Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Beam Optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Self-Focused Pulse Propagation Is Mediated by Spatiotemporal Optical Vortices

We show that the dynamics of high-intensity laser pulses undergoing self-focused propagation in a nonlinear medium can be understood in terms of the topological constraints imposed by the formation and evolution of spatiotemporal optical vortices (STOVs). STOVs are born from point phase defects on the sides of the pulse nucleated by spatiotemporal phase shear. These defects grow into closed loops of spatiotemporal vorticity that initially exclude the pulse propagation axis, but then reconnect to form a pair of toroidal vortex rings that wrap around it. STOVs constrain the intrapulse flow of electromagnetic energy, controlling the focusing-defocusing cycles and pulse splitting inherent to nonlinear pulse propagation. Here, we illustrate this in two widely studied but very different regimes, relativistic self-focusing in plasma and nonrelativistic self-focusing in gas, demonstrating that STOVs mediate nonlinear propagation irrespective of the detailed physics.

42 ENGINEERING↗

Propagation of high-energy laser beams through the earth's atmosphere II; Proceedings of the Meeting, Los Angeles, CA, Jan. 21-23, 1991

Consideration is given to turbulence at the inner scale, modeling turbulent transport in laser beam propagation, variable wind direction effects on thermal blooming correction, realistic wind effects on turbulence and thermal blooming compensation, wide bandwidth spectral measurements of atmospheric tilt turbulence, remote alignment of adaptive optical systems with far-field optimization, focusing infrared laser beams on targets in space without using adaptive optics, and a simplex optimization method for adaptive optics system alignment. Consideration is also given to ground-to-space multiline propagation at 1.3 micron, a path integral approach to thermal blooming, functional reconstruction predictions of uplink whole beam Strehl ratios in the presence of thermal blooming, and stability analysis of semidiscrete schemes for thermal blooming computation.

Ulrich, Peter B.↗

The use of an optical data acquisition system for bladed disk vibration analysis

A new concept in instrumentation was developed by engineers at NASA Lewis Research Center to collect vibration data from multi-bladed rotors. This new concept, known as the optical data acquisition system, uses optical transducers to measure bladed tip delections by reflection light beams off the tips of the blades as they pass in front of the optical transducer. By using an array of transducers around the perimeter of the rotor, detailed vibration signals can be obtained. In this study, resonant frequencies and mode shapes were determined for a 56 bladed rotor using the optical system. Frequency data from the optical system was also compared to data obtained from strain gauge measurements and finite element analysis and was found to be in good agreement.

Lawrence, C.↗

Incident beam polarization for laser Doppler velocimetry employing a sapphire cylindrical window

For laser Doppler velocimetry studies employing sapphire windows as optical access ports, the birefringency of sapphire produces an extra beam intersection volume which serves to effectively smear the acquired velocity flow field data. It is shown that for a cylindrical window geometry, the extra beam intersection volume may be eliminated with minimal decrease in the fringe visibility of the remaining intersection volume by suitably orienting the polarizations of the initial laser beams. For horizontally incident beams, these polarizations were measured at three intersection locations within the cylinder. It was found that the measured polarization angles agreed with the theoretical predictions.

Lock, J. A.↗

Incident beam polarization for laser Doppler velocimetry employing a sapphire cylindrical window

For laser Doppler velocimetry studies employing sapphire windows as optical access ports, the birefringency of sapphire produces an extra beam intersection volume which serves to effectively smear the acquired velocity flow field data. It is shown that for a cylindrical window geometry, the extra beam intersection volume may be eliminated with minimal decrease in the fringe visibility of the remaining intersection volume by suitably orienting the polarizations of the initial laser beams. For horizontally incident beams, these polarizations were measured at three intersection locations within the cylinder. It was found that the measured polarization angles agreed with the theoretical predictions.

Lock, J. A.↗

The design and development of a solar tracking unit

The solar tracking unit was developed to support the Laser Heterodyne Spectrometer (LHS) airborne instrument, but has application to a general class of airborne solar occultation research instruments. The unit consists of a mirror mounted on two gimbals, one of which is hollow. The mirror reflects a 7.6 cm (3.0 in.) diameter beam of sunlight through the hollow gimbal into the research instrument optical axis. A portion of the reflected sunlight is directed into a tracking telescope which uses a four quadrant silicon detector to produce the servo error signals. The colinearity of the tracker output beam and the research instrument optical axis is maintained to better than + or - 1 arc-minute. The unit is microcomputer controlled and is capable of stand alone operation, including automatic Sun acquisition or operation under the control of the research instrument.

Jones, I. W.↗

An ultra-compact x-ray free-electron laser

In the field of beam physics, two frontier topics have taken center stage due to their potential to enable new approaches to discovery in a wide swath of science. These areas are: advanced, high gradient acceleration techniques, and x-ray free electron lasers (XFELs). Further, there is intense interest in the marriage of these two fields, with the goal of producing a very compact XFEL. In this context, recent advances in high gradient radio-frequency cryogenic copper structure research have opened the door to the use of surface electric fields between 250 and 500 MV m -1 . Such an approach is foreseen to enable a new generation of photoinjectors with six-dimensional beam brightness beyond the current state-of-the-art by well over an order of magnitude. This advance is an essential ingredient enabling an ultra-compact XFEL (UC-XFEL). In addition, one may accelerate these bright beams to GeV scale in less than 10 m. Such an injector, when combined with inverse free electron laser-based bunching techniques can produce multi-kA beams with unprecedented beam quality, quantified by 50 nm-rad normalized emittances. The emittance, we note, is the effective area in transverse phase space (x, p x /m e c) or (y, p y /m e c) occupied by the beam distribution, and it is relevant to achievable beam sizes as well as setting a limit on FEL wavelength. These beams, when injected into innovative, short-period (1–10 mm) undulators uniquely enable UC-XFELs having footprints consistent with university-scale laboratories. We describe the architecture and predicted performance of this novel light source, which promises photon production per pulse of a few percent of existing XFEL sources. We review implementation issues including collective beam effects, compact x-ray optics systems, and other relevant technical challenges. To illustrate the potential of such a light source to fundamentally change the current paradigm of XFELs with their limited access, we examine possible applications in biology, chemistry, materials, atomic physics, industry, and medicine—including the imaging of virus particles—which may profit from this new model of performing XFEL science.

47 OTHER INSTRUMENTATION↗

A coherent light scanner for optical processing of large format transparencies

A laser scanner is discussed in which the scanning beam is random-access addressable and perpendicular to the image input plane and the irradiance of the scanned beam is controlled so that a constant average irradiance is maintained after passage through the image plane. The scanner's optical system and design are described, and its performance is evaluated. It is noted that with this scanner, data in the form of large-format transparencies can be processed without the expense, space, maintenance, and precautions attendant to the operation of a high-power laser with large-aperture collimating optics. It is shown that the scanned format as well as the diameter of the scanning beam may be increased by simple design modifications and that higher scan rates can be achieved at the expense of resolution by employing acousto-optic deflectors with different relay optics.

Callen, W. R.↗

A compact cold-atom interferometer with a high data-rate grating magneto-optical trap and a photonic-integrated-circuit-compatible laser system

Abstract The extreme miniaturization of a cold-atom interferometer accelerometer requires the development of novel technologies and architectures for the interferometer subsystems. Here, we describe several component technologies and a laser system architecture to enable a path to such miniaturization. We developed a custom, compact titanium vacuum package containing a microfabricated grating chip for a tetrahedral grating magneto-optical trap (GMOT) using a single cooling beam. In addition, we designed a multi-channel photonic-integrated-circuit-compatible laser system implemented with a single seed laser and single sideband modulators in a time-multiplexed manner, reducing the number of optical channels connected to the sensor head. In a compact sensor head containing the vacuum package, sub-Doppler cooling in the GMOT produces 15 μK temperatures, and the GMOT can operate at a 20 Hz data rate. We validated the atomic coherence with Ramsey interferometry using microwave spectroscopy, then demonstrated a light-pulse atom interferometer in a gravimeter configuration for a 10 Hz measurement data rate and T = 0–4.5 ms interrogation time, resulting in Δ g / g = 2.0 × 10 −6 . This work represents a significant step towards deployable cold-atom inertial sensors under large amplitude motional dynamics.

74 ATOMIC AND MOLECULAR PHYSICS↗

Impact of Photon Recycling, Grain Boundaries, and Nonlinear Recombination on Energy Transport in Semiconductors

Energy carrier transport and recombination in semiconductors can be directly monitored with optical microscopy, revealing key insights into fundamental photophysics and informs efficient optoelectronic device design. Oftentimes, energy transport is measured by monitoring a time-resolved expanding carrier profile after optical excitation under a focused laser beam. Although this approach has gained widespread adoption, the presence of competing dynamic processes, such as diffusion and photon recycling, has made it difficult to accurately extract and understand important semiconductor properties. Here, we develop and apply a new framework for modeling energy transport in both excitonic and free carrier semiconductors. Here, we demonstrate that processes such as nonlinear recombination and photon recycling can have a significant impact on the apparent energy carrier profiles, especially for excitonic materials with short radiative lifetimes. Additionally, we find that film microstructure can lead to unique transport profiles that strongly depends on material boundary behavior and the difference between feature size and diffusion length. Here, these findings provide a deeper understanding of energy transport in semiconducting materials and provide new strategies for the design and optimization of electronic and optoelectronic devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of synthetic electron cyclotron emission from the high field side of HL-2M tokamak plasmas

A synthetic electron cyclotron emission (ECE) diagnostic is used to interpret ECE signals from preset plasma equilibrium profiles, including magnetic field, electron density, and electron temperature. According to the simulation results, the electron temperature (T e ) profile covering the harmonic overlap region can be obtained by receiving ECE signals at the high field side (HFS) of the HL-2M plasma. The third harmonic ECE at the low field side (LFS) cannot pass through the second harmonic resonance layer at the HFS unless the optical thickness (τ) of the second harmonic becomes gray (τ ≤ 2). In addition, the impact of the relativistic frequency down-shift has been evaluated and corrected. The measurable range of the HFS ECE has been calculated by scanning different parameters (electron density, temperature, and magnetic field). Higher plasma parameters allow a wider radial range of electron temperature measurements. The minimum inner measurable position can reach R = 120 cm (r/a = -0.89) when the product of core temperature (T e0 ) and density (n e0 ) is greater than 35 × 10 19 keV m -3 , which is extended by more than 30 cm inward compared with that of the LFS measurement. The HFS ECE will greatly improve the diagnostic ability of ECE systems on the HL-2M tokamak.

47 OTHER INSTRUMENTATION↗

AI-driven neutrino diagnostics and radiation-hard beam instrumentation for next-generation neutrino experiments

The Long Baseline Neutrino Facility (LBNF) at Fermilab will deliver a high-intensity, multi-megawatt neutrino beam to the Deep Underground Neutrino Experiment (DUNE), enabling precision tests of the three-neutrino paradigm, CP violation searches, neutrino mass ordering determination, and supernova neutrino studies. To accelerate DUNE’s physics reach and ensure robust beam operations, we propose an integrated AI-driven framework with real-time diagnostics and radiation-hardened instrumentation. At its core is a Real-Time Beam Integrity Monitor using a physics-informed Digital Twin. By reconstructing pion phase space from muon profiles and exploiting magnetic horn optic linearity, it enables spill-by-spill beam correction and flux stabilization. By using this approach, flux-related systematics could be reduced from 5% to 1%, potentially accelerating the discovery of CP violations by four to six years. Complementing this, a US–Japan R&D effort will deploy a LAPPD-based muon monitor in the NuMI beamline. ToF measurements can be acquired with picosecond precision using this radiation-hard system, enhancing sensitivity to horn chromatic effects. Simulations confirm strong response to these effects. ML models predict beam quality and horn current to sub-percent accuracy from muon data, enhancing anomaly detection and stability. This scalable, AI-enabled strategy improves beam fidelity, reduces systematics, and sets a new standard for high-power accelerator operations.

Ganguly, Sudeshna [Fermilab] (ORCID:00000003163482↗

AI-driven neutrino diagnostics and radiation-hard beam instrumentation for next-generation neutrino experiments

The Long Baseline Neutrino Facility (LBNF) at Fermilab will deliver a high-intensity, multi-megawatt neutrino beam to the Deep Underground Neutrino Experiment (DUNE), enabling precision tests of the three-neutrino paradigm, CP violation searches, neutrino mass ordering determination, and supernova neutrino studies. To accelerate DUNE’s physics reach and ensure robust beam operations, we propose an integrated AI-driven framework with real-time diagnostics and radiation-hardened instrumentation. At its core is a Real-Time Beam Integrity Monitor using a physics-informed Digital Twin. By reconstructing pion phase space from muon profiles and exploiting magnetic horn optic linearity, it enables spill-by-spill beam correction and flux stabilization. By using this approach, flux-related systematics could be reduced from 5% to 1%, potentially accelerating the discovery of CP violations by four to six years. Complementing this, a US–Japan R&D effort will deploy a LAPPD-based muon monitor in the NuMI beamline. ToF measurements can be acquired with picosecond precision using this radiation-hard system, enhancing sensitivity to horn chromatic effects. Simulations confirm strong response to these effects. ML models predict beam quality and horn current to sub-percent accuracy from muon data, enhancing anomaly detection and stability. This scalable, AI-enabled strategy improves beam fidelity, reduces systematics, and sets a new standard for high-power accelerator operations.

Ganguly, Sudeshna [Fermilab] (ORCID:00000003163482↗

The PCM is Dead! Long Live O-PCM!

The ability to reconfigure the optical behavior of a device enables free-space applications ranging from imaging to sensing and signal control. Such optical devices can be compacted via meta-surfaces, patterned structures with feature sizes below the incident wavelength. Leveraging geometry in addition to material properties and CMOS fabrication techniques has allowed meta-surfaces for lenses, holograms, beam steerers and more. To incorporate multiple optical functions into one device, various methods of device control have been implemented, such as stretching of flexible substrates, tuning the refractive index of the comprising meta-atoms via the electro-optic or the thermo-optic effects, phase transition materials such as VO2 and more. Chalcogenide glasses used as optical phase change materials, such as Ge¬2Sb2Te5 (GST), have gained increased traction in the optics community for potential use in the near infrared (NIR) and mid infrared (MIR) bands, including the telecom bands. Various chalcogenides such as Sb2Se3, Sb2S3, Ge2Sb¬2Se5 and Ge2Sb2Se4Te (GSST) have been investigated due to their broad NIR or MIR transparency window and large changes in refractive index. In their amorphous phase, these materials usually display a lower refractive index and low absorption when compared to their crystalline state which display a higher refractive index and typically larger extinction coefficients. The amorphous-crystalline reversible switching can be done via fast melt-quenching thermal processes triggered by laser or electrical impulses, relying on a substrate as a heat sink. The potential of PCMs in photonic devices can be limited by intrinsic material limitations as well as by device fabrication issues. To explore the cyclability of GSST, a PCM with large refractive index contrast and on-chip electrothermal switching on a silicon-on-insulator platform has been done to analyze potential failure mechanisms from both a material and device perspective. A brief outline of the instrumentation and phase change contrast analysis is provided. Dewetting of the PCM, delamination of and damage in the PECVD SiNx protective layer, elemental migration in the PCM and optical contrast decay have been observed in cycled GSST devices. Guidelines for device performance improvement are proposed, and an improved design with larger endurance is shown in progress.

reconfigurable photonics↗

Further Development of Ko Displacement Theory for Deformed Shape Predictions of Nonuniform Aerospace Structures

The Ko displacement theory previously formulated for deformed shape predictions of nonuniform beam structures is further developed mathematically. The further-developed displacement equations are expressed explicitly in terms of geometrical parameters of the beam and bending strains at equally spaced strain-sensing stations along the multiplexed fiber-optic sensor line installed on the bottom surface of the beam. The bending strain data can then be input into the displacement equations for calculations of local slopes, deflections, and cross-sectional twist angles for generating the overall deformed shapes of the nonuniform beam. The further-developed displacement theory can also be applied to the deformed shape predictions of nonuniform two-point supported beams, nonuniform panels, nonuniform aircraft wings and fuselages, and so forth. The high degree of accuracy of the further-developed displacement theory for nonuniform beams is validated by finite-element analysis of various nonuniform beam structures. Such structures include tapered tubular beams, depth-tapered unswept and swept wing boxes, width-tapered wing boxes, and double-tapered wing boxes, all under combined bending and torsional loads. The Ko displacement theory, combined with the fiber-optic strain-sensing system, provide a powerful tool for in-flight deformed shape monitoring of unmanned aerospace vehicles by ground-based pilots to maintain safe flights.

Ko, William L.↗

Polar 5 - An electron accelerator experiment within an aurora. I - Instrumentation and geophysical conditions

A mother-daughter rocket was launched over two auroral structures, which included a 10 keV electron accelerator and a series of diagnostic instruments for monitoring optical and wave effects generated through beam-atmospheric interactions and production of secondary electrons. The instrumentation, the ground and rocket background measurements obtained, and some of the beam effects on various geophysical parameters are presented. Attention is given to the rocket geometry, capacitance probe, particle counters, photometers, and the bremsstrahlung X-ray detector. Observations on the plasma environment, auroral particle precipitation, d.c. electric field, optical emissions, and auroral background HF and VLF emissions are also discussed.

Maehlum, B. N.↗

Role of low-energy neutral N2 beam-surface interactions leading to spacecraft glow

Measurements of the optical spectra of surfaces undergoing bombardment by N2 and N2(+) in an ultrahigh vacuum environment provide information related to the origin of spacecraft flow and erosion. This work is complementary to other measurements, in which O and O(+) beams are utilized. These efforts are part of a broad program whose goal is the understanding of interactions between surfaces and low-energy charged and neutral particles.

Barnes, Alan V.↗

Advanced focusing system for secondary electrons in a bunch shape monitor

Non-destructive measurements of longitudinal beam profile in non-relativistic hadron accelerators are usually performed with Bunch Shape Monitors that utilize secondary electron emission to reproduce the shape of a primary ion beam. The existing devices, however, have poor electron collection efficiency from the wire and are limited to one dimensional measurements of the phase coordinate. Here, we present the development of a bunch shape monitor with improved performance for proton beams to be used in the Spallation Neutron Source accelerator. This improvement was achieved by adding focusing optics between the wire and the entrance slit, which will also allow measurements over a much higher dynamic range. Here we present the design, simulation and experimental test results of the developed new electron beam guidance system for the existing SNS bunch shape monitor that allowed significant improvement in the collection efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗