Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AIR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

LIQUID AIR INTERFACE CORROSION TESTING FOR FY2010

An experimental study was undertaken to investigate the corrosivity to carbon steel of the liquid-air interface of dilute simulated radioactive waste solutions. Open-circuit potentials were measured on ASTM A537 carbon steel specimens located slightly above, at, and below the liquid-air interface of simulated waste solutions. The 0.12-inch-diameter specimens used in the study were sized to respond to the assumed distinctive chemical environment of the liquid-air interface, where localized corrosion in poorly inhibited solutions may frequently be observed. The practical inhibition of such localized corrosion in liquid radioactive waste storage tanks is based on empirical testing and a model of a liquid-air interface environment that is made more corrosive than the underlying bulk liquid due to chemical changes brought about by absorbed atmospheric carbon dioxide. The chemical changes were assumed to create a more corrosive open-circuit potential in carbon in contact with the liquid-air interface. Arrays of 4 small specimens spaced about 0.3 in. apart were partially immersed so that one specimen contacted the top of the meniscus of the test solution. Two specimens contacted the bulk liquid below the meniscus and one specimen was positioned in the vapor space above the meniscus. Measurements were carried out for up to 16 hours to ensure steady-state had been obtained. The results showed that there was no significant difference in open-circuit potentials between the meniscus-contact specimens and the bulk-liquid-contact specimens. With the measurement technique employed, no difference was detected between the electrochemical conditions of the meniscus versus the bulk liquid. Stable open-circuit potentials were measured on the specimen located in the vapor space above the meniscus, showing that there existed an electrochemical connection through a thin film of solution extending up from the meniscus. This observation supports the Hobbs-Wallace model of the development of the pitting susceptibility of carbon steel in alkaline solutions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Air Monitoring of Emissions from the Fukushima Daiichi Reactor

In response to the disasters in Japan on March 11, 2011, and the subsequent emissions from Fukushima-Daiichi, we monitored the air near Los Alamos using four air-monitoring systems: the standard AIRNET samplers, the standard rad-NESHAP samplers, the NEWNET system, and high-volume air samplers. Each of these systems has advantages and disadvantages. In combination, they provide a comprehensive set of measurements of airborne radionuclides near Los Alamos during the weeks following March 11. We report air-monitoring measurements of the fission products released from the Fukushima-Daiichi nuclear-power-plant accident in 2011. Clear gamma-spectrometry peaks were observed from Cs-134, Cs-136, Cs-137, I-131, I132, Te-132, and Te-129m. These data, together with measurements of other radionuclides, are adequate for an assessment and assure us that radionuclides from Fukushima Daiichi did not present a threat to human health at or near Los Alamos. The data demonstrate the capabilities of the Los Alamos air-monitoring systems.

54 ENVIRONMENTAL SCIENCES↗

Low-Flow Liquid Desiccant Air-Conditioning: Demonstrated Performance and Cost Implications

Cooling loads must be dramatically reduced when designing net-zero energy buildings or other highly efficient facilities. Advances in this area have focused primarily on reducing a building's sensible cooling loads by improving the envelope, integrating properly sized daylighting systems, adding exterior solar shading devices, and reducing internal heat gains. As sensible loads decrease, however, latent loads remain relatively constant, and thus become a greater fraction of the overall cooling requirement in highly efficient building designs, particularly in humid climates. This shift toward latent cooling is a challenge for heating, ventilation, and air-conditioning (HVAC) systems. Traditional systems typically dehumidify by first overcooling air below the dew-point temperature and then reheating it to an appropriate supply temperature, which requires an excessive amount of energy. Another dehumidification strategy incorporates solid desiccant rotors that remove water from air more efficiently; however, these systems are large and increase fan energy consumption due to the increased airside pressure drop of solid desiccant rotors. A third dehumidification strategy involves high flow liquid desiccant systems. These systems require a high maintenance separator to protect the air distribution system from corrosive desiccant droplet carryover and so are more commonly used in industrial applications and rarely in commercial buildings. Both solid desiccant systems and most high-flow liquid desiccant systems (if not internally cooled) add sensible energy which must later be removed to the air stream during dehumidification, through the release of sensible heat during the sorption process.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Distribution and Room Air Mixing Risks to Retrofitted Homes

An energy efficiency upgrade reduces a home’s heating and cooling load. If the load reduction is great enough and the heating, ventilation, and air conditioning system warrants replacement, that system is often upgraded with a more efficient, lower capacity system that meets the load of the upgraded house. For a single-story house with floor supply air diffusers, the ducts often are removed and upgraded. For houses with ducts that are embedded in walls, the cost of demolition precludes the replacement of ducts. The challenge with the use of existing ducts is that the reduced airflow creates a decreased throw at the supply registers, and the supply air and room air do not mix well, leading to potential thermal comfort complaints. This project investigates this retrofit scenario. The issues and solutions discussed here are relevant to all climate zones, with emphasis on climates that require cooling. In this project, IBACOS performed load calculations for a two-story 1960s house and characterized duct sizes and layouts based on industry “rules of thumb” (Herk et al. 2014). The team performed duct-sizing calculations for unaltered ducts and post-retrofit airflows and examined airflow velocities and pressure changes with respect to various factors. The team then used a mocked-up duct and register setup to measure the characteristics of isothermal air—to reduce the effects of buoyancy from the observations—passing through the duct and leaving the register.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Laboratory Evaluation of Air Flow Measurement Methods for Residential HVAC Returns for New Instrument Standards

This project improved the accuracy of air flow measurements used in commissioning California heating and air conditioning systems in Title 24 (Building and Appliance Efficiency Standards), thereby improving system performance and efficiency of California residences. The research team at Lawrence Berkeley National Laboratory addressed the issue that typical tools used by contractors in the field to test air flows may not be accurate enough to measure return flows used in Title 24 applications. The team developed guidance on performance of current diagnostics as well as a draft test method for use in future evaluations. The study team prepared a draft test method through ASTM International to determine the uncertainty of air flow measurements at residential heating ventilation and air conditioning returns and other terminals. This test method, when finalized, can be used by the Energy Commission and other entities to specify required accuracy of measurement devices used to show compliance with standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improving AHU Performance by Minimizing Approach Temperature, Reducing Air Maldistribution, and Efficiently Handling Sensible and Latent Loads (Phase 1 Interim Final Technical Report)

Residential air handling units (AHUs) have stayed the same in form and efficiency for the past 30+ years, with incremental improvements made to address safety, functionality, and energy-efficiency. The purpose of this research in Phase I, Topic 9a: Next Generation Residential Air Handlers, was to improve AHU performance by minimizing heat exchanger (HX) approach temperature, reducing air maldistribution, and developing alternative system configurations which more efficiently handle sensible and latent loads. In this research Optimized Thermal Systems (OTS) developed, modeled, and evaluated multiple alternative system concepts. A dual vapor compression system separate sensible and latent cooling (SSLC) concept was studied to inform work on alternative concepts and to show best-case performance benefit. System concepts included ejector enhanced vapor compression cycles, desiccant assisted dehumidification, dual evaporator SSLC, and alternative AHU HX configurations. A dual vapor compression system showed COP improvement of 20%, however, required additional components, increased unit size, and increased cost. Two types of ejector enhanced vapor compression cycles with dual evaporators improved system COP by 9 to 11%, and reduced AHU losses by as much as 18%, with design changes limited to the AHU, no unit physical size increase, and a moderate increase to system first cost. Desiccant assisted air-conditioning required increased air flow rate resulting in higher fan power and the desiccant wheel increased sensible heat load leading to increased compressor power and reduced system COP. Dual evaporator cycles were found to degrade performance due to increased expansion losses. Optimized single slab HX designs used in place of the traditional A-coil HX led to 44–49% reduction in aluminum, 47–60% less refrigerant charge, and improved HX velocity distribution.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Savings With Acceptable Indoor Air Quality Through Improved Airflow Control in Residential Retrofits

The Partnership for Advanced Residential Retrofit (PARR) has been a U.S. Department of Energy (DOE) Building America team since 2009, with a primary focus on upgrading the performance of existing buildings to reduce energy loads. In this project, PARR’s work explored the integration of airflow-focused measures in residential retrofit homes with the goal to maximize energy savings while ensuring acceptable indoor air quality (IAQ) using a systems approach to controlling four contributing air streams: • Building air leakage (natural, uncontrolled infiltration), • Forced-air distribution system static pressure and airflow rate, • Distribution system duct leakage, and • Mechanical ventilation. This project addressed airflows in houses, their combined impact on energy use and IAQ, and the comparative effects of typical insulation and air sealing practices versus integrated system-level retrofits. Additionally, practical considerations for contractors taking either approach were addressed. Finally, the effects of supply ventilation and exhaust ventilation on IAQ were compared in occupied homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2022 LANL Radionuclide Air Emissions Report (Rev. 2)

This report describes the emissions of airborne radionuclides from operations at Los Alamos National Laboratory (LANL) for calendar year 2022 and the resulting off-site dose from these emissions. This document fulfills the requirements established by the National Emissions Standards for Hazardous Air Pollutants in 40 CFR 61, Subpart H – Emissions of Radionuclides other than Radon from Department of Energy Facilities, commonly referred to as the Radionuclide NESHAP or Rad-NESHAP. Compliance with this regulation and preparation of this document is the responsibility of LANL’s Rad NESHAP compliance program, which is part of the Environmental Protection and Compliance (EPC) Division. The information in this report is required under the Clean Air Act and is being submitted to the U.S. Environmental Protection Agency (EPA) Headquarters and EPA Region 6. The highest effective dose equivalent (EDE) to an off-site member of the public was calculated using procedures specified by the EPA and described in this report. LANL’s EDE was 0.45 for 2022. The annual limit is 10 millirem per year, established by the EPA in 40 CFR 61 Subpart H. All measured air emissions are modeled to a single location, known as the Maximally Exposed Individual (MEI). During calendar year 2022, LANL continuously monitored radionuclide emissions at 27 “major” release points, or stacks. The Laboratory estimates emissions from an additional 34 “minor” release points using radionuclide usage source terms in lieu of stack monitoring. Also, LANL uses an EPA approved network of air samplers around the Laboratory perimeter to monitor ambient airborne levels of radionuclides. To provide data for dispersion modeling and dose assessment, LANL maintains and operates several meteorological monitoring towers. From these various systems, a comprehensive evaluation is conducted to calculate the MEI dose for the Laboratory. The MEI can be any member of the public at any off-site location where there is a residence, school, business, or office. In 2022, this MEI location was a business at 95 Entrada Drive, located in the eastern end of Los Alamos town site. The primary contributors to the off-site dose at this location are the ambient air data at that location combined with radioactive gas emissions from the LANSCE facility and the collected potential emissions from unmonitored (minor) sources. Overall, the MEI dose in 2022 is similar to that which has been observed in recent years, and it remains well below the EPA’s 10 millirem per year limit. Doses reported to the EPA for the past 10 years are shown in Table E1.

54 ENVIRONMENTAL SCIENCES↗

Data Quality Objectives Supporting Radiological Air Emissions Monitoring for the PNNL-Richland Campus: North Campus Construction (Rev. 3)

Starting in fiscal year 2023, the north area of the PNNL-Richland Campus will undergo development. Initially, infrastructure (water, electrical) improvements will be installed. Later development includes the construction of several new office buildings. The area to be developed currently contains no buildings but does have two existing solar-powered ambient air sampling stations. Under the requirements of Washington State Department of Health Radioactive Air Emissions License -005, the PNNL-Richland Campus must operate and maintain a radiological air monitoring program. This revision documents and evaluates how the new North Campus construction impacts ambient air surveillance stations within the development region. This revision also considers current stack configurations and uses an updated environmental dispersion model and updated meteorological data. The DQO team concluded that one sampling station in the construction area will be relocated and the other remain in place. The evaluations conducted for this DQO also identified a third sampling station outside the development area that is recommended for relocation as a result of updated dispersion modeling. Recommended sites for the relocations are presented. Considerations for sampling in and around a construction zone are also addressed. Additionally, programmatic improvements to the ambient air sampling program were identified in the DQO process.

54 ENVIRONMENTAL SCIENCES↗

Notice of Submittal – 2023 Radionuclide Air Emissions Report for Los Alamos National Laboratory

This report describes the emissions of airborne radionuclides from operations at Los Alamos National Laboratory (LANL) for calendar year 2023 and the resulting off-site dose from these emissions. This document fulfills the requirements established by the National Emissions Standards for Hazardous Air Pollutants in 40 CFR 61, Subpart H – Emissions of Radionuclides other than Radon from Department of Energy Facilities, commonly referred to as the Radionuclide NESHAP or Rad-NESHAP. Compliance with this regulation and preparation of this document is the responsibility of LANL’s Rad NESHAP compliance program, which is part of the Environmental Protection and Compliance (EPC) Division. The information in this report is required under the Clean Air Act and is being submitted to the U.S. Environmental Protection Agency (EPA) Headquarters and EPA Region 6. The highest effective dose equivalent (EDE) to an off-site member of the public was calculated using procedures specified by the EPA and described in this report. LANL’s EDE was 0.43 for 2023. The annual limit is 10 millirem per year, established by the EPA in 40 CFR 61 Subpart H. All measured air emissions are modeled to a single location, known as the Maximally Exposed Individual (MEI). During calendar year 2023, LANL continuously monitored radionuclide emissions at 28 “major” release points, or stacks. The Laboratory estimates emissions from an additional 59 “minor” release points using radionuclide usage source terms in lieu of stack monitoring. Also, LANL uses an EPA approved network of air samplers around the Laboratory perimeter to monitor ambient airborne levels of radionuclides. To provide data for dispersion modeling and dose assessment, LANL maintains and operates several meteorological monitoring towers. From these various systems, a comprehensive evaluation is conducted to calculate the MEI dose for the Laboratory. The MEI can be any member of the public at any off-site location where there is a residence, school, business, or office. In 2023, this MEI location was a business at 129 New Mexico State Road 4 (NM-4), located in the northern end of White Rock. The primary contributors to the off-site dose at this location are the ambient air data at that location combined with the collected potential emissions from unmonitored (minor) sources. Overall, the MEI dose in 2023 is similar to that which has been observed in recent years, and it remains well below the EPA’s 10 millirem per year limit. Doses reported to the EPA for the past 10 years are shown in Table E1.

54 ENVIRONMENTAL SCIENCES↗

A Combined Water and CO 2 Direct Air Capture System (Final Technical Report)

The primary objective of the project was to demonstrate the technical and economic performance of a technology that simultaneously captures CO 2 and water from the air – a Hybrid Direct Air Capture system (HDAC). In HDAC, air is passed over water capture section as well as a CO 2 selective sorbent to remove CO 2 from the air stream. Combining potable water generation and CO 2 capture in a single device with the unique energy conserving features of the proposed design enables long-term projected CAPEX under $\$$750/t-CO 2 and levelized cost of capture (LCOC) of $\$$140/t-CO 2 . Project DE-FE-0031970 "A Combined Water and CO 2 Direct Air Capture System" ran for four years and three months from 10/01/2020 to 12/31/2024 for three budget periods and an extension period. The total project budget at completion was $\$$3,534,408 consisting of a $\$$2,680,064 federal share and $\$$854,344 cost share. The pilot plant was successfully designed, engineered, built and commissioned during the initial three budget periods. The plant demonstrated successful water capture during this period, whereas initial CO 2 capture was well below target values. The project team requested an extension period during which alternate materials and beds were evaluated. By the end of the project, both moisture swing adsorption of CO 2 and water capture had successfully been demonstrated at target capture rates making further scale-up of the technology viable.

42 ENGINEERING↗

Experiment investigations on the performance of a centrally fuel rich swirl coal combustion burner: Influence of primary air ratio - article no. A39

A three-component particle-dynamics anemometer is used to measure, in the near-burner region, the influence of the primary air ratio on the gas/particle two phase characteristics for a centrally fuel rich swirl coal combustion burner, on a gas/particle two phase test facility. Velocities, particle volume flux profiles and particle relative number concentrations were obtained. With a low primary air ratio, the axial velocities for gas and particles on the chamber axis are always small and easily reach the negative, and the central recirculation zone is easily formed and much closer to the outlet of the burner. In each cross-section, in the radius range from R<d=0 to 0.11, the particle volume flux with r{sub 1}=23.85% is always larger than that with r{sub 1}=16.56%, which means the degree penetration with a high primary air ratio is higher than that with a low primary air ratio. The influence of gas/particle flow characteristics with a different primary air ratio on combustion has been analyzed.

01 COAL, LIGNITE, AND PEAT↗

Techno-Economic Analysis and Optimization of a Compressed-Air Energy Storage System Integrated with a Natural Gas Combined-Cycle Plant

To address the rising electricity demand and greenhouse gas concentration in the environment, considerable effort is being carried out across the globe on installing and operating renewable energy sources. However, the renewable energy production is affected by diurnal and seasonal variability. To ensure that the electric grid remains reliable and resilient even for the high penetration of renewables into the grid, various types of energy storage systems are being investigated. In this paper, a compressed-air energy storage (CAES) system integrated with a natural gas combined-cycle (NGCC) power plant is investigated where air is extracted from the gas turbine compressor or injected back into the gas turbine combustor when it is optimal to do so. First-principles dynamic models of the NGCC plant and CAES are developed along with the development of an economic model. The dynamic optimization of the integrated system is undertaken in the Python/Pyomo platform for maximizing the net present value (NPV). NPV optimization is undertaken for 14 regions/cases considering year-long locational marginal price (LMP) data with a 1 h interval. Design variables such as the storage capacity and storage pressure, as well as the operating variables such as the power plant load, air injection rate, and air extraction rate, are optimized. Results show that the integrated CAES system has a higher NPV than the NGCC-only system for all 14 regions, thus indicating the potential deployment of the integrated system under the assumption of the availability of caverns in close proximity to the NGCC plant. The levelized cost of storage is found to be in the range of 136–145 $/MWh. Roundtrip efficiency is found to be between 74.6–82.5%. A sensitivity study with respect to LMP shows that the LMP profile has a significant impact on the extent of air injection/extraction while capital expenditure reduction has a negligible effect.

25 ENERGY STORAGE↗

An Unobstructive Sensing Method for Indoor Air Quality Optimization and Metabolic Assessment within Vehicles

This work investigates the use of an intelligent and unobstructive sensing technique for maintaining vehicle cabin’s indoor air quality while simultaneously assessing the driver metabolic rate. CO 2 accumulation patterns are of great interest because CO 2 can have negative cognitive effects at higher concentrations and also since CO 2 accumulation rate can potentially be used to determine a person’s metabolic rate. The management of the vehicle’s ventilation system was controlled by periodically alternating the air recirculation mode within the cabin, which was actuated based on the CO 2 levels inside the vehicle’s cabin. The CO 2 accumulation periods were used to assess the driver’s metabolic rate, using a model that considered the vehicle’s air exchange rate. In the process of the method optimization, it was found that the vehicle’s air exchange rate (λ [h –1 ]) depends on the vehicle speeds, following the relationship: λ = 0.060 × (speed) – 0.88 when driving faster than 17 MPH. An accuracy level of 95% was found between the new method to assess the driver’s metabolic rate (1620 ± 140 kcal/day) and the reference method of indirect calorimetry (1550 ± 150 kcal/day) for a total of N = 16 metabolic assessments at various vehicle speeds. The new sensing method represents a novel approach for unobstructive assessment of driver metabolic rate while maintaining indoor air quality within the vehicle cabin.

passive sensing↗

Energy savings potential in air conditioners and chiller systems

In the current paper we quantified and evaluated the energy saving potential in air conditioners and chiller systems. Here, we also showed how to reduce the cost of air conditioners and chiller systems in existing facilities on the basis of payback periods. Among the measures investigated were: (1) installing higher efficiency air conditioners, (2) installing higher efficiency chillers, (3) duty cycling air conditioning units, and (4) utilizing existing economizers on air conditioning units. For each method, examples were provided from Arizona, USA. In these examples, the amount of saved energy, the financial evaluation of this energy, and the investment cost and pay back periods were calculated.

54 ENVIRONMENTAL SCIENCES↗

The Measurement of Fuel-air Ratio by Analysis of the Oxidized Exhaust Gas

An investigation was made to determine a method of measuring fuel-air ratio that could be used for test purposes in flight and for checking conventional equipment in the laboratory. Two single-cylinder test engines equipped with typical commercial engine cylinders were used. The fuel-air ratio of the mixture delivered to the engines was determined by direct measurement of the quantity of air and of fuel supplied and also by analysis of the oxidized exhaust gas and of the normal exhaust gas. Five fuels were used: gasoline that complied with Army-Navy Fuel Specification, No. AN-VV-F-781 and four mixtures of this gasoline with toluene, benzene, and xylene. The method of determining the fuel-air ratio described in this report involves the measurement of the carbon-dioxide content of the oxidized exhaust gas and the use of graphs or the presented equation. This method is considered useful in aircraft, in the field, or in the laboratory for a range of fuel-air ratios from 0.047 to 0.124

FUELS-TOLUENE↗

Validation of AIRS Retrievals of CO2 via Comparison to In Situ Measurements

Topics include AIRS on Aqua, 2002-present with discussion about continued operation to 2011 and beyond and background, including spectrum, weighting functions, and initialization; comparison with aircraft and FTIR measurements in Masueda (CONTRAIL) JAL flask measurements, Park Falls, WI FTIR, Bremen, GDF, and Spitsbergen, Norway; AIRS retrievals over addition FTIR sites in Darwin, AU and Lauder, NZ; and mid-tropospheric carbon dioxide weather and contribution from major surface sources. Slide titles include typical AIRS infrared spectrum, AIRS sensitivity for retrieving CO2 profiles, independence of CO2 solution with respect to the initial guess, available in situ measurements for validation and comparison, comparison of collocated V1.5x AIRS CO2 (N_coll greater than or equal to 9) with INTEX-NA and SPURT;

AIRS↗

Gravity Wave Variances and Propagation Derived from AIRS Radiances

As the first gravity wave (GW) climatology study using nadir-viewing infrared sounders, 50 Atmospheric Infrared Sounder (AIRS) radiance channels are selected to estimate GW variances at pressure levels between 2-100 hPa. The GW variance for each scan in the cross-track direction is derived from radiance perturbations in the scan, independently of adjacent scans along the orbit. Since the scanning swaths are perpendicular to the satellite orbits, which are inclined meridionally at most latitudes, the zonal component of GW propagation can be inferred by differencing the variances derived between the westmost and the eastmost viewing angles. Consistent with previous GW studies using various satellite instruments, monthly mean AIRS variance shows large enhancements over meridionally oriented mountain ranges as well as some islands at winter hemisphere high latitudes. Enhanced wave activities are also found above tropical deep convective regions. GWs prefer to propagate westward above mountain ranges, and eastward above deep convection. AIRS 90 field-of-views (FOVs), ranging from +48 deg. to −48 deg. off nadir, can detect large-amplitude GWs with a phase velocity propagating preferentially at steep angles (e.g., those from orographic and convective sources). The annual cycle dominates the GW variances and the preferred propagation directions for all latitudes. Indication of a weak two-year variation in the tropics is found, which is presumably related to the Quasi-biennial oscillation (QBO). AIRS geometry makes its out-tracks capable of detecting GWs with vertical wavelengths substantially shorter than the thickness of instrument weighting functions. The novel discovery of AIRS capability of observing shallow inertia GWs will expand the potential of satellite GW remote sensing and provide further constraints on the GW drag parameterization schemes in the general circulation models (GCMs).

AIRS↗