Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BASE PRESSURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Ventilation Heat Exchanger / Flow Meter for xPLSS

The flow meter / heat exchanger (FMHX) in the ventilation loop of the exploration EMU cools the ventilation gas and measures the ventilation flow rate. The heat exchanger transfers heat from the ventilation gas to the thermal control loop via a miniature shell-and-tube heat exchanger. The flow meters calculate the flow rate of gas through the ventilation loop based on the pressure drop across the heat exchanger core. Creare has delivered four design validation test (DVT) heat exchangers and five DVT flow meters to NASA JSC to support development of the exploration portable life support system (xPLSS). This paper describes the design and performance of the DVT units.The heat exchangers are designed to cool the ventilation gas to a specified temperature with low pressure losses under the most challenging operating conditions. The measured performance of the DVT heat exchangers agrees well with design models and meets all performance requirements. The flow meters use a MEMS thermal flow sensor to produce a signal that is proportional to a small bypass flow around the heat exchanger core. They are designed to achieve high measurement accuracy across the full range of xPLSS operating conditions. We calibrated the flow meters in a special-purpose flow facility that simulates operation in the xPLSS ventilation loop. Calibration testing shows that DVT flow meters produce digital output for vent loop mass flow that meets NASA’s accuracy requirements across the range of xPLSS operating conditions. This paper reviews the design of the heat exchangers and flow meters and presents data from the final flow meter calibration testing, heat exchanger performance validation, and initial ground testing in NASA’s xPLSS.

spacesuit↗

Ventilation Heat Exchanger / Flow Meter for xPLSS

The flow meter / heat exchanger (FMHX) in the ventilation loop of the exploration EMU cools the ventilation gas and measures the ventilation flow rate. The heat exchanger transfers heat from the ventilation gas to the thermal control loop via a miniature shell-and-tube heat exchanger. The flow meters calculate the flow rate of gas through the ventilation loop based on the pressure drop across the heat exchanger core. Creare has delivered four design validation test (DVT) heat exchangers and five DVT flow meters to NASA JSC to support development of the exploration portable life support system (xPLSS). This paper describes the design and performance of the DVT units.The heat exchangers are designed to cool the ventilation gas to a specified temperature with low pressure losses under the most challenging operating conditions. The measured performance of the DVT heat exchangers agrees well with design models and meets all performance requirements. The flow meters use a MEMS thermal flow sensor to produce a signal that is proportional to a small bypass flow around the heat exchanger core. They are designed to achieve high measurement accuracy across the full range of xPLSS operating conditions. We calibrated the flow meters in a special-purpose flow facility that simulates operation in the xPLSS ventilation loop. Calibration testing shows that DVT flow meters produce digital output for vent loop mass flow that meets NASA’s accuracy requirements across the range of xPLSS operating conditions. This paper reviews the design of the heat exchangers and flow meters and presents data from the final flow meter calibration testing, heat exchanger performance validation, and initial ground testing in NASA’s xPLSS.

spacesuit↗

Application of Machine Learning Techniques in Calibration and Data Reduction of Multi-Hole Probes

This work presents procedures to implement machine learning methods in the existing algorithms for multi-hole probe calibrations and data reduction. It is shown here, that utilizing artificial neural networks (ANNs) can reduce the amount of calibration data that needs to be acquired in order to obtain a specific calibration uncertainty, by more than 50% while simultaneously reducing data reduction times significantly. ANNs were used instead of the surface fitting methods, where first, the directional calibration coefficients related to the flow angles are calculated based on the pressure measurements, and then the flow angles are used as a set of the input parameters for the following ANNs to define Mach number and static and total pressure iteratively. In a second approach, novel calibration coefficients were used to directly relate the pressure measurements from five-hole probe to the quantities of interest thus, eliminating the need for iterative algorithms used in the conventional surface fitting methods. The advantageous features of this method are an average increase of less than 1% in the calibration uncertainty for flow angles and significant reduction of the data reduction times (few seconds). In addition, we confirmed the methodology to avoid over-fitting and under-fitting.

Machine Learning↗

Evaluating the Feasibility of Using Strain Measured During Sinusoidal Rate Pumping Tests to Characterize an Aquifer

Pumping tests with sinusoidal variation in pumping rate have been proposed as a method for improving aquifer characterization. These tests can interrogate a larger aquifer volume than slug tests and they can be more sensitive to small variations in drawdown. Current methods of using sinusoidal variations of rate are based on measuring pressure signals from the reservoir or aquifer, which requires access to monitoring wells. An alternative approach has been developed that measures the strain in the vadose zone instead of pressure in the reservoir. An instrument has been developed at Clemson University that can measure small strains using optical fiber sensors, and we propose that it can be used to measure strain during sinusoidal pumping tests. The objective of this project is to evaluate the feasibility of measuring and interpreting the vertical strain in the vadose zone generated during a sinusoidal rate pumping tests to estimate aquifer and/or overburden properties. Pumping tests were performed at a site with a water table at 9 m and saturated saprolite from 9 to 30m depth. Sinusoidal pumping tests in the saprolite used different pumping amplitudes and periods while pressure was measured at three piezometers and vertical strain was measured in the vadose zone from 1 to 7 m depth. The delay time of the pressure increased linearly with distance, and it increased with the square root of the period, while the amplitude of the pressure decreased with distance and increased with amplitude. Vertical strain in the vadose zone varied with the same period as the pumping rate and the delay times were similar to those for pressures measured at similar radial distances. Delay times for the strain increased with an increasing propagation of the strain field. The hydraulic diffusivity was estimated using delay times for pressure and strain, and the results were compared with the values estimated from a constant-rate pumping test. The hydraulic diffusivity from the constant rate test was 0.039 m2/sec, whereas it was 0.053 (±0.05) m2/sec and 0.035 (±0.03) m2/sec from the pressure data and 0.08 (±0.022) m2/sec and 0.035 (±0.001) m2/sec from the strain data from sinusoidal tests of various periods and amplitudes. There is no statistical difference among these values. This study indicates that strain measurements in the vadose zone can be used to estimate aquifer properties during sinusoidal pumping tests.

Blais, Riley↗

Laboratory and In-Pile Testing of a Fiber Optic Pressure Sensor

The development, testing and deployment of a fiber-optic-based extrinsic Fabry-Perot pressure sensor is discussed. The details of design and fabrication procedure is discussed and the methodology for design decisions is provided. Results from laboratory-based testing and calibration is provided as-well-as preliminary data from in-pile testing in the Transient Reactor Test Facility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-Time Dynamic Brake Assessment Proof of Concept Final Report

This proof-of-concept research was performed to explore the feasibility of using real-world braking data from commercial motor vehicles to make a diagnosis of brake condition similar to that of the performance-based brake tester (PBBT). This was done by determining the relationship between pressure and brake force (P-BF), compensating for the gross vehicle weight (GVW). The nature of this P-BF relationship (e.g., low braking force for a given brake application pressure) may indicate brake system problems. In order to determine the relationship between brake force and brake application pressure, a few key parameters of duty cycle information were collected. Because braking events are often brief, spanning only a few seconds, a sample rate of 10 Hz was needed. The algorithm under development required brake application pressure and speed (from which deceleration was calculated). Accurate weight estimation was also needed to properly derive the braking force from the deceleration. In order to ensure that braking force was the predominant factor in deceleration for the segments of data used in analysis, the data was screened for grade as well. Also, the analysis needed to be based on pressures above the crack pressure. The crack pressure is the pressure below which the individual brakes are not applied due the nature of the mechanical system. This value, which may vary somewhat from one wheel end to another, is approximately 10 psi. Therefore, only pressures 15 psi and above were used in the analysis. The Department of Energy s Medium Truck Duty Cycle research has indicated that under the real-world circumstances of the test vehicle brake pressures of up to approximately 30 psi can be expected. Several different types of data were collected during the testing task of this project. Constant-pressure stopping tests were conducted at several combinations of brake application pressure (15, 20, 25, and 30 psi), load conditions (moderately and fully laden), and speeds (20 and 30 mph). Data was collected at 10 Hz. Standard and stepped-pressure performance-based brake tests with brake pressure transducers were performed for each loading condition. The stepped-pressure test included the constant-pressure intervals of brake application at 15, 20, 25, and 30 psi. The PBBT data files included 10 Hz streaming data collected during the testing of each axle. Two weeks of real-world duty cycle (driving and braking) data was also collected at 10 Hz. Initial analysis of the data revealed that the data collected in the field (i.e., day-to-day operations) provided the same information as that obtained from the controlled tests. Analysis of the data collected revealed a strong linear relationship between brake application pressure and deceleration for given GVWs. As anticipated, initial speed was not found to be a significant factor in the deceleration-pressure relationship, unlike GVW. The positive results obtained from this proof of concept test point to the need for further research to expand this concept. A second phase should include testing over a wider range of speeds and include medium brake application pressures in addition to the low pressures tested in this research. Testing on multiple vehicles would also be of value. This future phase should involve testing to determine how degradation of braking performance affects the pressure-deceleration relationship.

99 GENERAL AND MISCELLANEOUS↗

Feasibility study of measuring the temperature and pressure of warm dense matter.

We have investigated the feasibility of making accurate measurements of the temperature and pressure of solid-density samples rapidly heated by the Z-Petawatt laser to warm dense matter (WDM) conditions, with temperatures approaching 100eV. The study focused specifically on the heating caused by laser generated proton beams. Based on an extensive literature search and numerical investigations, a WDM experiment is proposed which will accurately measure temperature and pressure based on optical emission from the surface and sample expansion velocity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of fluid physics effects on cardiovascular response to microgravity (G-572)

The recognition and understanding of cardiovascular adaptation to spaceflight has experienced substantial advancement in the last several years. In-flight echocardiographic measurements of astronaut cardiac function on the Space Shuttle have documented a 15 percent reduction in both left ventricular volume index and stroke volume with a compensatory increase in heart rate to maintain cardiac output. To date, the reduced cardiac size and stroke volume have been presumed to be the consequence of the reduction in circulating fluid volume following diuresis and other physiological processes to reduce blood volume within a few days after orbital insertion. However, no specific mechanism for the reduced stroke volume has been elucidated. The following investigation proposes the use of a hydraulic model of the cardiovascular system to examine the possibility that the observed reduction in stroke volume may, in part, be related to fluid physics effects on heart function. The automated model is being prepared to fly as a GAS payload. The experimental apparatus consists of a pneumatically actuated, elliptical artificial ventricle connected to a closed-loop, hydraulic circuit with compliance and resistance elements to create physiologic pressure and flow conditions. The ventricle is instrumented with high-fidelity, acceleration-insensitive, catheter-tip pressure transducers (Millar Instruments) in the apex and base to determine the instantaneous ventricular pressures and (delta)P(sub LV) across the left ventricle (LVP(sub apex)-LVP(sub base). The ventricle is also instrumented with a flow probe and pressure transducers immediately upstream of the inflow valve and downstream of the outflow valve. The experiment will be microprocessor controlled with analog signals stored on the FM data tape recorder. By varying the circulating fluid volume, ventricular function can be determined for varying preload pressures with fixed afterload pressure. Pilot experiments on board the NASA KC-135 aircraft have demonstrated proof-of-concept and provided early support for the proposed hypothesis. A review of the pilot experiments and developmental progress on the GAS version of this experiment will be presented.

Pantalos, George M.↗

Refrigerator Based on Chemisorption

Reversible chemical reaction generates pressurized oxygen for cooling. Concept for cryogenic refrigerator based on chemical absorption of oxygen by praseodymium/cerium oxide (PCO) compound. Refrigerator produces cryogenic liquid for cooling infrared sensors. Also used for liquefying air and separating oxygen from nitrogen in air. In chemisorption refrigerator, PCO alternately absorbs and desorbs oxygen depending on whether cooled or heated. One pair of compressors accepts oxygen while others releases it. Compressed oxygen liquefied when precooked and expanded.

Jones, Jack A.↗

Assessment of asymmetrical rheological behavior of cementitious material for 3D printing application

Among the multiplicity of construction methods based on digital concrete technologies, the most common one remains the extrusion-based process. Two opposed strategies have been developed in order to print a concrete structure using extrusion: the first one emphasizes the ease-of-pumping of material which is massively accelerated to ensure the stability of the structure, when leaving the extruder; the second one uses a firm mortar able to sustain the own weight of the structure during the printing, without requiring any accelerator. Both methods have their pros and cons and don't imply the same rheological requirements. Most of the recent literature assumes that both types of material (fluid and firm) follow the same trend of behavior and obey to the Von Mises plasticity criterion, while it has been demonstrated that firm cement-based materials can exhibit a pressure dependent behavior. Moreover, rheological study is mainly based on shear rheometry, while the extrusion-based printing process requires a description of the rheological behavior in compression to predict the global stability of the structure, and in tension to prevent cracks formation. This paper investigates the fresh behavior of cement paste and mortar under different solicitations (shear, compression, tension) for different water to cement ratios. The analysis of these results allows to describe the transition between a ductile fluid material (symmetrical in tension and compression) that obeys to a Von Mises plasticity criterion, and a brittle and firm material (asymmetrical in tension and compression) that requires a pressure dependent plasticity criterion in order to predict its strength under a given solicitation.

36 MATERIALS SCIENCE↗

Note: Theoretical study on the gas pressure dependence of x-ray yield in TE{sub 111} cavity based electron cyclotron resonance x-ray source

Adopting Langevin methodology, a pressure dependent frictional force term which represents the collisional effect is added to the Lorentz equation. The electrons are assumed to be starting from the uniformly distributed co-ordinates on the central plane. The trajectory of each electron is numerically simulated by solving the modified Lorentz equation for a given pressure. The Bremsstrahlung x-ray energy spectrum for each electron crossing the cavity wall boundary is obtained using the Duane-Hunt law. The total x-ray yield is estimated by adding the spectral contribution of each electron. The calculated yields are compared with the experimental results and a good agreement is found.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A kernel function method for computing steady and oscillatory supersonic aerodynamics with interference.

The method presented uses a collocation technique with the nonplanar kernel function to solve supersonic lifting surface problems with and without interference. A set of pressure functions are developed based on conical flow theory solutions which account for discontinuities in the supersonic pressure distributions. These functions permit faster solution convergence than is possible with conventional supersonic pressure functions. An improper integral of a 3/2 power singularity along the Mach hyperbola of the nonplanar supersonic kernel function is described and treated. The method is compared with other theories and experiment for a variety of cases.

Cunningham, A. M., Jr.↗

Effect of Applied Stress on the Selective Oxidation of Alloy 600 Exposed to PWR Primary Water and Rhines Pack Environments

A mechanistic understanding of corrosion and oxidation processes is crucial to ensure long-term resistance to stress corrosion cracking of Ni-base structural alloys in pressurized water reactor (PWR) primary and secondary systems. Aqueous corrosion of Ni-base alloys under PWR primary water conditions was previously compared to gaseous oxidation with comparable oxygen potentials. However, those studies considered only stress-free conditions, which removes a critical parameter for understanding stress corrosion behaviors. A significant knowledge gap exists for the role of applied stresses on selective internal oxidation in gaseous environments. A micro-4-point-bend jig was designed to facilitate stress in a Rhines Pack set-up. Selective oxidation at different stress and strain conditions was investigated in a series of Rhines Pack experiments for Alloy 600. Focused ion beam milling enabled the extraction of site-specific specimens containing selected high-energy grain boundaries from tensile and compressive stress regions. Analytical transmission electron microscopy was employed to analyze the microstructure and chemical composition of the resulting oxides. Protective surface oxide films and selective intergranular oxides were observed at different conditions. The implications of these fundamental differences are discussed relative to intergranular attack and stress corrosion cracking mechanisms in PWR primary water.

stress, 4-point-bend, selective oxidation, Alloy 6↗

The MOOSE fluid properties module

The fluid properties module in MOOSE~\cite{lindsay2022moose} serves a variety of fluid simulation applications based on MOOSE, including the MOOSE Navier Stokes module~\cite{moose_ns}, Pronghorn~\cite{pgh}, the MOOSE thermal hydraulics module, SAM~\cite{sam}, RELAP-7~\cite{relap7}, Sockeye~\cite{sockeye}, Pronghorn-subchannel~\cite{subchannel} and the MOOSE porous flow module~\cite{porous}. These applications are used to solve coarse mesh multi-dimensional thermal-hydraulics~\cite{pgh}, 1D systems analysis~\cite{sam,relap7} in nuclear reactor analysis, heat pipe modeling~\cite{sockeye} and porous flow simulations~\cite{porous} for underground gas storage and water seepage. The use of consistent fluid properties across fluid flow applications facilitates coupled flow simulations~\cite{anl_sam_pgh,osti_1889653}. Each application has historically driven the implementation of several fluid properties, which were later extended to be compatible with other applications. The unique diversity of applications of the module, due to its presence in MOOSE, has driven its expansion to new fluids, such as advanced nuclear reactor coolants and, more recently, arbitrary functions or tables-based property definitions, as detailed in section~\ref{content}, as well as numerous thermophysical properties and variable sets, as detailed in subsection~\ref{sec:prop}. The need for different discretizations of flow equations based on the compressibility of the fluid has motivated support for both primitive (pressure- and temperature-based) and conservative (internal energy- and specific volume-based) flow variables in the module. Thermodynamic relations are used to convert between these two formulations, as needed. The module serves a dual purpose of providing fluid properties for direct use in flow simulations and facilitating the implementation of user-specific fluid properties. Contributions of new properties for existing fluids or new fluids are strongly encouraged.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Effects of interlayer spacing and applied pressure on the lanthanide transport in MoS 2 -based two-dimensional channels

Rare-earth elements (REEs) are critical to modern industry but difficult to separate due to their subtle and monotonic changes in physicochemical properties. MoS 2 -based two-dimensional (2D) materials offer novel opportunities for enhancing REE separation, exhibiting a distinct volcano-shaped transport performance distribution that peaks at Sm 3+ . However, the specific contributions of thermodynamic and kinetic factors to ion transport within 2D confinement remain unclear. In this study, we conducted a series of non-equilibrium all-atom molecular dynamics (MD) simulations to explore the effects of interlayer spacing and external pressure on the transport of lanthanide ions in Å-scale acetate functionalized 2D MoS 2 (MoS 2 -COOH) channels. We examined ion entry and permeation rates, water flux, dehydration, and binding modes. The simulation results reveal that the transport trends of lanthanide ions are jointly driven by the dehydration degree and the relative-binding strengths of ions to water and to the acetate within the 2D channels. Notably, the dehydration pattern of lanthanide ions during permeation is closely linked to kinetic factors. Overall, this study provides a detailed atomistic understanding of the mechanisms underlying lanthanide ion transport under confinement. These findings point to the significant potential for tuning confinement and chemical functionalization within Å-scale channels for more efficient REE separation.

2D channels↗

Mooring and Seafloor Pressure End Point Measurements at the Southern Entrance of the Solomon Sea: Subseasonal to Interannual Flow Variability

Variability of the flow across the Solomon Sea's southern entrance was examined using end point subsurface moorings and seafloor pressure sensors, reconstructed velocity profiles based on satellite-derived surface velocity and bottom pressure-derived subsurface velocity, and 1993–2017 proxy volume transport based on satellite altimetry. The reconstructed velocity correctly represents the fluctuating surface flow and subsurface core providing a high-frequency continuous observing system for this sea. The mean equatorward volume transport over 0- to 500-m depth layer is 15.2 Sv (1 Sv ≡ 106 m3/s) during July 2012 to May 2017. The measurements resolve the full spectrum of the volume transport including energetic subseasonal variability that fluctuates by as much as 25 Sv over one week. At low-frequency timescales, the study finds that linear Rossby waves forced by Ekman pumping in the interior of the Pacific influence not only seasonal fluctuations as found by previous studies but also interannual variability. As found previously, the El Niño–Southern Oscillation highly influences interannual volume transport. During the 2015/2016 El Niño, observations show the seasonal cycle to be suppressed from the second half of 2014, prior to the mature phase of the El Niño, to September 2016 along with an increase in across-transect transport. At subseasonal timescales, local Ekman pumping and remote wind stress curl are responsible for a third of the subseasonal variance. Finally, the study highlights the importance of high-frequency observations at the southern entrance of the Solomon Sea and the ability of a linear Rossby model to represent the low-frequency variability of the transport.

54 ENVIRONMENTAL SCIENCES↗

A dynamic pressure calibration standard

A dynamic pressure calibration standard has been developed for calibrating flush diaphragm mounted pressure transducers. Pressures up to 20 kPa (3 psi) have been accurately generated over a frequency range of 50 to 1800 hz. The uncertainty of the standard is +/-5 pct to 5kPa (.75 psi) and +/-10 pct from 5 kPa (.75 psi) to 20 kPa (3 psi). The system consists of two conically shaped, aluminum columns, one 5 cm (2 in.) high for low pressures and another 11 cm (4.3 in.) high for higher pressures, each filled with a viscous fluid. A column is mounted on the armature of a vibration exciter which imparts a sinusoidally varying acceleration to the fluid column. Two pressure transducers mounted at the base of the column sense the sinusoidally varying pressure. This pressure is determined from measurements of the density of the fluid, the height of the fluid, and the acceleration of the column. A section of the taller column is filled with steel balls to control the damping of the fluid to extend its useful frequency range.

Schutte, P. C.↗

Pressure Fluctuations In Simulated Turbulent Channel Flow

Report presents study of structures of fluctuations in pressure in numerically simulated incompressible, turbulent channel flow. Based on statistical analyses of pressure and velocity fields, part of continuing effort to understand relationships among pressures, velocities, vorticities, kinetic energies, and other features of turbulent flows in vicinities of walls.

Kim, John↗