System for monitoring physical characteristics of fluids

An apparatus and method are described for measuring physical characteristics of fluid, by placing a drop of the fluid in a batch of a second fluid and passing acoustic waves through the bath. The applied frequency of the acoustic waves is varied, to determine the precise value of a frequency at which the drop undergoes resonant oscillations. The resonant frequency indicates the interfacial tension of the drop in the bath, and the interfacial tension can indicate physical properties of the fluid in the drop.

Trinh, E. H.↗

Advanced optical measuring systems for measuring the properties of fluids and structures

Four advanced optical models are reviewed for the measurement of visualization of flow and structural properties. Double-exposure, diffuse-illumination, holographic interferometry can be used for three-dimensional flow visualization. When this method is combined with optical heterodyning, precise measurements of structural displacements or fluid density are possible. Time-average holography is well known as a method for displaying vibrational mode shapes, but it also can be used for flow visualization and flow measurements. Deflectometry is used to measure or visualize the deflection of light rays from collimation. Said deflection occurs because of refraction in a fluid or because of reflection from a tilted surface. The moire technique for deflectometry, when combined with optical heterodyning, permits very precise measurements of these quantities. The rainbow schlieren method of deflectometry allows varying deflection angles to be encoded with colors for visualization.

Decker, A. J.↗

Assessment of numerical methods for the solution of fluid dynamics equations for nonlinear resonance systems

The capability of accurate nonlinear flow analysis of resonance systems is essential in many problems, including combustion instability. Classical numerical schemes are either too diffusive or too dispersive especially for transient problems. In the last few years, significant progress has been made in the numerical methods for flows with shocks. The objective was to assess advanced shock capturing schemes on transient flows. Several numerical schemes were tested including TVD, MUSCL, ENO, FCT, and Riemann Solver Godunov type schemes. A systematic assessment was performed on scalar transport, Burgers' and gas dynamic problems. Several shock capturing schemes are compared on fast transient resonant pipe flow problems. A system of 1-D nonlinear hyperbolic gas dynamics equations is solved to predict propagation of finite amplitude waves, the wave steepening, formation, propagation, and reflection of shocks for several hundred wave cycles. It is shown that high accuracy schemes can be used for direct, exact nonlinear analysis of combustion instability problems, preserving high harmonic energy content for long periods of time.

Przekwas, A. J.↗

Design of Fiber Optic Sensors for Measuring Hydrodynamic Parameters

The science of optical hydrodynamics involves relating the optical properties to the fluid dynamic properties of a hydrodynamic system. Fiber-optic sensors are being designed for measuring the hydrodynamic parameters of various systems. As a flowing fluid makes an encounter with a flat surface, it forms a boundary layer near this surface. The region between the boundary layer and the flat plate contains information about parameters such as viscosity, compressibility, pressure, density, and velocity. An analytical model has been developed for examining the hydrodynamic parameters near the surface of a fiber-optic sensor. An analysis of the conservation of momentum, the continuity equation and the Navier-Stokes equation for compressible flow were used to develop expressions for the velocity and the density as a function of the distance along the flow and above the surface. When examining the flow near the surface, these expressions are used to estimate the sensitivity required to perform direct optical measurements and to derive the shear force for indirect optical measurements. The derivation of this result permits the incorporation of better design parameters for other fiber-based sensors. Future work includes analyzing the optical parametric designs of fiber-optic sensors, modeling sensors to utilize the parameters for hydrodynamics and applying different mixtures of hydrodynamic flow. Finally, the fabrication of fiber-optic sensors for hydrodynamic flow applications of the type described in this presentation could enhance aerospace, submarine, and medical technology.

Lyons, Donald R.↗

Cryogenic Fluid Management Technologies for Advanced Green Propulsion Systems

In support of the Exploration Vision for returning to the Moon and beyond, NASA and its partners are developing and testing critical cryogenic fluid propellant technologies that will meet the need for high performance propellants on long-term missions. Reliable knowledge of low-gravity cryogenic fluid management behavior is lacking and yet is critical in the areas of tank thermal and pressure control, fluid acquisition, mass gauging, and fluid transfer. Such knowledge can significantly reduce or even eliminate tank fluid boil-off losses for long term missions, reduce propellant launch mass and required on-orbit margins, and simplify vehicle operations. The Propulsion and Cryogenic Advanced Development (PCAD) Project is performing experimental and analytical evaluation of several areas within Cryogenic Fluid Management (CFM) to enable NASA's Exploration Vision. This paper discusses the status of the PCAD CFM technology focus areas relative to the anticipated CFM requirements to enable execution of the Vision for Space Exploration.

Motil, Susan M.↗

Advanced long term cryogenic storage systems

Long term, cryogenic fluid storage facilities will be required to support future space programs such as the space-based Orbital Transfer Vehicle (OTV), Telescopes, and Laser Systems. An orbital liquid oxygen/liquid hydrogen storage system with an initial capacity of approximately 200,000 lb will be required. The storage facility tank design must have the capability of fluid acquisition in microgravity and limit cryogen boiloff due to environmental heating. Cryogenic boiloff management features, minimizing Earth-to-orbit transportation costs, will include advanced thick multilayer insulation/integrated vapor cooled shield concepts, low conductance support structures, and refrigeration/reliquefaction systems. Contracted study efforts are under way to develop storage system designs, technology plans, test article hardware designs, and develop plans for ground/flight testing.

Brown, Norman S.↗

Compton Scattering by Static and Moving Media: The Transfer Equation and its Moments - Part 1

Compton scattering of photons by nonrelativistic particles is thought to play an important role in forming the radiation spectrum of many astrophysical systems. Here we derive the time-dependent photon kinetic equation that describes spontaneous and induced Compton scattering, as well as absorption and emission by static and moving media, the corresponding radiative transfer equation, and their zeroth and first angular moments, both in the system frame and in the frame comoving with the medium. We show that it is necessary to use the correct relativistic differential scattering cross section in order to obtain a photon kinetic equation that is correct to first order in Epsilon/m(sub e), T(sub e)/m(sub e), and V, where Epsilon is the photon energy, T(sub e) and m(sub e) are the electron temperature and rest mass, and V is the electron bulk velocity in units of the speed of light. We also demonstrate that the terms in the radiative transfer equation that are second order in V should usually be retained, because if the radiation energy density is sufficiently large, compared to the radiation flux, the effects of bulk Comptonization described by the terms that are second order in V can be as important as the effects described by the terms that are first order in V, even when V is small. The system- and fluid-frame equations that we derive are correct to first order in Epsilon/m(sub e). Our system-frame equations, which are correct to second order in V, may be used when V is not too large. Our fluid-frame equations, which are exact in V, may be used when V approaches 1. Both sets of equations are valid for systems of arbitrary optical depth and can therefore be used in both the free-streaming and diffusion regimes. We demonstrate that Comptonization by the electron bulk motion occurs whether or not the radiation field is isotropic or the bulk flow converges and that it is more important than thermal Comptonization if V(sup 2) is greater than 3T(sub e)/m(sub e).

Psaltis, Dimitrios↗

Proposed Space Flight Experiment Hardware

The primary thrust for this plan is to develop design tools and fundamental understanding that are timely and consistent with the goal of the various exploration initiatives. The plan will utilize ISS facilities, such as the Fluids Integrated Rack (FIR) and the Microgravity Science Glovebox (MSG). A preliminary flow schematic of Two-Phase Flow Facility (T(phi)FFy) which would utilize FIR is shown in Figure 3. MSG can be utilized to use the Boiling eXperiment Facility (BXF) and Contact Line Dynamics Experiment (CLiDE) Facility. The T(phi)FFy system would have multiple test sections whereby different configurations of heat exchangers could be used to study boiling and condensation phenomena. The test sections would be instrumented for pressure drop, void fraction, heat fluxes, temperatures, high-speed imaging and other diagnostics. Besides a high-speed data acquisition system with a large data storage capability, telemetry could be used to update control and test parameters and download limited amounts of data. In addition, there would be multiple accumulators that could be used to investigate system stability and fluid management issues. The system could accommodate adiabatic tests through either the space station nitrogen supply or have an experiment-specific compressor to pressurize a sufficient amount of air or other non-condensable gas for reuse as the supply bottle is depleted.

Source record↗

Coupling a Computational Fluid Dynamics Model to a Spacecraft Thermal System Model for the DraMS Instrument Thermal Analysis

The Dragonfly Mass Spectrometer (DraMS) is an instrument on the Dragonfly mission, which will spend 7 years in deep space cruise before landing and operating on the surface of Titan. Vacuum thermal analyses are required for deep space cruise, and convection analyses are required for the Titan surface operations. Model exchanges across multiple thermal teams are needed for all phases of the mission. For DraMS, Thermal Desktop® (TD) has been the main thermal analytical tool of choice due to its capability in modeling complex thermal systems with relatively low computational power and for its availability across thermal teams. However, TD does not have computational fluid dynamics (CFD) capability and struggles to accurately capture complex convective behavior. DraMS has fans operating in tandem and gas flow behaviors are not easily predicted due to its complex flow paths. CFD software, such as Fluent, can model and predict such complex flow behaviors, but CFD models are computationally expensive, and its workflow processes are not tailored towards simulating large and complex systems. Therefore, a coupled modeling approach was chosen for DraMS: A TD model was used for simulating all the conductive, radiative, and source terms, while a Fluent CFD model was added on, as needed, to the TD model to provide the convective boundary conditions using the System Coupling software. The coupling software allows the TD and Fluent models to communicate data and arrive at a co-solved and co-converged solution. Furthermore, Thermal Iso-value Exchange (TIE) method was developed to facilitate and improve the TD-Fluent data exchange process. This paper will discuss the analytical studies that were done to verify the accuracy and usability of the coupled approach and the challenges associated, which lead to the development of the TIE approach. DraMS thermal design and co-solved analysis results will also be discussed.

Heat transfer↗

Validation of Thermodynamic Vent System Performance using Thermal Desktop

Cryogenic fluid management (CFM) for in-space propulsion systems is crucial to enabling future space missions. A means to control the pressure inside a propellant tank is necessary to prevent the venting of liquid propellant in microgravity environments. A thermodynamic vent system (TVS) is one way to regulate the pressure and temperature of the fluid inside a tank. A previous study created a simplified model of a TVS in a two-phase cryogenic heat exchanger. The TVS expands the working fluid across a Joule-Thomson (J-T) device and routes the cooled fluid through the heat exchanger to remove heat from the surrounding fluid. The model was able to predict the TVS heat extraction performance and was validated against experimental data using the same hardware. This study expands the model of the TVS into Thermal Desktop (TD) and recreates the results from both the original model and the experimental data. This new TD model has the potential to be used to predict TVS heat extraction performance in cryogenic propellant tanks for future space missions.

Cryogenic Fluid Management↗

Improved natural convection heat transfer correlations for reactor cavity cooling systems of high-temperature gas-cooled reactors: From computational fluid dynamics to Pronghorn

The Reactor Cavity Cooling System (RCCS) is a common reactor safety system in High Temperature Gas Cooled Reactors (HTGR) that removes heat from the Reactor Pressure Vessel (RPV) by radiation ($\sim 80\%$) and natural convection ($\sim 20\%$). For simulation of accident scenarios of HTGRs, intermediate fidelity and system codes models must be employed for limiting the models' execution time. While accurate quantification of the radiative heat transfer is available in these models, quantification of natural convection must rely on correlations of questionable accuracy for the Nusselt number. Commonly used correlations are based in experiments performed at low Rayleigh numbers and/or using isothermal walls in simplified geometries. Here, this work improves on the accuracy of natural convection heat transfer correlations in support for HTGR designs. These correlations include both local and average Nusselt numbers as a function of the global Rayleigh number, the local Rayleigh number, and the temperature profile at the hot wall of the RCCS. In the absence of dedicated experiments and the difficulty of performing high-fidelity simulations at realistic Rayleigh numbers, the data to fit the correlations are generated with Computational Fluid Dynamics (CFD) using Reynolds Averaged Navier-Stokes (RANS) models. First, a careful selection of the RANS turbulence model is performed by comparing the results obtained with different RANS turbulence models against high fidelity simulations of natural convection at $Ra \ 1 \times 10^{11}$ in a rectangular cavity. Next, the selected model is used to perform simulations of an HTGR cavity at different high Rayleigh numbers $\in [6.1 \times 10^{11},2.9 \times 10^{13}]$ to encompass several HTGR designs, assuming an isothermal RPV wall. The results obtained are used to fit a correlation for the average and space-varying Nusselt number as a function of the global and local Rayleigh numbers via a sparsity-promoting least-squares method. The selected RANS model is then used to perform simulations of a PBMR 400 HTGR cavity with the temperature profiles at the RPV wall obtained during a PLOFC transient. We use the results obtained to fit a temperature-dependent correction to the space-varying Nusselt number with the sparsity-promoting least-squares method. The results obtained in this work, enable system-level codes, such as Pronghorn, to perform higher-fidelity simulations of the heat exchange process in the RCCS while still maintaining a low computational cost.

42 ENGINEERING↗

Imaging Fluid Flow

Electro-optical system allows simultaneous viewing of schlieren, shadowgraph and interferometric images of volume of fluid under test. In imaging system cube beam splitters replaced by plate-type beam splitters or pellicle beam splitters.

Witherow, W. K.↗

Thermal Imaging of Convecting Opaque Fluids using Ultrasound

An ultrasound technique has been developed to non-intrusively image temperature fields in small-scale systems of opaque fluids undergoing convection. Fluids such as molten metals, semiconductors, and polymers are central to many industrial processes, and are often found in situations where natural convection occurs, or where thermal gradients are otherwise important. However, typical thermal and velocimetric diagnostic techniques rely upon transparency of the fluid and container, or require the addition of seed particles, or require mounting probes inside the fluid, all of which either fail altogether in opaque fluids, or necessitate significant invasion of the flow and/or modification of the walls of the container to allow access to the fluid. The idea behind our work is to use the temperature dependence of sound velocity, and the ease of propagation of ultrasound through fluids and solids, to probe the thermal fields of convecting opaque fluids non-intrusively and without the use of seed particles. The technique involves the timing of the return echoes from ultrasound pulses, a variation on an approach used previously in large-scale systems.

Xu, Hongzhou↗