Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Design of a diagnostic residual gas analyzer for the ITER divertor

One of the ITER diagnostics having reached an advanced design stage is a diagnostic RGA for the divertor, i.e. residual gas analysis system for the ITER divertor, which is intended to sample the divertor pumping duct region during the plasma pulse and to have a response time compatible with plasma particle and impurity lifetimes in the divertor region. Main emphasis is placed on helium (He) concentration in the ducts, as well as the relative concentration between the hydrogen isotopes (H2, D2, T2). Measurement of the concentration of radiative gases, such as neon (Ne) and nitrogen (N2), is also intended. Numerical modeling of the gas flow from the sampled region to the cluster of analysis sensors, through a long (~8m long, ~110mm diameter) sampling pipe terminating in a pressure reducing orifice, confirm that the desired response time (~1s for He or D2) is achieved with the present design.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Longitudinal Beam Diagnostics for the ILC Injectors and Bunch Compressors

We present a diagnostics suite and analyze techniques for setting up the longitudinal beam dynamics in ILC e⁻ injectors and e⁺ and e⁻ bunch compressors. Techniques to measure the first order moments and recover the first order longitudinal transfer map of the injector's intricate bunching scheme are presented. Coherent transition radiation diagnostics needed to measure and monitor the bunch length downstream of the ~5 GeV bunch compressor are investigated using a vector diffraction model.

43 PARTICLE ACCELERATORS↗

Laboratory-based validation of the baseline sensors of the ITER diagnostic residual gas analyzer

The divertor-specific ITER Diagnostic Residual Gas Analyzer (DRGA) will provide essential information relating to DT fusion plasma performance. This includes pulse-resolving measurements of the fuel isotopic mix reaching the pumping ducts, as well as the concentration of the helium generated as the ash of the fusion reaction. In the present baseline design, the cluster of sensors attached to this diagnostic's differentially pumped analysis chamber assembly includes a radiation compatible version of a commercial quadrupole mass spectrometer, as well as an optical gas analyzer using a plasma-based light excitation source. This paper reports on a laboratory study intended to validate the performance of this sensor cluster, with emphasis on the detection limit of the isotopic measurement. This validation study was carried out in a laboratory set-up that closely prototyped the analysis chamber assembly configuration of the baseline design. This includes an ITER-specific placement of the optical gas measurement downstream from the first turbine of the chamber's turbo-molecular pump to provide sufficient light emission while preserving the gas dynamics conditions that allow for \textasciitilde 1 s response time from the sensor cluster [1].

Biewer, Theodore↗

"Ion" B-Dot and Faraday Cup Results Located Inside The Cathode Knob Of The Self Magnetic Pinch (Smp) Diode (A New Diagnostic For Diode Behavior?)

This paper describes our effort to measure the back-streaming ions emitted from the target x-ray convertor and thus estimate the ion contribution to the A-K gap bipolar current flow. Knowing the ion contribution is quite important in order to calculate the expected x-ray dose and compare it with the actual measurements. Our plans were first to measure the total ion current using B-dot monitors, Rogowski coils, and Faraday cups and then to utilize filtered Faraday cups and time of flight techniques to identify and measure the various ionic species. The kinetic energy (velocities) of the ions should help evaluate the actual voltage applied at the anode-cathode (A-K) gap. LSP simulations found that the most prominent ions are protons and carbon single plus (C+). For an 8-MV A-K voltage, the estimated proton current back-streaming through an 1 cm in diameter hollow cathode tip was on the average 3 kA and the carbon current 0.7 kA. Since only a small fraction of the ions will make it through the cylindrical aperture, the corresponding total currents were calculated to be respectively 25kA for proton and 7 kA for carbon ions, a quite substantial contribution to the total bipolar beam current. Hence, approximately only 10% of the total back-streaming ionic currents could make it through the hollow cathode tip aperture. Unfortunately the diagnostic cables connecting the Faraday cup and the B-dot monitors to the screen room scopes experienced a large amount of charge pick-up that obliterated our effort to directly measure those relatively small currents. However, we succeeded in measuring those currents indirectly with activation techniques [Contribution of the back-streaming ions to the self-magnetic pinch (SMP) diode Current., M. G. Mazarakis, M. G. Mazarakis, M. E. Cuneo, S. D. Fournier, M. D. Johnston, M. L. Kiefer, J. J. Leckbee, D. S. Nielsen, B.V.Oliver, M. E. Sceiford, S. C. Simpson, T. J. Renk, C. L. Ruiz, T. J. Webb, and D. Ziska. Subitted for publication.]. In the following sections we present some typical cable pick-up results and also our efforts to verify that the observed “current” scope traces were indeed not ion currents but instead cable charge pic-up. Interestingly enough we also discovered that the appearance of those “currents” are in synchronism with the A-K gap impedance variation (decrease) and the MITL sheath current re-trapping. Hence those B-dots or Faraday cups could be utilized as diode behavior diagnostics.

Mazarakis, Michael G.↗

Fluorescence intensity monitors as intensity and beam-position diagnostics for X-ray free-electron lasers

For LCLS-II, a fluorescence intensity monitor for the non-invasive, pulse-by-pulse normalization of experiments has been developed. A prototype diagnostic was constructed with a microchannel plate assembly and two photodiodes. The diagnostic was then installed in the LCLS SXR instrument Kirkpatrick–Baez mirror chamber with the detectors located above the vertically reflecting mirror. The linearity, noise and position sensitivity of the detectors have been characterized. The photodiode responsivity is suitable for high pulse energies. The microchannel plate detector shows sufficient responsivity over a wide range of pulse energies. The relative signal from the two photodiodes provides a sensitive measure of the X-ray beam position. The fluorescence intensity monitor provides intensity normalization while being compatible with high incident power, a 0.93 MHz repetition rate and ultra-high vacuum.

Heimann, Philip↗

Single-Shot Diagnostics of Microbunched Electrons in Laser-Driven Plasma Accelerators and Free-Electron Lasers

aThe need for single-shot diagnostics of the periodic longitudinal density modulation of relativistic electrons at the resonant wavelength (microbunching) in a free-electron laser (FEL) or at broadband visible wavelengths as in a laser-driven plasma accelerator (LPA) has been reaffirmed. In the self-amplified spontaneous emission (SASE) FEL case, statistical fluctuations in the microbunching occur in the startup- from-noise process. In the LPA, the plasma itself is chaotic and varies shot to shot. Fortunately, we have shown that coherent optical transition radiation (COTR) techniques, can assess beam size, divergence, spectral evolution, and z-dependent gain (100,000) of microbunched electrons in a past SASE FEL experiment at 530 nm*. Recently, the application to LPAs has been demonstrated with single-shot near-field (NF) and far-field (FF) COTR imaging done at the exit of an LPA for the first time**. In this case few-micron beam sizes and extensive fringes due to su b-mrad divergences were measured based on point-spread-function effects and an analytical model for COTR interferometry (COTRI), respectively. A new COTR-based diagnostics application to pre-bunched electron beams formed by co-propagating a laser pulse and the electron pulse in a short undulator (modulator) is also described.

43 PARTICLE ACCELERATORS↗

Emerging Diagnostic Developments from the NNSS

Presentation describes diagnostic capabilities at Nevada National Security Site and affiliated sites, providing overview of optical velocimetry diagnostic technologies, imager technologies, dynamic temperature measurement technologies, broad band laser ranging technologies, and others.

36 MATERIALS SCIENCE↗

Feasibility of Diagnostics Undulator Studies at ASTA

The Advanced Superconducting Test Accelerator (ASTA) facility is currently under construction at Fermilab. With a 1-ms macropulse composed of up to 3000 micropulses and with beam energies projected from 45 to 800 MeV, the need for non-intercepting diagnostics for beam size, position, energy, and bunch length is clear. In addition to the rf BPMs, optical synchrotron radiation (OSR), and optical diffraction radiation (ODR) techniques already planned, we propose the use of undulator radiation from a dedicated device for diagnostics. with a nominal period of 4-5 cm, a tunable field parameter K, and a length of several meters. The feasibility of extending such techniques in the visible regime at a beam energy of 125 MeV into the UV and VUV regimes with beam energies of 250 and 500 MeV will be presented.

43 PARTICLE ACCELERATORS↗

Diagnostics for Linac Optimization With Machine Learning

The Fermilab Linac delivers 400 MeV H- beam to the rest of the accelerator chain. Providing stable intensity, energy, and emittance is key since it directly affects downstream machines. To counter fluctuations of Linac output due to various effects to be described below we are working on implementing dynamic longitudinal parameter optimization based on Machine Learning (ML). As inputs for the ML model, signals from beam diagnostics have to be well understood and reliable. In this paper we discuss the status and plans for ML-based optimization as well as preliminary results of diagnostics studies.

43 PARTICLE ACCELERATORS↗

High-Performance Accelerator Modeling: Toward Improving Controls and Diagnostics for High-Brightness Beams in Experiment

One of the main charges of beam physics is to improve the overall beam quality delivered to experiments and applications, which is generally quantified by the beam brightness. High brightness beams have numerous applications, including x-ray free electron lasers and ultrafast electron diffraction (UED). To these ends, this thesis details efforts to use high-performance models --- high-fidelity models that execute quickly --- for controls and diagnostics. To demonstrate the generality of these techniques, this thesis focuses on three of the most successful photoinjector designs currently used worldwide: the UCLA/SLAC/BNL-type high-gradient S-band gun, the continuous-wave high-repetition rate VHF APEX gun and the L-band DESY-PITZ-type gun. Work will be shown from Pegasus (UCLA), HiRES (LBNL) and FAST (FNAL).Specifically, data-driven models for online virtual diagnostics are presented, in this case, in the context of UED at HiRES, leading to a temporal resolution improvement. Methods for improving the fidelity of physics-based models are discussed, with examples at HiRES, Pegasus and FAST. Markov-chain Monte Carlo analysis is applied to match simulations, in the context of photocathode studies at HiRES and Pegasus. Lastly, the augmentation of online model-based predictions with model-independent optimization is explored in a fluctuating environment at Pegasus and HiRES. A central theme of this dissertation is working with parameter fluctuations when modeling an accelerator beamline. Long-term drifts and shot-to-shot jitter exist in every accelerator to a varying degree and therefore play an important role in every chapter of this dissertation. This thesis attempts to address the issues associated with these fluctuations when trying to develop faithful model representations of the system.

43 PARTICLE ACCELERATORS↗

Prelude to Simulation Diagnostics in MOOSE: Diagnosing Meshes

As finite element simulations increase in complexity, so does the need for high quality meshes. Without proper diagnostics, issues pertaining to poor mesh quality or improper mesh construction may go undetected, causing simulations to fail unexpectedly. This paper details the new mesh diagnostic system available in MOOSE, which provides users with the tools to inspect mesh quality for both externally and internally generated meshes. This system can detect issues arising from element volume size, non-conformal elements, intersecting edges, missing sidesets, as well as other common mesh issues. As meshes increase in size and complexity, such issues become more difficult to diagnose through visual inspection alone.

99 - GENERAL AND MISCELLANEOUS↗

Beam Diagnostic by Outside Beam Chamber Fields

Fields induced by a beam and penetrated outside the beam pipe can be used for a beam diagnostic. Wires placed in longitudinal slots in the outside wall of the beam pipe can work as a beam pickup. This has very small beam-coupling impedance and avoids complications of having a feed-through. The signal can be reasonably high at low frequencies. We calculate the beam-coupling impedance due to a long longitudinal slot in the resistive wall and the signal induced in a wire placed in such a slot and shielded by a thin screen from the beam. We present a field waveform at the outer side of a beam pipe, obtained as a result of calculations and measurements. Such kind of diagnostic can be used in storage rings, synchrotron light sources, and free electron lasers, like LINAC coherent light source.

43 PARTICLE ACCELERATORS↗

Radiochemistry diagnostics for the National Ignition Facility

Radiochemistry-based techniques will be an important complement to x-ray implosion diagnostics. Simulations demonstrate the value of alpha-induced or deuteron-induced reactions as a direct measurement of static mix contamination in DT-filled ignition capsules. In this proceedings we examine to what extent neutron-induced reactions might be highly correlated with the energetically down-scattered neutron fraction which is, in turn, related to the critical quantity of fuel areal density, {rho}R. Although alpha and deuteron reactions are highly suppressed in HT/D-filled capsules, neutron-induced reactions produce robust abundances and 2% measurements of the relevant radiological ratios is achievable. We conclude that radiochemical data are strongly correlated with the down-scattered fraction and fuel areal density. Unknown physics, primarily uncertainties in the direct T-T fusion neutron cross section and, to a lesser extent, various radiochemical production cross sections are important but calibration shots can be used to reduce these errors. The primary advantage of radiochemistry remains - it is the only technique that samples down-scattered neutrons from the entire capsule during the burn. In particular radiochemistry correlated with other diagnostics can be used to minimize experimental uncertainties and thus maximize gain.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Optical diagnostics integrated with laser spark delivery system

A spark delivery system for generating a spark using a laser beam is provided, and includes a laser light source and a laser delivery assembly. The laser delivery assembly includes a hollow fiber and a launch assembly comprising launch focusing optics to input the laser beam in the hollow fiber. The laser delivery assembly further includes exit focusing optics that demagnify an exit beam of laser light from the hollow fiber, thereby increasing the intensity of the laser beam and creating a spark. Other embodiments use a fiber laser to generate a spark. Embodiments of the present invention may be used to create a spark in an engine. Yet other embodiments include collecting light from the spark or a flame resulting from the spark and conveying the light for diagnostics. Methods of using the spark delivery systems and diagnostic systems are provided.

47 OTHER INSTRUMENTATION↗

Modeling and Measurement Constraints in Fault Diagnostics for HVAC Systems

Many studies have shown that energy savings of five to fifteen percent are achievable in commercial buildings by detecting and correcting building faults, and optimizing building control systems. However, in spite of good progress in developing tools for determining HVAC diagnostics, methods to detect faults in HVAC systems are still generally undeveloped. Most approaches use numerical filtering or parameter estimation methods to compare data from energy meters and building sensors to predictions from mathematical or statistical models. They are effective when models are relatively accurate and data contain few errors. In this paper, we address the case where models are imperfect and data are variable, uncertain, and can contain error. We apply a Bayesian updating approach that is systematic in managing and accounting for most forms of model and data errors. The proposed method uses both knowledge of first principle modeling and empirical results to analyze the system performance within the boundaries defined by practical constraints. We demonstrate the approach by detecting faults in commercial building air handling units. We find that the limitations that exist in air handling unit diagnostics due to practical constraints can generally be effectively addressed through the proposed approach.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Implementation of a Doppler-Free Saturation Spectroscopy (DFSS) Diagnostic for Helicon Wave Electric Field Vector Measurement in Edge Plasma in DIII-D

A laser-based technique known as Doppler-free saturation spectroscopy (DFSS) has been designed, fabricated, and installed on the DIII-D National Fusion Facility to measure the helicon wave electric field vector in the edge plasma. These experimental measurements quantify phenomena resulting in decreased current drive efficiency due to wave/edge plasma interactions. This implementation of DFSS on DIII-D is the first of its kind on a tokamak and thus presents unique engineering challenges, including integration of the system onto an existing multidiagnostic port flange without impacts to system serviceability, as well as maintaining precise laser alignment over a 2-m distance during disruptions and thermal drift of the vessel. Further, these challenges were resolved using innovative design approaches such as a novel decoupled shutter system to facilitate serviceability of the in-vessel mirror assemblies without the need for personnel vessel entry, as well as an ex-vessel piezo-mirror-based optical system for laser beam shaping and real-time steering of the measurement location. The solutions to these engineering challenges were demonstrated during the successful installation and operation of these diagnostic components during the 2022 DIII-D vent and subsequent experimental campaign.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A diagnostic microdosing approach to investigate platinum sensitivity in non-small cell lung cancer

The platinum-based drugs cisplatin, carboplatin and oxaliplatin are often used for chemotherapy, but drug resistance is common. The prediction of resistance to these drugs via genomics is a challenging problem since hundreds of genes are involved. A possible alternative is to use mass spectrometry to determine the propensity for cells to form drug-DNA adducts—the pharmacodynamic drug-target complex for this class of drugs. In this paper, the feasibility of predictive diagnostic microdosing was assessed in non-small cell lung cancer (NSCLC) cell culture and a pilot clinical trial. Accelerator mass spectrometry (AMS) was used to quantify [ 14 C]carboplatin-DNA monoadduct levels in the cell lines induced by microdoses and therapeutic doses of carboplatin, followed by correlation with carboplatin IC 50 values for each cell line. The adduct levels in cell culture experiments were linearly proportional to dose (R 2 = 0.95, p < 0.0001) and correlated with IC 50 across all cell lines for microdose and therapeutically relevant carboplatin concentrations (p = 0.02 and p = 0.01, respectively). A pilot microdosing clinical trial was conducted to define protocols and gather preliminary data. Plasma pharmacokinetics (PK) and [ 14 C]carboplatin-DNA adducts in white blood cells and tumor tissues from six NSCLC patients were quantified via AMS. The blood plasma half-life of [ 14 C]carboplatin administered as a microdose was consistent with the known PK of therapeutic dosing. The optimal [ 14 C]carboplatin formulation for the microdose was 10 7 dpm/kg of body weight and 1% of the therapeutic dose for the total mass of carboplatin. No microdose-associated toxicity was observed in the patients. Finally, additional accruals are required to significantly correlate adduct levels with response.

60 APPLIED LIFE SCIENCES↗

Diagnostics of Fast Electrons within Castor Tokamak by Means of a Modified Cherenkov-Type Probe

The paper reports on experimental studies performed within the CASTOR tokamak, which was operated at IPP in Prague, Czech Republic, during the last experimental campaign carried out in autumn 2006. The main aim was to implement a new diagnostic technique for measurements of energetic (>80 keV) electrons within the tokamak edge plasma region. The technique was based on the use of a Cherenkov-type probe similar to the first prototype detector, which was tested during the previous experiments with the CASTOR device. In particular, the distributions of fast electrons in a standard scenario at different values of plasma current I{sub p}, and toroidal magnetic field B{sub T} are determined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗