Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

SU-E-T-18: A Comparison of Planning Techniques for Bilateral Reconstructed Chest Wall Patients Undergoing Whole Breast Irradiation

Purpose: As we continuously see more bilateral reconstructed chest wall cases, new challenges are being presented to deliver left-sided breast irradiation. We herein compare three Deep Inspiration Breath Hold (DIBH) planning techniques (tangents, VMAT, and IMRT) and two free breathing techniques (VMAT and IMRT). Methods: Three left-sided chest wall patients with bilateral implants were studied. Tangents, VMAT, and IMRT plans were created for DIBH scans. VMAT and IMRT plans were created for free breathing scans. All plans were normalized so that 95% of the prescription dose was delivered to 95% of the planning target volume (PTV). The maximum point dose was constrained to less than 120% of the prescription dose. Since the success of DIBH delivery largely depends on patient’s ability to perform consistent breath hold during beam on time, smaller number of Monitor Units (MU) is in general desired. For each patient, the following information was collected to compare the planning techniques: heart mean dose, left and right lung V20 Gy, contra-lateral (right) breast mean dose, cord max dose, and MU. Results: The average heart mean dose over all patients are 1561, 692, 985, 1245, and 1121 cGy, for DIBH tangents, VMAT, IMRT, free breathing VMAT and IMRT, respectively. For left lung V20 are 60%, 28%, 26%, 30%, and 29%. For contra-lateral breast mean dose are 244, 687, 616, 783, 438 cGy. MU are 253, 853, 2048, 1035, and 1874 MUs. Conclusion: In the setting of bilateral chest wall reconstruction, opposed tangent beams cannot consistently achieve desired heart and left lung sparing. DIBH consistently achieves better healthy tissue sparing. VMAT appears to be preferential to IMRT for planning and delivering radiation to patients with bilaterally reconstructed chest walls being treated with DIBH.

60 APPLIED LIFE SCIENCES↗

Calibration plan for ultraviolet spectrometer experiment S169

The calibration test equipment presented is employed to calibrate completely assembled and flight-ready Apollo Ultraviolet Spectrometers (UVS) consisting of a vacuum system in which the UVS can be installed. In it a premonochromator produces a monochromatic beam at any desired wavelength from a UV source. This beam can be focused by an adjustable transfer mirror to any point on the entrance slit of the UVS. The transfer mirror can also direct the beam to one or both of two absolutely calibrated reference photomultiplier tubes to determine the number of photons which enter the UVS. A movable mirror rhomb is also provided to intermittently monitor the number of photons in the beam when the beam is centered on the entrance slit.

Source record↗

Development of a safe ground to space laser propagation system for the optical communications telescope laboratory

Furthering pursuits in high bandwidth communications to future NASA deep space and neat-Earth probes, the Jet Propulsion Laboratory (JPL) is building the Optical communications Telescope Laboratory (OCTL) atop Table Mountain in Southern California. This R&D optical antenna will be used to develop optical communication strategies for future optical ground stations. Initial experiments to be conducted include propagating high-powered, Q-switched laser beams to retro-reflecting satellites. Yet laser beam propagation from the ground to space is under the cognizance of various government agencies, namely: the Occupational Safety and Health Administration (ISHA) that is responsible for protecting workforce personnel; the Federal Aviation Administration (FAA) responsible for protecting pilots and aircraft; and the Laser Clearinghouse of Space Command responsible for protecting space assets. To ensure that laser beam propagation from the OCTL and future autonomously operated ground stations comply with the guidelines of these organizations, JPL is developing a multi-tiered safety system that will meet the coordination, monitoring, and reporting functions required by the agencies. At Tier 0, laser operators will meet OSHA safety standards for protection and access to the high power lasers area will be restricted and interlocked. Tier 1, the area defined from the telescope dome out to a range of 3.4-km, will utilize long wave infrared camera sensors to alert operators of at risk aircraft in the FAA controlled airspace. Tier 2, defined to extend from 3.4-km out to the aircraft service ceiling in FAA airspace, will detect at risk aircraft by radar. Lastly, beam propagation into space, defined as Tier 3, will require coordination with the Laser Clearinghouse. A detailed description of the four tiers is presented along with the design of the integrated monitoring and beam transmission control system.

laser safety↗

Reducing monitor units for robotic radiosurgery by optimized use of multiple collimators

Advances in image guidance and dose delivery techniques, and increased use of hypofractionation, have led to prolonged radiotherapy fraction duration. This is also the case with robotic radiosurgery, as extensive on-line image guidance procedures, many beams, and usually high fraction doses are used for tumor irradiation. At this institution, early stage non-small-cell lung cancer patients are treated with image guided tumor tracking for respiratory motion compensation. Approximately 130 circular beams and up to {approx}39 000 monitor units (MUs) are used for delivery of a total treatment dose of 60 Gy. The large number of MUs leads to long treatment times and the radiation leakage increases with the number of MUs. Generally, per patient, a single (small) cone is used. To substantially reduce the number of MUs, the authors have developed a new planning strategy for combined use of a small and a large cone. The large cone aims at dose delivery around the PTV center, while the small cone shapes the dose around the (irregular) PTV edges. The authors systematically investigated relationships between the number of MUs, the plan quality, the selected cone diameters, and the beam-direction setup. Plan quality was assessed with the conformity index, mean lung dose (MLD), V20 of the lungs, and by visual inspection. The reduction in MUs was determined by comparing two-cone plans with corresponding one-cone plans that yielded equal MLD, i.e., equal predicted lung toxicity. With the proposed two-cone approach, the required number of MUs reduced by on average 31% (range 4%-56%). The beam-on time per treatment fraction reduced by on average 8 min (range 1-15.2 min). All plans obeyed the clinically applied constraints and were considered clinically acceptable by an involved physician.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Finding Beam Loss Locations at PIP2IT Accelerator With Oscillating Dipole Correctors

The PIP2IT accelerator was assembled in multiple stages in 2014 - 2021 to test concepts and components of the future PIP-II linac that is being constructed at Fermilab. In its final configuration, PIP2IT accelerated a 0.55 ms x 20 Hz x 2 mA H- beam to 16 MeV. To determine location of the beam loss in the accelerators low-energy part, where radiation monitors are ineffective, a method using oscillating trajectories was implemented. If the beam is scraped at an aperture limitation, moving its centroid with two dipole correctors located upstream and oscillating in sync, produces a line at the corresponding frequency in spectra of BPM sum signals downstream of the loss point. Comparison of these responses along the beam line allows to find the loss location. The paper describes the method and results of its implementation at PIP2IT.

43 PARTICLE ACCELERATORS↗

A future for large space antennas

An investigation was conducted regarding the near-term applications of large aperture microwave antennas in space. The investigation had the objective to find out whether the initiation of a NASA development program concerning large space antennas would be justified. From a broad spectrum of possible uses for large atennas, those applications of interest to NASA were selected which singly or in aggregate appeared to offer significant benefits. Single point configuration studies were then conducted for promising applications. It was concluded that there are a number of applications which warrant an active program in large space antennas. The implementation of these applications will require a number of antenna types. The outward looking applications, such as radio astronomy and deep space communications, will be characterized by low noise receivers, single beams, and relatively slow scans. Earth-looking applications, such as radiometry for earth observations, spectrum monitoring, and terrestrial communications, will be characterized by high beam efficiency and multiple beams.

Powell, R. V.↗

SU-E-T-601: Patient Specific QA Check for Radiotherapy with Carbon Beam at SAGA HIMAT

Purpose: To verify a patient specific QA for a prescribed dose per monitor unit (MU) and range check of carbon ion radiotherapy with a beam wobbling method at SAGA HIMAT. Methods: The dose distribution in a water phantom was recalculated with a treatment plan made by XiO-N (Mitsubishi Electric Corporation, Tokyo). The depth dose distributions at central axis were compared with measurements using pinpoint ionization chamber (PTW31014). Measured data were analyzed for dose and distance difference with criteria of 3% and 2mm. To check for the MU and range, analysis data were used at center and distal end of a spread out bragg peak (SOBP) depth, respectively. Results: Treatment plan of 1400 beams in 500 patients were used for analysis. The pass rate of the MU and range was about 98% and 74%, respectively. The rate of both was 73%. The plan data passed only the MU check were verified depth dose profile. The data passed only the range and failed of both were compared depth dose distributions at off axis. If it was failed, we discussed with physicians. Conclusion: Most of patient specific QA check for a prescribed MU and range check at SAGA HIMAT were passed.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dynamic grazing incidence fast atom diffraction during molecular beam epitaxial growth of GaAs

A Grazing Incidence Fast Atom Diffraction (GIFAD) system has been mounted on a commercial molecular beam epitaxy chamber and used to monitor GaAs growth in real-time. In contrast to the conventionally used Reflection High Energy Electron Diffraction, all the GIFAD diffraction orders oscillate in phase, with the change in intensity related to diffuse scattering at step edges. We show that the scattered intensity integrated over the Laue circle is a robust method to monitor the periodic change in surface roughness during layer-by-layer growth, with oscillation phase and amplitude independent of incidence angle and crystal orientation. When there is a change in surface reconstruction at the start of growth, GIFAD intensity oscillations show that there is a corresponding delay in the onset of layer-by-layer growth. In addition, changes in the relative intensity of different diffraction orders have been observed during growth showing that GIFAD has the potential to provide insight into the preferential adatom attachment sites on the surface reconstruction during growth.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Understanding the formation and growth of Ag nanoparticles on silver chromate induced by electron irradiation in electron microscope: A combined experimental and theoretical study

Ag{sub 2}CrO{sub 4} microcrystals were synthesized using the co-precipitation method. These microcrystals were characterized through X-ray diffraction (XRD) with Rietveld analysis, field-emission scanning electron microscopy (FE-SEM), transmission electron microscopy (TEM) with energy-dispersive spectroscopy (EDS), micro-Raman (MR). XRD patterns and Rietveld refinement data showed that the material exhibits an orthorhombic structure without any deleterious phases. FE-SEM and TEM micrographs revealed the morphology and the growth of Ag nanoparticles on Ag{sub 2}CrO{sub 4} microcrystals during electron beam irradiation. These events were directly monitored in real-time. Their optical properties were investigated using ultraviolet-visible (UV–vis) diffuse reflectance spectroscopy that allowed the calculation of the optical band gap energy. Theoretical analyses based on the density functional theory level indicate that the incorporation of electrons is responsible for structural modifications and formation of defects on the [AgO{sub 6}] and [AgO{sub 4}] clusters, generating ideal conditions for the growth of Ag nanoparticles. - Graphical abstract: Theoretical representation of the Ag{sub 2}CrO{sub 4} orthorhombic structure. Display Omitted - Highlights: • The Ag{sub 2}CrO{sub 4} microcrystals indicate an orthorhombic structure. • The formation of Ag{sup 0} promotes Ag-nanoparticle growth on the surface of the Ag{sub 2}CrO{sub 4}. • Electron irradiation of the material induces the formation of Ag vacancies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-T-66: A Prototype for Couch Based Real-Time Dosimetry in External Beam Radiotherapy

Purpose: The main purpose of this study is to design a prototype for couch-based based real time dosimetry system in external beam radiotherapy Methods: A prototype of 100 ionization chambers was designed on a printed circuit board by etching the copper layer and each ionization chamber was wired to a 50 pin connector. The signals from the two 50 pin connectors collected from the ionization chambers were then transferred to a PXI module from National Instruments. The PXI module houses a current amplifier that amplifies the charge collected from the ionization chamber. The amplified signal is then sent to a digital multimeter module for converting the analog signal to digital signal. A software was designed in labview to read and display the signals obtained from the PXI module. A couch attachment frame was designed to house the 100 ionization chamber module. The frame was fixed underneath the treatment couch for measuring the dose during treatment. Resutls: The ionization chamber based prototype dosimetry was tested for simple radiotherapy treatment fields and found to be a useful device for measuring real time dosimetry at the treatment couch plane. This information could be used to assess the delivered dose to a patient during radiotherapy. It could be used as an invivo dosimeter during radiotherapy. Conclusion: In this study, a prototype for couch based real time dosimetry system was designed and tested. The prototype forms a basis for the development of large scale couch based real time dosimetry system that could be used to perform morning QA prior to treatment, assess real time doses delivered to patient and as a device to monitor the output of the treatment beam. Peter MacCallum Cancer Foundation.

60 APPLIED LIFE SCIENCES↗

High-power laser interaction with low-density C–Cu foams

Here, we study the propagation of high-power laser beams in micro-structured carbon foams by monitoring the x-ray output from deliberately introduced Cu content. In particular, we characterize this phenomenon measuring absolute time-resolved x-ray yields, time-resolved x-ray imaging, and x-ray spectroscopy. New experimental results for C–Cu foams show a faster heat front velocity than simulation that assumed homogeneous plasma. We suggest the foam micro-structure may explain this trend.

42 ENGINEERING↗

SwissFEL instrument ESB femtosecond pump-probe diffraction and scattering

The ESB instrument at the SwissFEL ARAMIS hard X-ray free electron laser is designed to perform pump-probe experiments in condensed matter and material science employing photon-in and photon-out techniques. It includes a femtosecond optical laser system to generate a variety of pump beams, a X-ray optical scheme to tailor the X-ray probe beam, shot-to-shot diagnostics to monitor the X-ray intensity and arrival time, and two endstations operated at a single focus position that include multi-purpose sample environments and 2D pixel detectors for data collection.

43 PARTICLE ACCELERATORS↗

Engineering catalytic activity via ion beam bombardment of catalyst supports for vertically aligned carbon nanotube growth

Carbon nanotube growth depends on the catalytic activity of metal nanoparticles on alumina or silica supports. The control on catalytic activity is generally achieved by variations in water concentration, carbon feed, and sample placement on a few types of alumina or silica catalyst supports obtained via thin film deposition. We have recently expanded the choice of catalyst supports by engineering inactive substrates like c-cut sapphire via ion beam bombardment. The deterministic control on the structure and chemistry of catalyst supports obtained by tuning the degree of beam-induced damage have enabled better regulation of the activity of Fe catalysts only in the ion beam bombarded areas and hence enabled controllable super growth of carbon nanotubes. A wide range of surface characterization techniques were used to monitor the catalytically active surface engineered via ion beam bombardment. The proposed method offers a versatile way to control carbon nanotube growth in patterned areas and also enhances the current understanding of the growth process. As a result, with the right choice of water concentration, carbon feed and sample placement, engineered catalyst supports may extend the carbon nanotube growth yield to a level that is even higher than the ones reported here, and thus offers promising applications of carbon nanotubes in electronics, heat exchanger, and energy storage.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Quantum state specific reactant preparation in a molecular beam by rapid adiabatic passage

Highly efficient preparation of molecules in a specific rovibrationally excited state for gas/surface reactivity measurements is achieved in a molecular beam using tunable infrared (IR) radiation from a single mode continuous wave optical parametric oscillator (cw-OPO). We demonstrate that with appropriate focusing of the IR radiation, molecules in the molecular beam crossing the fixed frequency IR field experience a Doppler tuning that can be adjusted to achieve complete population inversion of a two-level system by rapid adiabatic passage (RAP). A room temperature pyroelectric detector is used to monitor the excited fraction in the molecular beam and the population inversion is detected and quantified using IR bleaching by a second IR-OPO. The second OPO is also used for complete population transfer to an overtone or combination vibration via double resonance excitation using two spatially separated RAP processes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantitative assessment of the accuracy of dose calculation using pencil beam and Monte Carlo algorithms and requirements for clinical quality assurance

To compare the doses calculated using the BrainLAB pencil beam (PB) and Monte Carlo (MC) algorithms for tumors located in various sites including the lung and evaluate quality assurance procedures required for the verification of the accuracy of dose calculation. The dose-calculation accuracy of PB and MC was also assessed quantitatively with measurement using ionization chamber and Gafchromic films placed in solid water and heterogeneous phantoms. The dose was calculated using PB convolution and MC algorithms in the iPlan treatment planning system from BrainLAB. The dose calculation was performed on the patient's computed tomography images with lesions in various treatment sites including 5 lungs, 5 prostates, 4 brains, 2 head and necks, and 2 paraspinal tissues. A combination of conventional, conformal, and intensity-modulated radiation therapy plans was used in dose calculation. The leaf sequence from intensity-modulated radiation therapy plans or beam shapes from conformal plans and monitor units and other planning parameters calculated by the PB were identical for calculating dose with MC. Heterogeneity correction was considered in both PB and MC dose calculations. Dose-volume parameters such as V95 (volume covered by 95% of prescription dose), dose distributions, and gamma analysis were used to evaluate the calculated dose by PB and MC. The measured doses by ionization chamber and EBT GAFCHROMIC film in solid water and heterogeneous phantoms were used to quantitatively asses the accuracy of dose calculated by PB and MC. The dose-volume histograms and dose distributions calculated by PB and MC in the brain, prostate, paraspinal, and head and neck were in good agreement with one another (within 5%) and provided acceptable planning target volume coverage. However, dose distributions of the patients with lung cancer had large discrepancies. For a plan optimized with PB, the dose coverage was shown as clinically acceptable, whereas in reality, the MC showed a systematic lack of dose coverage. The dose calculated by PB for lung tumors was overestimated by up to 40%. An interesting feature that was observed is that despite large discrepancies in dose-volume histogram coverage of the planning target volume between PB and MC, the point doses at the isocenter (center of the lesions) calculated by both algorithms were within 7% even for lung cases. The dose distributions measured with EBT GAFCHROMIC films in heterogeneous phantoms showed large discrepancies of nearly 15% lower than PB at interfaces between heterogeneous media, where these lower doses measured by the film were in agreement with those by MC. The doses (V95) calculated by MC and PB agreed within 5% for treatment sites with small tissue heterogeneities such as the prostate, brain, head and neck, and paraspinal tumors. Considerable discrepancies, up to 40%, were observed in the dose-volume coverage between MC and PB in lung tumors, which may affect clinical outcomes. The discrepancies between MC and PB increased for 15 MV compared with 6 MV indicating the importance of implementation of accurate clinical treatment planning such as MC. The comparison of point doses is not representative of the discrepancies in dose coverage and might be misleading in evaluating the accuracy of dose calculation between PB and MC. Thus, the clinical quality assurance procedures required to verify the accuracy of dose calculation using PB and MC need to consider measurements of 2- and 3-dimensional dose distributions rather than a single point measurement using heterogeneous phantoms instead of homogenous water-equivalent phantoms.

61 RADIATION PROTECTION AND DOSIMETRY↗

Listening to Radiation Damage In Situ: Passive and Active Acoustic Techniques

Knowing when, why, and how materials evolve, degrade, or fail in radiation environments is pivotal to a wide range of fields from semiconductor processing to advanced nuclear reactor design. A variety of methods, including optical and electron microscopy, mechanical testing, and thermal techniques, have been used in the past to successfully monitor the microstructural and property evolution of materials exposed to extreme radiation environments. Acoustic techniques have also been used in the past for this purpose, although most methodologies have not achieved widespread adoption. However, with an increasing desire to understand microstructure and property evolution in situ, acoustic methods provide a promising pathway to uncover information not accessible to more traditional characterization techniques. This work highlights how two different classes of acoustic techniques may be used to monitor material evolution during in situ ion beam irradiation. The passive listening technique of acoustic emission is demonstrated on two model systems, quartz and palladium, and shown to be a useful tool in identifying the onset of damage events such as microcracking. An active acoustic technique in the form of transient grating spectroscopy is used to indirectly monitor the formation of small defect clusters in copper irradiated with self-ions at high temperature through the evolution of surface acoustic wave speeds. Here, these studies together demonstrate the large potential for using acoustic techniques as in situ diagnostics. Such tools could be used to optimize ion beam processing techniques or identify modes and kinetics of materials degradation in extreme radiation environments.

36 MATERIALS SCIENCE↗

Hybrid Automated Diagnosis of Discrete/Continuous Systems

A recently conceived method of automated diagnosis of a complex electromechanical system affords a complete set of capabilities for hybrid diagnosis in the case in which the state of the electromechanical system is characterized by both continuous and discrete values (as represented by analog and digital signals, respectively). The method is an integration of two complementary diagnostic systems: (1) beacon-based exception analysis for multi-missions (BEAM), which is primarily useful in the continuous domain and easily performs diagnoses in the presence of transients; and (2) Livingstone, which is primarily useful in the discrete domain and is typically restricted to quasi-steady conditions. BEAM has been described in several prior NASA Tech Briefs articles: "Software for Autonomous Diagnosis of Complex Systems" (NPO-20803), Vol. 26, No. 3 (March 2002), page 33; "Beacon-Based Exception Analysis for Multimissions" (NPO-20827), Vol. 26, No. 9 (September 2002), page 32; "Wavelet-Based Real-Time Diagnosis of Complex Systems" (NPO-20830), Vol. 27, No. 1 (January 2003), page 67; and "Integrated Formulation of Beacon-Based Exception Analysis for Multimissions" (NPO-21126), Vol. 27, No. 3 (March 2003), page 74. Briefly, BEAM is a complete data-analysis method, implemented in software, for real-time or off-line detection and characterization of faults. The basic premise of BEAM is to characterize a system from all available observations and train the characterization with respect to normal phases of operation. The observations are primarily continuous in nature. BEAM isolates anomalies by analyzing the deviations from nominal for each phase of operation. Livingstone is a model-based reasoner that uses a model of a system, controller commands, and sensor observations to track the system s state, and detect and diagnose faults. Livingstone models a system within the discrete domain. Therefore, continuous sensor readings, as well as time, must be discretized. To reason about continuous systems, Livingstone uses monitors that discretize the sensor readings using trending and thresholding techniques. In development of the a hybrid method, BEAM results were sent to Livingstone to serve as an independent source of evidence that is in addition to the evidence gathered by Livingstone standard monitors. The figure depicts the flow of data in an early version of a hybrid system dedicated to diagnosing a simulated electromechanical system. In effect, BEAM served as a "smart" monitor for Livingstone. BEAM read the simulation data, processed the data to form observations, and stored the observations in a file. A monitor stub synchronized the events recorded by BEAM with the output of the Livingstone standard monitors according to time tags. This information was fed to a real-time interface, which buffered and fed the information to Livingstone, and requested diagnoses at the appropriate times. In a test, the hybrid system was found to correctly identify a failed component in an electromechanical system for which neither BEAM nor Livingstone alone yielded the correct diagnosis.

Park, Han↗

Abnormal Slow Phonon Dynamics Toward Prolonging Excited States Dynamics Enabled by Crystalline‐Assembling Donor–Acceptor Molecules

Phonon dynamics are a critical factor to control the optical properties of excited states in light-emitting materials. Here, we report an extremely slow relaxation of photoexcited lattice vibrations enabled by assembling the donor-acceptor (D–A) molecules [2-(9,9-dimethylacridin-10(9H)-yl)-9,9-dimethyl-9H-thioxanthene 10,10-dioxide], namely AC molecules, into dipolar crystal. By using photoexcitation-modulated Raman spectroscopy, we find that the crystalline-lattice vibrations monitored by Raman-scattering laser beam of 785 nm demonstrate an un-usual slow relaxation in the time scale of seconds after ceasing photoexcitation beam of 343 nm in such dipolar crystal. This presents extremely slow phonon dynamics enabled by crystalline-assembling the D–A molecules into a dipolar crystal. Simultaneously, the photoluminescence (PL) exhibits a prolonged behavior, lasting 10 ms after ceasing photoexcitation in dipolar AC crystal. This phenomenon provides an experimental hypothesis that the slow phonon dynamics function as an important mechanism to unusually prolong excited states dynamics upon crystalline-assembling the D–A molecules into dipolar crystal. Here, this hypothesis can be verified by directly suppressing the phonon dynamics through freezing D–A molecular liquid into dipolar crystalline solid at 77 K to largely prolong the PL to 1 s- after removing photoexcitation. Clearly, crystalline-assembling D–A molecules provide the necessary conditions to enable slow phonon dynamics toward prolonging excited states dynamics.

36 MATERIALS SCIENCE↗