Outgassing and contamination properties of prospective Apollo Telescope Mount materials.

Some of the test techniques used to evaluate the outgassing and contamination characteristics of prospective Apollo telescope mount (ATM) materials are reviewed. These include a screening test providing information on weight losses of materials, weights of their condensed outgas products, and white-light scattered by the condensed products. They also include an ultraviolet-region screening test and a comprehensive continuous in situ weight-loss test. Examples are presented of data obtained from each of the tests on various prospective ATM materials.

Poehlmann, H. C.↗

Effects of contaminants in CO2 lasers.

A theoretical model which includes the effects of contaminants is developed for the high flow electric discharge CO2-N2-He laser. The model couples the excitation and relaxation processes, CO2 dissociation, and negative ion formation with the flow processes. An analysis of the effects of CO, O2, NO, and N2O impurities on the average small signal gain is presented. CO decreases the gain by collisional depopulation of the upper laser level, and O2, NO, and N2O reduce the gain by decreasing the electron density by forming stable negative ions. In particular, N2O exhibits a strong quenching effect because of its large dissociation cross section for the formation of O(-).

Smith, N. S.↗

Spin contamination in unrestricted Hartree-Fock calculations.

Several pi-electron doublets are treated by both the unrestricted Hartree-Fock method and the restricted approximation of Longuet-Higgins and Pople. For two of the molecules, which contain oxygen heteroatoms, serious spin contamination occurs in the UHF wavefunctions, and this negates the usefulness of the single annihilation procedure that is often used for spin-density calculations. The restricted approximation provides a convenient alternative, especially because configuration interaction is easily taken into account.

Schug, J. C.↗

Optical module for the integrated real-time contamination monitor

The concept of a real time contamination monitor is studied and the evolution of the optical module component from laboratory model through the engineering evaluation model is reported. Mechanisms employed and problems experienced are described. Current efforts are directed toward a major simplification of design in a unit intended for flight.

Wrench, E. H.↗

Removal of spacecraft-surface particulate contaminants by simulated micrometeoroid impacts

A series of hypervelocity impacts has been conducted in an exploding lithium-wire accelerator to examine with a far-field holographic system the removal of particulate contaminants from external spacecraft surfaces subjected to micrometeoroid bombardment. The impacting projectiles used to simulate the micrometeoroids were glass spheres nominally 37 microns in diameter, having velocities between 4 and 17 km/sec. The particulates were glass spheres nominally 25, 50, and 75 microns in diameter which were placed on aluminum targets. For these test, particulates detached had velocities that were log-normally distributed. The significance of the log-normal behavior of the ejected-particulate velocity distribution is that the geometric mean velocity and the geometric standard deviation are the only two parameters needed to model completely the process of particles removed or ejected from a spacecraft surface by a micrometeoroid impact.

Goad, J. H., Jr.↗

Processings of the Workshop on Electron Contamination in X-Ray Astronomy Experiments

The proceedings of a conference to investigate the effects of extraterrestrial radiation and particle contamination of X-ray astronomical data are presented. The subjects discussed include the following: (1) electrons at low altitudes which affect soft X-ray astronomy, (2) the geographical distribution of 100 keV electrons above the earth's atmosphere, (3) midlatitude electron precipitation, (4) particle background observed by X-ray detectors on board Copernicus satellite, and (5) a survey of trapped low energy electrons near the inner boundary of the inner radiation zone as determined by OSO-7.

Holt, S. S.↗

Midlatitude electron precipitation: A possible source of contamination of galactic X and gamma-ray measurements

The effect of trapped and precipitated particles in the magnetosphere on the measurement of galactic X-rays and gamma rays is discussed. To minimize contamination caused by electron precipitation, most galactic X-ray and gamma ray measurements are conducted at equatorial or relatively low to middle latitudes where the influence of auroral effects is expected to be small. Substorm-related VLF phase perturbations also affect the measurements. If such perturbation are indicative of electron precipitation at middle to low latitudes, then their relatively high frequency of occurrence, as many as 100 per year, is evidence that electron precipitation at these latitudes may pose a problem to some galactic X-ray and gamma ray measurements. Charts and maps are presented to show: (1) phase recordings from sixteen sub-ionospheric VLF propagation paths, (2) map of great circle propagation paths, (3) ionization rates in the nighttime ionosphere due to several sources, and (4) computer phase variation for the NLK-APL path versus electron flux for different e-folding energies.

Rosenberg, T. J.↗

Electron contamination in a mid-latitude soft X-ray astronomy experiment during an intense magnetic storm

A large area X-ray sky survey payload was launched from White Sands Missile Range (106 deg W 32 deg N) on 1 Nov. 1972 at 0530 hours U.T. The launch time coincided with intense geomagnetic activity (3 hour K sub p index = 8) following a solar flare. The data have been analyzed to determine possible contamination of X-ray data by large fluxes of low energy electrons that can precipitate down to low altitudes during magnetic storms. There is clear evidence in the data for low energy electrons of 10 - 50 keV contributing appreciably at about 200 km altitude in the 1 - 10 keV X-ray energy channels of the proportional counters used for the X-ray observations. The McIlwain parameters L and B for this altitude at White Sands are 1.25 and 0.46G, respectively.

Naranan, S.↗

Organic contamination monitoring and control in the Lunar Receiving Laboratory

An assessment of the nature and amount of organic matter present in returned lunar material has been one of the major scientific goals of the Apollo programs. The small amounts of organic matter expected to be indigenous to the lunar material can be easily detected by the analytical instrumentation used in organic geochemistry. The integrity of the lunar samples could, therefore, only be maintained by carefully controlling the collection, processing, and analyses of the lunar material. The procedures for contamination control are discussed along with the experimental approaches.

Simoneit, B. R.↗

Test program on the contamination of ultraviolet region mirrors by Apollo Telescope Mount materials

Results are presented of testing performed to measure the effects of material outgas products on the reflectances of ultraviolet-region mirrors. These tests were to provide data on changes of ultraviolet reflectances of first-surface mirrors which had been exposed to the outgas products of selected materials under specific time and thermal-vacuum conditions. The requirement for such data was based on the extreme sensitivity of the sophisticated optical instruments in the Skylab mission's Apollo Telescope Mount (ATM) to condensed outgas products from materials, and on the desire to insure that no serious hazard of contaminating these instruments existed.

Austin, J. D.↗

Techniques of biological contamination avoidance by atmospheric probes

The likelihood of biologically contaminating a planet by an atmospheric probe has a low probability of occurring if the probe is kept biologically clean during terrestrial operations and if the structure remains in tact until the planets life zone is completely penetrated. High standards of cleanliness, monitoring and estimating for remedial actions must be maintained in a probe program. It is not a foregone conclusion, however, that heat sterilization needs to be employed. The use of several techniques having a good potential for lower probe costs are available and appear adequate to render a probe sterile within acceptable bounds. The techniques considered to be satisfactory for minimizing microbial load include: (1) combined heat (at 95-105 C) and gamma radiation; (2) short term heating at 105 + or - 5 C to inactivate all vegetative microbes; (3) irradiation routinely by ultraviolet light; (4) wiping by a bactericidal agent with or without a penetrant; and (5) cleanliness alone.

Defrees, R. E.↗

Optical effect of the contamination of infrared windows by the outgassing of materials in outer space

The composition and evaporation rate of the outgassing of a space vehicle thermal control paint as a function of temperature were studied. A contamination chamber was designed, constructed, and tested. Samples of thermal control paint were tested to determine if heating to moderate temperatures causes them to release outgassing products which can be collected on a cooled cesium iodide window for identification by IR analysis. Results showed that outgassing of surfaces other than the sample was a problem. Spectral bands of the deposits collected were compared.

Silberman, E.↗

Monitoring spacecraft atmosphere contaminants by laser absorption spectroscopy

Data were obtained which will provide a test of the accuracy of the differential absorption method for trace contaminant detection in many-component gas mixtures. The necessary accurate absorption coefficient determinations were carried out for several gases; acetonitrile, 1,2-dichloroethane, Freon-113, furan, methyl ethyl ketone, and t-butyl alcohol. The absorption coefficients are displayed graphically. An opto-acoustic method was tested for measuring absorbance, similar to the system described by Dewey.

Steinfeld, J. I.↗

Particulate contamination spectrometer. Volume 1: Technical report

A laser particulate spectrometer (LPS) system was developed to measure the size and speed distributions of particulate (dusts, aerosols, ice particles, etc.) contaminants. Detection of the particulates was achieved by means of light scattering and extinction effects using a single laser beam to cover a size range of 0.8 to 275 microns diameter and a speed range of 0.2 to 20 meter/second. The LPS system was designed to operate in the high vacuum environment of a space simulation chamber with cold shroud temperatures ranging from 77 to 300 K.

Schmitt, R. J.↗

The Relocation of Particulate Contamination During Space Flight

A computer simulation program to model the redistribution of particulate contaminants on a spacecraft after launch is developed. The component models for particulate adhesion, meteoroid impact, and electrostatic forces are described and intermediate results are presented. The results of a sample calculation show that the recontamination process is important.

Barengoltz, J.↗

Investigations of electret as a contamination control device

Thermoelectrets of polymers with stable surface charge on either side have been found to attract ions and charged particles to their surfaces. To assess their applicability to the control of atmospheric contamination, polytetraethylene (teflon) electrets are exposed to vapors coming from volatile mixtures over periods up to 90 min. Use is made of mass spectrometry for the analysis of teflon electret characteristics. It is found that even small quantities of the liquids in the mixture gives its characteristic mass spectra and that the peak height represents a measure for the quantity of the material collected over the electret surface, with the collected quantity being proportional to the duration of exposure.

Pillai, P. K. C.↗

The contamination of lunar highland rocks by KREEP - Interpretation by mixing models

A mixing model method was used to determine the component abundance in the Apollo 16 and 17 soils. This method uses the chemical composition of the soils for up to 30 elements and a weighted least-squares mixing model technique. Elements included in the calculations are: Si, Ti, Al, Ca, Fe, Mg, P, Cr, Mn, Na, K, Rb, Ba, U, Th, La, Ce, Sm, Eu, Sr, Yb, Y, Sc, V, Zr, Nb, Co, Ni, Li, Au, and Ir. The method was used to examine the possibility that some of the highland rocks such as VHA and low-K Fra Mauro basalt are mixtures. The results of the mixing model calculations show that it is possible that these rocks are mixtures of KREEP, troctolite, 'anorthosites', and a meteoritic component. The Rb-Sr systematics are consistent with such a model for the genesis of the highland rocks. KREEP has high relative concentrations of Rb, U, and radiogenic Sr and Pb and its model age of about 4.4 AE dominates the model age of all the 'contaminated' highland rocks.

Schonfeld, E.↗

Detecting contamination on a metal surface

Thin layers of contaminant on metal surface are detected by measuring surface-potential difference between reference electrode and surface of interest. Procedure does not require mechanical contact with surface under examination.