Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EXPOSURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Spacecraft Water Exposure Guidelines For Selected Contaminants

Construction of the International Space Station (ISS)a multinational effort began in 1999. In its present configuration, the ISS is expected to carry a crew of three to six astronauts for up to 180 days (d). Because the space station is a closed and complex environment, some contamination of its internal atmosphere and water system is unavoidable. Several hundred chemical contaminants are likely to be found in the closed-loop atmosphere and recycled water of the ISS. To protect space crews from contaminants in potable and hygiene water, the National Aeronautics and Space Administration (NASA) requested that the National Research Council (NRC) provide guidance on how to develop water exposure guidelines and subsequently review NASA's development of the exposure guidelines for specific chemicals.

Water↗

The Effects to Exposure of Simulated Spaceflight Radiation on Behavioral Health of Male and Female Mice

Exposure to space radiation is a principal consideration of spaceflight missions as risk is leveraged as time and dose—both expected to increase with future missions to the Moon, Mars, and beyond. Previous mission exposure levels, galactic cosmic radiation (GCR) and solar particle events (SPE), have been characterized as increased compared to those natural to Earth and are predicted to cause robust deficits at higher doses and longer durations. The cognitive health implications of this critical difference are understood as risks to mission and crew operations. We examined potential radiation-induced disruptions on brain health through resting-state in-cage behavior. 23–24-week-old male and female mice were exposed to 0 cGy (Sham), 5 cGy, 15 cGy, and 50 cGy via Five-Ion GCR Simulation (H, Si, He, O, Fe) at the NASA Space Radiation Lab in Brookhaven National Labs. Behavioral and cognitive performance were evaluated via frequency/duration of digging, rearing, and grooming within the 72-hour period immediately following irradiation. Additionally, during this time we evaluated nestlet building using a 5-stage Deacon score, rating shredding and shelter assembly of cotton material from untouched (1) to shredded and formed into a crater shape (5). We have observed differences in Deacon score only among the 15 cGy subset. Further comparative performance analysis will be completed evaluating the differences in irradiation effects between male and female mice. These experimental design aspects that allot for gender-inclusivity is supportive of the diversification of future space travel mission plans. Investigating gender differences is an element under our main objective of determining radiation dose-response curves. In brief, these studies identified a space-relevant radiation dose of 15 cGy that that can be utilized for future standardized ground studies on the nervous system.

spaceflight cognition impairment↗

Intergenerational Inequities in Exposure to Climate Extremes: Young Generations Are Severely Threatened By Climate Change

Under continued global warming, extreme events such as heat waves will continue to rise in frequency, intensity, duration, and spatial extent over the next decades. Younger generations are therefore expected to face more such events across their lifetimes compared with older generations. This raises important issues of solidarity and fairness across generations that have fueled a surge of climate protests led by young people in recent years and that underpin issues of intergenerational equity raised in recent climate litigation. However, the standard scientific paradigm is to assess climate change in discrete time windows or at discrete levels of warming, a “period” approach that inhibits quantification of how much more extreme events a particular generation will experience over its lifetime compared with another. By developing a “cohort” perspective to quantify changes in lifetime exposure to climate extremes and compare across generations (see the first figure), we estimate that children born in 2020 will experience a two- to sevenfold increase in extreme events, particularly heat waves, compared with people born in 1960, under current climate policy pledges. Our results highlight a severe threat to the safety of young generations and call for drastic emission reductions to safeguard their future. Meteorological extremes, hazards, or climate change impacts are mostly studied as they evolve over time under varying emission scenarios and socioeconomic pathways. For example, applying a heat wave indicator (see table S1) to four bias-adjusted global climate models indicates that the land area annually affected by such heat waves will increase from ~15% around 2020 to ~22% by 2100 under a scenario compatible with limiting global warming to 1.5°C, and to ~46% under a scenario in line with current emission reduction pledges (see the first figure). Recent studies extended this approach, studying aspects of climate change as a function of global mean temperature (GMT) increments, highlighting the scenario-independence of several extreme event indicators but remaining, in essence, a comparison of time windows. By contrast, we performed a birth cohort analysis by combining a collection of multimodel extreme event projections with country-scale life expectancy information, gridded population data, and future global temperature trajectories from the Intergovernmental Panel on Climate Change (IPCC) Special Report on Global Warming of 1.5°C (see supplementary materials). By integrating the exposure of an average person in a country or region to extreme events across their lifetime, we encapsulate spatiotemporal changes in climate hazards, population density, cohort size, and life expectancy (see the first figure).

global warming↗

Vitrolube NPI-1220 Solid Lubricant Performance After Ultraviolet and Salt Fog Test Exposures

Vitrolube NPI-1220 is a ceramic-bonded solid lubricant produced by National Process Industries, Inc. (NPI) that uses molybdenum disulfide (MoS2) and graphite as lubricating pigments. It is applied to many space flight components, including nickel-alloy and stainless-steel components. Various applications, such as the powered nut and bolt assemblies in the international space station (ISS) (Illi, 1999), the Space Launch System (SLS) sliding bellows, and the SLS ball strut tie-rod assembly (BSTRA) use Vitrolube. No engineering data exists regarding possible Vitrolube degradation after extended exposure to coastal environments encountered by flight hardware on test stands or launch pads. Such environments include ultraviolet (UV) ray, high humidity, and salt exposures. In this study, nickel-alloy disks coated with Vitrolube by NPI, are exposed to controlled UV ray and ‘salt fog’ environments in facilities at Marshall Space Flight Center (MSFC). The exposed disks are run in tribological pin-on-disk tests to quantify any difference in coating lubricity and/or wear compared to coated disks that were not exposed to those environments.

Tribology↗

Human Exposure Analysis to EMFs from Ground Assembly of a WPT System during the Vehicle's Non-Attendance: Preprint

This paper presents assessment analysis for the human exposure to electromagnetic fields from the ground assembly (GA) of the wireless power transfer (WPT) before alignment, while the vehicle does not exist over the pad. A 25 kW WPT system from Momentum Dynamics is analyzed using finite-element software during the low power alignment operation. The same system is installed at the National Renewable Energy Laboratory (NREL) and tested at the same conditions. Good agreement is observed between the results. In addition, both results comply with standard exposure limits.

33 ADVANCED PROPULSION SYSTEMS↗

Renal effects evolution in a Chinese population after reduction of cadmium exposure in rice

Cadmium is a well-known nephrotoxic agent with extremely long biological half-time of 10-30 years in human. To investigate the evolution of cadmium-induced renal effects in the population, a number of 148 residents who lived in cadmium-polluted area were followed-up for 3 years after the reduction of cadmium exposure in rice. Urinary cadmium (UCd), {beta}{sub 2}-microglobulin (B2M) and albumin (ALB) were analyzed in 1995 and 1998, respectively. The results demonstrated that the changes of renal effects of residents depended on the levels of UCd before inflow of cadmium to human body declined. In cases where UCd were less than 10 {mu}g/g creatinine in 1995, evidence was found indicating significant decreases in proteinuria (i.e., B2M and ALB) 3 years later, whereas, in cases where the excretion of UCd exceeded 10 {mu}g/g creatinine in 1995, progression was observed. The study of dose-response relationships between UCd and B2M or ALB also showed that the cadmium-induced renal dysfunction might be reversible if UCd concentration was low-level before exposure decreasing, otherwise it might be irreversible or aggravated.

60 APPLIED LIFE SCIENCES↗

Advances in remote monitoring technology for worker safety and personnel radiation exposure reduction - 15130

This paper will present an overview of advancements made in remote monitoring technology to increase worker safety and decrease personnel radiation exposure at hazardous work sites. The presentation will discuss the use of remote technology for risk reduction to working parties. Topics covered will be the use of technology as a human performance tool in pre and post job briefings, scheduling tool for work management and communication tool between working parties and radiation protection personnel that allow for micro-managing radiation exposure. The presentation will use actual technology field experience to illustrate best practices within the commercial nuclear industry and there applicability to the waste management sector. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Penetrative Internal Oxidation from Alloy 690 Surfaces and Stress Corrosion Crack Walls during Exposure to PWR Primary Water

Analytical electron microscopy and three-dimensional atom probe tomography (ATP) examinations of surface and near-surface oxidation have been performed on Ni-30%Cr alloy 690 materials after exposure to high-temperature, simulated PWR primary water. The oxidation nanostructures have been characterized at crack walls after stress-corrosion crack growth tests and at polished surfaces of unstressed specimens for the same alloys. Localized oxidation was discovered for both crack walls and surfaces as continuous filaments (typically <10 nm in diameter) extending from the water interface into the alloy 690 matrix reaching depths of ~500 nm. These filaments consisted of discrete, plate-shaped Cr2O3 particles surrounded by a distribution of nanocrystalline, rock-salt (Ni-Cr-Fe) oxide. The oxide-containing filament depth was found to increase with exposure time and, at longer times, the filaments became very dense at the surface leaving only isolated islands of metal. Individual dislocations were oxidized in non-deformed materials, while the oxidation path appeared to be along more complex dislocation substructures in heavily deformed materials. This paper will highlight the use of high resolution scanning and transmission electron microscopy in combination with APT to better elucidate the microstructure and microchemistry of the filamentary oxidation.

Olszta, Matthew J.↗

A novel nanoparticle-based disposable electrochemical immunosensor for diagnosis of exposure to toxic organophosphorus agents

We present a novel disposable electrochemical immunosensor for highly selective and sensitive detection of organophosphorylated butyrylcholinesterase (OP-BChE), a specific biomarker for exposure to toxic organophosphorus agents. In our new approach, the zirconia nanoparticles (ZrO-2) were employed to selectively capture the OP moiety of OP-BChE adducts, and followed by quantum dot (QD)-tagged anti-BChE antibodies for amplified quantification. The captured CdSe-QD tags can be sensitively detected by stripping voltammetry using in situ bismuth-plating method. The OP agent, diisopropylfluorophosphate (DFP), was selected to prepare OP-BChE adducts in various matrices. The formation of OP-BChE adducts in plasma sample was confirmed using mass spectroscopy. The developed electrochemical immunosensor demonstrates a highly linear voltammetric response over the range of 0.1 to 30 nM OP-BChE. Moreover, the immunosensor has been successfully applied for the detection of OP-BChE adducts in the plasma samples. This novel nanoparticle-based electrochemical immunosensor thus provides an alternative way for designing simple, fast, sensitive, and cost-effective sensing platform for on-site screening/evaluating exposure to a variety of OP agents.

60 APPLIED LIFE SCIENCES↗

Atomistic‐Level Effects of Noncovalent Interactions and Crystalline Packing for Organic Material Structural Integrity upon Exposure to Gamma Radiation

Developing an atomistic understanding of ionizing radiation induced changes to organic materials is necessary for intentional design of greener and more sustainable materials for radiation shielding and detection. Cocrystals are promising for these purposes, but a detailed understanding of how the specific intermolecular interactions within the lattice upon exposure to radiation affect the structural stability of the organic crystalline material is unknown. This study evaluates atomistic-level effects of γ radiation on both single- and multicomponent organic crystalline materials and how specific noncovalent interactions and packing within the crystalline lattice enhance structural stability. Dose studies were performed on all crystalline systems and evaluated via experimental and computational methods. Changes in crystallinity were evaluated by p-XRD and free radical formation was analyzed via EPR spectroscopy. Type of intermolecular interactions and packing within the crystal lattice was delineated and related to the specific free radical species formed and the structural integrity of each material. Periodic DFT and HOMO-LUMO surface mapping calculations provided atomistic-level identifications of the most probable sites for the radicals formed upon exposure to γ radiation and relate intermolecular interactions and molecular packing within the crystalline lattice to experimental results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of exposure in steam or argon on the creep properties of Ni-based alloys: Creep properties of Ni-based alloys

Although expensive, Ni-based superalloys are of interest for the ultrasupercritical steam program because of their good creep and oxidation resistance at temperature above 700 C. However, the effect of steam oxidation on the alloy mechanical properties is unknown, and creep specimens of alloy CCA617, 740 and 230 were pre-oxidized for 2000 and 4000h in steam at 800 C before testing in air at the same temperature. Exposure in steam decreased the creep properties of alloy CCA617 compared with as fabricated material, had less of an effect on alloy 740, and did not affect alloy 230. Testing of a specimen repolished after steam exposure as well as microstructure observation indicate that the oxidation affected zone at the specimen surface is not responsible for the properties degradation. Surprisingly, a similar time anneal in an inert environment resulted in a drastic decrease of creep rupture life and an increase in the creep rate and elongation at rupture. TEM analysis revealed that the mechanical properties decrease for alloy CCA617 is related to the absence of precipitates in the grain.

36 MATERIALS SCIENCE↗

Acoustic Exposure to Turbine Operation Quantifies Risk to Bats at Commercial Wind Energy Facilities

ABSTRACT Turbine‐related bat mortality at commercial wind energy facilities may threaten populations of migratory tree‐roosting bat species in North America. Industry stakeholders and regulatory agencies alike are investigating strategies to reduce risk of population‐level consequences as the wind energy industry grows. Bats collide with turbines only when turbine rotors are spinning and curtailing turbine operation at low wind speeds can effectively reduce bat fatality rates. Nonetheless, few quantitative data exist to determine appropriate threshold wind speeds below which turbine operations should be curtailed. Carcass monitoring is labor‐intensive and does not provide information on factors linked to bat fatality rates on any scale finer than nightly. We tested whether acoustic bat data recorded at turbine nacelles could provide a more precise and sensitive measure of fatality risk to bats by analyzing acoustics, weather, turbine operation, and carcass data collected at 2 commercial wind energy facilities in West Virginia over 7 years. Each wind facility implemented several distinct curtailment treatments during our study, allowing us to compare fatality rates and acoustic bat activity across multiple operational strategies. We found that bat passes exposed to turbine operation explained close to 80% of the variation in carcass‐based estimates of bat fatality rates and accounted for significant variation in raw carcass counts per turbine and probability of finding bat carcasses during individual turbine searches. Conversely, bat activity occurring when turbines were not operating had little or no relationship to fatality rates. We also found that patterns in bat activity exposure could be predicted accurately among turbines and years. Our results demonstrate that measuring exposure of acoustic bat activity provides a quantitative basis for designing, evaluating, and adaptively managing curtailment strategies. This is an important advance towards using curtailment to reduce bat fatality rates strategically while allowing for increased generation of renewable energy. © 2021 The Authors. Wildlife Society Bulletin published by Wiley Periodicals LLC on behalf of The Wildlife Society.

17 WIND ENERGY↗

Occupational Radiation Exposure During Endovascular Aortic Repair

PurposeThe aim of the study was to evaluate the radiation exposure to operating room personnel and to assess determinants for high personal doses during endovascular aortic repair.Materials and MethodsOccupational radiation exposure was prospectively evaluated during 22 infra-renal aortic repair procedures (EVAR), 11 thoracic aortic repair procedures (TEVAR), and 11 fenestrated or branched aortic repair procedures (FEVAR). Real-time over-lead dosimeters attached to the left breast pocket measured personal doses for the first operators (FO) and second operators (SO), radiology technicians (RT), scrub nurses (SN), anesthesiologists (AN), and non-sterile nurses (NSN). Besides protective apron and thyroid collar, no additional radiation shielding was used. Procedural dose area product (DAP), iodinated contrast volume, fluoroscopy time, patient’s body weight, and C-arm angulation were documented.ResultsAverage procedural FO dose was significantly higher during FEVAR (0.34 ± 0.28 mSv) compared to EVAR (0.11 ± 0.21 mSv) and TEVAR (0.06 ± 0.05 mSv; p = 0.003). Average personnel doses were 0.17 ± 0.21 mSv (FO), 0.042 ± 0.045 mSv (SO), 0.019 ± 0.042 mSv (RT), 0.017 ± 0.031 mSv (SN), 0.006 ± 0.007 mSv (AN), and 0.004 ± 0.009 mSv (NSN). SO and AN doses were strongly correlated with FO dose (p = 0.003 and p < 0.001). There was a significant correlation between FO dose and procedural DAP (R = 0.69, p < 0.001), iodinated contrast volume (R = 0.67, p < 0.001) and left-anterior C-arm projections >60° (p = 0.02), and a weak correlation with fluoroscopy time (R = 0.40, p = 0.049).ConclusionAverage FO dose was a factor four higher than SO dose. Predictors for high personal doses are procedural DAP, iodinated contrast volume, and left-anterior C-arm projections greater than 60°.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Renal Tumor Ablation: Radiation Exposure During Cryoablation and Radiofrequency Ablation

IntroductionOnce reserved solely for non-surgical cases, percutaneous ablation is becoming an increasingly popular treatment option for a wider array of patients with small renal masses and the radiation risk needs to be better defined as this transition continues.Materials and MethodsRetrospective review of our renal tumor ablation database revealed 425 patients who underwent percutaneous ablation for treatment of 455 renal tumors over a 5-year time period. Imparted radiation dose information was reviewed for each procedure and converted to effective patient dose and skin dose using established techniques. Statistical analysis was performed with each ablative technique.ResultsFor the 331 cryoablation procedures, the mean DLP was 6987 mGycm (SD = 2861) resulting in a mean effective dose of 104.7 mSv (SD = 43.5) and the mean CTDI{sub vol} was 558 mGy (SD = 439) resulting in a mean skin dose of 563.2 mGy (SD = 344.1). For the 124 RFA procedures, the mean DLP was 3485 mGycm (SD = 1630) resulting in a mean effective dose of 50.3 mSv (SD = 24.0) and the mean CTDI{sub vol} was 232 mGy (SD = 149) resulting in a mean skin dose of 233.2 mGy (SD = 117.4). The difference in patient radiation exposure between the two renal ablation techniques was statistically significant (p < 0.001).ConclusionBoth cryoablation and RFA imparted an average skin dose that was well below the 2 Gy deterministic threshold for appreciable sequela. Renal tumor cryoablation resulted in a mean skin and effective radiation dose more than twice that for RFA. The radiation exposure for both renal tumor ablation techniques was at the high end of the medical imaging radiation dose spectrum.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fusion Imaging Reduces Radiation and Contrast Medium Exposure During Endovascular Revascularization of Iliac Steno-Occlusive Disease

Introduction: To evaluate feasibility, safety and efficacy of fusion imaging in order to guide endovascular revascularization of iliac steno-occlusive disease. Materials and Methods: Retrospectively, we identified twenty-six patients (20 male, mean age 63 ± 8y; Rutherford II-V) who underwent revascularization of a chronic total occlusion (n = 6; 23%) or severe stenosis (n = 20; 77%) of the common and/or external iliac artery. Median lesion length was 33 mm (IQR 20–60). In one group of patients (NEW; n = 11), fusion imaging with 2-D/3-D registration was used to guide revascularization. No baseline digital subtraction angiography (DSA) had been acquired in these patients. In another group of patients (OLD; n = 15), no fusion imaging had been utilized and at least one DSA run had been performed to guide the procedure. In both groups, final DSA of the treated lesions was performed. Number of DSA runs, radiation and contrast medium exposure, technical success (residual stenosis < 30%) and complications were analyzed. Results: Median DSA runs needed in OLD for guidance were n = 2 (IQR 2–3) and in NEW n = 0 (IQR 0–0; p = 0.001). Compared to OLD, median dose area product (DAP) was reduced by 17,118 mGy*cm{sup 2} (IQR 10,407–23,614; p = 0.016) if fusion imaging guidance had been used (NEW). Based on the median DAP of the final angiogram in NEW, median DAP reduction was 6007 mGy*cm{sup 2} (IQR 5012–16,105; p = 0.1). Median total contrast medium volume injected in NEW was 45 ml (IQR 30–90) and in OLD 120 ml (IQR 100–140; p = 0.001). Technical success was 100% for both groups. In 1/27 patients (3.7%) a minor complication (embolism) occurred. Conclusion: Fusion imaging proved to be feasible as well as safe and significantly reduces radiation and contrast medium exposure during endovascular revascularization of iliac steno-occlusive disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation Exposure During Transarterial Chemoembolization: Angio-CT Versus Cone-Beam CT

Introduction: Cone-beam computed tomography (CBCT) has been developed to improve reliability of many interventional radiology (IR) procedures performed with Angio system, such as transarterial chemoembolization (TACE). Angio-CT has emerged as a new imaging technology that combines a CT scanner with an Angio system in the same IR suite. The purpose of our study was to compare Angio system with CBCT capability and Angio-CT in terms of patient radiation exposure during TACE procedures. Materials and Methods: Consecutive TACE procedures performed between January 2016 and September 2017 with the two imaging modalities (Artis Zeego defining the CBCT group and Infinix-i 4D-CT defining the Angio-CT group) were reviewed. TACE and patient’s characteristics and patient radiation exposure parameters were collected. Dose-area products (DAP) and dose-length products (DLP) were converted into effective doses (ED) using conversion factors. Accuracy of tumor targeting and response was retrospectively assessed. Results: A total of 114 TACE procedures in 96 patients were included with 57 procedures in each group. The total ED in the Angio-CT group was 2.5 times lower than that in the CBCT group (median 15.4 vs. 39.2 mSv, p < 0.001). Both 2D ED and 3D ED were lower in the Angio-CT group than in the CBCT group (5.1 vs. 20 mSv, p < 0.001, and 7.4 vs. 17.9 mSv, p < 0.001, respectively). There was no significant difference neither in terms of classes of tumor targeting (p = 0.509) nor in terms of classes of tumor response (p = 0.070) between both groups. Conclusion: Angio-CT provides significant decrease in patient effective dose during TACE procedures compared to Angio system with CBCT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Organ and effective dose rate coefficients for submersion exposure in occupational settings

External dose coefficients for environmental exposure scenarios are often computed using assumption on infinite or semi-infinite radiation sources. For example, in the case of a person standing on contaminated ground, the source is assumed to be distributed at a given depth (or between various depths) and extending outwards to an essentially infinite distance. In the case of exposure to contaminated air, the person is modeled as standing within a cloud of infinite, or semi-infinite, source distribution. However, these scenarios do not mimic common workplace environments where scatter off walls and ceilings may significantly alter the energy spectrum and dose coefficients. In this study, dose rate coefficients were calculated using the International Commission on Radiological Protection (ICRP) reference voxel phantoms positioned in rooms of three sizes representing an office, laboratory, and warehouse. For each room size calculations using the reference phantoms were performed for photons, electrons, and positrons as the source particles to derive mono-energetic dose rate coefficients. Since the voxel phantoms lack the resolution to perform dose calculations at the sensitive depth for the skin, a mathematical phantom was developed and calculations were performed in each room size with the three source particle types. Coefficients for the noble gas radionuclides of ICRP Publication 107 (e.g., Ne, Ar, Kr, Xe, and Rn) were generated by folding the corresponding photon, electron, and positron emissions over the mono-energetic dose rate coefficients. Finally, results indicate that the smaller room sizes have a significant impact on the dose rate per unit air concentration compared to the semi-infinite cloud case. For example, for Kr-85 the warehouse dose rate coefficient is 7% higher than the office dose rate coefficient while it is 71% higher for Xe-133.

61 RADIATION PROTECTION AND DOSIMETRY↗

Blood Pressure Changes After Exposures Increasing Angiotensin-Converting Enzyme Activity and After Its Normalization with Dihydroquercetin in Male Wistar Rats

Changes in BP and HR were assessed after exposures increasing activity of angiotensin-converting enzyme: ionizing radiation, NO synthase inhibitor (L-NAME), and dexamethasone. Effects of dihydroquercetin and angiotensin-converting enzyme inhibitor enalapril on activity of this enzyme, BP, and HR were also evaluated under these exposures. Wistar male rats were subjected to X-ray irradiation in a dose of 2.5 Gy. Angiotensin-converting enzyme activity in the aorta sections was determined by Hip-His-Leu hydrolysis. BP and HR were recorded using a non-invasive tail-cuff method and PowerLab 8/35 software. BP and HR were not altered with the increase in activity of angiotensin-converting enzyme after irradiation. In case of prolonged (7 days) treatment with NO synthase inhibitor and dexamethasone, the increase in enzyme activity was accompanied by elevation of BP and, in the case of NO synthase inhibitor, HR reduction. Dihydroquercetin normalized the enzyme activity and lowered BP, but not to the normal level. Enalapril normalized BP, increased by NO synthase inhibitor solution intake; at the same time, the angiotensinconverting enzyme activity decreased more than 2-fold in comparison with the normal.

60 APPLIED LIFE SCIENCES↗