Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ACOUSTIC TESTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

Intermodal transfer in temporal discrimination

This study determined if training for accuracy in temporal discrimination would transfer across sensory modalities. A fractionation method was used in which subjects bisected the durations of acoustic and visual signals at three standard intervals (6, 12, and 18 sec). Absolute error was the performance index. Half of the subjects were trained with acoustic stimuli and then tested in vision; the remainder were trained in vision and tested in audition. Similar negatively accelerated acquisition functions were noted for both modalities. Positive intermodal transfer, characterized by symmetry across modalities, was obtained at all standard durations. The results were considered to provide support for the notion that a common mechanism underlies temporal discriminations in different sensory systems.

Warm, J. S.↗

Use of coherence and phase data between two receivers in evaluation of noise environments

For certain types of noise control problems, where transducers cannot be mounted on suspected sources, valuable information can often be obtained by comparing the coherence and phase data measured between two closely spaced microphones with analytical models deduced from the physics of the problem. However, the application of such analysis techniques must be pursued with care, particularly when the measurements are made in a reverberant area. A simple illustration is presented where the acoustic field in the test section of a wind tunnel is evaluated by modelling the field as a combination of diffuse noise due to the boundary layer turbulence in the test section and propagating noise generated by the tunnel fan and possible flow disturbances outside the test section. The coherence and phase between two closely spaced microphones in the tunnel test section are predicted for various ratios of diffuse to propagating noise contributions and compared to actual measurements under several different tunnel operating conditions.

Piersol, A. G.↗

Evaluation of aero commander propeller acoustic data: Taxi operations

The acoustic data from ground tests performed on an Aero Commander propeller driven aircraft are analyzed. An array of microphones flush mounted on the side of the fuselage were used to record data. The propeller blade passage noise during operations at several different taxi speeds is considered and calculations of the magnitude and phase of the blade passage tones, the amplitude stability of the tones, and the spatial phase and coherence of the tones are included. The measured results are compared to theoretical predictions for propeller noise and various evaluations which reveal important details of propeller noise characteristics are presented.

Piersol, A. G.↗

On the use of coherence functions to evaluate sources of dynamic excitation

The use of coherence functions for identifying the relative contributions of multiple dynamic inputs to the measured vibration response of spacecraft components on a practical, complex structure was investigated. Data were generated by applying simultaneous vibratory and acoustic excitation to a test model (a modified Titan instrumentation truss). Up to three inputs were used. In some cases mutually coherent inputs were generated. A digital computer program was written to analyze the test data, using an approach based on iterative computational algorithms. The results showed that the coherence function technique was effective in identifying and evaluating sources of excitation, for both independent and coherent inputs. The effect of varying the number of data samples used in the necessary averaging process was briefly investigated.

Barrett, S.↗

Multiwall TPS: An emerging concept

The transformation of a titanium multiwall thermal protection system from a conceptual design to a working reality is described. The thermal and structural performance of the basic multiwall concept is analyzed. Radiant heat, wind tunnel, vibration, acoustic, and lightning strike tests are used to verify the performance of multiwall tiles under representative operating conditions. Flat, all titanium multiwall configurations limited to temperature below 810 K are discussed. Curved surface, higher temperature versions of the multiwall are considered. Preliminary mass estimates for advanced multiwall concepts are presented.

Shideler, J. L.↗

Multiwall TPS - An emerging concept

Research on titanium multiwall used for thermal protection is reviewed. Continuing analytical and experimental studies yielding a fundamental understanding of the thermal and structural performance of the basic multiwall concept are presented noting that central to this understanding is a knowledge of the extensional behavior of the dimpled sheets since the thinner flat sheets will buckle and be relatively ineffective in supporting compressive loads. Results from radiant heating, aerothermal, vibration, acoustic and lightning strike tests are described as part of an effort to verify the performance of multiwall tiles under representative operating conditions. Flight tests of a large array of tiles are also planned as part of an orbiter experiments program. The research effort is being extended from flat all-titanium multiwall configurations limited to temperatures below 810 K to curved surfaces and higher temperature versions. Multi-wall concepts are found to offer the durability of metallic systems and to be mass competitive with the insulation system currently used on the Space Shuttle Orbiter.

Shideler, J. L.↗

Frequency-Discriminating Acoustic-Event Counter

Broadband events rejected. Acoustic-event counter discriminates against signals that simultaneously exceed preset amplitude thresholds in both low and high-frequency bands of its spectrum. Counter acts as spectral analyzer for mechanical vibrations. In combination with broadband acoustic transducer discriminates between signals and noise in acoustical destructive or nondestructive testing, vibration monitoring for machinery, burglar alarms, and other monitoring/warning systems.

Sugg, F. E.↗

Presentation of the acoustic and aerodynamic results of the Aladin 2 concept qualification testing

Wind tunnel tests were conducted of a scale model of the Aladin 2 aircraft. The propulsion system configuration is described and the air flow caused by jet ejection is analyzed. Three dimensional flow studies in the vicinity of the engine installation were made. Diagrams of the leading and trailing edge flaps are provided. Graphs are developed to show the aerodynamic performance under conditions of various airspeed and flap deflection.

Collard, M.↗

NORSTAR Project: Norfolk public schools student team for acoustical research

Development of the NORSTAR (Norfolk Public Student Team for Acoustical Research) Project includes the definition, design, fabrication, testing, analysis, and publishing the results of an acoustical experiment. The student-run program is based on a space flight organization similar to the Viking Project. The experiment will measure the scattering transfer of momentum from a sound field to spheres in a liquid medium. It is hoped that the experimental results will shed light on a difficult physics problem - the difference in scattering cross section (the overall effect of the sound wave scattering) for solid spheres and hollow spheres of differing wall thicknesses.

Fortunato, Ronald C.↗

Evaluation of a multi-point method for determining acoustic impedance

An investigation was conducted to explore potential improvements provided by a Multi-Point Method (MPM) over the Standing Wave Method (SWM) and Two-Microphone Method (TMM) for determining acoustic impedance. A wave propagation model was developed to model the standing wave pattern in an impedance tube. The acoustic impedance of a test specimen was calculated from a best fit of this standing wave pattern to pressure measurements obtained along the impedance tube centerline. Three measurement spacing distributions were examined: uniform, random, and selective. Calculated standing wave patterns match the point pressure measurement distributions with good agreement for a reflection factor magnitude range of 0.004 to 0.999. Comparisons of results using 2, 3, 6, and 18 measurement points showed that the most consistent results are obtained when using at least 6 evenly spaced pressure measurements per half-wavelength. Also, data were acquired with broadband noise added to the discrete frequency noise and impedances were calculated using the MPM and TMM algorithms. The results indicate that the MPM will be superior to the TMM in the presence of significant broadband noise levels associated with mean flow.

Jones, Michael G.↗

Active control of sound transmission/radiation from elastic plates by vibration inputs. II - Experiments

Actively controlled harmonic force inputs were applied experimentally to reduce the sound transmitted through an elastic circular plate. The control implementation used a time domain least mean square adaptive algorithm with two error sensors. The control forces were applied directly to the plate by point force vibration inputs, while the error information and performance were measured in the radiated acoustic field by microphones. Test cases were also performed in which the error sensors were accelerometers mounted on the plate. When accelerometers were used as error sensors, the controller performance was degraded; leading to the conclusion that minimizing plate motion does not necessarily lead to an associated decrease in radiated sound levels. In contrast, the results show excellent attenuation of the transmitted sound field when microphone error sensors were used. This result was consistent over a range of frequencies. In addition, the experimental results are compared to previously derived analytical results and the effect of using a point or global minimization scheme is discussed.

Metcalf, V. L.↗

Advanced Rotorcraft Transmission program summary

The current status of the Advanced Rotorcraft Transmission (ART) program is reviewed. The discussion includes a general configuration and face gear description, weight analysis, stress analysis, reliability analysis, acoustic analysis, face gear testing, and planned torque split testing. Design descriptions include the face gear webs sized for equal stiffness, a positive engagement clutch, the lubrication system, and a high contact ratio planetary. Test results for five gear materials and three housing materials are presented.

Bossler, Robert B., Jr.↗

Forward rotor vortex effects on counter rotating propeller noise

Three configurations of a model counter rotating propeller manipulate the blade tip flow by: placing the CRP at angle of attack, installing shrouds, and turning the upstream blades to provide forward sweep. Flow visualization and flow measurements with thermal anemometry show no evidence of a tip vortex; however, a leading edge vortex was detected on aft swept blades. The modifications served to alter the strength and/or path of the leading edge vortex. The vortical flow is eliminated by forward sweep on the upstream propeller blades. Far field acoustic data from each test indicate only small influences on the level and directivity of the BPFs. The interaction tone at the sum of the two BPF's was significantly altered in a consistent manner. As the vortex system varied, the interaction tone was affected: far field noise levels in the forward quandrant increased and the characteristic noise minimum near the plane of rotation became less pronounced and in some cases were eliminated. If the forward propeller leading edge vortex system does not impact the rear propeller in the standard manner, a net increase in the primary interaction tone occurs for the model tested. If the leading edge vortex is removed, the interaction tone increases.

Laur, Michele↗

High-temperature fiber-optic lever microphone

The design and construction of a fiber-optic lever microphone, capable of operating continuously at temperatures up to 538 C (1000 F) are described. The design is based on the theoretical sensitivities of each of the microphone system components, namely, a cartridge containing a stretched membrane, an optical fiber probe, and an optoelectronic amplifier. Laboratory calibrations include the pistonphone sensitivity and harmonic distortion at ambient temperature, and frequency response, background noise, and optical power transmission at both ambient and elevated temperatures. A field test in the Thermal Acoustic Fatigue Apparatus at Langley Research Center, in which the microphone was subjected to overall sound-pressure levels in the range of 130-160 dB and at temperatures from ambient to 538 C, revealed good agreement with a standard probe microphone.

Zuckerwar, Allan J.↗

Exploratory Environmental Tests of Several Heat Shields

Exploratory tests have been conducted with several conceptual radiative heat shields of composite construction. Measured transient temperature distributions were obtained for a graphite heat shield without insulation and with three types of insulating materials, and for a metal multipost heat shield, at surface temperatures of approximately 2,000 F and 1,450 F, respectively, by use of a radiant-heat facility. The graphite configurations suffered loss of surface material under repeated irradiation. Temperature distribution calculated for the metal heat shield by a numerical procedure was in good agreement with measured data. Environmental survival tests of the graphite heat shield without insulation, an insulated multipost heat shield, and a stainless-steel-tile heat shield were made at temperatures of 2,000 F and dynamic pressures of approximately 6,000 lb/sq ft, provided by an ethylene-heated jet operating at a Mach number of 2.0 and sea-level conditions. The graphite heat shield survived the simulated aerodynamic heating and pressure loading. A problem area exists in the design and materials for heat-resistant fasteners between the graphite shield and the base structure. The insulated multipost heat shield was found to be superior to the stainless-steel-tile heat shield in retarding heat flow. Over-lapped face-plate joints and surface smoothness of the insulated multi- post heat shield were not adversely affected by the test environment. The graphite heat shield without insulation survived tests made in the acoustic environment of a large air jet. This acoustic environment is random in frequency and has an overall noise level of 160 decibels.

Goodman, George P.↗

Broadband Transmission Loss Due to Reverberant Excitation

The noise transmission characteristics of candidate curved aircraft sidewall panel constructions is examined analytically using finite element models of the selected panel geometries. The models are validated by experimental modal analyses and transmission loss testing. The structural and acoustic response of the models are then examined when subjected to random or reverberant excitation, the simulation of which is also discussed. For a candidate curved honeycomb panel, the effect of add-on trim panel treatments is examined. Specifically, two different mounting configurations are discussed and their effect on the transmission loss of the panel is presented. This study finds that the add-on acoustical treatments do improve on the primary structures transmission loss characteristics, however, much more research is necessary to draw any valid conclusions about the optimal configuration for the maximum noise transmission loss. This paper describes several directions for the extension of this work.

Barisciano, Lawrence P. Jr.↗

Storable Propellant Combustion Instability Program at Lewis Research Center

An experimental program at Lewis Research Center investigates acoustical-mode combustion instability in liquid propellant rockets. One phase of this program is concerned with nitrogen tetroxide and a 50-50 fuel blend of hydrazine-UDMH. Effects on combustor stability and performance by variations in injection velocities, impingement angle and distance, amd thrust per element of triplet injectors were studied in a 10.77-inch- diameter cylindrical combustor at chamber pressures of 100 and 300 psia. Nominal thrust levels were 6700 and 20 000 pounds. Stability rating was accomplished by the use of various size RDX explosive charges to generate tangential pressure disturbances. The injection velocity effect correlated by using a ratio V(sub o)/V(sub f). Stability correlation with V(sub o)/V(sub f) resulted in a sharply humped curve with maximum stability at a ratio of 1.2. Performance decreased with increase in V(sub o)/V(sub f) after a maximum at 0.7, which agreed fairly well with the "uniform mixture ratio distribution" criteria of the Jet Propulsion Laboratory. Variation of impingement angle from 38 deg to 120 deg indicated that performance correlated with the absolute velocity ratio V(sub o)/V(sub f), but stability correlation appeared to be best with a velocity ratio using the radial component of the fuel injection velocity V(sub o)/V(sub fr). Impingement distances from 0.5 to 1.0 inch appeared to have only slight effect on stability and performance. Investigation of injector thrust per element for V(sub o)/V(sub fr) ranging from 0.8 to 2.8 yielded convex maxima curves. Acoustic liners were also tested to improve a liner design computer program, to obtain design criteria, and to develop flight-type liners. A marginally stable and spontaneously unstable combustor were used to evaluate linear configurations. All liners were effective in the marginally stable configuration, and only liners with large theoretical absorptivity were successful in the spontaneously unstable combustor.

Tabata, William K.↗

Automated Transmission Loss Measurement in the Structural Acoustic Loads and Transmission Facility at NASA Langley Research Center

A technique to measure the radiated acoustic intensity and transmission loss of panels is documented in this paper. This facility has been upgraded to include a test fixture that scans the acoustic intensity radiated from a panel on the anechoic receiving room side of the transmission loss window. The acoustic intensity incident on the panel from the reverberant side of the transmission loss window is estimated from measurements made using six stationary microphones in the reverberant source room. From the measured incident and radiated intensity, the sound power transmission loss is calculated. The setup of the facility and data acquisition system are documented. A transmission loss estimate of a typical panel is shown. The measurement-to-measurement and setup-to-setup repeatability of the transmission loss estimate are assessed. Conclusions are drawn about the ability to measure changes in transmission loss due to changes in panel construction.

Klos, J.↗