capital costs of the system, due to the underutilized capital when operating at low-capacity factors. Increasing the operational current density of the system could, in effect, reduce the capital cost of the system while producing hydrogen at a lower efficiency on a per unit energy basis. In the variable electricity cost profiles analyzed in this paper, increasing the current density for liquid alkaline from 0.5 A/cm2 to 1.5 Ac/m2 and proton exchange membrane electrolyzers from 2 A/cm2 to 4 A/cm2 resulted in substantial reductions in the levelized cost of hydrogen. Additionally, as capacity factors and electricity costs decrease, the optimal operating current density of the electrolyzer systems analyzed increases. These findings suggest R&D efforts should focus on increasing the operational current densities, reducing the turn down ratios, and understanding the durability implications of those strategies on low-temperature liquid alkaline and proton exchange membrane electrolyzers.

08 HYDROGEN↗

The past, present, and future of peaking thermal power plants in the United States

Today's power systems rely on "peaker plants" to reliably serve load during peak demand periods. In this study we consider the present competitiveness of different peaking options, how much and what kinds of plants have provided U.S. peaking capacity, and potential future peaking fleet compositions. We explore how capital intensity impacts the breakeven capacity factor between two potential resources: combustion turbines (CTs) and combined cycle plants (CCs). CTs outcompete CCs below 12%-17% annual capacity factor at today's prices, but can shift with changes to fuel or start costs. Historically, gas CTs and petroleum steam plants most closely fit the role of peakers. Peaking capacity could grow from approximately 280 GW today to 460-770 GW in 2050 composed of a wider range of resources. We conclude by discussing implications of this shift, with a focus on the potential planning considerations for shifting to a greater utilization of CCs for peaking needs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Universal Workflow Language and Software Enable Geometric Learning and FAIR Scientific Protocol Reporting

Written language and conventional data structures for representing scientific procedures suffer from low process detail, often fail to accurately represent protocols, and lack universality. New strategies for the handling of experimental data are needed to provide viable process information for both humans and machines. In this work, we present the universal workflow language (UWL) and interface (UWLi). UWL is a findable, accessible, interoperable, and reusable (FAIR)-compatible, graph-based data architecture that can capture arbitrary scientific procedures through workflow representation, and UWLi is an accompanying software package for building, manipulating, and interpreting UWL entries. The UWL format was found to be highly effective in identifying deficiencies in the reported process details of high-impact, peer-reviewed scientific journals, and in simulated scenarios, the graph format was shown to be more effective than conventional methods in predictively modeling the outcome of diverse scientific protocols. Implementation of UWL could enable more accurate scientific communication and more impactful process datasets.

14 SOLAR ENERGY↗

A novel microstructural approach for TRIP/TWIP β-Ti alloys using intermetallic precipitation

Interest in metastable β-Ti has grown, due to the exceptional work hardening caused by TRansformation and TWinning Induced Plasticity (TRIP/TWIP). A current challenge is increasing the yield strength, while maintaining the benefits of TRIP/TWIP. This study presents the first report of TRIP/TWIP in a metastable β-Ti alloy containing intermetallic compounds, specifically Ti silicide precipitates. Silicon (Si) additions enable the formation of silicide particles, which can be precipitated, dissolved, and controlled through tailored heat treatments. In-situ synchrotron x-ray diffraction during tensile testing reveals primary {332}<113> twinning activates first, followed by TRIP, leading to extensive work hardening and uniform elongation in the solutionized state. In conclusion, these findings open a novel microstructural approach to the design of multiphase TRIP/TWIP titanium alloys, relying on intermetallic precipitation rather than allotropes such as α or ω phase, and lay the groundwork for future studies on intermetallic precipitation strengthening.

Materials science↗

Cost estimation of balance of plant equipment scale up for proton exchange membrane water electrolyzer systems

Water electrolyzers that use electricity to split water into hydrogen and oxygen could be a key technology for increasing hydrogen supply to meet expanded and emerging market applications, although currently the capital costs of these electrolyzers are high. Here we examine cost reductions that might be achieved by scaling up proton exchange membrane (PEM) electrolyzer systems and leveraging economies of scale through balance of plant (BOP) components for system sizes between 1 MW and 1 GW. We estimate BOP equipment capital costs of about $\$$848/kW at 1 MW, potentially decreasing to $\$$87/kW at 1 GW (2022-dollar year basis) with most of the cost reduction happening as systems scale from 1 MW to 100 MW. We find that BOP subsystems hydrogen drying and water knockout benefited the most from economies-of-scale cost reductions, and piping, instrumentation, and housing and power electronics were less impacted. These cost reductions from economies of scale could be more significant than estimated cost reductions from manufacturing scale-up reported in literature. These results add to the knowledge base that could guide optimal system designs that balance process scale-up with plant modularization and numbering-up. We also estimate that scaling up BOP could potentially lower the levelized cost of hydrogen (LCOH) by $\$$1.7-$\$$4.6/kg, depending on the scale-up magnitude and the plant capacity factor.

08 HYDROGEN↗

Modal dynamics of wind turbine wake meandering from lidar observations

Horizontal scans from nacelle-mounted lidars provide time series measurements of wind turbine wakes across diverse atmospheric conditions, enabling analysis of coherent turbulent structures that influence wake meandering through proper orthogonal decomposition (POD). While low-order modes capture the most energetic turbulent structures, our analysis reveals that they do not necessarily dominate wake meandering dynamics. We evaluate more than 16,000 combinatorial reconstructions of the flow field for each inflow case, demonstrating that mode relevance depends on mode symmetry, turbulent kinetic energy content, and inflow characteristics. Cases with low turbulence intensity and large integral timescales show stronger correlations between POD modes and wake meandering, whereas higher turbulence conditions (turbulence intensity > 7%) are less effectively described by reduced-order models. However, the qualitative similarity of POD modes across varied atmospheric conditions suggests the potential existence of a semi-universal basis for representing wind turbine wakes, with implications for improving engineering wake models.

17 WIND ENERGY↗

Impacts of Solar Land Availability on the Evolution of the U.S. Power System

Long-term planning scenarios of the United States electricity system have not identified solar resource availability to be a limiting factor in how much solar capacity might be deployed. However, there are some smaller regions where siting challenges indicate solar deployment could be limited by solar resource availability. In this work, we use geospatial modeling tools to develop a restrictive siting scenario that significantly reduces the amount and location of utility-scale solar resources. We use that restrictive siting regime, along with other previously defined siting scenarios, to examine how solar resource availability impacts the buildout of the electricity system using business-as-usual and decarbonization futures in a national-scale capacity expansion model. The restrictive siting scenario uses observed siting pressures to exclude many types of land on which development is allowed today and results in a greater than 90% reduction in solar resource potential-to approximately 3000 GW. Even with this drastic reduction, utility-scale solar capacity grows by more than 3 times through 2050 in the business-as-usual scenarios and by more than 6 times in the decarbonization scenarios, though less solar is deployed in scenarios with lower available solar resource. We quantify how system costs and generation mixes change as solar resource availability changes.

14 SOLAR ENERGY↗

Advancements in reflected target nonintrusive assessment (ReTNA) for large optical surface measurement

Reflected computer vision targets are a powerful tool for measurement of mirror surface shape, with several important advantages over traditional fringe deflectometry methods. This method was first presented in 2021 and has undergone significant improvement and demonstration since. We describe a new baseline system using reflected computer vision targets, and present results from a large-scale measurement campaign conducted on both commercial heliostats and test mirrors in the laboratory. Calibration of the measurement system with photogrammetry allows for accurate measurement without careful control of target shape or camera position. Overall, the results show that a baseline setup using this method achieves measurement uncertainties in the slope error root-mean-square less than ±0.11 milliradian due to a series of repeatability conditions, varying sample position, rotation, lighting, camera settings, and system rebuild and recalibration. We present a detailed description of the setup, the results generated by this measurement tool, repeated measurement results, and the strengths and limitations of this metrology system.

14 SOLAR ENERGY↗

Heliostat sizing methodology for concentrating solar thermal industrial process heat projects

This study presents a method to obtain a heliostat size that minimizes the levelized cost of heat (LCOH) of a heliostat-based concentrating solar thermal system for applications of solar heating for industrial processes at operating temperatures from 565 to 1550°C. The method extends prior work by embedding a routine for system design that obtains near-optimal subsystem sizes, increasing the fidelity of drive cost functions, and adding an optical performance model to supplement the previously developed cost models, which we update to reflect current pricing trends. An illustrative business case is developed for Daggett, California, targeting specified annual thermal energy outputs of 50 to 400 GWh th . Optical performance is modeled using verified estimates from the literature. A surrogate heliostat cost model, derived from commercial heliostat designs and scaled for production volume, installation, and operations and maintenance costs, is used to develop cost functions. Results show that heliostat size strongly affects the LCOH, producing a characteristic U-shaped trend with a robust near-optimal window of 7-20 m 2 ; the heliostat size producing the lowest project cost in our study grows slightly as the project size increases, and is reduced as the operating temperature increases. The findings in this study are consistent with the general trend of smaller heliostats being deployed at existing projects for high-temperature industrial process heat and reflect the significant reduction in power electronics and other per-heliostat costs. The methodology we propose is general and can be tailored to revised cost curves as the technology continues to evolve.

14 SOLAR ENERGY↗