Elastic Green’s Function in Anisotropic Bimaterials Considering Interfacial Elasticity

Here, the two-dimensional elastic Green’s function is calculated for a general anisotropic elastic bimaterial containing a line dislocation and a concentrated force while accounting for the interfacial structure by means of a generalized interfacial elasticity paradigm. The introduction of the interface elasticity model gives rise to boundary conditions that are effectively equivalent to those of a weakly bounded interface. The equations of elastic equilibrium are solved by complex variable techniques and the method of analytical continuation. The solution is decomposed into the sum of the Green’s function corresponding to the perfectly bonded interface and a perturbation term corresponding to the complex coupling nature between the interface structure and a line dislocation/concentrated force. Such construct can be implemented into the boundary integral equations and the boundary element method for analysis of nano-layered structures and epitaxial systems where the interface structure plays an important role.

36 MATERIALS SCIENCE↗

SU-F-T-119: Development of Heart Prediction Model to Increase Accuracy of Dose Reconstruction for Radiotherapy Patients

Purpose: To assess individual variation in heart volume and location in order to develop a prediction model of the heart. This heart prediction model will be used to calculate individualized heart doses for radiotherapy patients in epidemiological studies. Methods: Chest CT images for 30 adult male and 30 adult female patients were obtained from NIH Clinical Center. Image-analysis computer programs were used to segment the whole heart and 8 sub-regions and to measure the volume of each sub- region and the dimension of the whole heart. An analytical dosimetry method was used for the 30 adult female patients to estimate mean heart dose during conventional left breast radiotherapy. Results: The average volumes of the whole heart were 803.37 cm{sup 3} (COV 18.8%) and 570.19 cm{sup 3} (COV 18.8%) for adult male and female patients, respectively, which are comparable with the international reference volumes of 807.69 cm{sup 3} for males and 596.15 cm{sup 3} for females. Some patient characteristics were strongly correlated (R{sup 2}>0.5) with heart volume and heart dimensions (e.g., Body Mass Index vs. heart depth in males: R{sup 2}=0.54; weight vs. heart width in the adult females: R{sup 2}=0.63). We found that the mean heart dose 3.805 Gy (assuming prescribed dose of 50 Gy) in the breast radiotherapy simulations of the 30 adult females could be an underestimate (up to 1.6-fold) or overestimate (up to 1.8-fold) of the patient-specific heart dose. Conclusion: The study showed the significant variation in patient heart volumes and dimensions, resulting in substantial dose errors when a single average heart model is used for retrospective dose reconstruction. We are completing a multivariate analysis to develop a prediction model of the heart. This model will increase accuracy in dose reconstruction for radiotherapy patients and allow us to individualize heart dose calculations for patients whose CT images are not available.

60 APPLIED LIFE SCIENCES↗

Impact of Increased Latent Generations on Sensitivity Calculations with SCALE [Slides]

Depending on the system, energy, and/or nuclide, altering the number of latent generations can significantly impact generated sensitivity coefficients. In general, as the number of latent generations increases, the accuracy of the generated sensitivity value compared with the DP value increases and there is a significant increase in the uncertainty with generated sensitivity values. IFP generated sensitivities appear to be more stable than those with CLUTCH. Complex systems, even with IFP and increased latent generations can still produce poor results (i.e., MPC- 32). This reiterates the importance of performing DPs to confirm sensitivities. IFP-Shift and CLUTCH can take advantage of parallel computing abilities. Work continues in this area as additional parameters and calculational methods are examined to provide analysts insights to successfully generating sensitivity coefficients for confirmatory analyses and validation efforts.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Method for Detection of Trace Metal and Metalloid Contaminants in Coal-Generated Fuel Gas Using Gas Chromatography/Ion Trap Mass Spectrometry

There exists an increasing need to develop a reliable method to detect trace contaminants in fuel gas derived from coal gasification. While Hg is subject to current and future regulations, As, Se, and P emissions may eventually be regulated. Sorbents are the most promising technology for the removal of contaminants from coal-derived fuel gas, and it will be important to develop a rapid analytical detection method to ensure complete removal and determine the ideal time for sorbent replacement/regeneration in order to reduce costs. This technical note explores the use of a commercial gas chromatography/ion trap mass spectrometry system for the detection of four gaseous trace contaminants in a simulated fuel gas. Quantitative, repeatable detection with limits at ppbv to ppmv levels were obtained for arsine (AsH 3 ), phosphine (PH 3 ), and hydrogen selenide (H 2 Se), while qualitative detection was observed for mercury. Decreased accuracy and response caused by the primary components of fuel gas were observed.

01 COAL, LIGNITE, AND PEAT↗

Surface scanning through a cylindrical tank of coupling fluid for clinical microwave breast imaging exams

Purpose: Microwave tomographic image quality can be improved significantly with prior knowledge of the breast surface geometry. The authors have developed a novel laser scanning system capable of accurately recovering surface renderings of breast-shaped phantoms immersed within a cylindrical tank of coupling fluid which resides completely external to the tank (and the aqueous environment) and overcomes the challenges associated with the optical distortions caused by refraction from the air, tank wall, and liquid bath interfaces. Methods: The scanner utilizes two laser line generators and a small CCD camera mounted concentrically on a rotating gantry about the microwave imaging tank. Various calibration methods were considered for optimizing the accuracy of the scanner in the presence of the optical distortions including traditional ray tracing and image registration approaches. In this paper, the authors describe the construction and operation of the laser scanner, compare the efficacy of several calibration methods-including analytical ray tracing and piecewise linear, polynomial, locally weighted mean, and thin-plate-spline (TPS) image registrations-and report outcomes from preliminary phantom experiments. Results: The results show that errors in calibrating camera angles and position prevented analytical ray tracing from achieving submillimeter accuracy in the surface renderings obtained from our scanner configuration. Conversely, calibration by image registration reliably attained mean surface errors of less than 0.5 mm depending on the geometric complexity of the object scanned. While each of the image registration approaches outperformed the ray tracing strategy, the authors found global polynomial methods produced the best compromise between average surface error and scanner robustness. Conclusions: The laser scanning system provides a fast and accurate method of three dimensional surface capture in the aqueous environment commonly found in microwave breast imaging. Optical distortions imposed by the imaging tank and coupling bath diminished the effectiveness of the ray tracing approach; however, calibration through image registration techniques reliably produced scans of submillimeter accuracy. Tests of the system with breast-shaped phantoms demonstrated the successful implementation of the scanner for the intended application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of Increased Monte Carlo Parameters on Sensitivity Calculations with SCALE [Slides]

For both models and tests, NPG and NSK parameters have only small effects on calculated sensitivity coefficients. Outside of NPG=100, only differences in CFP affected sensitivity coefficient values. Fission reactions ( 235 U) require more NPG values than scattering ( 238 U) reactions – more particles are needed to locate fission sources in the model more accurately. This work confirms the previous results with the IFP method where the CFP parameter has the greatest impact on calculated sensitivity coefficients. While immediate work focuses on fast systems, other model specifications may require a different set of MC parameters.

97 MATHEMATICS AND COMPUTING↗

Influence of inhomogeneous stochasticity on the falsifiability of mean-field theories and examples from accretion disc modelling

ABSTRACT Despite spatial and temporal fluctuations in turbulent astrophysical systems, mean-field theories can be used to describe their secular evolution. However, observations taken over time scales much shorter than dynamical time scales capture a system in a single state of its turbulence ensemble. Comparing with mean-field theory can falsify the latter only if the theory is additionally supplied with a quantified precision. The central limit theorem provides appropriate estimates to the precision only when fluctuations contribute linearly to an observable and with constant coherent scales. Here, we introduce an error propagation formula that relaxes both limitations, allowing for non-linear functional forms of observables and inhomogeneous coherent scales and amplitudes of fluctuations. The method is exemplified in the context of accretion disc theories, where inhomogeneous fluctuations in the surface temperature are propagated to the disc emission spectrum – the latter being a non-linear and non-local function of the former. The derived precision depends non-monotonically on emission frequency. Using the same method, we investigate how binned spectral fluctuations in telescope data change with the spectral resolving power. We discuss the broader implications for falsifiability of a mean-field theory.

79 ASTRONOMY AND ASTROPHYSICS↗

Engineering Prediction of Axial Wellbore Shear Failure Caused by Reservoir Uplift and Subsidence

Injection and production can cause significant regional uplift or settlement. We analytically evaluate the potential for cement-annulus failure in response to injection-induced deformation in a coupled casing/cement/rock poromechanical vertical-well system. Deformation is calculated with respect to the initial near-wellbore stress state, occurring immediately after cement curing. Tensile-failure and shear-failure lengths along this well are predicted using a stress-development-length method. The analytical model is verified by Abaqus modeling. Lastly, a sensitivity analysis identifies critical engineering-well-design parameters for ensuring wellbore-annulus integrity.

58 GEOSCIENCES↗

Applicability of the Sum-of-Fractions for Moderated Systems [Slides]

This presentation is for addressing the presence of multiple fissionable nuclides in a moderated system and validation with benchmarking gaps. The presentation finds: no instances of the use of the Sum-of-Fractions (SoF) method resulted in k eff values exceeding the calculational margin, when utilizing the SoF include all fissile nuclides, provides additional flexibility than 8.15 for mixtures, extend area of applicability by extending validation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analysis of SCALE Criticality and Sensitivity Calculations for Reflected HEU Cylinders [Abstract]

The SCALE code package offers several nuclear data libraries to support Monte Carlo (MC) transport, as well as MC-based derivation of $\kappa$ eff sensitivity and uncertainty (S/U) data. The CSAS sequence using the KENO MC code can utilize continuous-energy (CE) cross sections, or pre-generated multigroup (MG) cross section libraries. The use of MG libraries introduces bias into calculations in exchange for faster transport solutions. The TSUNAMI-3D sequence also utilizes KENO MC calculations. TSUNAMI-3D has two CE calculational methods: the Iterated Fission Probability (IFP) method, and the Contribution-Linked eigenvalue sensitivity/Uncertainty estimation via Tracklength importance CHaracterization (CLUTCH) method. Previous work has shown poor agreement between CLUTCH and confirmatory direct perturbation calculations in specific applications, e.g., fissionable and polyethylene reflectors

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Machine learning for improved current-density reconstruction from two-dimensional vector magnetic images

The reconstruction of electrical current densities from magnetic field measurements is an important technique with applications in materials science, circuit design, quality control, plasma physics, and biology. Analytic reconstruction methods exist for planar currents, but break down in the presence of high-spatial-frequency noise or large standoff distance, restricting the types of systems that can be studied. Here, we demonstrate the use of a deep convolutional neural network for current density reconstruction from two-dimensional images of vector magnetic fields acquired by a quantum diamond microscope . Trained network performance significantly exceeds analytic reconstruction for data with high noise or large standoff distances. This machine learning technique can perform quality inversions on lower-signal-to-noise-ratio data, significantly reducing the data collection time and permitting reconstructions of weaker and three-dimensional current sources. Published by the American Physical Society 2025

Reed, Niko R. (ORCID:0009000305222403)↗

Reduced scaling formulation of CASPT2 analytical gradients using the supporting subspace method

We present a reduced scaling and exact reformulation of state specific complete active space second-order perturbation (CASPT2) analytical gradients in terms of the MP2 and Fock derivatives using the supporting subspace method. This work follows naturally from the supporting subspace formulation of the CASPT2 energy in terms of the MP2 energy using dressed orbitals and Fock builds. For a given active space configuration, the terms corresponding to the MP2-gradient can be evaluated with O(N5) operations, while the rest of the calculations can be computed with O(N3) operations using Fock builds, Fock gradients, and linear algebra. When tensor-hyper-contraction is applied simultaneously, the computational cost can be further reduced to O(N4) for a fixed active space size. The new formulation enables efficient implementation of CASPT2 analytical gradients by leveraging the existing graphical processing unit (GPU)-based MP2 and Fock routines. We present benchmark results that demonstrate the accuracy and performance of the new method. Example applications of the new method in ab initio molecular dynamics simulation and constrained geometry optimization are given.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Crack opening calculation in phase-field modeling of fluid-filled fracture: A robust and efficient strain-based method

The phase-field method has become popular for the numerical modeling of fluid-filled fractures, thanks to its ability to represent complex fracture geometry without algorithms. However, the algorithm-free representation of fracture geometry poses a significant challenge in calculating the crack opening (aperture) of phase-field fracture, which governs the fracture permeability and hence the overall hydromechanical behavior. Although several approaches have been devised to compute the crack opening of phase-field fracture, they require a sophisticated algorithm for post-processing the phase-field values or an additional parameter sensitive to the element size and alignment. Here, we develop a novel method for calculating the crack opening of fluid-filled phase-field fracture, which enables one to obtain the crack opening without additional algorithms or parameters. Here we transform the displacement-jump-based kinematics of a fracture into a continuous strain-based version, insert it into a force balance equation on the fracture, and apply the phase-field approximation. Through this procedure, we obtain a simple equation for the crack opening which can be calculated with quantities at individual material points. We verify the proposed method with analytical and numerical solutions obtained based on discrete representations of fractures, demonstrating its capability to calculate the crack opening regardless of the element size or alignment.

58 GEOSCIENCES↗

Analysis of SCALE Criticality and Sensitivity Calculations for Reflected HEU Cylinders [Slides]

The SCALE code package offers multiple nuclear data libraries supporting Monte Carlo transport, with sensitivity and uncertainty methods derived from MC transport solutions. Several libraries are multigroup, which introduce bias differing by system. Previous work has shown poor S/U results in several reflector materials: ICSBEP benchmark HMF-084 was selected to analyze biases and S/U method applicability to a variety of reflectors. Prior and ongoing work found inaccuracies in CSAS and TSUNAMI results, which were further investigated utilizing the HEU-MET-FAST-084 ICSBEP critical benchmark, chosen for its geometrical simplicity and variety of reflector materials. Perturbation of reflector thickness across various reflector materials allowed for an assortment of materials is to be tested swiftly for each sequence and method. Observation was an increasing bias of MG $k_{eff}$ relative to CE, in both direction and magnitude. IFP produced extremely reliable results. >85% of CLUTCH cases were found satisfactory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of a New Fixed-source Sensitivity Tally Capability in the MCNP ® Code [Slides]

Current work includes FSEN capability development, continued verification of adjoint-weighted sensitivity method, and improvement of algorithm speed and parallelism capability. Future work is forecasted to include extensions to non-Boltzmann responses, adding more responses and particle types, and connection to new MCNP6.3 tally backend.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fast model-based scenario optimization in NSTX-U enabled by analytic gradient computation

Model-based optimization offers a systematic approach to advanced scenario planning. In this case, the feedforward-control inputs (actuator trajectories) that are needed to attain and sustain a desired scenario are obtained by solving a nonlinear constrained optimization problem. This class of problems generally minimize a cost function that measures the difference between desired and actual plasma states. Several numerical optimization algorithms, such as sequential quadratic programming, require repeated calculation of the cost function gradients with respect to the input trajectories. Calculating these gradients numerically can be computationally intensive, increasing the time needed to solve the feedforward-control optimization problem. Here, this work introduces a method to analytically calculate these cost function gradients from the current profile evolution model. This can significantly reduce the computational time and allow for fast feedforward-control optimization, which would eventually enable optimal scenario planning between discharges. The performance of the feedforward optimizer with analytical gradients is compared to a traditional optimization algorithm based on numerical gradients for different NSTX-U scenarios. The plasma dynamics in the optimization algorithm are simulated using the Control Oriented Transport SIMulator (COTSIM). Results of the work show that analytical gradients consistently reduce the computation time while achieving trajectories that are comparable to those obtained by traditional optimization algorithms based on numerical gradients.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

VADER: A Tool for Criticality Safety Validation

The purpose of criticality safety is to prevent any inadvertent criticality from occurring during the handling or storage of fissile material. Calculations are frequently used to demonstrate that a sufficient subcritical margin exists. Validation is a key aspect of the evaluation process, establishing the suitability, accuracy, and associated uncertainty of the computational method and data to be used for the intended application. The validation process is performed by comparing the results of critical experiments with the calculated results from models of the experiments using the computational method to be validated. Laboratory critical experiments are controlled systems that achieve a k eff of approximately 1 in order to investigate the parameters at which such a critical condition is achieved. The validation parameters that are traditionally applied to safety analysis calculations are the bias and the bias uncertainty . The bias is the deviation of the average k eff of the validation suite from unity. The bias uncertainty accounts for the statistical uncertainty in the bias based on the standard deviation, sample size, and distribution of k eff values of the validation suite. The values of bias and bias uncertainty ensure that the systems predicted to be subcritical by the computational method will indeed be subcritical. The bias and bias uncertainty are often combined to determine an upper subcritical limit (USL) or computational margin that can then be applied to safety analysis calculations. Many methods have been developed by different organizations to calculate the bias and bias uncertainty for various types of criticality analyses. Each of these methods typically requires that the validity of various underpinning statistical assumptions be confirmed to demonstrate that the method is appropriate for the analysis of a given validation suite. An example of the validation decision making flow is shown in Fig.1. As shown in Fig. 1, the analyst performing the validation fits a trend line to the data and performs a test to determine if the trend was a statistically better representation of the data than if it were treated as an uncorrelated sample. If the trend line is a better representation of the data, then the analyst uses any one of a number of trending techniques to determine the bias and bias uncertainty. If a trend is not an appropriate representation of the data, then the analyst proceeds to perform a normality assessment for the data. If the normal assumption can be shown to be acceptable, then the analyst calculates the bias and bias uncertainty with the parametric technique. If the assumption of normality cannot be justified, then the nonparametric technique is used. Once the decision flow has been followed and the appropriate technique has been selected, the bias and bias uncertainty is typically combined with an administrative margin to determine a USL below which calculated values of k eff for safety analysis models can be considered subcritical. The calculations used in each decision are often performed with spreadsheets or with small programs available at various sites performing criticality analyses. Expertise in understanding and interpreting the results must be maintained to perform these calculations. This can often be an error-prone process. Oak Ridge National Laboratory (ORNL) is currently developing the Validation and Data Evaluation Resource (VADER) to simplify and automate the criticality safety validation process and to provide a software quality assurance pedigree to the calculational methods used. This paper discusses the use of the Fulcrum user interface with VADER, the anticipated initial capabilities of VADER to perform validation analyses, and the output from the code.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Millisecond-long suppression of spectroscopic optical signals using laser filamentation

Ultrashort laser pulse filamentation in air can extend the delivery of focused laser energy to distances greatly exceeding the Rayleigh length. In this way, remote measurements can be conducted using many standard methods of analytical spectroscopy. The performance of spectroscopic techniques can be enhanced by temporal gating, which rejects the unwanted noise and background. In the present work, we investigate the thermal relaxation of air in the wake of single-filament plasmas using shadowgraphy. Here, we demonstrate that the transient change in refractive index associated with relaxation of the gas can be used to reject both continuous and time-varying spectroscopic signals, including emission from laser-produced plasmas. This method can augment temporal gating of simple optical detectors.

47 OTHER INSTRUMENTATION↗