Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Design Study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

High field electron paramagnetic resonance spectroscopy under ultrahigh vacuum conditions—A multipurpose machine to study paramagnetic species on well defined single crystal surfaces

A new ultrahigh vacuum (UHV) electron paramagnetic resonance (EPR) spectrometer operating at 94 GHz to investigate paramagnetic centers on single crystal surfaces is described. It is particularly designed to study paramagnetic centers on well-defined model catalysts using epitaxial thin oxide films grown on metal single crystals. The EPR setup is based on a commercial Bruker E600 spectrometer, which is adapted to ultrahigh vacuum conditions using a home made Fabry Perot resonator. The key idea of the resonator is to use the planar metal single crystal required to grow the single crystalline oxide films as one of the mirrors of the resonator. EPR spectroscopy is solely sensitive to paramagnetic species, which are typically minority species in such a system. Hence, additional experimental characterization tools are required to allow for a comprehensive investigation of the surface. The apparatus includes a preparation chamber hosting equipment, which is required to prepare supported model catalysts. In addition, surface characterization tools such as low energy electron diffraction (LEED)/Auger spectroscopy, temperature programmed desorption (TPD), and infrared reflection absorption spectroscopy (IRAS) are available to characterize the surfaces. A second chamber used to perform EPR spectroscopy at 94 GHz has a room temperature scanning tunneling microscope attached to it, which allows for real space structural characterization. The heart of the UHV adaptation of the EPR experiment is the sealing of the Fabry-Perot resonator against atmosphere. To this end it is possible to use a thin sapphire window glued to the backside of the coupling orifice of the Fabry Perot resonator. With the help of a variety of stabilization measures reducing vibrations as well as thermal drift it is possible to accumulate data for a time span, which is for low temperature measurements only limited by the amount of liquid helium. Test measurements show that the system can detect paramagnetic species with a density of approximately 5 × 10{sup 11} spins/cm{sup 2}, which is comparable to the limit obtained for the presently available UHV-EPR spectrometer operating at 10 GHz (X-band). Investigation of electron trapped centers in MgO(001) films shows that the increased resolution offered by the experiments at W-band allows to identify new paramagnetic species, that cannot be differentiated with the currently available methodology.

36 MATERIALS SCIENCE↗

Design Considerations and Analysis of Multi-Level Erasure Coding in Large-Scale Data Centers

Multi-level erasure coding (MLEC) has seen large deployments in the field, but there is no in-depth study of design considerations for MLEC at scale. In this paper, we provide comprehensive design considerations and analysis of MLEC at scale. We introduce the design space of MLEC in multiple dimensions, including various code parameter selections, chunk placement schemes, and various repair methods. We quantify their performance and durability, and show which MLEC schemes and repair methods can provide the best tolerance against independent/correlated failures and reduce repair network traffic by orders of magnitude. To achieve this, we use various evaluation strategies including simulation, splitting, dynamic programming, and mathematical modeling. We also compare the performance and durability of MLEC with other EC schemes such as SLEC and LRC and show that MLEC can provide high durability with higher encoding throughput and less repair network traffic over both SLEC and LRC.

Wang, Meng↗

FEED Study for Climeworks Direct Air Capture at a California Geothermal Facility with Long-Term Storage (Final Scientific/Technical Report)

The overall objective of the project is to execute and complete a front-end engineering and design (FEED) study of an advanced Direct Air Capture (DAC) and Storage (DAC+S) system that is capable of removing and sequestering a minimum of 5,000 tonne/yr of CO 2 from the air based on cradle-to-gate life cycle assessment (LCA). The project will examine retrofitting and utilizing an existing domestic geothermal resource. The selected DAC system will be technology from Climeworks AG (Climeworks) that consists of an adsorption-desorption process to remove CO 2 from ambient air by using a selective filter. The geothermal host site is operated by Ormat Technologies Inc. (ORMAT). The DAC system will capture CO 2 using thermal energy from the host geothermal resource. This Final Scientific/Technical Report is a collection of the deliverables for the project. The project team was not able to successfully complete all the necessary tasks for this project. Shortly after the start of the project, two (2) project partners removed themselves from the study. The Awardee attempted to find a replacement for the direct air capture technology provider and geothermal energy provider. Due to this the awardee submitted a letter of cancellation for the project, letter is attached in the appendix. No funds were expended during the course of the project.

15 GEOTHERMAL ENERGY↗

Compact fission counter for DANCE

The Detector for Advanced Neutron Capture Experiments (DANCE) consists of 160 BF{sub 2} crystals with equal solid-angle coverage. DANCE is a 4{pi} {gamma}-ray calorimeter and designed to study the neutron-capture reactions on small quantities of radioactive and rare stable nuclei. These reactions are important for the radiochemistry applications and modeling the element production in stars. The recognition of capture event is made by the summed {gamma}-ray energy which is equivalent of the reaction Q-value and unique for a given capture reaction. For a selective group of actinides, where the neutron-induced fission reaction competes favorably with the neutron capture reaction, additional signature is needed to distinguish between fission and capture {gamma} rays for the DANCE measurement. This can be accomplished by introducing a detector system to tag fission fragments and thus establish a unique signature for the fission event. Once this system is implemented, one has the opportunity to study not only the capture but also fission reactions. A parallel-plate avalanche counter (PPAC) has many advantages for the detection of heavy charged particles such as fission fragments. These include fast timing, resistance to radiation damage, and tolerance of high counting rate. A PPAC also can be tuned to be insensitive to {alpha} particles, which is important for experiments with {alpha}-emitting actinides. Therefore, a PPAC is an ideal detector for experiments requiring a fast and clean trigger for fission. A PPAC with an ingenious design was fabricated in 2006 by integrating amplifiers into the target assembly. However, this counter was proved to be unsuitable for this application because of issues related to the stability of amplifiers and the ability to separate fission fragments from {alpha}'s. Therefore, a new design is needed. A LLNL proposal to develop a new PPAC for DANCE was funded by NA22 in FY09. The design goal is to minimize the mass for the proposed counter and still be able to maintain a stable operation under extreme radioactivity and the ability to separate fission fragments from {alpha}'s. In the following sections, the description is given for the design and performance of this new compact PPAC, for studying the neutron-induced reactions on actinides using DANCE at LANL.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experimental studies of low density and temperature ion and electron sheaths

Full characterization of nighttime ionospheric plasma requires access to both the ion and electron thermal core populations. Efforts to measure particle distributions with rocket and satellite detectors designed to study low energy particles are hindered because the magnitude of spacecraft charging is on the order of or greater than the energy of the bulk of ionospheric particles. This paper presents initial laboratory investigations exploring the formation of plasma sheaths with ionospheric electron energies, densities, and Debye lengths. The goal is to identify the difficulties and solutions to obtaining both thermal electron and ion velocity distributions on one payload. Sheaths around a long cylinder biased with respect to the vacuum vessel wall are studied to verify measurement procedures. An experimental setup in which two conducting spheres, with area ratios in excess of 100, are biased with respect to one another and not referenced to the wall simulates a payload-detector system. Data are compared with simple planar, cylindrical, and spherical sheath models. Ion-rich sheaths conformed with expectations. The criterion for the formation of electron-rich sheaths was found not only to depend on the ratio of ion collector area to electron collector area but also the ratio of the collector area to sheath area. Nonmonotonic electron sheaths obtained by embedding a positively biased electrode within the sheath of a more negative conductor are also explored. It was found that the superposition of two different potential geometries led to the formation of the nonmonotonic potential structures. These initial plasma ion and electron sheath investigations both clarify the behavior of a thermal electron detector previously flown in the ionosphere and explore a low energy parameter regime that is understudied in the laboratory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

VTS Dynamic Model and Experimental Validation for Vibration Suppression

High Q-factor superconducting radio-frequency (SRF) cavities are extremely sensitive to mechanical vibrations, which can cause an uncontrolled shift of the electromagnetic resonance frequency, with detrimental effects on the cavity performance. To avoid this phenomenon (i.e. microphonics) the dynamic behavior of the assembly must be studied, to design vibration suppression systems. In this paper, the numerical model of the Vertical Test Stand (VTS) insert adopted at the Fermi National Accelerator Laboratory for cold tests was studied, in the framework of the experimental characterization of Dark SRF cavities conducted by the SQMS (Superconducting Quantum Materials and Systems) center. Due to the complexity of the assembly, experimental activity is of utmost importance to validate the model. Thus, vibration testing was performed on the actual system, and a good correlation between numerical and experimental results was found. Additionally, two different setups were compared, with and without implementing a preliminary passive vibration suppression system, to assess its effectiveness in reducing the microphonics phenomenon. The obtained results allowed for the design of an improved isolation system, which will be the subject of future experimental testing.

43 PARTICLE ACCELERATORS↗

A recoil separator for nuclear astrophysics SECAR

In this paper, a recoil separator SECAR has been designed to study radiative capture reactions relevant for the astrophysical rp-process in inverse kinematics for the Facility for Rare Isotope Beams (FRIB). Finally, we describe the design, layout, and ion optics of the recoil separator and present the status of the project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Examination of the 1970 National Bureau of Standards Underground Corrosion Test Welded Stainless STeel Coupons from Site D

A 1970 study initiated by the National Bureau of Standards (NBS), now known as the National Institute of Standards and Technology (NIST), buried over 6000 corrosion coupons or specimens of stainless steel Types 201, 202, 301, 304, 316, 409, 410, 430, and 434. The coupons were configured as sheet metal plates, coated plates, cross-welded plates, U-bend samples, sandwiched materials, and welded tubes. All coupons were of various heat-treatments and cold worked conditions and were buried at six distinctive soil-type sites throughout the United States. The NBS scientists dug five sets of two trenches at each of the six sites. In each pair of trenches, they buried duplicate sets of stainless steel coupons. The NBS study was designed to retrieve coupons after one year, two years, four years, eight years, and x years in the soil. During the first eight years of the study, four of five planned removals were completed. After the fourth retrieval, the NBS study was abandoned, and the fifth and final set of specimens remained undisturbed for over 33 years. In 2003, an interdisciplinary research team of industrial, university, and national laboratory investigators were funded under the United States Department of Energy’s Environmental Management Science Program (EMSP; Project Number 86803) to extract part of the remaining set of coupons at one of the test sites, characterize the stainless steel underground corrosion rates, and examine the fate and transport of metal ions into the soil. Extraction of one trench at one of the test sites occurred in April 2004. This report details only the characterization of corrosion found on the 14 welded coupons–two cross welded plates, six U-bends, and six welded tubes–that were retrieved from Site D, located near Wildwood, NJ. The welded coupons included Type 301, 304, 316, and 409 stainless steels. After 33 years in the soil, corrosion on the coupons varied according to alloy. This report discusses the stress corrosion cracking and crevice corrosion cracking of the U-bend coupons; the minimal corrosion found on the cross-bead plates; and the general, pitting, and crevice corrosion found on the welded tubes. In general, the austenitic Type 301, 304 and 316 samples showed little if any corrosion after 33+-years in the soil, whereas the ferritic alloys-Type 409 and 434– showed a spectrum of corrosion.

36 MATERIALS SCIENCE↗

Clinical, Laboratorial, and Urodynamic Findings of Prostatic Artery Embolization for the Treatment of Urinary Retention Related to Benign Prostatic Hyperplasia. A Prospective Single-Center Pilot Study

PurposeThis study was designed to describe the clinical, laboratorial, and urodynamic findings of prostatic artery embolization (PAE) in patients with urinary retention due to benign prostatic hyperplasia (BPH).MethodsA prospective study of 11 patients with urinary retention due to BPH was conducted. Patients underwent physical examination, prostate specific antigen (PSA) measurement, transrectal ultrasound, and magnetic resonance imaging. International prostate symptom score (IPSS), quality of life (QoL), and urodynamic testing were used to assess the outcome before and after 1 year.ResultsClinical success was 91 % (10/11 patients) with a mean follow-up of 22.3 months (range, 12-41 months). At the first year follow-up, the mean IPSS score was 2.8 points (p = 0.04), mean QoL was 0.4 points (p = 0.001), mean PSA decreased from 10.1 to 4.3 ng/mL (p = 0.003), maximum urinary flow (Qmax) improved from 4.2 to 10.8 mL/sec (p = 0.009), and detrusor pressure (Pdet) decreased from 85.7 to 51.5 cm H{sub 2}O (p = 0.007). Before PAE, Bladder Outlet Obstruction Index (BOOI) showed values >40 in 100 % of patients. After PAE, 30 % of patients were >40 (obstructed), 40 % were between 20 and 40 (undetermined), and 30 % were <20 (unobstructed). Patients with a BOOI <20 had higher PSA values at 1-day after PAE.ConclusionsClinical and urodynamic parameters improved significantly after PAE in patients with acute urinary retention due to BPH. Total PSA at day 1 after PAE was higher in patients with unobstructed values in pressure flow studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Overdriven-detonation states produced by spherically diverging waves

A series of experiments are currently underway at the Detonation Science and Technology group, within Los Alamos National Laboratory, to study the overdriven-detonation states achievable in energetic materials as a result of detonation-wave interactions. A multi-component, energetic-material array was designed to study the amplification of velocity and pressure states produced by spherically diverging detonation waves in pentaerythritol tetranitrate (PETN) output charges. The unique geometry provides a low-jitter, highly controlled series of interactions between three independent-detonation inputs. Streak-camera imaging was performed on the output face of PETN pellets ranging in thickness from 2.5 – 10 mm to characterize the resulting breakout profile. Additionally, photonic Doppler velocimetry (PDV) measurements were collected at the output-pellet surface to determine simultaneity within the system. Detonation-wave velocities upwards of 16 mm/µs were measured, as compared to a steady-state detonation velocity of 7.9 mm/µs for the PETN pressing density investigated. Finally, additional experiments are being conducted to measure the pressure amplification generated at key areas of interaction.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A scalable stochastic programming approach for the design of flexible systems

We study the problem of designing systems in order to minimize cost while meeting a given flexibility target. Flexibility is attained by enforcing a joint chance constraint, which ensures that the system will exhibit feasible operation with a given target probability level. Unfortunately, joint chance constraints are complicated mathematical objects that often need to be reformulated using mixed-integer programming (MIP) techniques. In this work, we cast the design problem as a conflict resolution problem that seeks to minimize cost while maximizing flexibility. We propose a purely continuous relaxation of this problem that provides a significantly more scalable approach relative to MIP methods and show that the formulation delivers solutions that closely approximate the Pareto set of the original joint chance-constrained problem.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Long-term mequindox treatment induced endocrine and reproductive toxicity via oxidative stress in male Wistar rats

Mequindox (MEQ) is a synthetic antimicrobial chemical of quinoxaline 1, 4-dioxide group. This study was designed to investigate the hypothesis that MEQ exerts testicular toxicity by causing oxidative stress and steroidal gene expression profiles and determine mechanism of MEQ testicular toxicity. In this study, adult male Wistar rats were fed with MEQ for 180 days at five different doses as 0, 25, 55, 110 and 275 mg/kg, respectively. In comparison to control, superoxide dismutase (SOD), reduced glutathione (GSH) and 8-hydroxydeoxyguanosine (8-OHdG) levels were elevated at 110 and 275 mg/kg MEQ, whereas the malondialdehyde (MDA) level was slightly increase at only 275 mg/kg. Furthermore, in LC/MS-IT-TOF analysis, one metabolite 2-isoethanol 4-desoxymequindox (M11) was found in the testis. There was significant decrease in body weight, testicular weight and testosterone at 275 mg/kg, serum follicular stimulating hormone (FSH) at 110 and 275 mg/kg, while lutinizing hormone (LH) levels were elevated at 110 mg/kg. Moreover, histopathology of testis exhibited germ cell depletion, contraction of seminiferous tubules and disorganization of the tubular contents of testis. Compared with control, mRNA expression of StAR, P450scc and 17{beta}-HSD in testis was significantly decreased after exposure of 275 mg/kg MEQ while AR and 3{beta}-HSD mRNA expression were significantly elevated at the 110 mg/kg MEQ group. Taken together, our findings provide the first and direct evidence in vivo for the formation of free radicals during the MEQ metabolism through N {yields} O group reduction, which may have implications to understand the possible mechanism of male infertility related to quinoxaline derivatives.

60 APPLIED LIFE SCIENCES↗

System for time resolved spectral studies of pulsed atmospheric discharges in the visible to vacuum ultraviolet range

Vacuum ultraviolet (VUV) emission is believed to play a major role in the development of plasma streamers in pulsed atmospheric discharges, but detection of VUV light is difficult in pulsed experiments at atmospheric pressures. Since VUV light is absorbed in most standard optical materials as well, careful attention must be given to the selection of the lens and mirror optics used in these studies. Of highest interest is the VUV emission during the initial stage of pulsed atmospheric discharges, which has a typical duration in the nanosecond regime. An experiment was designed to study this fast initial stage of VUV emission coupled with fast optical imaging of streamer propagation, both with temporal resolution on the order of nanoseconds. A repetitive solid-state high voltage pulser was constructed which produces triggered flashover discharges with low jitter and consistent pulse amplitude. VUV emission is captured utilizing both photomultiplier and intensified charge-coupled device detectors during the fast stage of streamer propagation. These results are discussed in context with the streamer formation photographed in the visible wavelength regime with 3 ns exposure time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and Optimization of a Hybrid Design for Quantum Transduction

This study presents the mechanical design and analysis of a quantum electro-optical transducer engineered to operate at millikelvin temperatures within a dilution refrigerator. The transducer enables bidirectional microwave-optical frequency conversion through a hybrid architecture that integrates a superconducting radiofrequency (SRF) cavity with an electro-optic optical cavity. Among several design options investigated, the configuration offering the best thermal and mechanical performance was selected, yielding a robust solution with reduced sensitivity to fabrication tolerances, improved heat dissipation, as well as alignment precision. The design ensures uniform temperature distribution, enabling higher laser pump powers and, thus, increased conversion efficiency, while maintaining mechanical stresses safely below the material yield strength. Electromagnetic simulations further validate the design, demonstrating enhanced coupling between the optical and microwave modes, as well as a broader tuning range achieved with smaller tuner displacements.

quantum computing↗

High performance protonic ceramic fuel cell systems for distributed power generation

The technology landscape around distributed generation continues to evolve in response to increasing demand for high-efficiency, low-emission, low-cost power generation. While emerging distributed power technologies, such as solid oxide fuel cells (SOFCs), continue to advance, they still face challenges due to their high capital costs, and shorter lifetimes that typically arise from electrochemical stack performance degradation at high operating temperatures (>750 °C). Recent advancements in protonic ceramic fuel cells (PCFCs) offer the potential to mitigate drawbacks of their higher temperature SOFC counterparts by enabling lower operating temperatures (550 °C–600 °C) with acceptable power densities. Here the present work leverages the recent progress in protonic ceramic cell and stack technology development to generate viable system configurations and evaluate the energetic performance potential of PCFC-based systems for stationary power generation. Process system engineering of two water-neutral system concepts, which provide 25 kW of electric power and process hot water, are presented and evaluated through sensitivity studies. Stack design parameters are altered and used to gauge the effect on system performance characteristics, including fuel cell stack and balance-of-plant sizing requirements, and electric and cogeneration efficiencies. The study finds that the potentially high per-pass fuel utilization capability of PCFC stacks could enable unprecedented electric efficiencies approaching 70% without hybridization with other prime movers.

25 ENERGY STORAGE↗

Smart Self-Assembled Organic Nanoprobe for Protein-Specific Detection: Design, Synthesis, Application, and Mechanism Studies

Specific detection or imaging protein has high potential to contribute greatly to medical diagnosis, biological research, and therapeutic applications. The level of human serum albumin (HSA) in blood is related to a variety of diseases and thus serves as an important biomarker for fast clinical diagnosis. In this paper we report the use of aggregation-induced emission (AIE) based supramolecular assembly to design biomolecular responsive smart organic nanomaterials for detection protein HSA. The designed nanoprobes were aggregates of small molecules and silent in fluorescence, but in the presence of HSA they disassembled and produced a clear turn-on fluorescent signal. Of a small library of nanoprobes constructed for HSA detection, structure-optical signaling and screening studies revealed that nanoprobe 7 is the most efficient one. Mechanism studies showed that nanoprobe 7 was bonded with Site I of HSA through the multiple noncovalent interactions. The resultant restriction of intramolecular rotation of nanoprobe 7 in the hydrophobic cavity of HSA induced fluorescent emission, which was validated by competitive binding assays and molecular docking. More importantly, nanoprobe 7 was successfully applied to recognize and quantify HSA in human serum samples. This study demonstrates nanoprobe 7 is a promising tool for clinical real and fast detection of HSA and thus may find many applications, and the molecular assembly based on AIE also opens a new avenue for designing smart nanomaterials for the sensitive and selective detection for varied analytes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a Testbed for Pipeline Flushing - 19409

Pipelines which carry radioactive waste within the DOE complex should be properly flushed, particularly in the cases where stationary or moving beds of solid sediment occur, or lines are prone to hydrogen gas buildup. Present guidelines establish a minimum for the amount of water used for post-transfer flushing operations to achieve satisfactory cleaning of pipelines. However, further studies are needed to limit the amount of water used for flushing operations, thus minimizing the consequent downstream waste. These efforts are significantly helpful to DOE waste remediation sites by preserving tank storage, preventing additional waste processing, and minimizing dilution and changes in waste chemistry. An experimental pipe loop designed for study of non-Newtonian slurry flushing is currently being developed at the Florida International University (FIU). The testbed is designed to investigate parameters that effect the efficiency of flushing operations. The objective is to find flush velocity values/modes which lead to satisfactory cleaning of transport lines with a minimum amount of water usage. The developed methodologies will be streamlined according to the demands from both Hanford and Savannah River sites. A test matrix containing parameters such as pipeline length, flow rate, and simulant composition (solid concentration, rheology, particle size and density) has been developed. In the initial phase of testing, material composition and loop length will be fixed to a mixture of 17 wt% kaolin in water (to attain density, viscosity, and yield stress in the applicable range to operations at Savannah River and Hanford sites) and 165 feet, respectively. This matrix provides a parametric study on the flush velocity. Prescribed velocities in this test matrix comply with the maximum and minimum recommended flush velocity values by the flushing guidelines for Hanford waste (RPP-RPT-59600, Rev. 0, SRNL-STI-2015-00014, TFC-ENG-STD-26, REV C-1). Efforts will focus on creating repeatable sediment beds inside the pipeline in both fully-flooded and gravity-drained systems. Bed characterization (i.e., measurement of sediment height, solids concentration, and rheology) will be conducted to ensure consistency of initial conditions between tests. A combination of Pulse-Echo technique, Coriolis meter, and optical inspections will be used to accomplish initial bed characterization (ensuring consistency between tests), control/monitor density variations (initial bed creation, flush velocity control, and post-flush evaluations), and serve as reference (validation of PulseEcho and pipe surface cleanness evaluation), respectively. This paper will present the details of the development of the test loop and the test matrix. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of countercurrent membrane vapor extraction of a dilute aqueous biosolute

Removal of dilute bioproducts from fermenter broths is a major challenge both to avoid microbe inhibition and to recover solutes economically without water loss. We analyze a proposed new process, membrane vapor extraction (MVE), where semi-volatile dilute aqueous solutes vaporize at the upstream side of an omniphobic, microporous membrane and dissolve into a nonpolar solvent highly favorable to the solutes but not to water. A new membrane-process analysis is outlined and applied to the countercurrent recovery of 2 wt % aqueous butanol by a prototype solvent (dodecane) at 40°C. Thermodynamic phase equilibria, pioneered by the Prausnitz school, are crucial to MVE process design. Over 90% of the feed butanol is recovered with essentially no water loss giving a separation factor of over 1000. Energy requirements in MVE are low. In this study, our design calculations demonstrate that MVE is a viable separation process to remove and recover dilute aqueous biosolutes.

mass-transfer resistance↗