Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “.NET”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,297 records · Page 72

How representative are FLUXNET measurements of surface fluxes during temperature extremes?

In response to a warming climate, temperature extremes are changing in many regions of the world. Therefore, understanding how the fluxes of sensible heat, latent heat and net ecosystem exchange respond and contribute to these changes is important. We examined 216 sites from the open access Tier 1 FLUXNET2015 and free fair-use La Thuile data sets, focussing only on observed (non-gap-filled) data periods. We examined the availability of sensible heat, latent heat and net ecosystem exchange observations coincident in time with measured temperature for all temperatures, and separately for the upper and lower tail of the temperature distribution, and expressed this availability as a measurement ratio. We showed that the measurement ratios for both sensible and latent heat fluxes are generally lower (0.79 and 0.73 respectively) than for temperature measurements, and the measurement ratio of net ecosystem exchange measurements are appreciably lower (0.42). However, sites do exist with a high proportion of measured sensible and latent heat fluxes, mostly over the United States, Europe and Australia. Few sites have a high proportion of measured fluxes at the lower tail of the temperature distribution over very cold regions (e.g. Alaska, Russia) or at the upper tail in many warm regions (e.g. Central America and the majority of the Mediterranean region), and many of the world's coldest and hottest regions are not represented in the freely available FLUXNET data at all (e.g. India, the Gulf States, Greenland and Antarctica). However, some sites do provide measured fluxes at extreme temperatures, suggesting an opportunity for the FLUXNET community to share strategies to increase measurement availability at the tails of the temperature distribution. We also highlight a wide discrepancy between the measurement ratios across FLUXNET sites that is not related to the actual temperature or rainfall regimes at the site, which we cannot explain. Our analysis provides guidance to help select eddy covariance sites for researchers interested in understanding and/or modelling responses to temperature extremes.

54 ENVIRONMENTAL SCIENCES↗

Leveraging the signature of heterotrophic respiration on atmospheric CO 2 for model benchmarking

Spatial and temporal variations in atmospheric carbon dioxide (CO 2 ) reflect large-scale net carbon exchange between the atmosphere and terrestrial ecosystems. Soil heterotrophic respiration (HR) is one of the component fluxes that drive this net exchange, but, given observational limitations, it is difficult to quantify this flux or to evaluate global-scale model simulations thereof. Here, we show that atmospheric CO 2 can provide a useful constraint on large-scale patterns of soil heterotrophic respiration. We analyze three soil model configurations (CASA-CNP, MIMICS, and CORPSE) that simulate HR fluxes within a biogeochemical test bed that provides each model with identical net primary productivity (NPP) and climate forcings. We subsequently quantify the effects of variation in simulated terrestrial carbon fluxes (NPP and HR from the three soil test-bed models) on atmospheric CO 2 distributions using a three-dimensional atmospheric tracer transport model. Our results show that atmospheric CO 2 observations can be used to identify deficiencies in model simulations of the seasonal cycle and interannual variability in HR relative to NPP. In particular, the two models that explicitly simulated microbial processes (MIMICS and CORPSE) were more variable than observations at interannual timescales and showed a stronger-than-observed temperature sensitivity. Our results prompt future research directions to use atmospheric CO 2 , in combination with additional constraints on terrestrial productivity or soil carbon stocks, for evaluating HR fluxes.

54 ENVIRONMENTAL SCIENCES↗

A coupled ground heat flux–surface energy balance model of evaporation using thermal remote sensing observations

Abstract. One of the major undetermined problems in evaporation (ET) retrieval using thermal infrared remote sensing is the lack of a physically based ground heat flux (G) model and its integration within the surface energy balance (SEB) equation. Here, we present a novel approach based on coupling a thermal inertia (TI)-based mechanistic G model with an analytical surface energy balance model, Surface Temperature Initiated Closure (STIC, version STIC1.2). The coupled model is named STIC-TI. The model is driven by noon–night (13:30 and 01:30 local time) land surface temperature, surface albedo, and a vegetation index from MODIS Aqua in conjunction with a clear-sky net radiation sub-model and ancillary meteorological information. SEB flux estimates from STIC-TI were evaluated with respect to the in situ fluxes from eddy covariance measurements in diverse ecosystems of contrasting aridity in both the Northern Hemisphere and Southern Hemisphere. Sensitivity analysis revealed substantial sensitivity of STIC-TI-derived fluxes due to the land surface temperature uncertainty. An evaluation of noontime G (Gi) estimates showed 12 %–21 % error across six flux tower sites, and a comparison between STIC-TI versus empirical G models also revealed the substantially better performance of the former. While the instantaneous noontime net radiation (RNi) and latent heat flux (LEi) were overestimated (15 % and 25 %), sensible heat flux (Hi) was underestimated (22 %). Overestimation (underestimation) of LEi (Hi) was associated with the overestimation of net available energy (RNi−Gi) and use of unclosed surface energy balance flux measurements in LEi (Hi) validation. The mean percent deviations in Gi and Hi estimates were found to be strongly correlated with satellite day–night view angle difference in parabolic and linear pattern, and a relatively weak correlation was found between day–night view angle difference versus LEi deviation. Findings from this parameter-sparse coupled G–ET model can make a valuable contribution to mapping and monitoring the spatiotemporal variability of ecosystem water stress and evaporation using noon–night thermal infrared observations from future Earth observation satellite missions such as TRISHNA, LSTM, and SBG.

Bhattacharya, Bimal K.↗

Soil organic matter diagenetic state informs boreal forest ecosystem feedbacks to climate change

The fate of soil organic carbon (SOC) in boreal forests is dependent on the integrative ecosystem response to climate change. For example, boreal forest productivity is often nitrogen (N) limited, and climate warming can enhance N cycling and primary productivity. However, the net effect of this feedback on the SOC reservoir and its longevity with climate change remain unclear due to difficulty in detecting small differences between large and variable carbon (C) fluxes needed to determine net changes in soil reservoirs. The diagenetic state of SOC – resulting from the physicochemical and biological transformations that alter the original biomolecular composition of detrital inputs to soil over time – is useful for tracing the net response of SOC at the timescales relevant to climate change not usually discernible from fluxes and stocks alone. Here, we test two hypotheses using a mesic boreal forest climate transect: (1) the SOC diagenetic state is maintained across this climosequence, and (2) the maintenance of the SOC diagenetic state is a consequence of coupled soil C and N cycling, signifying the role of enhanced N cycling supporting SOC inputs that maintain SOC stocks within the warmer-climate forests. Shifts in nonvascular to vascular plant inputs with climate observed in these and other boreal forests highlighted the need to carefully separate biogeochemical indicators of SOC source from those signifying diagenetic alteration. We thus evaluated and applied lignin biomarkers to assess the diagenetic alteration of SOC in these boreal forest organic soils and directly compared the lignin diagenetic state with that of soil organic nitrogen (SON) assessed through amino acid composition. The lignin diagenetic state remained constant across the climate transect, indicating a balance between the input and removal of lignin in these mesic boreal forests. When combined with previous knowledge of these forest ecosystems, including the diagenetic state of SON and direct measures of C fluxes and stocks, the results indicate a coupled increase in C and N cycling with climate warming that supports forest productivity and maintains SOC stocks. This balance could markedly shift as other factors begin to limit forest productivity (e.g., trace nutrients, water) with further climate change or affect forest nutrient allocation (e.g., forest age or compositional change). Further application of the approach presented here could be used to detect the limits of this and other ecosystem–climate feedbacks, by providing a tractable and parameterizable index of the lignin state across large spatial scales, necessary for ecosystem-scale parameterizations.

54 ENVIRONMENTAL SCIENCES↗

CERF: IM3 Projected Western US Power Plant Locations

Overview The Capacity Expansion Regional Feasibility (CERF) model is an open-source geospatial python package that provides new power plant locations at a 1km resolution. The model ingests U.S. state or regional-scale electricity system capacity expansion plans, such as those produced by the Global Change Analysis Model (GCAM-USA), and identifies feasible, site-specific locations for individual new power plants (renewable and non-renewable). CERF combines high-resolution geospatial suitability analyses with an economic algorithm that selects individual plant siting locations based on grid interconnection costs and the locational marginal value of new generation. The model incorporates a wide range of dynamic constraints and opportunities, such as protected lands, population density, existing infrastructure, and water availability. This dataset provides CERF power plant siting results for IM3 Phase 2 simulations across eight different scenarios for the Western US through 2055. The scenarios include combinations of two Shared Socioeconomic Pathways (SSP3 and SSP5) with four high-resolution climate projections specific to the United States (see, https://tgw-data.msdlive.org/). These climate projections include "hotter" and "cooler" variants for two Representative Concentration Pathways (RCP4.5 and RCP8.5). The resulting eight simulations are: rcp45cooler_ssp3 rcp45cooler_ssp5 rcp45hotter_ssp3 rcp45hotter_ssp5 rcp85cooler_ssp3 rcp85cooler_ssp5 rcp85hotter_ssp3 rcp85hotter_ssp5 CERF siting results in this dataset correspond to capacity expansion plans in the GCAM-USA IM3 Phase 2 simulation data and are available for each of the above scenarios. Data Details Temporal Range: 2015-2055 in 5-year timesteps. Note that 2015 is the experiment base year and 2020 and beyond represent model simulation years. Spatial Range: Plant locations are provided for the eleven states in the Western US including Arizona, California, Colorado, Idaho, Montana, New Mexico, Nevada, Oregon, Utah, Washington, and Wyoming. Spatial Resolution: 1 km-squared, provided in x and y coordinates Geospatial Projection: Albers Equal Area Conic (ESRI:102003) File Type: csv The dataset contains subdirectories for each of the eight scenarios described in the overview. Each scenario folder contains two subfolders with the following information: 1. Power Plant Data This directory contains a single .csv file of power plant locations for both pre-existing (non-CERF sited plants in operation in 2015) and new (CERF-sited) power plants across the temporal range along with additional CERF model output parameters for CERF-sited plants. Plant with a siting year earlier than 2020 correspond to facilities that are operational leading into the first timestep CERF simulation. For a more detailed description of CERF model output parameters, see the CERF model documentation. Note that the cerf_plant_id parameter is unique within each scenario file but not across scenario files. Parameter Descriptions scenario - Name of scenario cerf_plant_id - Unique siting identifier cerf_sited - If True, indicates that plant was sited by CERF model. If False, indicates pre-existing facility region_name - Name of region (state) tech_id - Technology ID tech_name - Full generation technology name inclusive of cooling type (if applicable) and additional characteristics tech_simple - Simplified generation technology type unit_size_mw - Power plant unit size (MW) xcoord - X coordinate in the default CRS (meters) ycoord - Y coordinate in the default CRS (meters) index - Index position in the flattend 2D array buffer_in_km - Exclusion buffer around site (km) sited_year - Year of siting retirement_year - Year of retirement lmp_zone - Locational marginal price (LMP) zone ID locational_marginal_price_usd_per_mwh - Locational marginal price ($/MWh) generation_mwh_per_year - Generation output (MWh/yr) operating_cost_usd_per_year - Cost of plant operations ($/yr) net_operational_value - Net operational value based on LMP and and operating costs ($/yr) interconnection_cost - Cost of interconnection for transmission & gas pipeline (if applicable) net_locational_cost -- Difference of interconnection cost and operating value ($/yr) capacity_factor_fraction - Capacity factor (fraction) carbon_capture_rate_fraction - Carbon capture rate (fraction) fuel_co2_content_tons_per_btu - Fuel CO2 content (tons/Btu) fuel_price_usd_per_mmbtu - Fuel price ($/MMBtu) fuel_price_esc_rate_fraction - Fuel price escalation rate (fraction) heat_rate_btu_per_kWh - Heat rate (Btu/kWh) lifetime_yrs - Technology lifetime for annuity (years) operational_life_yrs - Operational lifetime for retirement (years) variable_om_usd_per_mwh - Variable operation and maintenance costs of yearly capacity use ($/MWh) variable_om_esc_rate_fraction - Variable operation and maintenance costs escalation rate (fraction) carbon_tax_usd_per_ton - Carbon tax ($/ton) carbon_tax_esc_rate_fraction - Carbon tax escalation rate (fraction) 2. Storage Data This directory contains information on new and pre-existing energy storage facilities operational in each timestep along with various storage operational parameters. The 2015 timestep provides pre-existing energy storage data and corresponds with facilities that are operational leading into the first model simulation timestep. Note that coordinates in the storage files correspond to the interconnection point on the grid (substation location), not individual energy storage locations. Energy storage is added in a cumulative process at each given interconnection point. That is, each individual file provides the total operational storage capacity interconnected to the specified substation for the given timestep, inclusive of previously installed storage at that location and new storage installed in that timestep at that location. Parameters scenario - Name of scenario timestep - Simulation timestep name - Unique storage identifier s_typ - Type of energy storage technology (battery or pumped storage hydro) s_node - Node ID of interconnecting substation xcoord - X coordinate in the default CRS (meters) ycoord - Y coordinate in the default CRS (meters) charge_rate - Maximum charge rate (power capacity) of storage system (MW) discharge_rate - Maximum discharge rate (power capacity) of storage system (MW) duration - Duration of storage system (hours) max_SoC - Allowed maximum state of charge (energy capacity) of storage system (MWh) min_SoC -Allowed minimum state of charge (energy capacity) of storage system (MWh) charge_eff - Efficiency of charge (fraction between 0 and 1) discharge_eff - Efficiency of discharge (fraction between 0 and 1) Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program.

CERF↗

TRAILS Output Files

Overview This data repository contains ZIP files that store compressed versions of the output of running the WaterPaths utility planning and management tool in the DU Re-Evaluation mode (to download the tool, please see this GitHub repository). The tool was used to simulate the six-utility North Carolina Research Triangle problem. Details on the contents of each ZIP file can be seen below. Data details Temporal range: Weekly data for 2,344 weeks from 2015 to 2060 (45 years). Spatial range: Six water utilities in the North Carolina Research Triangle region (0: Chapel Hil/OWASA, 1: Durham, 2: Cary, 3: Raleigh, 4: Pittsboro, and 5: Chatham) File types: CSV and OUT Different solutions available The solution numbers correspond to the different pathway strategies (henceforth referred to as "solutions") discussed in paper's main and supporting text (abstract and link to the paper here). They are as follows: Sol92: The Durham-focused pathway strategy Sol132: The Raleigh-focused pathway strategy Sol140: The regionally-robust pathway strategy Objectives files These files can be accessed by unzipping solXX_objectives_pathways.zip that contains 1,000 Objectives_RDMXX_solsXX_to_XX.csv files. Each CSV file will consist of a row representing all the objective values for that specific solution, while every six columns represents the reliability, restriction frequency, infrastructure net present value ($ mil), peak financial cost, worst-case cost, and unit cost ($ per MG; in that order) for each of the six utilities. There will be 1,000 such files, denoting the performance of the six utilities across the 1,000 deeply uncertain states of the world (DU SOWs). Pathway files These files can be accessed by unzipping solXX_objectives_pathways.zip that contains 1,000 Pathways_sXX_RDMXX.out file. Each OUT corresponds to the set of infrastructure being triggered in a specific DU SOW, and each file will have the name file will consist of four tab-delimited columns that are described as follows: Realization: The realization in which an infrastructure options being triggered utility: The utility currently triggering infrastructure week: The week in which a specific infrastructure option is being triggered infra.: The infrastructure option being triggered If the OUT file contains only the header line, no infrastructure was triggered for that specific DU SOW. Policies files These files can be obtained by unzipping Policies.zip. Each of the 1,000 CSV files within the unzipped folder will contain weekly water use restriction policies for all 1,000 hydroclimatic realizations within a specific DU SOW. The column structure is as follows: 0rest_m: restriction multiplier for utility 0 (values between 0 and 1) 1rest_m: restriction multiplier for utility 1 (values between 0 and 1) 2rest_m: restriction multiplier for utility 2 (values between 0 and 1) 3rest_m: restriction multiplier for utility 3 (values between 0 and 1) 4rest_m: restriction multiplier for utility 4 (values between 0 and 1) 5rest_m: restriction multiplier for utility 5 (values between 0 and 1) 0transf: transfer volume for utility 0 (in MGD) 1transf: transfer volume for utility 1 (in MGD) 2transf: transfer volume for utility 2 (in MGD) 3transf: transfer volume for utility 3 (in MGD) 4transf: transfer volume for utility 4 (in MGD) 5transf: transfer volume for utility 5 (in MGD) Water Sources files These files can be obtained by unzipping WaterSources_subset.zip. Each of the 100 CSV files within the unzipped folder will contain weekly state variables at each water source for all 1,000 hydroclimatic realizations within a specific DU SOW. The column structure is as follows: Xvolume: available water volume from source X (in MGD) Xs_area: surface area of source X (in ACF) Xdemand: demand drawn from a water source from source X (in MGD) Xup_spill: upstream spillage from source X (in MGD) Xww_inflow: wastewater inflow from source X (in MGD) Xcatch_inflow: upstream catchment inflow to source X (in MGD) Xevap: evaporation multiplier for source X (values between 0 and 1) Xds_spill: downstream spillage from source X (in MGD) X_Y_alloc_cap: the allocated capacity from source X to utility Y (values between 0 and 1) X_Y_alloc_dem: the allocated demand from source X to utility Y (values between 0 and 1) Xtrmt_alloc_Y: the allocated treatment capacity from source X to utility Y (values between 0 and 1) Utilities files These files can be obtained by unzipping Utilities_subset.zip. Each of the 100 CSV files within the unzipped folder will contain weekly state variables at each utility for all 1,000 hydroclimatic realizations within a specific DU SOW. The column structure is as follows: Xst_vol: total available storage volume of utility X (in MG) Xcapacity: total storage capacity of utility X (in MG) Xnet_inf: : net inflow for all storage infrastructure for utility X (in MGD) Xst_rof: short term ROF for utility X (values between 0 and 1) Xst_stor_rof: short-term storage ROF for utility X (values between 0 and 1) Xst_trmt_rof: short-term treatment ROF for utility X (values between 0 and 1) Xlt_rof: long-term ROF for utility X (values between 0 and 1) Xlt_stor_rof: long-term storage ROF for utility X (values between 0 and 1) Xlt_trmt_rof: long-term treatment ROF for utility X (values between 0 and 1) Xrest_demand: restricted demand for utility X (in MGD) Xunrest_demand: unrestricted demand for utility X (in MGD) Xunfulf_demand: unfulfilled demand for utility X (in MGD) Xwastewater: wastewater return for utility X (in MGD) Xtreat_capacity: total treatment capacity for utility X (in MG) Xcont_fund: reserve (contingency) fund balance for utility X Xins_pout: insurance payout for utility X (% annual volumetric revenue) Xins_price: insurance price for utility X (% annual volumetric revenue) Xinfra_npv: infrastructure net present value for utility ($mil) Xst_vol: total available storage volume of utility X (in MG) Xdebt_serv: debt service for utility X (usually once per year if the infrastructure is triggered; % annual volumetric revenue) Xstor_vol: total stored volume (in MGD) Xobs_ann_dem: observed annual demand for utility X (in MGD) Xproj_dem: projected annual demand for utility X (in MGD) Xpv_debt_serv: present value of debt service payments for utility X (% annual volumetric revenue) Xgross_rev: gross revenue for utility X ($mil) Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program.

Artificial Intelligence↗

Root bacterial endophytes alter plant phenotype, but not physiology

Plant traits, such as root and leaf area, influence how plants interact with their environment and the diverse microbiota living within plants can influence plant morphology and physiology. Here, we explored how three bacterial strains isolated from the Populus root microbiome, influenced plant phenotype. Here, we chose three bacterial strains that differed in predicted metabolic capabilities, plant hormone production and metabolism, and secondary metabolite synthesis. We inoculated each bacterial strain on a single genotype of Populus trichocarpa and measured the response of plant growth related traits (root:shoot, biomass production, root and leaf growth rates) and physiological traits (chlorophyll content, net photosynthesis, net photosynthesis at saturating light–A sat , and saturating CO 2 –A max ). Overall, we found that bacterial root endophyte infection increased root growth rate up to 184% and leaf growth rate up to 137% relative to non-inoculated control plants, evidence that plants respond to bacteria by modifying morphology. However, endophyte inoculation had no influence on total plant biomass and photosynthetic traits (net photosynthesis, chlorophyll content). In sum, bacterial inoculation did not significantly increase plant carbon fixation and biomass, but their presence altered where and how carbon was being allocated in the plant host.

58 GEOSCIENCES↗

Grid Service Values of Generic Marginal Building Flexibility in Modeled 2030 U.S. Power Systems

The datasets include the capacity, energy, and ancillary service values of a marginal kilowatt-hour (kWh) of generic, daily, shiftable building flexibility as a presumed market entrant in the 2030 U.S. power systems. The results should be interpreted along with the caveats listed in "Valuation of Building Flexibility: Grid Service Value for Initial Market Entrants in Projected 2030 United States Power Systems", which also documents the methods used for the study. The factors examined in the study include: grid scenario, region, original usage hour in the day (local time), and building flexibility parameters - efficiency, dissipation, and shifting window include max pre-shift and max post-shift. Filenames in the datasets: The filenames contain information on the grid scenario, and the building flexibility efficiency and dissipation. For example: MidCase_2030_efficiency1.25_dissipation0.05_value.csv contains all results under Mid RE 2020, efficiency = 1.25, and dissipation = 0.05. * MidCase = Mid RE Each .csv file contains: region: The location of the building flexibility, aligned with U.S. Energy Information Administration (EIA) National Energy Modeling System (NEMS) Electricity Market Module regions. max_pre_shift: Part of building flexibility shifting window parameter, indicates the max number of hours the building flexibility can shift earlier. max_post_shift: Part of building flexibility shifting window parameter, indicates the max number of hours the building flexibility can shift later. local_datetime: Original datetime of 1kWh of building energy consumption. local_orig_h: Original usage hour (1-24) of building energy consumption, ignores daylight saving. local_shift_to: The datetime to when building energy consumption shifts, if shifting happens. If no shifting occurs, this cell is left blank. energy: Net energy value of energy shifting. capacity: Net capacity value of energy shifting. shifting_value: Net energy plus capacity value of energy shifting. spin: Spin reserve value at the original datetime of consumption. flex: Flexible reserve value at the original datetime of consumption. reg: Regulation reserve value at the original datetime of consumption. total_profit: Assuming the building flexibility is capable of providing energy, capacity, and ancillary services, total profit is the maximum value of energy shifting value, spin reserve value, flexible reserve value, and regulation reserve value - one of the four choices at any given hour - because we do not allow its value to be double-counted.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Financial methods for waterflooding injectate design

A method of selecting an injectate for recovering liquid hydrocarbons from a reservoir includes designing a plurality of injectates, calculating a net present value of each injectate, and selecting a candidate injectate based on the net present value. For example, the candidate injectate may be selected to maximize the net present value of a waterflooding operation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Innovative Glazing Materials

Windows have the unique capability of being able to achieve a net zero energy impact by admitting solar gains in the winter to offset thermal losses and admitting daylight to offset electric lighting. If rejection or admission of solar heat gains and daylight are appropriately timed, then heating, cooling and lighting energy use at the perimeter zone can be reduced to net zero energy levels. Nano-scale switchable coatings on glass have been developed to actively modulate solar intensity and spectral transmission. We provide a brief overview of these switchable glazing materials, discuss the desired performance objectives for such materials, and present results from recently completed monitored studies of state-of-the-art switchable windows, particularly with respect to occupant response and market factors. Careful application of state-of-the-art switchable windows and new material science developments on the horizon can deliver the desired net zero energy performance while meeting critical human factors and market related requirements.

Building energy efficiency↗

Economic Assessment of Nuclear Hybrid Energy Systems: Nuclear-Renewable-Water Integration in Arizona

One of the goals of the Nuclear-Renewable Hybrid Energy Systems (N-R HES) modeling and simulation (M&S) project is to assess the economic viability of N-R HES in a market that contains Variable Renewable Energy (VRE) sources like solar. The N-R HES M&S project is a multi-laboratory effort, led by Idaho National Laboratory (INL) and supported by Argonne National Laboratory (ANL) and Oak Ridge National Laboratory (ORNL). Development of the N-R HES software framework was initiated at INL in 2016 [1] and has reached some level of maturity such that it can be applied to more than simple demonstration cases, e.g. real industry problems. Nevertheless, more capabilities are constantly added to accommodate the special needs of challenging, real-life problems. The N-R HES framework is built on the Risk Analysis Virtual ENvironment (RAVEN) code [2], which it uses as a driver and workflow manager for all calculations. There are four main cornerstones of the N-R HES simulation framework: 1) The generation of stochastic synthetic time series. 2) A set of probabilistic analysis and optimization algorithms available in RAVEN. 3) A set of models for representing the physical behavior of N-R HES. These can be reduced-order models or high-fidelity Modelica [3] models. 4) The RAVEN plug-in called CashFlow [4] that maps physical performance into economic performance. Within this framework, a broad spectrum of questions related to N-R HES can be addressed. One of the challenges currently of high interest is the increasing penetration of VRE altering the profile of the net demand (demand after removing all non-curtailable renewable energy sources, e.g. rooftop solar). The N-R HES software framework is capable of analyzing the potential feasibility of mitigating the resultant volatility in the net electricity demand. One possible solution to manage net demand volatility is adding stabilizing loads to the grid. These loads can be external industrial processes that are able to ramp production up and down quickly, or for regulated markets, adding variable internal loads that will effectively increase the baseload of the power plant and therefore reduce the risk of internal demand that is lower than the capacity of the power plant. The latter is a possible solution currently being considered by Arizona Public Service (APS), the operating owner of the Palo Verde (PV) Nuclear Power Plant (NPP).

97 MATHEMATICS AND COMPUTING↗

Optimal Sizing of an Electric Vehicle Charging Station with Integration of PV and Energy Storage

This paper proposes an optimization model for the optimal configuration of an grid-connected electric vehicle (EV) extreme fast charging station considering integration of photovoltaic (PV) and energy storage. The proposed model minimizes the annualized net cost (i.e., maximizes the annualized net profit) of the extreme fast charging station, including investment and maintenance cost of charging ports, PV and energy storage, net cost of purchasing energy from utility and selling energy to EV customers, degradation cost of energy storage and demand charge. The decision variables are number of charging ports, capacity of invested PV and the power and energy ratings of invested energy storage. The Erlang-loss system is adopted to model the EV mobility. Results of numerical simulations indicate that investment of PV and energy storage could increase the annualized profit of the extreme fast charging station. In addition, the impacts of various parameters on the optimal solution are investigated by sensitivity analysis.

Liu, Guodong↗

TEA and LCA Assessments of H2 Production from Coal, Coal/Biomass, and Biomass

This presentation was made at the "Gasification Technology Status and Pathways for Net-Zero Carbon Economy Workshop" held on November 30, 2022. The presentation primarily focuses on TEA/LCA results that NETL has developed for coal gasification w/ & w/o CCS as well as net-zero greenhouse gas coal/biomass gasification. Full reporting of these cases is publicly available in the NETL report titled "Comparison of Commercial, State-of-the-Art, Fossil-Based Hydrogen Production Technologies," April 2022. Additionally, the presentation describes current NETL work in support of the U.S. Department of Energy (DOE) Office of Fossil Energy and Carbon Management (FECM) Gasification Program in the areas of TEA/LCA/Markets analysis of biomass/MSW/waste plastics gasification to achieve cost reductions for net-zero H2 production.

Lewis, Eric↗

MA transmutation performance in the optimized MYRRHA

MYRRHA (multi-purpose hybrid research reactor for high-tech applications) is a multipurpose research facility currently being developed at SCK-CEN. It will be able to work in both critical and subcritical modes and, cooled by lead-bismuth eutectic. In this paper the minor actinides (MA) transmutation capabilities of MYRRHA are investigated. (Pu + Am, U) MOX fuel and (Np + Am + Cm, Pu) Inert Matrix Fuel test samples have been loaded in the central channel of the MYRRHA critical core and have been irradiated during five cycles, each one consisting of 90 days of operation at 100 MWth and 30 days of shutdown. The reactivity worth of the test fuel assembly was about 1.1 dollar. A wide range of burn-up level has been achieved, extending from 42 to 110 MWd/kg HM, the samples with lower MA-to-Pu ratios reaching the highest burn-up. This study has highlighted the importance of the initial MA content, expressed in terms of MA/Pu ratio, on the transmutation rate of MA elements. For (Pu + Am, U) MOX fuel samples, a net build-up of MA is observed when the initial content of MA is very low (here, 1.77 wt% MA/Pu) while a net decrease in MA is observed in the sample with an initial content of 5 wt%. This suggests the existence of some 'equilibrium' initial MA content value beyond which a net transmutation is achievable.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Potential Ancillary Services Revenue for Nuclear Power Plants with Thermal Energy Storage

A large-scale thermal energy storage system could be used by a nuclear power plant to counteract price volatility from wind and solar generation. The potential revenue available to the combined system could come from wholesale energy markets as well as ancillary services markets for capacity reserves and frequency regulation. We found that ancillary services may provide up to 1/3 of the total net revenue for an energy storage system, and adding energy storage to nuclear power plants increased net revenue in all scenarios we evaluated. However, adding four energy storage systems only marginally increased net revenue compared to two systems. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Recognizing Institutions that Prepare Students for 21st Century Building Careers

Buildings play a significant role in reaching the White House's goal of a net-zero emissions economy by 2050, so it is critical that building professionals are prepared to design and construct high-efficiency, low-carbon buildings powered by renewables. The U.S. Department of Energy's Zero Energy Design Designation recognizes post-secondary academic programs that prepare students for 21st century building careers. ZEDD is a three-year designation, and as of 2023 almost 40 programs of study from more than 25 institutions have been recognized and supported by DOE for their great work. The University of Cincinnati received the ZEDD designation for the Net Zero Energy Design Track in Architectural Engineering Program. Tracks, majors, minors, and certificates are all eligible for ZEDD. In recent interviews with faculty from the University of Cincinnati and Appalachian State University about their experiences with ZEDD, many common topics came up. Both faculty members mentioned their students who graduate with ZEDD on their resume are often the only people in their future design firms who understand and can create net zero energy designs.

buildings↗

Techno-Economic Viability of Flexible Dispatch of Unconventional Geothermal Systems

Flexible geothermal operations could boost project returns through the allocation of improved power purchase agreements and/or exploitation of power price arbitrage opportunities. In this study, we investigated the techno-economic feasibility of variable flow rate control and time-of-day pricing in closed-loop geothermal systems. We considered U-shaped multilateral system configurations and modeled a variety of technical system parameters. These designs were simulated using a slender-body theory (SBT) model for transient heat transfer and fluid flow. This subsurface model was integrated into the flexible geothermal economic model (FGEM) tool to evaluate the overall flexible geothermal system techno-economics. Future hourly ambient temperature conditions were based on the Sup3rCC dataset. Published datasets were used for future hourly wholesale electricity prices. We analyzed four operating strategies: 1) baseload operation, 2) seasonal dispatch (high flow rate during summer and nominal flow rate during the rest of the year), 3) net generation maximization by varying flow rate to maximize net power output, and 4) revenue maximization by varying flow rate to maximize revenue. We ran all four scenarios for a multiloop configuration with 12 lateral passes, 7-km vertical depth and 87-km total drilling length. Furthermore, we assumed a 60 degrees C/km geothermal gradient and ambient temperature and wholesale electricity prices for New Mexico as a typical state location. The nominal flow rate was set to 80 kg/s. When considering drilling costs of $1,000/m and a discount rate of 7%, the generation maximization scenario resulted in the lowest levelized cost of electricity (LCOE) of ~$150/MWh. When considering project return on investment (ROI), defined as lifetime net income divided by upfront capital costs, all flexible operation scenarios performed better than the base case scenario. The highest ROI of 80% was obtained with the revenue maximization scenario. With drilling costs of $200/m and a discount rate of 5%, the generation maximization scenario resulted in LCOE of $49/MWh.

flexible geothermal↗

Assembly Bowing Reactivity Calculation Methodology Applied to Lead Fast Reactor

Ducted assemblies bow during operation due to power and temperature gradients which can be influenced by operating flow rates. For fast spectrum cores using ducted assemblies, the bowing behavior follows that of the duct and because there are gaps between the ducts, the bowing can result in compaction or expansion of the active core. This local displacement can have a positive or negative impact and knowing the net effect during transients is important for system reactivity control. Keeping the net bowing reactivity worth low is possible with attentive placement of load pads above the active core and selecting load pad gap thicknesses that result in a desired behavior at standard operating conditions. This paper considers a Lead Fast Reactor (LFR) concept fueled by HALEU UO2 developed by Westinghouse Electric Company (WEC) and applies a workflow of Argonne-developed codes to estimate the core bowing reactivity worth. Using orifice flow rates grouped by assembly type, the net reactivity impact due to core assembly bowing for the LFR was found to be small and in line with other liquid metal fast reactors: +29/+32/+35 pcm, or about +$0.049/+$0.055/+$0.059, for BOEC/MOEC/EOEC, respectively.

bowing reactivity↗