Reduced temperature preparation of atomically clean Si surfaces to augment CMOS with atomic precision devices.
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Natural gas furnaces are the most common space heating equipment in the U.S. residential and commercial building markets. However, current residential natural gas condensing furnaces generate substantial acidic condensate as well as significant emissions of sulfur oxides (SOx), nitrogen oxides (NOx), carbon monoxide (CO), hydrocarbons (HC), and methane (CH 4 ) contributing to environmental degradation of air, water, and soil. This report describes a novel solution to reduce the environmental impact of natural gas condensing furnaces based on the technology of a monolithic acidic gas reduction (AGR) catalyst for SOx trapping, NOx redox to nitrogen, and oxidation of formic acid, CO, HC, and CH 4 . The AGR technology offers the following benefits: (1) a neutral furnace condensate with a pH of ~7, allowing its safe release into the sewer system thus eliminating a second drainage system; (2) trapping and removing nearly all SOx emissions; (3) NOx emissions nearly at nearly 1-2 ng/J, more than 95% lower than new emissions standards in California; (4) the use of a low-cost heat exchanger as a condensing heat exchanger (HX) since the condensate is not acidic, avoiding the need for expensive stainless steel alloys; and (5) unburnt fuel energy recovery to boost efficiency.The AGR component and AGR-enabled furnace performance were broadly tested to determine their effects on long-term reliability and durability, as well as SOx storage and regeneration activity. The AGR regeneration does not impair the performance in achieving neutral condensate and ultra-low NOx emissions, and the AGR catalyst subjected to regeneration activities continued to function well and achieved slightly better annual fuel utilization efficiency (AFUE). The 400-hour reliability and durability test of the retrofitted condensing furnace with the AGR component shows that the furnace unit still achieves a neutral furnace condensate with a pH of ~7 and enables 0~3 ng/J of NOx emissions. However, the 400-hour operation slightly degraded the AFUE because of soot particle accumulation caused by frequent incomplete combustion owing to inappropriate condensate drainage during testing. Thus, proper condensate drainage is critical for AGR-enabled furnaces. Furthermore, neutron computed tomography was employed to survey the aged AGR component and demonstrate high-resolution 2D and 3D representations for the nondestructive diagnosis of the AGR component. The tomography showed that the AGR component did not deform or suffer broken AGR channels. A new AGR catalyst with low precious metal loading was preliminarily explored to identify a pathway of optimizing AGR material loading and maximizing acidic gas reduction at low cost. The new AGR component can reduce precious metal loading by 38% and still achieve neutral condensate and ultralow NOx emissions. The furnace with the AGR component of low Pt/Rh loading enables a maximum AFUE of 97%, which is meaningfully higher than the original furnace. Long-duration testing for the furnace enabled with the low precious metal loading AGR component will be vital in future research. Although the current work demonstrates a proof of concept for the AGR-enabled furnace, the AGR assembly needs to be optimized and integrated into the design of new OEM furnace products. Furthermore, the AGR technology can be applied not only for residential gas furnaces, but also for commercial rooftop units, gas heat pumps, gas-fired water heaters, combustion boilers, and other systems.
We worked on the production of hydrogen and sulfuric acid electrochemically. We did this by building an electrolyzer and performing techno-economic analysis for which we published a paper (documented above). We also performed many leaching reactions with acid similar to the acid that we would have produced. We found that it was not commercially viable to cogenerate hydrogen and sulfuric acid because the technical problems would take too long to solve under the constraints of venture capital.
Abstract not provided.
The study and use of non-model microbes in both natural and engineered systems, to tackle a range of national and global challenges. Unique combination of expertise from synthetic biology tool development and high throughput screening to aquatic and terrestrial environmental simulation systems.
This presentation summarizes the findings of a published paper on the first commercialization of four diverse energy technologies: thin film photovoltaics, wind turbine blades, dual-stage refrigeration evaporators, and fuel cells for material handling equipment.
The National Governor’s Association Center for Best Practices energy staff is focused on developing and implementing innovative solutions to state energy policy challenges. Among NGA’s energy teams focus are topics such as energy affordability, resilience, and reliability, which align with priorities of DOE’s WIP office. Given NGA’s direct connections with governors’ offices and longstanding support to governors’ policy staff on energy efficiency, renewable energy, resilience, reliability, affordability, and related topics, we are well suited to work alongside the U.S. Department of Energy (DOE) to support governors’ offices and key energy staff, address longstanding challenges, and deliver best practice solutions.
Explore the source record for details and available documents.
Island and remote coastal communities face an uncertain energy future. These communities build, operate, and maintain energy infrastructure in extremely challenging environments and pay the highest prices for electricity and fuels. Moreover, climate change increasingly affects grid reliability, resiliency, and, ultimately, the cost of energy. Marine energy could address many of the challenges faced by island and remote coastal communities, but these communities often have limited resources and capacity to invest in complex energy and coastal resilience issues. The Deployment Readiness Framework (DRF) is being developed to support community-driven energy transitions in these coastal communities and to better understand the readiness of communities for marine energy demonstration and operation. Led by the National Renewable Energy Laboratory and Pacific Northwest National Laboratory, the DRF builds on the Energy Transitions Initiative Partnership Project (ETIPP) supported in part by the U.S. Department of Energy's Water Power Technologies Office. This report details the results from the stakeholder outreach and engagement effort linked to the previously reported literature review.
Explore the source record for details and available documents.
Abstract not provided.
Abstract not provided.
The State and Local Planning for Energy (SLOPE) Platform is a free and easy-to-access online platform that helps energy planners at state and local levels make data-driven decisions to achieve their communities' energy goals.
Abstract not provided.
Energy and Environmental Economics, Inc. (E3) developed an open-source machine learning model, RESERVE, for deriving ancillary services timeseries in deeply decarbonized electricity grids. E3 used a bespoke PLEXOS production simulation model of the California Independent System Operator’s (CAISO) balancing area to validate RESERVE’s ability to enable production cost, greenhouse gas emissions (GHG), and renewable energy curtailment savings. These savings were modeled by comparing PLEXOS cases with RESERVE’s outputs to PLEXOS cases with CAISO’s incumbent reserve product in the Western Energy Imbalance Market (EIM)’s 15-minute market. E3 also tested cases with solar operating flexibly to provide reserves. E3 found that, in a 2030 modeling year, using RESERVE and flexible solar enabled significant production cost, GHG and curtailment savings versus the incumbent CAISO method in cases with low penetrations of lithium-ion batteries. However, with the full 14 gigawatts (about 30% of peak CAISO demand) of 4-hour lithium-ion batteries that are expected to be installed by 2030, these savings approach zero due to batteries saturating ancillary services markets. E3 also found significant savings under a 2019 benchmarking year.