Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CHROMATOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Radiation Tolerance Studies of Commercial Strippable Coatings and Fixatives used for Decontamination - 18642

A number of commercially available products, designed for use as strippable coating and fixatives for decontamination purposes, were tested to determine their tolerability to high radiation fields and how they potentially degrade. Each product was cured and exposed to γ-radiation from a Co-60 source, up to a total dose of 500 kGy. Obvious physical colour changes and deformities were detected by visual inspection, and images captured by scanning electron microscope (SEM) showed major differences post-irradiation in some coatings. Other physical changes to the coatings were measured using Fourier-transform infrared spectroscopy (FT-IR), Raman spectroscopy, and energy-dispersive X-ray spectroscopy (EDS); both pre- and post-irradiation. FT-IR suggested that some chemical changes were taking place in the coatings, in particular the C-H bonds and the fingerprint region appeared to be drastically altered in some coatings. EDS data indicated an increase in surface oxygen content as a result of irradiation in the majority of the samples. Additionally, coating samples were subjected to analysis by gas chromatography mass spectrometry (GCMS) in order to determine the evolved gases. The GC-MS results show that short chain hydrocarbons are produced to some degree in all the coatings during irradiation. Finally, three of the best performing coatings were selected and were irradiated using an ion beam, mimicking Pu alpha particles (with energy of around 5.25 MeV). Using the Dalton Cumbrian Facility's 5 MV tandem accelerator, coating samples were irradiated by ∼5.25 MeV He{sup 2+} particles to total dose of approximately 500 kGy. Samples were analysed using SEM, FT-IR, Raman and EDS, as was done for the gamma irradiated samples, allowing a comparison to be made between α-particle and γ-ray damage. Results from the alpha and gamma irradiations showed many similarities for the comparable assessments. A number of spectral changes observed in the FT-IR analysis were consistent across both γ-ray and α-particle irradiated samples. While there were some differences, these may be attributed to the conditions under which the irradiations were carried out. The observed similarities may allow for the inference of alpha degradation by Co-60 gamma irradiation as a more easily accessible method for determining the extent of radiolytic damage. Furthermore, gamma irradiation allows for additional analysis that is currently otherwise not possible to achieve with ion-beam exposure. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Preliminary Study on Sorption Behavior of Iodine on Ca-Al-Si Hydrate - 19310

Sorption behavior of Ca-Al-Si hydrate with iodine sign ion and iodide ion was investigated using ion chromatography and Raman spectroscopy. In the experiment I-127 which is a stable isotope was used instead of I-129 which is a radionuclide. Ca-Al-Si hydrate was synthesized by mixing fumed silica (SiO{sub 2}) calcium oxide (CaO) and aluminum nitrate nonahydrate (Al(NO{sub 3}){sub 3}.9H{sub 2}O) with the solution containing iodine in a polypropylene tube. Two chemical forms of iodine, i.e., iodide ion and iodate ion, were considered in this study. In the samples of Ca-Al-Si hydrate, the Ca/Si molar ratios were adjusted in the range from 0.8 to 1.6, and the Al / Si ratios were in the range from 0.0 to 0.5. The samples liquid / solid (L/S) ratio was 20. In order to adjust the concentration to 0.5 mM for each samples, NaIO{sub 3} solution or NaI solution were added to the sample. NaClO solution was added as an oxidizing agent to maintain the form of iodate ion. The synthesis procedure for all the samples was carried out in a glove bag filled with nitrogen gas. The curing time was 1, 7, 30 days at room temperature (298 K) with shaking at 120 strokes / minute. In the results, although the iodide ion concentration in the liquid phase hardly changed, the liquid phase amount had been reduced to less than the liquid phase amount initially added. This means that iodide ions are incorporated in the solid phase together with the water of hydration. Besides, the concentration of iodate ion remarkably decreased for all samples under experimental conditions. In the Raman analysis, some differences in structure due to incorporation of Al were observed, but the structure of the Ca-Al-Si hydrate hardly changed due to other factors. Based on the sorption distribution coefficients obtained in this study, the Ca-Al-Si hydrate can be expected to have a barrier performance against iodine. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Oxidation of Organics in the Defense Waste Processing Facility Condensate

Defense Waste Processing Facility (DWPF): The state of South Carolina currently holds 35 million gallons of radioactive waste in 51 underground tanks. DWPF was built in an effort to convert the waste into a more stable form. It turns the sludge waste from the tanks into glass, which will keep the waste stable for 10,000 years. Currently, DWPF uses formic acid in its flowsheet and there is one major problem associated with its use: it decomposes into hydrogen, a flammable gas. Glycolic acid, however, has been found as a possible alternative that performs similarly to formic acid but does not directly form hydrogen. One of the main issues with the glycolic acid flowsheet is the potential for there to be glycolate and other organics in DWPF's Recycle Collection Tank (RCT). These organics could lead to hydrogen generation later in the downstream evaporators and must be destroyed in the RCT in order for glycolic acid to be a suitable replacement for formic acid. Oxidants can be added to the RCT to destroy the organics. Two oxidizers, permanganate and Fenton's reagent (iron catalyzed hydrogen peroxide), are possible candidates. Find optimum processing conditions for the oxidation of organic species in a typical RCT simulant. A reactor served as a small-scale version of the RCT. During each run, an RCT simulant with 8 added organics, including glycolate, was created in the reactor. Either permanganate or peroxide was slowly added for each run through a syringe pump. Each experiment lasts 6 hours and a total of 23 runs are scheduled. Variables of Interest: Oxidizer (Permanganate or Peroxide); Temperature (15 deg. C to 50 deg. C); Oxidant addition time (10 mins to 2 hours); Amount of oxidant (1 x to 1.5 x stoichiometric requirements); Solution pH (3 to 13); Glycolate concentration (125 to 250 mg/kg). Offgas Analyzers: Mass spectrometer and FTIR spectrometer. Samples: pulled at 7 different times throughout the run to determine the amount of organic and inorganic carbon and concentrations of various organics through ion chromatography (IC). Only 3 of the runs have been completed at this point, all with permanganate. Based on the first 3 runs, permanganate seems to oxide the majority of the organics and the run at pH 8 and 32.5 deg. C had the most effective oxidation. The rest of the runs will need to be performed to determine the best oxidant and optimum values of the other variables of interest. Once the experiment is completed, DWPF will select one of the oxidants. Testing will continue to determine its performance during foam-over and other non-ideal conditions. Finally, the oxidant will be tested with actual radioactive waste to confirm its effectiveness.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Synthesis of cerium precursors with alkoxide ligands for degradation to cerium oxide nanoparticles

Lanthanide oxide and sulfide nanoparticles present intriguing theoretical questions regarding their electronic structures, alongside numerous potential applications in material science and catalysis. Although these materials can be formed through hydrolysis, their synthesis via thermolysis is crucial for nanoscale materials and practical applications. This research aims to enhance our understanding of the decomposition mechanisms by focusing on cerium compounds, which are analogous to those studied previously. Currently, our knowledge of the decomposition mechanisms of cerium alkoxide precursors is limited. The objective of this project is to develop a mechanistic understanding of the formation of cerium oxide nanoparticles from cerium alkoxide precursors, employing a variety of techniques. These techniques include collision-induced dissociation in an ion-trap mass spectrometer, nuclear magnetic resonance (NMR) spectroscopy, thermogravimetric analysis coupled with differential scanning calorimetry (TGA-DSC), and gas chromatography-mass spectrometry (GC-MS) to investigate the decomposition mechanisms of the synthesized precursors.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗

Aerosol composition, chemistry, and source characterization during the 2008 VOCALS Experiment

Chemical composition of fine aerosol particles over the northern Chilean coastal waters was determined onboard the U.S. DOE G-1 aircraft during the VOCALS (VAMOS Ocean-Cloud-Atmosphere-Land Study) field campaign between October 16 and November 15, 2008. SO42-, NO3-, NH4+, and total organics (Org) were determined using an Aerodyne Aerosol Mass Spectrometer, and SO42-, NO3-, NH4+, Na+, Cl-, CH3SO3-, Mg2+, Ca2+, and K+ were determined using a particle-into-liquid sampler-ion chromatography technique. The results show the marine boundary layer (MBL) aerosol mass was dominated by non- sea-salt SO42- followed by Na+, Cl-, Org, NO3-, and NH4+, in decreasing importance; CH3SO3-, Ca2+, and K+ rarely exceeded their respective limits of detection. The SO42- aerosols were strongly acidic as the equivalent NH4+ to SO42- ratio was only {approx}0.25 on average. NaCl particles, presumably of sea-salt origin, showed chloride deficits but retained Cl- typically more than half the equivalency of Na+, and are externally mixed with the acidic sulfate aerosols. Nitrate was observed only on sea-salt particles, consistent with adsorption of HNO3 on sea-salt aerosols, responsible for the Cl- deficit. Dust particles appeared to play a minor role, judging from the small volume differences between that derived from the observed mass concentrations and that calculated based on particle size distributions. Because SO42- concentrations were substantial ({approx}0.5 - {approx}3 {micro}g/m3) with a strong gradient (highest near the shore), and the ocean-emitted dimethylsulfide and its unique oxidation product, CH3SO3-, were very low (i.e., {le} 40 parts per trillion and <0.05 {micro}g/m3, respectively), the observed SO42- aerosols are believed to be primarily of terrestrial origin. Back trajectory calculations indicate sulfur emissions from smelters and power plants along coastal regions of Peru and Chile are the main sources of these SO4- aerosols. However, compared to observations, model calculations appeared to underestimate sulfate concentrations based on an existing emission inventory. The agreement between observations and model predictions of CO as well as total sulfur is reexamined in this work with a new emission inventory made available recently.

54 ENVIRONMENTAL SCIENCES↗

Circular Dichrosim Studies on the Deinococcus Radiodurans Nudix Hydrolase DR_0079: an Atypical Thermal Melt

We have recently determined the solution structure of the hypothetical Deinococcus radiodurans Nudix protein DR0079 [Proteins 56:28-39]. The protein is a monomer and contains the fundamental fold common to the Nudix family, a large mixed b-sheet sandwiched between a-helices. The protein¹s physical properties were further characterized by circular dichroism (CD) spectroscopy. A CD thermal melt indicates an inflection point at ~52ºC. However, unlike typical CD thermal melts, the ellipticity at 220 nm decreases upon passing through the inflection point suggesting that the amount of secondary structure in the protein has increased after heating. NMR spectroscopy and size exclusion chromatography indicates that heating effects the irreversible formation of a large molecular weight complex. After cooling, the ellipiticity at 220 nm increases further, and overall, the CD spectrum at 25ºC shows that heat-treated DR0079 has more ³structure² than non-heat treated DR0079.

59 BASIC BIOLOGICAL SCIENCES↗

EFFECT OF TEMPERATURE AND HUMIDITY ON FORMALDEHYDE EMISSIONS IN TEMPORARY HOUSING UNITS

The effect of temperature and humidity on formaldehyde emissions from samples collected from temporary housing units (THUs) was studied. The THUs were supplied by the U.S Federal Emergency Management Administration (FEMA) to families that lost their homes in Louisiana and Mississippi during the Hurricane Katrina and Rita disasters. Based on a previous study 1, 2, four of the composite wood surface materials that dominated contributions to indoor formaldehyde were selected to analyze the effects of temperature and humidity on the emission factors. Humidity equilibration experiments were carried out on two of the samples to determine how long the samples take to equilibrate with the surrounding environmental conditions. Small chamber experiments were then conducted to measure emission factors for the four surface materials at various temperature and humidity conditions. The samples were analyzed for formaldehyde via high performance liquid chromatography. The experiments showed that increases in temperature or humidity contributed to an increase in emission factors. A linear regression model was built using natural log of percentage relative humidity (RH) and inverse of temperature (in K) as predictor variables, and natural log of emission factors as the target variable. The coefficients of both inverse temperature and log relative humidity with log emission factor were found to be statistically significant for all the samples at the 95percent confidence level. This study should assist to retrospectively estimate indoor formaldehyde exposures of occupants of temporary housing units (THUs).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nickel Superoxide Dismutase: Structural and Functional Roles of Cys2 and Cys6

Nickel superoxide dismutase (NiSOD) is unique among the family of superoxide dismutase enzymes in that it coordinates Cys residues (Cys2 and Cys6) to the redox-active metal center and exhibits a hexameric quaternary structure. To assess the role of the Cys residues with respect to the activity of NiSOD, mutations of Cys2 and Cys6 to Ser (C2S-NiSOD, C6S-NiSOD, and C2S/C6S-NiSOD) were carried out. The resulting mutants do not catalyze the disproportionation of superoxide, but retain the hexameric structure found for wild-type NiSOD and bind Ni(II) ions in a 1:1 stoichiometry. X-ray absorption spectroscopic studies of the Cys mutants revealed that the nickel active-site structure for each mutant resembles that of C2S/C6S-NiSOD and demonstrate that mutation of either Cys2 or Cys6 inhibits coordination of the remaining Cys residue. Mutation of one or both Cys residue(s) in NiSOD induces the conversion of the low-spin Ni(II) site in the native enzyme to a high-spin Ni(II) center in the mutants. This result indicates that coordination of both Cys residues is required to generate the native low-spin configurations and maintain catalytic activity. Analysis of the quaternary structure of the Cys mutants by differential scanning calorimetry, mass spectrometry, and size-exclusion chromatography revealed that the Cys ligands, particularly Cys2, are also important for stabilizing the hexameric quaternary structure of the native enzyme.

59 BASIC BIOLOGICAL SCIENCES↗

Ion Mobility Mass Spectrometry Direct Isotope Abundance Analysis

The nuclear forensics community is currently engaged in the analysis of illicit nuclear or radioactive material for the purposes of non-proliferations and attribution. One technique commonly employed for gathering nuclear forensics information is isotope analysis. At present, the state-of-the-art methodology for obtaining isotopic distributions is thermal ionization mass spectrometry (TIMS). Although TIMS is highly accurate at determining isotope distributions, the technique requires an elementally pure sample to perform the measurement. The required radiochemical separations give rise to sample preparation times that can be in excess of one to two weeks. Clearly, the nuclear forensics community is in need of instrumentation and methods that can expedite their decision making process in the event of a radiological release or nuclear detonation. Accordingly, we are developing instrumentation that couples a high resolution IM drift cell to the front end of a MS. The IM cell provides a means of separating ions based upon their collision cross-section and mass-to-charge ratio (m/z). Two analytes with the same m/z, but with different collision cross-sections (shapes) would exit the cell at different times, essentially enabling the cell to function in a similar manner to a gas chromatography (GC) column. Thus, molecular and atomic isobaric interferences can be effectively removed from the ion beam. The mobility selected chemical species could then be introduced to a MS for high-resolution mass analysis to generate isotopic distributions of the target analytes. The outcome would be an IM/MS system capable of accurately measuring isotopic distributions while concurrently eliminating isobaric interferences and laboratory radiochemical sample preparation. The overall objective of this project is developing instrumentation and methods to produce near real-time isotope distributions with a modular mass spectrometric system that performs the required gas-phase chemistry and separations. The system couples a high-resolution ion mobility (IM) drift cell to the front end of a mass spectrometer (MS) allowing for chemical separation prior to isotope distribution analyses. This will yield isotope ratio measurement capabilities with minimal sample preparation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mass Spectrometry-based Assay for High Throughput and High Sensitivity Biomarker Verification

Searching for disease specific biomarkers has become a major undertaking in the biomedical research field as the effective diagnosis, prognosis and treatment of many complex human diseases are largely determined by the availability and the quality of the biomarkers. A successful biomarker as an indicator to a specific biological or pathological process is usually selected from a large group of candidates by a strict verification and validation process. To be clinically useful, the validated biomarkers must be detectable and quantifiable by the selected testing techniques in their related tissues or body fluids. Due to its easy accessibility, protein biomarkers would ideally be identified in blood plasma or serum. However, most disease related protein biomarkers in blood exist at very low concentrations (<1ng/mL) and are “masked” by many none significant species at orders of magnitude higher concentrations. The extreme requirements of measurement sensitivity, dynamic range and specificity make the method development extremely challenging. The current clinical protein biomarker measurement primarily relies on antibody based immunoassays, such as ELISA. Although the technique is sensitive and highly specific, the development of high quality protein antibody is both expensive and time consuming. The limited capability of assay multiplexing also makes the measurement an extremely low throughput one rendering it impractical when hundreds to thousands potential biomarkers need to be quantitatively measured across multiple samples. Mass spectrometry (MS)-based assays have recently shown to be a viable alternative for high throughput and quantitative candidate protein biomarker verification. Among them, the triple quadrupole MS based assay is the most promising one. When it is coupled with liquid chromatography (LC) separation and electrospray ionization (ESI) source, a triple quadrupole mass spectrometer operating in a special selected reaction monitoring (SRM) mode, also known as multiple reaction monitoring (MRM), is capable of quantitatively measuring hundreds of candidate protein biomarkers from a relevant clinical sample in a single analysis. The specificity, reproducibility and sensitivity could be as good as ELISA. Furthermore, SRM MS can also quantify protein isoforms and post-translational modifications, for which traditional antibody-based immunoassays often don’t exist.

Environmental Molecular Sciences Laboratory↗

An Extremely Stable, Highly Soluble Monosubstituted Anthraquinone for Aqueous Redox Flow Batteries

An extremely stable, energy-dense (53.6 Ah L –1 , 2 M transferrable electrons), low crossover (permeability of <1 × 10 –13 cm 2 s –1 using Nafion 212 (Nafion is a trademark polymer from DuPont)), and potentially inexpensive anthraquinone with 2-2-propionate ether anthraquinone structure (abbreviated 2-2PEAQ) is synthesized and extensively evaluated under practically relevant conditions for use in the negolyte of an aqueous redox flow battery. 2-2PEAQ shows a high stability with a fade rate of 0.03–0.05% per day at different applied current densities, cut-off voltage windows, and concentrations (0.1 and 1.0 M ) in both a full cell paired with a ferro/ferricyanide posolyte as well as a symmetric cell. 2-2PEAQ is further shown to have extreme long-term stability, losing only ≈0.01% per day when an electrochemical rejuvenation strategy is employed. From post-mortem analysis (nuclear magnetic resonance (NMR), liquid chromatography–mass spectrometry (LC-MS), and cyclic voltammetry (CV)) two degradation mechanisms are deduced: side chain loss and anthrone formation. 2-2PEAQ with the ether linkages attached on carbons non-adjacent to the central ring is found to have three times lower fade rate compared to its isomer with ether linkages on the carbon adjacent to the central quinone ring. Here, the present study introduces a viable negolyte candidate for grid-scale aqueous organic redox flow batteries.

25 ENERGY STORAGE↗

Quantitative and Qualitative Determination of Polysulfide Species in the Electrolyte of a Lithium-Sulfur Battery using HPLC ESI/MS with One-Step Derivatization

The polysulfide species dissolved in aprotic solvents can be separated and analyzed by reverse phase (RP) high performance liquid chromatography (HPLC) in tandem with electrospray-mass spectroscopy. The relative distribution of polysulfide species in the electrolyte recovered from Li-S batteries is quantitatively and reliably determined for the first time.

25 ENERGY STORAGE↗

Revisiting Discharge Mechanism of CF x as a High Energy Density Cathode Material for Lithium Primary Battery

Lithium/fluorinated graphite (Li/CFx) primary batteries show great promise for applications in a wide range of energy storage systems due to their high energy density (>2100 Wh kg –1 ) and low self-discharge rate (<0.5% per year at 25 °C). While the electrochemical performance of the CF x cathode is indeed promising, the discharge reaction mechanism is not thoroughly understood to date. In this article, a multiscale investigation of the CF x discharge mechanism is performed using a novel cathode structure to minimize the carbon and fluorine additives for precise cathode characterizations. Titration gas chromatography, X-ray diffraction, Raman spectroscopy, X-ray photoelectron spectroscopy, scanning electron microscopy, cross-sectional focused ion beam, high-resolution transmission electron microscopy, and scanning transmission electron microscopy with electron energy loss spectroscopy are utilized to investigate this system. Results show no metallic lithium deposition or intercalation during the discharge reaction. Crystalline lithium fluoride particles uniformly distributed with <10 nm sizes into the CF x layers, and carbon with lower sp2 content similar to the hard-carbon structure are the products during discharge. This article deepens the understanding of CF x as a high energy density cathode material and highlights the need for future investigations on primary battery materials to advance performance.

25 ENERGY STORAGE↗

Suppressing Chemical Corrosions of Lithium Metal Anodes

In this study, the lithium metal anode is essential for next-generation high-energy-density rechargeable Li-metal batteries. Although extensive studies have been performed to prolong the cycle life of Li-metal batteries, the calendar life, which associates with the chemical corrosion of Li metal in liquid electrolytes, has not been quantitatively understood. Here, by combing the titration gas chromatography method and cryogenic focused ion beam, a quantitative relationship between the chemical corrosion rate and electrochemically deposited Li morphology in various liquid electrolyte systems is established. It has been identified that the corrosion rate is dominated by the porosity of the deposited Li. The larger the porosity of deposited Li has, the faster the corrosion rate will be. Strategies to mitigate the chemical corrosion on Li thus to extend the calendar life of Li-metal batteries are further proposed. By strictly controlling the stacking pressure during Li plating, Li deposits with ultra-low porosity can be achieved, suppressing the corrosion rate to 0.08 ± 0.16%/day compared with 1.71 ± 0.19%/day of the high-porosity Li.

25 ENERGY STORAGE↗

Optimization of flow in additively manufactured porous columns with graded permeability

Chemical engineering systems often involve a functional porous medium, such as in catalyzed reactive flows, fluid purifiers, and chromatographic separations. Ideally, the flow rates throughout the porous medium are uniform, and all portions of the medium contribute efficiently to its function. The permeability is a property of a porous medium that depends on pore geometry and relates flow rate to pressure drop. Additive manufacturing techniques raise the possibilities that permeability can be arbitrarily specified in three dimensions, and that a broader range of permeabilities can be achieved than by traditional manufacturing methods. Using numerical optimization methods, we show that designs with spatially varying permeability can achieve greater flow uniformity than designs with uniform permeability. We consider geometries involving hemispherical regions that distribute flow, as in many glass chromatography columns. By several measures, significant improvements in flow uniformity can be obtained by modifying permeability only near the inlet and outlet.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of pyrolysis operating conditions on the catalytic co‐pyrolysis of low‐density polyethylene and polyethylene terephthalate with zeolite catalysts

Abstract In this study, the catalytic (co‐)pyrolysis of low‐density polyethylene (LDPE) and polyethylene terephthalate (PET) with HZSM‐5 and HY zeolite catalysts was conducted in a micro‐pyrolysis reactor coupled to a two‐dimensional gas chromatography system. Pyrolysis operating conditions, such as the pyrolysis temperature, the catalyst to feedstock (CF) ratio, and the LDPE:PET ratio, were varied. It was found that for the co‐pyrolysis of LDPE and PET, HZSM‐5 led to higher yields of C2‐C4 olefins and monoaromatic products. Lower CF ratios increased the yield of C2‐C4 olefins for LDPE pyrolysis, but decreased benzene yield for PET pyrolysis, concomitant with an increased yield in benzoic acid. A lower temperature of 400°C which was sufficient for the pyrolysis of LDPE, led to incomplete conversion of PET. Surface response diagrams were used to visualize the impact of the various pyrolysis operating conditions on the yield of C2‐C4 olefins and BTEX, which serve as target products for the circular economy.

Okonsky, Sean Timothy↗

A High‐Throughput Mass Spectrometric Enzyme Activity Assay Enabling the Discovery of Cytochrome P450 Biocatalysts

Abstract Assaying for enzymatic activity is a persistent bottleneck in biocatalyst and drug development. Existing high‐throughput assays for enzyme activity tend to be applicable only to a narrow range of biochemical transformations, whereas universal enzyme characterization methods usually require chromatography to determine substrate turnover, greatly diminishing throughput. We present an enzyme activity assay that allows the high‐throughput mass‐spectrometric detection of enzyme activity in complex matrices without the need for a chromatographic step. This technology, which we call probing enzymes with click‐assisted NIMS (PECAN), can detect the activity of medically and biocatalytically significant cytochrome P450s in cell lysate, microsomes, and bacteria. Using this approach, a cytochrome P450 BM3 mutant library was successfully screened for the ability to catalyze the oxidation of the sesquiterpene valencene.

de Rond, Tristan↗

Cooperative Self‐Assembly of Pyridine‐2,6‐Diimine‐Linked Macrocycles into Mechanically Robust Nanotubes

Abstract Nanotubes assembled from macrocyclic precursors offer a unique combination of low dimensionality, structural rigidity, and distinct interior and exterior microenvironments. Usually the weak stacking energies of macrocycles limit the length and mechanical strength of the resultant nanotubes. Imine‐linked macrocycles were recently found to assemble into high‐aspect ratio (>10 3 ), lyotropic nanotubes in the presence of excess acid. Yet these harsh conditions are incompatible with many functional groups and processing methods, and lower acid loadings instead catalyze macrocycle degradation. Here we report pyridine‐2,6‐diimine‐linked macrocycles that assemble into high‐aspect ratio nanotubes in the presence of less than 1 equiv of CF 3 CO 2 H per macrocycle. Analysis by gel permeation chromatography and fluorescence spectroscopy revealed a cooperative self‐assembly mechanism. The low acid concentrations needed to induce assembly enabled nanofibers to be obtained by touch‐spinning, which exhibit higher Young's moduli (1.33 GPa) than many synthetic polymers and biological filaments. These findings represent a breakthrough in the design of inverse chromonic liquid crystals, as assembly under such mild conditions will enable the design of structurally diverse and mechanically robust nanotubes from synthetically accessible macrocycles.

Strauss, Michael J.↗