A Field-Deployable Wireless Data Acquisition System for Ground-Test Arrays

This paper describes the development, characterization, and deployment of a field-deployable wireless data acquisition system for ground-test arrays, applicable in noise-source localization or beamforming measurements such as those encountered during airframe noise flyover measurement tests. The system design is enabled by commercially available, low-power Internet of Things (IoT) processors and Wi-Fi communication components. Time is synchronized across the array wirelessly by leveraging the Coordinated Universal Time (UTC) time provided by the Global Positioning System (GPS). Initial laboratory characterization of the system demonstrated its ability to meet acoustic bandwidth, dynamic range, time synchronization, environmental, and battery life requirements for typical ground-test array deployments. A successful system deployment at NASA Langley was performed that included measurement of a suspended elevated static noise source, and Uncrewed Aerial System (UAS) vehicle measurements using a quadcopter operated both in hover mode and forward flight. Beamform analysis of the acquired data showed an excellent ability of the array to extract accurate sound pressure levels from the suspended source. Synchronization of the array and vehicle GPS timecodes allowed the ability to extract acoustic signatures from the UAS vehicle during hover and forward flight maneuvers over the array. These results validate that the use of a high channel count wireless array is advantageous in airframe and propulsion noise flyover test campaigns.

wireless↗

800 °C Demonstrated kHz SiC IC Electronics and Pressure Sensors as Technical Foundation for Realizing MHz DARPA HOTS Goals

The HOTS program will develop a technology for high-bandwidth, high-dynamic-range sensing at high temperature. Performance will be validated through the development and demonstration of a pressure sensor module (i.e., integrated transducer and signal-conditioning microelectronics) achieving the following performance goals: NASA Glenn has unique technology experience in extreme environment pressure sensors & IC electronics, including at 800 °C in air, providing significant risk reduction in meeting DARPA HOTS goals. Appropriate partnership and tech transfer should accelerate realization of DARPA HOTS hard technical challenges.

SiC pressure sensor electronics high temperature↗

Optical and Detector Design of the Ocean Color Instrument for the NASA Pace Mission

The Ocean Color Instrument (OCI) on NASA’s Plankton, Aerosol, Cloud, ocean Ecosystem mission is a hyperspectral imager with high SNR, precision and dynamic range, and with a very low striping artifact level in the 342-887 nm wavelength range with a spectral resolution of 5 nm in 2.5 nm steps, providing a significant technological advancement over previous ocean imagers. To achieve this, OCI is designed with specialized optical imaging and opto-electronic detection systems that push the boundaries of several state-of-the-art technologies. This paper provides an overview of these systems together with their achieved performances and discussions of their key design challenges.

Remote sensing↗

Optical and Detector Design of the Ocean Color Instrument for the NASA Pace Mission

The Ocean Color Instrument (OCI) on NASA’s Plankton, Aerosol, Cloud, ocean Ecosystem mission is a hyperspectral imager with high SNR, precision and dynamic range, and with a very low striping artifact level in the 342-887 nm wavelength range with a spectral resolution of 5 nm in 2.5 nm steps, providing a significant technological advancement over previous ocean imagers. To achieve this, OCI is designed with specialized optical imaging and opto-electronic detection systems that push the boundaries of several state-of-the-art technologies. This paper provides an overview of these systems together with their achieved performances and discussions of their key design challenges.

Remote sensing↗

RST Optical Telescope Integration and Test Preparation

The OTA for the Nancy Grace Roman Space Telescope includes the primary mirror, secondary mirror, and aft optics for guiding light into the Wide Field Instrument and the Coronagraph Instrument. The telescope is taking shape as the tested optical mirror assemblies are integrated. The assemblies have been thermal cycled to the cold temperatures for infrared operation, load tested to launch loads, vibration tested, and optically tested. Testing included launch-level vibration testing of the 2.4-meter light-weighted primary mirror assembly. In addition, the telescope control electronics (TCE) box has been fully assembled and the environmental testing of the TCE is progressing. Pictures and descriptions of the integration and test progress are provided, along with performance results measured at these levels of assemblies. Planning and test equipment preparation for the telescope thermal vacuum testing continues including plans to take advantage of the large dynamic range available with focus diversity phase retrieval and a Shack-Hartmann wavefront sensor for the gravity-sagged primary mirror.

Tony L Whitman↗

FLEET and PLIF Velocimetry Within A Mach 10 Hypersonic Air Flow

Femtosecond laser electronic excitation tagging (FLEET) and planar laser-induced fluorescence (PLIF) velocity measurements utilizing molecular tagging velocity (MTV) methods from three recent test campaigns conducted at the 31-in Mach 10 Air Tunnel at the NASA Langley Research Center are highlighted within. The FLEET measurements reported here include the first direct measurement of freestream velocity at this hypersonic wind tunnel facility. Measurement challenges were exasperated by the low gas density of the Mach 10 air freestream (~0.4% of standard temperature and pressure conditions) and even lower gas densities within the hypersonic wake of a 70-degree sphere-cone model. In addition, the hypersonic freestream and very low speed velocities in the wake also tested the measurement dynamic range. To complement the FLEET measurements in the wake of the sphere-cone model, PLIF velocimetry using seeded nitric oxide was also performed. While NO-PLIF velocimetry has been performed at this facility several times by previous researchers, the use of a 1D diffractive optical element for NO-PLIF velocimetry is reported here for the first time. The 1D DOE enabled the generation of up to 75 laser lines simultaneously and improved the spatial extent of the measurement three times compared to previous work. This enabled a wide velocity measurement plane of approximately 130 mm x 130 mm. The velocimetry methods demonstrated here are expected to improve wind tunnel characterization, provide critical data to validate CFD codes, and improve the design of flight vehicles for planetary entry.

FLEET↗

FLEET and PLIF Velocimetry Within A Mach 10 Hypersonic Air Flow

Femtosecond laser electronic excitation tagging (FLEET) and planar laser-induced fluorescence (PLIF) velocity measurements utilizing molecular tagging velocity (MTV) methods from three recent test campaigns conducted at the 31-in Mach 10 Air Tunnel at the NASA Langley Research Center are highlighted within. The FLEET measurements reported here include the first direct measurement of freestream velocity at this hypersonic wind tunnel facility. Measurement challenges were exasperated by the low gas density of the Mach 10 air freestream (~0.4% of standard temperature and pressure conditions) and even lower gas densities within the hypersonic wake of a 70-degree sphere-cone model. In addition, the hypersonic freestream and very low speed velocities in the wake also tested the measurement dynamic range. To complement the FLEET measurements in the wake of the sphere-cone model, PLIF velocimetry using seeded nitric oxide was also performed. While NO-PLIF velocimetry has been performed at this facility several times by previous researchers, the use of a 1D diffractive optical element for NO-PLIF velocimetry is reported here for the first time. The 1D DOE enabled the generation of up to 75 laser lines simultaneously and improved the spatial extent of the measurement three times compared to previous work. This enabled a wide velocity measurement plane of approximately 130 mm x 130 mm. The velocimetry methods demonstrated here are expected to improve wind tunnel characterization, provide critical data to validate CFD codes, and improve the design of flight vehicles for planetary entry.

FLEET↗

Direct Measurement of the Cosmic-Ray Helium Spectrum from 40 GeV to 250 TeV with the Calorimetric Electron Telescope on the International Space Station

We present the results of a direct measurement of the cosmic-ray helium spectrum with the CALET instrument in operation on the International Space Station since 2015. The observation period covered by this analysis spans from October 13, 2015, to April 30, 2022 (2392 days). The very wide dynamic range of CALET allowed for the collection of helium data over a large energy interval, from ∼40 GeV to ∼250 TeV, for the first time with a single instrument in low Earth orbit. The measured spectrum shows evidence of a deviation of the flux from a single power law by more than 8σ with a progressive spectral hardening from a few hundred GeV to a few tens of TeV. This result is consistent with the data reported by space instruments including PAMELA, AMS-02, and DAMPE and balloon instruments including CREAM. At higher energy we report the onset of a softening of the helium spectrum around 30 TeV (total kinetic energy). Though affected by large uncertainties in the highest energy bins, the observation of a flux reduction turns out to be consistent with the most recent results of DAMPE. A double broken power law is found to fit simultaneously both spectral features: the hardening (at lower energy) and the softening (at higher energy). A measurement of the proton to helium flux ratio in the energy range from 60 GeV=n to about 60 TeV=n is also presented, using the CALET proton flux recently updated with higher statistics.

O Adriani↗

A Vacuum-Compatible, Spectrally Tunable, Flat Panel Uniform Source for Testing Large Aperture Earth Observation Systems

Labsphere, Inc. in conjunction with NASA GSFC and Genesis Engineering Solutions Inc., has developed an innovative, vacuum compatible, calibration spectro-radiometric illumination source with a highly uniform large-area rectangular flat panel active area. This device features a uniquely shaped diffuse integration geometry to achieve high uniformity over a large active output area while maintaining a smaller and more robust overall form-factor when compared to previous designs or integrating spheres. A new liquid-cooled hybrid quartz-tungsten (QT) and light emitting diode (LED) source module has been engineered to provide direct-in-vacuum reference illumination over the full dynamic range and spectrum of the VIIRS instrument’s optical bands during pre-launch testing. The first unit has been demonstrated to meet its requirements using ambient technology and a fully-vacuum-compatible second unit is planned to allow testing in thermal vacuum (TVAC) campaigns. This technology is flexible and capable of meeting the needs of many other instruments/missions requiring this type of test/calibration capability.

Jeffrey Holt↗

Polar Firn Properties in Greenland and Antarctica and Related Effects on Microwave Brightness Temperatures

In studying the mass balance of polar ice sheets, fluctuations of firn density near the surface is a major uncertainty. In this paper, we explore these variations at locations in the Greenland Ice Sheet and at the Dome C location in Antarctica. Borehole in situ measurements, Snow Radar echoes, microwave brightness temperatures, and modelling results from the Community firn model (CFM) are used. It is shown that firn density profiles can be represented using 3 processes: “long” and “short” length scale density variations and “refrozen layers”. Consistency with this description is observed in the dynamic range of airborne 0.5-2 GHz brightness temperatures and Snow Radar echo peaks in measurements performed in Greenland in 2017. Based on these insights, a new analytical partially coherent model is implemented to explain the microwave brightness temperatures using the three scale description of the firn. Short and long scale firn processes are modelled as a 3D continuous random medium with finite vertical and horizontal correlation lengths as opposed to past 1D random layered medium descriptions. Refrozen layers are described as deterministic sheets with planar interfaces, with the number of refrozen layer interfaces determined by radar observations. Firn density and correlation length parameters used in forward modelling to match measured 0.5-2 GHz brightness temperatures in Greenland show consistency with similar parameters in CFM predictions. Model predictions also are in good agreement with multi-angle 1.4 GHz vertically and horizontally polarized brightness temperature measured by the SMOS satellite at DOME C, Antarctica. This work shows that co-located active and passive microwave measurements can be used to infer polar firn properties that can be compared with predictions of the CFM. In particular, 0.5-2 GHz brightness temperature measurements are shown to be sensitive to long scale firn density fluctuations with density standard deviations in the range 0.01-0.06 g/cm^3 and vertical correlation lengths of 6-20 cm.

Haokui Xu↗

Exploration Systems Exterior Lighting Design Guidance

Humans are returning to the Moon — this time, to stay. NASA has selected a location that maximizes line-of-sight communication with Earth, solar visibility, and access to water ice: the Lunar South Pole (LSP). While the Sun is more consistently in the lunar sky at the poles, it never rises more than 7° above the horizon in the target landing regions. This harsh lighting environment--never experienced during the Apollo missions or in human spaceflight--presents an engineering challenge: Support and protect functional vision. The human vision system, which despite having a high-dynamic range, cannot see well into bright light and cannot adapt quickly from bright to dark or vice versa. The design of helmets, windows, and lighting solutions must work in a complementary fashion to achieve a system of lighting and functional vision support that enables crews to see into darkness while their eyes are light-adapted and see in bright light while still dark-adapted that protects their eyes from injury. This report brings together information and identifies gaps related to LSP Natural environment (topology, regolith, temperature, lighting, and so forth), NASA historical experience exploring the Moon, human vision capabilities and needs, exploration operations, simulation capabilities and needs (for design verification, training, mission planning, and so forth) and existing engineering, safety, medical and performance requirements related to support human exploration.

Simulation↗

Wavefront detector

A wavefront sensor system suitable for integration into an integrated circuit light detector may provide for wave angle sensors having varying functional relationships between the wave angle and signal to provide improved dynamic range. These wave angle sensors may be combined with integrated circuit phase angle sensors for a more complete analysis of the waveform.

42 ENGINEERING↗

Optical array for high-quality imaging in harsh environments

Methods and apparatus are disclosed for producing high quality images in uncontrolled or impaired environments. In some examples of the disclosed technology, groups of cameras for high dynamic range (HDR), polarization diversity, and optional other diversity modes are arranged to concurrently image a common scene. For example, in a vehicle checkpoint application, HDR provides discernment of dark objects inside a vehicle, while polarization diversity aids in rejecting glare. Spectral diversity, infrared imaging, and active illumination can be applied for better imaging through a windshield. Preprocessed single-camera images are registered and fused. Faces or other features of interest can be detected in the fused image and identified in a library. Impairments can include weather, insufficient or interfering lighting, shadows, reflections, window glass, occlusions, or moving objects.

42 ENGINEERING↗

A Low-Power Time-to-Digital Converter for the CMS Endcap Timing Layer (ETL) Upgrade

We present the design and test results of a Time-to-Digital-Converter (TDC). The TDC will be a part of the readout ASIC, called ETROC, to read out Low-Gain Avalanche Detectors (LGADs) for the CMS Endcap Timing Layer (ETL) of High-Luminosity LHC upgrade. One of the challenges of the ETROC design is that the TDC is required to consume less than 200 W for each pixel at the nominal hit occupancy of 1%. To meet the low-power requirement, we use a single delay line for both the Time of Arrival (TOA) and the Time over Threshold (TOT) measurements without delay control. A double-strobe self-calibration scheme is used to compensate for process variation, temperature, and power supply voltage. The TDC is fabricated in a 65 nm CMOS technology. The overall performances of the TDC have been evaluated. The TOA has a bin size of 17.8 ps within its effective dynamic range of 11.6 ns. The effective measurement precision of the TOA is 5.6 ps and 9.9 ps with and without the nonlinearity correction, respectively. The TDC block consumes 97 W at the hit occupancy of 1%. Over a temperature range from 23 C to 78 C and a power supply voltage range from 1.05 V to 1.35 V (the nominal value of 1.20 V), the self-calibrated bin size of the TOA varies within 0.4%. The measured TDC performances meet the requirements except that more tests will be performed in the future to verify that the TDC complies with the radiation-tolerance specifications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Sub-Threshold Low-Power Integrated Bandpass Filter for Highly-Integrated Spectrum Analyzers

Low-power analog filter banks provide frequency analysis with minimal power and space requirements, making them viable solutions for integrated remote audio- and vibration-sensing applications. Compared with their digital counterparts, analog filter banks are better suited to achieve the lower power consumption necessary for IoT applications. In this work, the design and implementation of a sub-threshold complementary metal-oxide semiconductor (CMOS) integrated low-power tunable bandpass filter channel for signal spectrum analysis and signal discrimination is presented, including performance improvements to stability and precise matching between filter stages. The 8 th -order filter channel achieves an effective Q-factor of 4.5 and dynamic range of 60 dB, has an operational frequency range from 2 kHz to 100 kHz, and consumes 256 µW nominally at the highest center frequency. An integrated analog Gm-C filter topology is selected for this application. Functionally, the high-Q bandpass filter transfer function is implemented via four cascaded 2 nd -order filter cells and is fabricated in 130-nm 1.2-V CMOS technology, making it suitable for use in monolithic integrated spectral analysis (MISA) applications.

Long, Gavin↗

Final Report for Grant

This is the final report for this project. The major objectives were to develop full models and standard cells of CMOS silicon photomultipliers (SiPM) for neutron detection applications. Specifically, the research seeks to replace photomultiplier tubes, used in neutron detection applications, with SiPMs containing integrated readout electronics fabricated in standard CMOS processes. The detectors improve on the detection efficiency, readout speed, resolution (sensitivity), and spatial resolution of current systems. In particular, this work involved collaboration with the instrument and detector group at ORNL who build detectors based on discrete commercially available PMTs and SiPMs. The SiPM detectors developed in this work are based on Perimeter Gated Single Photon Avalanche Diodes (PGSPAD). These devices have tunable breakdown voltage which affects other performance characteristics of the detectors. The ability of the detectors to have integrated readout and tune the noise floor and dynamic range in addition to offering a method for non-uniformity compensation in a compact form significantly impacts the imaging research field and includes the nuclear sciences field, circuits and systems field in addition to varied fields such as geography and biology/medicine.

42 ENGINEERING↗

High-efficiency transmission-mode diamond scintillator for quantitative characterization of X-ray beams

The luminance of a transmission mode X-ray scintillator diamond plate is dominated by induced defect centers having an excited state lifetime less than 10 msec, and in embodiments less than 1 msec, 100 usec, 10 used, 1 used, 100 nsec, or even 50 nsec, thereby providing enhanced X-ray luminance response and an X-ray flux dynamic range that is linear with X-ray flux on a log-log scale over at least three orders of magnitude. The diamond plate can be a single crystal having a dislocation density of less than 104 per square centimeter, and having surfaces that are ion milled instead of mechanically polished. The defect centers can be SiV centers induced by silicon doping during CVD diamond formation, and/or NV0 centers formed by nitrogen doping followed by applying electron beam irradiation of the diamond plate and annealing.

Antipov, Sergey↗

Ultra-broadband voltage-controlled oscillator linearization for frequency modulated continuous wave MMW imaging systems

Millimeter-wave (MMW) imaging systems require high resolution and spurious free dynamic range (SFDR) to produce images with low artifacts. In these systems, lateral resolution is determined by the center frequency and the ratio of the aperture size to the distance to the target. The downrange resolution is determined by the system bandwidth; for very fine downrange resolution of a target, or material layers/discontinuities, the bandwidth must be very broad. Additionally, the response over the bandwidth must be measured very rapidly to support high speed acquisition over large apertures. A voltage-controlled oscillator (VCO) is a standard means of generating the ultra-broadband frequency chirp. This paper investigates the use of a broadband VCO for use in MMW imaging systems, a linear-phase calibration technique, and digital-to-analog converter (DAC) parameter considerations for controlling the VCO.

FMCW, homodyne, VCO, DAC, difference frequency, SF↗