At least 1,279 records · Page 71

Variable Permeability Magnetometer Systems and Methods for Aerospace Applications

A magnetometer configured to measure low field strength magnetic fields is provided. Certain embodiments of the magnetometer include a cylindrical coil assembly having a variable permeability core and terminals disposed at both ends. A current source circuit may be operably connected to the terminals and configured to apply a voltage controlled current across the terminals. A voltage readout circuit may be operably connected to the terminals and configured to measure a voltage across the terminals due to the applied current from the current source. An inductance of the coil assembly directly varies as an ambient magnetic field strength varies a permeability of the variable permeability core, and a voltage across the terminals varies directly with the inductance such that the measured voltage across the terminals is a direct measure of the ambient magnetic field strength.

Shams, Qamar A.↗

The Effect of a Hall Thruster-Like Magnetic Field on Operation of a 25-A Class Hollow Cathode

The effect of applying a Hall thruster-like magnetic field to a 25-A class hollow cathode is experimentally characterized. A magnetic simulator that approximated the magnetic field of NASA's HERMeS Hall thruster was used to apply magnetic fields of strengths that varied from 0 to 1.25 of the nominal HERMeS value Bnom. Cathode operation was characterized by parameters such as the discharge voltage, voltage and current oscillation magnitudes, and ion energy spectra. It was found that the application of the magnetic field profoundly affected the operation of the cathode. For the nominal xenon flow rate of 14.7 sccm, when increasing the magnetic field from 0 Bnom to 1.25 Bnom, the discharge voltage increased from 20 V to 40 V and the cathode orifice plate temperature increased from 934 ºC to 987 ºC. Oscillations of the discharge voltage, discharge current, and keeper voltage all remained relatively quiescent. However, the ion energy spectra changed profoundly between conditions, with little ion population above 50 V at 0 Bnom, yet a high-energy ion tail extending above 150 V at the 1.25 Bnom case. These high-energy ions appeared without an increase in the oscillation levels, indicating that previous cathode mode definitions may not apply with the Hall thruster-like magnetic field. The implications of these results on existing cathode operational mode definitions, component-level cathode testing, and operation in a Hall thruster are discussed.

Hall, Scott J.↗

The Effect of Anode Position on Operation of a 25-A Class Hollow Cathode

The effect of the distance between a hollow cathode and a cylindrical anode on cathode operation is investigated for two anode geometries. Neutral flow simulations demonstrate that the anode diameter and distance from the cathode exit can elevate the downstream pressure as much as two orders of magnitude above what the cathode experiences while operating within a Hall thruster. Based on the results of this modeling, two axially-segmented cylindrical molybdenum anodes were constructed: a 64-mm diameter one that replicated the anode geometry used in recent NASA hollow cathode development testing and a larger 254-mm diameter one designed to reduce the neutral pressure in front of the cathode to thruster-like values. For each anode design, cathode performance was characterized for varying anode/cathode distance using metrics such as discharge voltage and oscillation magnitudes, and the ion voltage spectra were characterized using a radially-positioned retarding potential analyzer. It was found that as local neutral pressure decreased, discharge voltage and high-voltage ion content in the plume increased. For the 254-mm diameter anode, an ion voltage tail in excess of 200 V was found for nominal cathode flow rates. The implications of these results for standalone hollow cathode development tests are discussed.

Hall, Scott J.↗

Robustness of Semi-Superjunction 4H-SiC Power DMOSFETs to Single-Event Burnout from Heavy Ion Bombardment

We compare the failure mechanism and performance of a silicon carbide (SiC) semi-superjunction (semi-SJ) power DMOSFET against pure SJ and conventional DMOSFET when struck by a single heavy ion. The Single-Event Burnout (SEB) failure mechanism was identified as the thermal runaway from second breakdown resulting in mesoplasma formation. The semi-SJ design shifts the mesoplasma location from the drift/substrate interface seen in the control device structures to a location along the center of the P-pillar and closer towards the DMOSFET surface, thus significantly improving the SEB threshold voltage. The SEB threshold voltage varies with pillar width and ratio of pillar thickness to drift layer thickness. A maximum value of SEB threshold voltage is reached when the pillar to drift layer ratio is 0.9 and the pillar width is 2.4 μm. The semi-SJ SEB/breakdown voltage ratio is 100% and 13% higher than the pure SJ and conventional DMOSFET, respectively. Using a new figure of merit (FOM), which accounts for the tradeoff between SEB threshold voltage and on-state performance, we find that the SiC semi-SJ DMOSFET achieves a FOM that is 1.8 and 8 times higher than SJ and conventional DMOSFET, respectively, making the semi-SJ a competitive candidate for radiation hardened applications.

SiC↗

Characterizing Electrical Arc Behavior in Ion Engines

Gridded ion engines represent a class of electric thrusters characterized by high propulsive efficiency and high total impulse capabilities. These engines operate by applying high voltage to multi-aperture electrodes, thereby electrostatically accelerating plasma to generate thrust. Within the course of normal operations, periodic occurrences of high voltage breakdowns manifest within the thruster. These breakdowns constitute an inherent aspect of operation, with observations indicating a diminishing frequency and total count over the thruster's operational lifespan. To safeguard the propulsion system during such occurrences, the power processing unit (PPU) employs an automated arc extinction sequence, termed "recycle," which is triggered upon detection of an over-current condition. The initial phase of this sequence involves momentarily deactivating the high voltage and reducing the discharge current to a predetermined level, minimizing plasma impingement as the ion beam is defocused. The high voltage is subsequently reapplied, and the discharge current is returned to its nominal value. The entire sequence typically spans approximately 800 milliseconds. Throughout a recycle event, the propulsion system experiences various current and voltage transients as the arc current traverses the system and different power supplies are toggled on and off.

electric propulsion↗

Evaluation of Aluminum Polymer Capacitors for Space Applications

Layered aluminum polymer capacitors (APC) may be viable replacements to currently used chip tantalum capacitors due to their lower ESR, weight, and smaller size. So far, there is a lack of information regarding the reliability of these parts. Available technical literature is mostly related to the effect of humidity. Although APCs have a limited moisture resistance, it may be contained to the level sufficient for space applications. This work analyzes construction and characteristics of seven types of commercial APCs manufactured by four vendors and rated to voltages from 6.3 to 35 V were analyzed. Their reliability under environmental stresses and highly accelerated life tests was assessed in the range of temperatures and voltages to determine reliability acceleration factors. For this purpose, characteristics of the parts, including breakdown voltages, the level of anomalous charging currents (ACC), capacitance, DF, ESR and leakage currents were measured in the process of storage at high-temperatures (from 100 to 150 °C) and high humidity at 85 °C. Monitored highly accelerated life tests have been carried out at temperatures of 85 °C and 125 °C and voltages varying from 1.2 to 1.9 times the rated voltage. Degradation processes and reliability of APCs have been compared to polymer tantalum capacitors.

Alexander A Teverovsky↗

Measurements of noise in Josephson-effect mixers

We present new heterodyne receiver results obtained at 100 GHz using resistively-shunted Nb and NbN tunnel junctions. In addition, we have carried out accurate measurements of the available noise power of these devices at the L-band (1.5 GHz) IF (infrasonic) frequency. Both the heterodyne and the output noise measurements show that the noise of these devices can be a factor of five or more higher than that predicted by the simple current-biased RSJ model. The noise approaches the appropriate thermal or thermal and shot noise limits for bias voltages where the nonlinearity is not strong (i.e., V greater than I(sub C)R(sub N)), but as expected from the RSJ model, can be significantly higher at the low voltages where the mixers are typically biased. The bias voltage dependence of the noise shows structure which is associated with resonances in the RF embedding circuit. Surprisingly, we find that changes in the high-frequency (100 GHz) impedance presented to the junction can dramatically affect the magnitude and voltage dependence of the low-frequency (1.5 GHz) noise. This emphasizes the necessity of very closely matching the junction to free space over a wide frequency range.

NOISE MEASUREMENT↗

System measures response time of photomultiplier tubes

Calibration system enables precise determination of rise time of photosensitive detectors. To perform a calibration, the time-voltage curve of the excitation voltage for a light source is compared with the time-voltage curve of the voltage output from a photosensitive detector which is responding to the light.

Lauver, M. R.↗

Dielectric breakdown in a dilute plasma.

Description of tests performed to determine the effects of high voltages on dielectrics that are to insulate solar cell arrays operating at voltages up to 16 kV from the electrically active plasma of the space environment at 500 km altitude. The tests were performed on dielectrics considered for this application at positive bias voltages as high as 20 kV dc relative to ground in an argon plasma with electron number densities of approximately one million per cu cm. Teflon specimens displayed higher breakdown voltages than all other dielectrics tested.

Mckinzie, D. J., Jr.↗

Solid state d.c. power controller design philosophies and their evaluation.

Evaluation of remote power controllers (RPC), which has enhanced knowledge of the capabilities of various design philosophies and has indicated certain limitations that RPC's exhibit. Additionally, this activity has clearly emphasized that certain RPC design parameters merit further consideration in development. The major design parameters to be analyzed in more detail are the rates of change of the rise and fall times of the output current. The major reason why transient voltages and currents should be reduced is the minimization of the reverse collector-to-emitter voltage. The requirement for higher bus voltage coupled with the present problem of improving the efficiency of power control points out the urgent need for improvement and advancement of higher current, voltage, and gain power semiconductors.

Maus, L. G.↗

Computer acquired performance data from a chemically vapor-deposited-rhenium, niobium planar diode

Performance data from a chemically vapor-deposited-rhenium, niobium thermionic converter are presented. The planar converter has a guard-ringed collector and a nominal fixed spacing of 0.25 mm (10 mils). The data were obtained by using a computerized acquisition system and are available on request to one of the authors on microfiche as individual and composite parametric current, voltage curves. The parameters are the temperatures of the emitter T sub E collector T sub C, and cesium reservoir T sub R. The composite plots have constant T sub E and varying T sub C or T sub R, or both. Current, voltage envelopes having constant T sub E with and without fixed T sub C appear in the present report. The diode was tested at increments between 1600 and 2000 K for the emitter Hohlraum, 800 to 1100 K for the collector, and 540 and 650 K for the reservoir. A total of 312 current, voltage curves were obtained in the present performance evaluation. Current, voltage envelopes from three rhenium emitter converters evaluated in the present program are also given. The data are compared at commom emitter Hohlraum temperatures.

Manista, E. J.↗

Converter design techniques and applications

Transistorized direct current voltage converters offer a number of advantages over other types because of their small size, low weight, high efficiency, high reliability, precision accuracy and wide range of control. There are three basic types of converter subsystems: series converter in which a voltage-controlled component is placed in series with the load; shunt converter in which a current-controlled component is placed in shunt with the load; and a switching converter in which a voltage-controlled component is turned on and off in series with the load. Converters employing any of these three types of subsystems can provide constant voltage, constant current, or constant impedance across the load. Design and application considerations, step-by-step design procedures, and the solution to sample design problems for the series, shunt, and switching types are presented.

Lalli, V. R.↗

Closed cycle MHD power generation experiments in the NASA Lewis Facility

Many modifications were made in the MHD facility. These include a redesign of the MHD duct interior, addition of mixing bars, increased electrical isolation of all the high temperature components from each other and from ground, and experimentation with various cesium seed vaporization and injection techniques. With the exception of the cesium system which needs further improvement the above modifications were quite successful and resulted in improvements in generator performance. The facility was run for a total of 400 hours in the past year, with 70 hours of this operation at temperatures of 2000 K or more with hot generator walls. With the exception of replacing one cracked brick in the MHD channel no repairs were required in the high temperature loop components for the duration of these tests. Uniform Faraday and Hall voltage profiles were obtained and the Faraday open circuit voltage varied from 90 to 100 percent of the ideal uBh. The magnitudes of the measured parameters are: Faraday open circuit voltage approximately 70 V, total Faraday current approximately 20 A, Hall voltage approximately 250 V, power output approximately 300 W, and power density .036 W/cu cm.

Sovie, R. J.↗

Evaluation program for secondary spacecraft cells: Initial evaluation tests of General Electric Company 6.0 ampere hour nickel-cadmium spacecraft cells with auxiliary electrodes for the atmospheric Explorer satellite C and D

The capacity of the cells ranged from 6.6 to 7.6 ampere hours during the three capacity tests. No voltage requirements or limits were exceeded during any portion of the test. All cells recovered to a voltage in excess of 1.193 volts during the 24-hour open-circuit portion of the internal short test. All the cells reached a pressure of 20 psia before reaching the voltage limit of 1.550 volts during the pressure versus capacity test. The average ampere/hours in and voltages at this pressure were 9.1 and 1.513, respectively. All cells exhibited pressure decay in the range of 1 to 5 psia during the last 30 minutes of the 1-hour open circuit stand. Average capacity out was 7.2 ampere/hours.

Harkness, J. D.↗

Load insensitive electrical device

A class of power converters is described for supplying direct current at one voltage from a source at another voltage. It includes a simple passive circuit arrangement of solid-state switches, inductors, and capacitors by which the output voltage of the converter tends to remain constant in spite of changes in load. The switches are sensitive to the current flowing in the circuit and are employed to permit the charging of capacitance devices in accordance with the load requirements. Because solid-state switches (such as SCR's) may be used with relatively high voltage and because of the inherent efficiency of the invention that permits relatively high switching frequencies, power supplies built in accordance with the invention, together with their associated cabling, can be substantially lighter in weight for a given output power level and efficiency of operation than systems of the prior art.

Schwarz, F. C.↗

Low distortion automatic phase control circuit

A voltage controlled phase shifter is rendered substantially harmonic distortion free over a large dynamic input range by employing two oppositely poled, equally biased varactor diodes as the voltage controlled elements which adjust the phase shift. Control voltages which affect the bias of both diodes equally are used to adjust the phase shift without increasing distortion. A feedback stabilized phase shifter is rendered substantially frequency independent by employing a phase detector to control the phase shift of the voltage controlled phase shifter.

Hauge, G.↗

Effects of insulator ablation on the operation of a quasi-steady MPD arc

Multimegawatt operation of quasi-steady MPD arcjets can involve serious ablation of the insulator surfaces within the arc discharge chamber. Various degrees of insulator ablation manifest themselves by significantly perturbing the voltage-current characteristics and the exhaust velocity profiles. Voltage-current characteristics for two different insulator materials, Plexiglas and boron nitride, are interpreted in terms of an empirical Ohm's law. Use of the refractory insulator material eliminates the ablation-dominated nature of the terminal voltage, but the exhaust stream is still disturbed by insulator material. An Alfven critical velocity model can be applied to this influence of insulator ablation on exhaust velocity. Appropriate changes in the propellant injection geometry eliminate this influence and result in arcjet operation which is independent of insulator material. A particular combination of propellant injection geometries reduces the terminal voltage for a given current and mass flow while maintaining insulator-independent operation, thus implying an improvement in the overall efficiency of the device.

Boyle, M. J.↗

Hydrostatics and steady dynamics of spatially varying electromechanical flow structures

The hydrostatic and steady laminar hydrodynamic equilibria of spatially varying electromechanical flow structures are investigated. Under certain conditions the relationship between the dielectric height of rise and the applied voltage is found to be double valued. It is found that one of the two equilibrium values is always unstable. This gives rise to the experimentally observed spontaneous rise of the fluid to the top of the structure, once a certain critical voltage is reached. Starting above this critical voltage with the structure completely filled and decreasing the applied voltage toward the critical value results in pinch-in failure at an intermediate point along the structure and trapping of dielectric fluid at the top. The simple mathematical model developed predicts all these phenomena, without recourse to tedious point-by-point surface force equilibrium determination. Experiments are reported which verify the results for the hydrostatic case.

Jones, T. B.↗