Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detection and Characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Characterization of the X-ARAPUCA Systems' Response for SBND's Light Detection

X-ARAPUCA waveform data, collected at a test stand at the Noble Liquid Test Facility (NLTF) and the Short Baseline Near Detector (SBND), were analyzed via python scripts. For the ARARA system, various distributions and correlations were studied, including the area and amplitude distributions of the waveform peaks for identifying single photoelectron peaks, as well as characterizing the behavior of the baseline artifact. The ARARA system is being studied in order to be implemented into SBND, just as the APSAIA X-ARAPUCAs have been.

Novotny, Andrew [U. Illinois, Chicago]↗

Applying Waveform Correlation to Reduce Seismic Analyst Workload Due to Repeating Mining Blasts

Agencies that monitor for underground nuclear tests are interested in techniques that automatically characterize mining blasts to reduce the human analyst effort required to produce high–quality event bulletins. Waveform correlation is effective in finding similar waveforms from repeating seismic events, including mining blasts. We report the results of an experiment to detect and identify mining blasts for two regions, Wyoming (U.S.A.) and Scandinavia, using waveform templates recorded by multiple International Monitoring System stations of the Preparatory Commission for the Comprehensive Nuclear–Test–Ban Treaty Organization (CTBTO PrepCom) for up to 10 yr prior to the time of interest. We discuss approaches for template selection, threshold setting, and event detection that are specialized for characterizing mining blasts using a sparse, global network. We apply the approaches to one week of data for each of the two regions to evaluate the potential for establishing a set of standards for waveform correlation processing of mining blasts that can be generally applied to operational monitoring systems with a sparse network. Here, we compare candidate events detected with our processing methods to the Reviewed Event Bulletin of the International Data Centre to assess potential reduction in analyst workload.

58 GEOSCIENCES↗

Characterization of lateral amorphous selenium photodetectors for low-photon and VUV detection at cryogenic temperatures

The performance of amorphous selenium (a-Se) as a cryogenic photodetector material is evaluated through a series of experiments using laterally structured devices operated in a custom optical test stand. These studies investigate the response of a-Se detectors to low-photon fluxes at high electric fields near avalanche conditions, the linearity of the photoconductive response over a wide dynamic range and the direct detection of narrowband 130 nm vacuum ultraviolet (VUV) illumination. At 87 K, matched-filter analysis shows reliable single-shot detection with efficiencies ≥80% and area under the curve (AUC) ≥ 0.85 using as few as ∼ 6800 incident 401 nm photons, corresponding to ∼ 3400 photons within field-active regions after accounting for geometric constraints. Measurements are performed at cryogenic temperatures using calibrated photon fluxes derived from a silicon photomultiplier reference and a characterized optical filter stack. Additional experiments using a tellurium-doped a-Se (a-SeTe) device explore the material's behavior under identical test conditions and demonstrate that avalanche is achievable in a-SeTe at cryogenic temperatures. The results demonstrate reproducible low-noise operation, VUV sensitivity and field-dependent gain behavior in a lateral a-Se architecture, representing the first reported observation of avalanche multiplication in laterally structured a-Se and a-SeTe devices at cryogenic temperatures. These findings support the potential integration of laterally structured a-Se devices into next-generation pixelated liquid-argon time projection chambers (TPCs) requiring scalable, high-field-compatible photon detection systems.

Amorphous selenium↗

Radiological mapping of facilities under dismantling process by digital autoradiography - 15230

because safety standards have changed. In that context, radioactive waste management is a challenging task faced by existing nuclear power countries. Therefore, characterization is essential to classify wastes and to reduce costs. In many facilities, after the removal of glove boxes, fume cupboards and so on, the remaining materials on the floor, walls, and ceiling must be characterized. Gamma emitters can be detected remotely by commercial devices. However, analytical techniques to detect alpha and beta emitters in situ are generally not well suited for large area investigations. The Digital Autoradiography (DA) technique, initially dedicated to research in biology, was re-routed for final state characterization before facility demolition. It is based on the exposure of radio-sensitive phosphor screens on the materials to characterize. Phosphor screens, after a scanning process, provide a picture of the radioactivity, and are reusable several tens of times. This analytical technique is sensitive to all types of radioactivity, requires neither operators nor electricity during acquisition process, and produces only very few wastes. DA has already been tested in different facilities to obtain semi-quantitative values of C-14 and H-3 activities. Large amount of data gathered to cover the whole surface to be characterized. A Geographic Information System (GIS) associated with geostatistical method has been used to provide Radiological Mapping. This method to interpret Digital Autoradiography results has been proved very efficient to prepare remediation project. (authors)

54 ENVIRONMENTAL SCIENCES↗

Characterization of the X-ARAPUCA systems' response for SBND's light detection

X-ARAPUCA waveform data, collected at a test stand at the Noble Liquid Test Facility (NLTF) and the Short Baseline Near Detector (SBND), were analyzed via python scripts. For the ARARA system, various distributions and correlations were studied, including the area and amplitude distributions of the waveform peaks for identifying single photoelectron peaks, which was able to be accomplished. The behavior of the baseline artifact was also characterized, which appeared only at high voltages/bright events, and separates further from the prompt peak as the voltage/brightness increases. The ARARA system is being studied in order to be implemented into SBND, just as the APSAIA X-ARAPUCAs have been.

Novotny, Andrew [Fermilab]↗

Generic Sensor Modeling Using Pulse Method

Recent development of high spatial resolution satellites such as IKONOS, Quickbird and Orbview enable observation of the Earth's surface with sub-meter resolution. Compared to the 30 meter resolution of Landsat 5 TM, the amount of information in the output image was dramatically increased. In this era of high spatial resolution, the estimation of spatial quality of images is gaining attention. Historically, the Modulation Transfer Function (MTF) concept has been used to estimate an imaging system's spatial quality. Sometimes classified by target shapes, various methods were developed in laboratory environment utilizing sinusoidal inputs, periodic bar patterns and narrow slits. On-orbit sensor MTF estimation was performed on 30-meter GSD Landsat4 Thematic Mapper (TM) data from the bridge pulse target as a pulse input . Because of a high resolution sensor s small Ground Sampling Distance (GSD), reasonably sized man-made edge, pulse, and impulse targets can be deployed on a uniform grassy area with accurate control of ground targets using tarps and convex mirrors. All the previous work cited calculated MTF without testing the MTF estimator's performance. In previous report, a numerical generic sensor model had been developed to simulate and improve the performance of on-orbit MTF estimating techniques. Results from the previous sensor modeling report that have been incorporated into standard MTF estimation work include Fermi edge detection and the newly developed 4th order modified Savitzky-Golay (MSG) interpolation technique. Noise sensitivity had been studied by performing simulations on known noise sources and a sensor model. Extensive investigation was done to characterize multi-resolution ground noise. Finally, angle simulation was tested by using synthetic pulse targets with angles from 2 to 15 degrees, several brightness levels, and different noise levels from both ground targets and imaging system. As a continuing research activity using the developed sensor model, this report was dedicated to MTF estimation via pulse input method characterization using the Fermi edge detection and 4th order MSG interpolation method. The relationship between pulse width and MTF value at Nyquist was studied including error detection and correction schemes. Pulse target angle sensitivity was studied by using synthetic targets angled from 2 to 12 degrees. In this report, from the ground and system noise simulation, a minimum SNR value was suggested for a stable MTF value at Nyquist for the pulse method. Target width error detection and adjustment technique based on a smooth transition of MTF profile is presented, which is specifically applicable only to the pulse method with 3 pixel wide targets.

Helder, Dennis L.↗

Characterization of resonant tunneling diodes for microwave and millimeter-wave detection

The authors report on the direct detection capabilities of resonant tunneling diodes in the 10-100 GHz range. An open circuit voltage sensitivity of 1750 mV/mW (in Ka-band) was measured. This is higher than the sensitivity of comparatively based commercially available solid-state detectors. The detector properties are a strong function of diode bias and the measured tangential signal sensitivity (-32 dBm at Ka-band with 1-MHz bandwidth) and the dynamic range (25 dB) of the diode are smaller compared to other solid-state detectors.

Mehdi, I.↗

Surface Acoustic Wave Sensors for Refrigerant Leak Detection: Compact, Inexpensive, Selective and Sensitive Sensors

Pacific Northwest National Laboratory (PNNL), in collaboration with Parker and Hannifin, is developing a compact, inexpensive, and highly sensitive and selective surface acoustic wave sensor coated with fluorophillic sorbent for detecting fluorocarbon leaks from HVAC systems. Having a highly effective sorbent sensitive to fluorocarbon refrigerant vapors provides a means to develop a sensing device for leak detection. Surface acoustic wave (SAW) sensors with a gas sensing film deposited between the delay lines or on the interdigital transducer have been used to detect gas and vapor molecules in harsh environments with high sensitivity. As part of this project, PNNL screened several sorbent materials that are shown to be selective towards fluorocarbon refrigerant (R32) molecule. The identified sorbent materials were synthesized, characterized, and tested towards R32 using various spectroscopic technique. Next, the sorbent material was coated on a SAW sensor as a thin film using vapor deposition and drop coating methods. The coated thin film was further characterized and tested towards the detection of pure R32 and R32 in ambient air at room temperature to demonstrate the SAW response towards R32 in presence of other competing gases and vapors in air.

42 ENGINEERING↗

Characterization of Lateral Amorphous Selenium Photodetectors for Low-Photon and VUV Detection at Cryogenic Temperatures

The performance of amorphous selenium (a-Se) as a cryogenic photodetector material is evaluated through a series of experiments using laterally structured devices operated in a custom optical test stand. These studies investigate the response of a-Se detectors to low-photon fluxes at high electric fields near avalanche conditions, the linearity of the photoconductive response over a wide dynamic range and the direct detection of narrowband 130 nm vacuum ultraviolet (VUV) illumination. At 87 K, matched-filter analysis shows reliable single-shot detection with efficiencies greater than or equal to 80 percent and area under the curve (AUC) greater than or equal to 0.85 using as few as approximately 6800 incident 401 nm photons, corresponding to approximately 3400 photons within field-active regions after accounting for geometric constraints. Measurements are performed at cryogenic temperatures using calibrated photon fluxes derived from a silicon photomultiplier reference and a characterized optical filter stack. Additional experiments using a tellurium-doped a-Se (a-SeTe) device explore the material's behavior under identical test conditions and demonstrate that avalanche is achievable in a-SeTe at cryogenic temperatures. The results demonstrate reproducible low-noise operation, VUV sensitivity and field-dependent gain behavior in a lateral a-Se architecture, representing the first reported observation of avalanche multiplication in laterally structured a-Se and a-SeTe devices at cryogenic temperatures. These findings support the potential integration of laterally structured a-Se devices into next-generation pixelated liquid-argon time projection chambers (TPCs) requiring scalable, high-field-compatible photon detection systems.

FOS: Physical sciences↗

On the implementation and performance of single and double differential detection schemes

A variety of schemes for performing double differential detection of MPSK signals in environments characterized by frequency offset are discussed. Comparisons of their implementation and performance are made with single differential detection systems. The application of the idea of multiple symbol detection in double differential detection schemes is addressed.

Simon, Marvin K.↗

Bayesian approach to the detection problem in gravitational wave astronomy

The analysis of data from gravitational wave detectors can be divided into three phases: search, characterization, and evaluation. The evaluation of the detection--determining whether a candidate event is astrophysical in origin or some artifact created by instrument noise--is a crucial step in the analysis. The ongoing analyses of data from ground-based detectors employ a frequentist approach to the detection problem. A detection statistic is chosen, for which background levels and detection efficiencies are estimated from Monte Carlo studies. This approach frames the detection problem in terms of an infinite collection of trials, with the actual measurement corresponding to some realization of this hypothetical set. Here we explore an alternative, Bayesian approach to the detection problem, that considers prior information and the actual data in hand. Our particular focus is on the computational techniques used to implement the Bayesian analysis. We find that the parallel tempered Markov chain Monte Carlo (PTMCMC) algorithm is able to address all three phases of the analysis in a coherent framework. The signals are found by locating the posterior modes, the model parameters are characterized by mapping out the joint posterior distribution, and finally, the model evidence is computed by thermodynamic integration. As a demonstration, we consider the detection problem of selecting between models describing the data as instrument noise, or instrument noise plus the signal from a single compact galactic binary. The evidence ratios, or Bayes factors, computed by the PTMCMC algorithm are found to be in close agreement with those computed using a reversible jump Markov chain Monte Carlo algorithm.

79 ASTRONOMY AND ASTROPHYSICS↗

A water-based fast integrated mobility spectrometer (WFIMS) with enhanced dynamic size range

We developed a water-based fast integrated mobility spectrometer (WFIMS) with enhanced dynamic size range. The WFIMS builds on two established technologies: the fast integrated mobility spectrometer and laminar flow water-based condensation methodology. Inside WFIMS, particles of differing electrical mobility are separated in a drift tube and subsequently enlarged through water condensation. Particle size and concentration are measured via digital imaging at a frame rate of 10 Hz. When we measure particles of different mobilities simultaneously, the WFIMS resolves particle diameters ranging from 8 to 580 nm within 1 s or less. The performance of WFIMS was characterized with differential mobility analyzer (DMA) classified (NH 4 ) 2 SO 2 particles with diameters ranging from 8 to 265 nm. The mean particle diameters measured by WFIMS were found to be in excellent agreement with DMA centroid diameters. Furthermore, detection efficiency of WFIMS was characterized using a condensation particle counter as a reference and is nearly 100% for particles with diameter greater than 8 nm. In general, measured and simulated WFIMS mobility resolutions are in good agreement. But, some deviations are observed at low particle mobilities, likely due to the non-idealities of the WFIMS electric field.

54 ENVIRONMENTAL SCIENCES↗

Herschel Observations of Debris Disks from WISE

The \Vide Field Infrared Survey Explorer (WISE) has just completed a sensitive all-sky survey in photometric bands at 3.4, 4.6,12 and 22 microns. We report on a study of main sequence Hipparcos and Tycho catalog stars within 120 pc with WISE 22 micron emission in excess of photospheric levels. This warm excess emission traces material in the circumstellar region likely to host terrestrial planets and is preferentially found in young systems with ages < 1 Gyr. Nearly a hundred of the WISE new warm debris disk candidates detected among FGK stars are being observed by Herschel/PACS to characterize circumstellar dust. Preliminary results indicate 70 micron detection rates in excess of 80% for these targets, suggesting that most of these systems have both warm and cool dust in analogy to our asteroid and Kuiper belts. In this contribution, we will discuss the WISE debris disk survey and latest results from Herschel observations of these sources.

Padgett, D. L.↗

Detection of far-infrared (C-13)O line emission

Observations of the Ori KL star-formation region, obtained in the 151.4315-micron line of (C-13)O using the MkII UCB cryogenic tandem Fabry-Perot spectrometer on the NASA Kuiper Airborne Observatory in January 1988, are reported. The data are presented in tables and graphs and characterized in detail. The emission detected is found to be consistent with 10-30 solar masses of dense gas at temperature 200 K or greater, or with two or more regions (optically thin emission from a zone at 700 K or more and optically thick emission from a region of high column density identified with the hot core).

Genzel, R.↗

Mars Organic Molecule Analyzer (MOMA) Laser Desorption/Ionization Source Design and Performance Characterization

The Mars Organic Molecule Analyzer (MOMA), a dual-source, ion trap-based instrument capable of both pyrolysis-gas chromatography mass spectrometry (pyr/GC-MS) and laser desorption/ionization mass spectrometry (LDI-MS), is the core astrobiology investigation on the ExoMars rover. The MOMA instrument will be the first spaceflight mass analyzer to exploit the LDI technique to detect refractory organic compounds and characterize host mineralogy; this mode of analysis will be conducted at Mars ambient conditions. In order to achieve high performance in the Martian environment while keeping the instrument compact and low power, a number of innovative designs and components have been implemented for MOMA. These include a miniaturized linear ion trap (LIT), a fast actuating aperture valve with ion inlet tube, and a Microelectromechanical System (MEMS) Pirani sensor. Advanced analytical capabilities like Stored Waveform Inverse Fourier Transform (SWIFT) for selected ion ejection and tandem mass spectrometry (MS/MS) are realized in LDI-MS mode, and enable the isolation and enhancement of specific mass ranges and structural analysis, respectively. We report here the technical details of these instrument components as well as system-level analytical capabilities, and we review the applications of this technology to Mars and other high-priority targets of planetary exploration.

Xiang Li↗