Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “time integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Effect of photon counting shot noise on total internal reflection microscopy

Total internal reflection microscopy (TIRM) measures changes in the distance between a colloidal particle and a transparent substrate by measuring the scattering intensity of the particle illuminated by an evanescent wave. From the distribution of the recorded separation distances, the height-dependent effective potential φ(z) between the colloidal particle and the substrate can be measured. In this work, we show that spatial resolution with which TIRM can measure φ(z) is limited by the photon counting statistics of the scattered laser light. Here, we develop a model to evaluate the effect of photon counting statistics on different potential profiles using Brownian dynamics simulations and experiments. Our results show that the effect of photon counting statistics depends on spatial gradients ∂φ/∂z of the potential, with the result that sharp features tend to be significantly blurred. We further establish the critical role of photon counting statistics and the intensity integration time τ in TIRM measurements, which is a trade-off between narrowing the width of the photon counting distribution and capturing the instantaneous position of the probe particle.

47 OTHER INSTRUMENTATION↗

Single particle – MC-ICP-MS for isotopic analysis of uranium particles

Single particle – multi-collector – inductively coupled plasma – mass spectrometry (SP-MC-ICP-MS) was employed to measure a suspension of 1 µm U3O8 particles (∼1.3 pg total U/particle) to determine their individual isotopic compositions of 234U/238U, 235U/238U, and 236U/238U. The effects of different detector combinations for 235U and 238U, including secondary electron multipliers (SEM) and Faraday detectors (1011 and 1013 Ω amplifiers), were explored for accuracy and precision optimization on the observed 235U/238U. The minor isotopic ratios (i.e., 234U/238U and 236U/238U) were analyzed such that the 234U and 236U were monitored on SEM detectors and the 238U was monitored on a Faraday (1011 Ω) detector. Various integration times (5, 10, 25, and 50 ms) were investigated in all detector configurations to gain a better understanding of their impact on sensitivity, accuracy, and precision. For 235U/238U ratios of 1 µm U3O8 particles, a dual Faraday detector measurement with 1011 Ω was the optimal choice; measurement of 1021 particles yielded an average 235U/238U ratio of 0.00170 (14), a −1.8% relative difference (% RD) from the reference value. The minor isotopic compositions were determined to be 0.0000070 (14) and 0.0000758 (48) for the 234U/238U and 236U/238U, respectively. These measurements correspond to <8% and <1% RD from their reference value for the 234U/238U and 236U/238U, respectively. SP-MC-ICP-MS was also able to provide insight into measurement sensitivity. In these individual particles, merely 15 and 165 atto-grams (ag) of 234U and 236U were present (calculated). Initial limits of detection for SP-MC-ICP-MS were determined to be ∼1.0 ag (when measured via SEM detectors). This valuable approach is applicable to areas including nuclear forensics, nuclear safeguards, and geochemical analysis, which require high-precision measurements of uranium within micron-sized particles.

Manard, Benjamin [ORNL] (ORCID:0000000207400627)↗

Planck 2015 results: XX. Constraints on inflation

In this paper, we present the implications for cosmic inflation of the Planck measurements of the cosmic microwave background (CMB) anisotropies in both temperature and polarization based on the full Planck survey, which includes more than twice the integration time of the nominal survey used for the 2013 release papers. The Planck full mission temperature data and a first release of polarization data on large angular scales measure the spectral index of curvature perturbations to be n s = 0.968 ± 0.006 and tightly constrain its scale dependence to dn s / dlnk = -0.003 ± 0.007 when combined with the Planck lensing likelihood. When the Planck high-ℓ polarization data are included, the results are consistent and uncertainties are further reduced. The upper bound on the tensor-to-scalar ratio is r 0.002 < 0.11 (95% CL). This upper limit is consistent with the B-mode polarization constraint r< 0.12 (95% CL) obtained from a joint analysis of the BICEP2/Keck Array and Planck data. These results imply that V(φ) ∝ φ 2 and natural inflation are now disfavoured compared to models predicting a smaller tensor-to-scalar ratio, such as R 2 inflation. We search for several physically motivated deviations from a simple power-law spectrum of curvature perturbations, including those motivated by a reconstruction of the inflaton potential not relying on the slow-roll approximation. We find that such models are not preferred, either according to a Bayesian model comparison or according to a frequentist simulation-based analysis. Three independent methods reconstructing the primordial power spectrum consistently recover a featureless and smooth P R (k)over the range of scales 0.008 Mpc -1 ≲ k ≲ 0.1 Mpc -1 . At large scales, each method finds deviations from a power law, connected to a deficit at multipoles ℓ ≈ 20-40 in the temperature power spectrum, but at an uncompelling statistical significance owing to the large cosmic variance present at these multipoles. By combining power spectrum and non-Gaussianity bounds, we constrain models with generalized Lagrangians, including Galileon models and axion monodromy models. The Planck data are consistent with adiabatic primordial perturbations, and the estimated values for the parameters of the base Λ cold dark matter (ΛCDM) model are not significantly altered when more general initial conditions are admitted. In correlated mixed adiabatic and isocurvature models, the 95% CL upper bound for the non-adiabatic contribution to the observed CMB temperature variance is | α non - adi | < 1.9%, 4.0%, and 2.9% for CDM, neutrino density, and neutrino velocity isocurvature modes, respectively. We have tested inflationary models producing an anisotropic modulation of the primordial curvature power spectrum finding that the dipolar modulation in the CMB temperature field induced by a CDM isocurvature perturbation is not preferred at a statistically significant level. We also establish tight constraints on a possible quadrupolar modulation of the curvature perturbation. Lastly, these results are consistent with the Planck 2013 analysis based on the nominal mission data and further constrain slow-roll single-field inflationary models, as expected from the increased precision of Planck data using the full set of observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Do not forget the electrons: Extending moderately-sized nuclear networks for multidimensional hydrodynamic codes

Context.Nuclear networks are widely used coupled with hydrodynamical simulations of explosive scenarios to account for the change of nuclear species and energy generation rate due to nuclear reactions. In this way, there is a feedback mechanism between the hydrodynamical state and the nuclear processes. Unfortunately, the timescale of nuclear reactions is orders of magnitude smaller than the dynamical timescale that drives hydrodynamical simulations. Therefore, these nuclear networks are usually very small, reduced in most cases to a dozen elements, especially when simulations are carried out in more than one dimension. Aims.We present here an extended nuclear network, with 90 species, designed for being coupled with hydrodynamic simulations, which includes neutrons, protons, electrons, positrons, and the corresponding neutrino and anti-neutrino emission. This network is also coupled with temperature, making it extremely robust and, together with its size, unique of its kind. The inclusion of electron captures on free protons makes the network very appropriate for multidimensional studies of Type Ia supernova explosions, especially when the exploding object is a massive white dwarf. Methods.We perform several tests that are relevant to simulate explosive scenarios, such as Type Ia supernovae and core-collapse supernovae. We compare the results of the 90 nuclei network with a standardα-chain network with 14 elements to evaluate the differences in the energy generation rate. We also evaluate the relevance of including the electrons in the network in terms of generated yields and how it affects the pressure of a degenerate fluid such as that of white dwarfs. The results obtained with the 90-nuclei network have been verified with a much larger 2000-nuclei network built from REACLIB (WinNet), in terms of nuclear energy generation rate, pressure, and produced yields. Results.The results obtained with the proposed medium-sized network compare fairly well, to a few percent, with those computed withWinNetin scenarios reproducing the gross physical conditions of current Type Ia supernova explosion models. In those cases where the carbon and oxygen fuel ignites at high density, the high-temperature plateau typical of the nuclear statistical equilibrium regime is well defined and stable, allowing large integration time steps. We show that the inclusion of electron captures on free protons substantially improves the estimation of the electron fraction of the mixture. Therefore, the pressure is better determined than in networks where electron captures are excluded, which will ultimately lead to more reliable hydrodynamic models. Explosive combustion of helium at low density, occurring near the surface layer of a white dwarf, is also better described with the proposed network, which gives nuclear energy generation rates much closer toWinNetthan typical reduced alpha networks. Conclusions.A nuclear network withN= 90 species, including electrons, aimed at multidimensional calculations of supernova explosions is described and verified. The proposed network is suitable for the study of Type Ia supernova explosions because it provides better values of pressure and electron abundance than other existing networks with smaller or even a similar size but without including electron capture processes.

Astronomy & Astrophysics↗

Measured indoor PM2.5, black carbon, and oxidative potential before and after replacing gas with induction cooking in asthmatic households

Cooking is a major source of fine particulate matter (PM) in homes and evidence to date is inconclusive about the impact of cooking fuel on measures of residential PM exposure. The Cooking Energy and Ventilation Impacts on Children's Asthma (CEVICA) study measured cooking frequency, range hood use, indoor air quality (IAQ) and respiratory health indicators of children with asthma living in homes with gas stoves in California's San Joaquin Valley. Intensive measurements occurred over three 2-week intensive periods: at baseline and at the end of two consecutive 3-month study phases. Participants were randomly assigned to have their gas stoves replaced with electric induction at the start of Phase 1 or Phase 2. As part of the IAQ assessment, we collected particulate matter on Teflon filters using ultrasonic personal air samplers (UPAS). The filters were analyzed to quantify time-integrated PM 2.5 mass concentration, black carbon (BC) oxidative potential (OP). OP was measured using the SLF-OH assay, an acellular chemical assay that quantifies production of OH radicals in simulated lung fluid (SLF). Across all comparisons, PM 2.5 mass tended to be higher during gas cooking than induction electric cooking, although only one transition (Baseline to Phase 1) was statistically discernible at p<0.05. BC and mass-normalized OP showed no measurable differences across stove types or across phases. These preliminary findings suggest that stove fuel alone may not be the dominant determinant of indoor PM 2.5 concentrations in this sample, as previous studies have reported that indoor PM 2.5 during cooking can also be influenced by factors such as cooking practices, food and oil type, kitchen ventilation, and outdoor infiltration.

Lin, Zhuoying↗

Experimental Studies of Fast Protons Originated from Fusion Reactions in Plasma-Focus Discharges

The paper describes results of the recent measurements of fusion-reaction protons, which were performed within the PF-360 facility operated at the IPJ in Swierk, Poland. The main aim of those studies was to perform time-integrated measurements of fast protons (of energy of about 3 MeV) by means of ion-pinhole cameras, which were equipped with solid state nuclear track detectors (SSNTD) of the PM-355 type and absorption filters made of thin metal foils. In order to determine the spatial distribution of fusion-produced protons the use was made of several miniature pinhole cameras placed at different angles to the PF-360 axis. The irradiated and etched detectors were analyzed with an optical microscope coupled with a CCD camera and a PC unit.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high-resolution coherent transition radiation diagnostic for laser-produced electron transport studies (invited)

High-resolution images of the rear-surface optical emission from high-intensity (I{approx}10{sup 19} W/cm{sup 2}) laser illuminated metal foils have been recorded using coherent transition radiation (CTR). CTR is generated as relativistic electrons, generated in high-intensity laser-plasma interactions, exit the target's rear surface and move into vacuum. A transition radiation diagnostic (TRD) records time-integrated images in a 24 nm bandwidth window around {lambda}=529 nm. The optical transmission at {lambda}=1053 nm, the laser wavelength, is 15 orders of magnitude lower than the transmission at the wavelength of interest, {lambda}=527 nm. The detector is a scientific grade charge-coupled device (CCD) camera that operates with a signal-to-noise ratio of 10{sup 3} and has a dynamic range of 10{sup 4}. The TRD has demonstrated a spatial resolution of 1.4 {mu}m over a 1 mm field of view, limited only by the CCD pixel size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-pinch x-ray sources driven by a 1 {mu}s capacitor discharge

X pinches formed from tungsten, molybdenum, titanium, aluminum, and alloys, such as constantan and nichrome with diameters of 13-25 {mu}m, have been imploded with a 300 kA, 1 {mu}s quarter-period capacitor discharge and observed with an array of diagnostics including time-integrated optical photography, x-ray pinhole cameras, x-ray Si photodiodes, a flat crystal spectrograph, and a Nd:YAG laser interferometry/schlieren system. The results of these comprehensive observations are presented. When a single, central hot spot is formed with the right choice of wire and x-ray filter, it is observed to be highly localized, very bright and small enough that point projection radiography can be routinely demonstrated for a simple biological specimen. For an aluminum X pinch, spectroscopic measurements indicate that the hot spots have a plasma density and electron temperature consistent with {approx}10{sup 20} cm{sup -3} and {approx}320-350 eV, respectively.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation Of The Seismic Performance Of Masonry Buildings Of The Type 'Gaioleiro', Lisbon (Portugal)

This paper presents a numerical study that aims at the seismic evaluation of the performance of typical Portuguese 'gaioleiro' 19{sup th} century buildings. Numerical analysis was performed using a finite element model and was calibrated with experimental results obtained in 1:3 reduced scale tests done in the LNEC 3D shaking table.With the purpose of defining an adequate strategy for seismic performance evaluation, nonlinear dynamical analysis with time integration and pushover analyses were carried out. In the dynamic analysis, each earthquake is composed by two uncorrected artificial accelerograms compatible with the design response spectrum of EC8. In the pushover analyses it was considered that the seismic action is simulated through a set of horizontal forces proportional to the mass of structure and to the 1{sup st} vibration mode according to the direction being studied.

58 GEOSCIENCES↗

OZSPEC-2: An improved broadband high-resolution elliptical crystal x-ray spectrometer for high-energy density physics experiments (invited)

A novel time, space, and energy-resolved x-ray spectrometer has been developed which produces, in a single snapshot, a broadband and relatively calibrated spectrum of the x-ray emission from a high-energy density laboratory plasma. The opacity zipper spectrometer (OZSPEC-1) records a nearly continuous spectrum for x-ray energies from 240 to 5800 eV in a single shot. The second-generation OZSPEC-2, detailed in this work, records fully continuous spectra on a single shot from any two of these three bands: 270-650, 660-1580, and 1960-4720 eV. These instruments thus record thermal and line radiation from a wide range of plasmas. These instruments' single-shot bandwidth is unmatched in a time-gated spectrometer; conversely, other broadband instruments are either time-integrated (using crystals or gratings), lack spectral resolution (diode arrays), or cover a lower energy band (gratings). The OZSPECs are based on the zipper detector, a large-format (100x35 mm) gated microchannel plate detector, with spectra dispersed along the 100 mm dimension. OZSPEC-1 and -2 both use elliptically bent crystals of OHM, RAP, and/or PET. Individual spectra are gated in 100 ps. OZSPEC-2 provides one-dimensional spatial imaging with 30-50 {mu}m resolution over a 1500 {mu}m field of view at the source. The elliptical crystal design yields broad spectral coverage with resolution E/{delta}E>500, strong rejection of hard x-ray backgrounds, and negligible source broadening for extended sources. Near-term applications include plasma opacity measurements, detailed spectra of inertial fusion Hohlraums, and laboratory astrophysics experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optical beam profile monitor and residual gas fluorescence at the relativistic heavy ion collider polarized hydrogen jet

A gas fluorescence beam profile monitor has been implemented at the relativistic heavy ion collider (RHIC) using the polarized atomic hydrogen gas jet, which is part of the polarized proton polarimeter. RHIC proton beam profiles in the vertical plane of the accelerator are obtained as well as measurements of the width of the gas jet in the beam direction. For gold ion beams, the fluorescence cross section is sufficiently large so that profiles can be obtained from the residual gas alone, albeit with long light integration times. We estimate the fluorescence cross sections that were not known in this ultrarelativistic regime and calculate the beam emittance to provide an independent measurement of the RHIC beam. This optical beam diagnostic technique, utilizing the beam induced fluorescence from injected or residual gas, offers a noninvasive particle beam characterization and provides visual observation of proton and heavy ion beams.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectrally Resolved Intensities of Ultra-Dense Hot Aluminum Plasmas

We present a first study of spectroscopic determination of electron temperature and density spatial profiles of aluminum K-shell line emission spectra from laser-shocked aluminum experiments performed at LULI. The radiation emitted by the aluminum plasma was dispersed with an ultra-high resolution spectrograph ({lambda}/{delta}{lambda}{approx_equal}6000). From the recorded films one can extract a set of time-integrated emission lineouts associated with the corresponding spatial region of the plasma. The observed spectra include the Ly{alpha}, He{beta}, He{gamma}, Ly{beta} and Ly{gamma} line emissions and their associated He- and Li-like satellites thus covering a photon energy range from 1700 eV to 2400 eV approximately. The data analysis rely on the ABAKO/RAPCAL computational package, which has been recently developed at the University of Las Palmas de Gran Canaria and takes into account non-equilibrium collisional-radiative atomic kinetics, Stark broadened line shapes and radiation transport calculations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sensitivity of ignition scale backlit thin-shell implosions to hohlraum symmetry in the foot of the drive pulse

A necessary condition for igniting indirectly driven inertial confinement fusion spherical capsules on the National Ignition Facility (NIF) is controlling drive flux asymmetry to the 1% level time-integrated over the pulse and with <10%/ns swings during the pulse [J. D. Lindl, P. Amendt, R. L. Berger et al., Phys. Plasmas 11, 339 (2003)]. While drive symmetry during the first 2 ns of the pulse can be inferred by using the re-emission pattern from a surrogate high Z sphere and symmetry during the last 5 ns inferred from the shape of fully imploded capsules, the midportion ({approx_equal}2-10 ns) has been shown to be amenable to detection by the in-flight shape of x-ray backlit thin-shell capsules. In this paper, we present sensitivity studies conducted on the University of Rochester's OMEGA laser [J. Soures, R. L. McCrory, C. P. Verdon et al., Phys. Plasmas 3, 2108 (1996)] of the thin-shell symmetry measurement technique at near NIF-scale for two candidate capsule ablator materials: Ge-doped CH and Cu-doped Be. These experiments use both point and area backlighting to cast 4.7 keV radiographs of thin 1.4 mm initial-diameter Ge-doped CH and Cu-doped Be shells when converged by a factor of {approx_equal}0.5 in radius. Distortions in the position of the transmission limb of the shells resulting from drive asymmetries are measured to an accuracy of a few micrometers, meeting requirements. The promising results to date allow us to compare measured and predicted distortions and by inference drive asymmetries for the first four asymmetry modes as a function of hohlraum illumination conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A broadband absorption spectrometer using light emitting diodes for ultrasensitive, in situ trace gas detection

A broadband absorption spectrometer has been developed for highly sensitive and target-selective in situ trace gas measurements. The instrument employs two distinct modes of operation: (i) broadband cavity enhanced absorption spectroscopy (BBCEAS) is used to quantify the concentration of gases in sample mixtures from their characteristic absorption features, and (ii) periodic measurements of the cavity mirrors' reflectivity are made using step-scan phase shift cavity ringdown spectroscopy (PSCRDS). The latter PSCRDS method provides a stand-alone alternative to the more usual method of determining mirror reflectivities by measuring BBCEAS absorption spectra for calibration samples of known composition. Moreover, the instrument's two modes of operation use light from the same light emitting diode transmitted through the cavity in the same optical alignment, hence minimizing the potential for systematic errors between mirror reflectivity determinations and concentration measurements. The ability of the instrument to quantify absorber concentrations is tested in instrument intercomparison exercises for NO{sub 2} (versus a laser broadband cavity ringdown spectrometer) and for H{sub 2}O (versus a commercial hygrometer). A method is also proposed for calculating effective absorption cross sections for fitting the differential structure in BBCEAS spectra due to strong, narrow absorption lines that are under-resolved and hence exhibit non-Beer-Lambert law behavior at the resolution of the BBCEAS measurements. This approach is tested on BBCEAS spectra of water vapor's 4v+{delta} absorption bands around 650 nm. The most immediate analytical application of the present instrument is in quantifying the concentration of reactive trace gases in the ambient atmosphere. The instrument's detection limits for NO{sub 3} as a function of integration time are considered in detail using an Allan variance analysis. Experiments under laboratory conditions produce a 1{sigma} detection limit of 0.25 pptv for a 10 s acquisition time, which improves with further signal averaging to 0.09 pptv in 400 s. Finally, an example of the instrument's performance under field work conditions is presented, in this case of measurements of the sum of NO{sub 3}+N{sub 2}O{sub 5} concentrations in the marine boundary layer acquired during the Reactive Halogens in the Marine Boundary Layer field campaign.

36 MATERIALS SCIENCE↗

Analysis of Compact Cylindrical Wire Array Implosions with Brass and also by Alternating Brass and Al wires on the 1-MA COBRA Generator

Implosions from compact cylindrical wire arrays (CCWA) with mid-Z and low-Z wires were carried out on the 1-MA COBRA generator at Cornell University. In particular, the CCWA used either Brass 310 (70% Cu, 30% Zn) wires or a combination of Brass 310 and Al 5056 (95% Al, 5% Mg) wires arranged in an alternating pattern. A total of 16 wires were used on either a 6 or 4 mm diameter array. The diagnostic suite included a bolometer, fast x-ray detectors, a time-integrated spectrometer, and a streak camera. A higher energy output was observed from bolometer measurements when alternating the brass and Al wires compared to using only the brass wires. This study will focus mainly on the spectroscopy of the brass and alternating brass and Al CCWA by applying the non-LTE kinetic models of Cu and Zn to account for the L-shell radiation. The resulting plasma parameters, electron density and electron temperature, will be discussed and compared for the CCWA with only brass wires and alternating brass and Al wires. The simulations with the novel Wire Ablation Dynamics Model that account for wire ablation will be performed to analyze the differences in implosion dynamics of the uniform and alternating compact cylindrical arrays.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic Field Measurements in Plasmas: Beyond the Traditional Zeeman Spectroscopy

We discuss a new approach to measure magnetic fields in situations where the magnetic-field properties and/or the plasma regime make the traditional Zeeman spectroscopy inapplicable. The approach is particularly useful when the field direction and/or magnitude vary significantly in the region viewed or during the diagnostic system's integration time, and hence no Zeeman splitting can be observed. Similar difficulty may also occur for high-energy-density conditions, where the Zeeman pattern is often completely smeared, regardless of the field distribution, due to the dominant contributions of the Stark and Doppler broadenings to the spectral-line shapes. In the new approach, the magnetic field is inferred from the comparison of the line-shapes of different fine-structure components of the same multiplet, which practically have the same Stark and Doppler broadenings, but different magnetic-field-induced contributions. Limitations of the new method are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnostic based modeling for determining absolute atomic oxygen densities in atmospheric pressure helium-oxygen plasmas

Absolute atomic oxygen ground state densities in a radio-frequency driven atmospheric pressure plasma jet, operated in a helium-oxygen mixture, are determined using diagnostic based modeling. One-dimensional numerical simulations of the electron dynamics are combined with time integrated optical emission spectroscopy. The population dynamics of the upper O 3p {sup 3}P ({lambda}=844 nm) atomic oxygen state is governed by direct electron impact excitation, dissociative excitation, radiation losses, and collisional induced quenching. Absolute values for atomic oxygen densities are obtained through comparison with the upper Ar 2p{sub 1} ({lambda}=750.4 nm) state. Results for spatial profiles and power variations are presented and show excellent quantitative agreement with independent two-photon laser-induced fluorescence measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Boron ion source based on planar magnetron discharge in self-sputtering mode

An ion source based on a planar magnetron sputtering device with thermally isolated target has been designed and demonstrated. For a boron sputtering target, high target temperature is required because boron has low electrical conductivity at room temperature, increasing with temperature. The target is well-insulated thermally and can be heated by an initial low-current, high-voltage discharge mode. A discharge power of 16 W was adequate to attain the required surface temperature (400 C), followed by transition of the discharge to a high-current, low-voltage mode for which the magnetron enters a self-sputtering operational mode. Beam analysis was performed with a time-of-flight system; the maximum boron ion fraction in the beam is greater than 99%, and the mean boron ion fraction, time-integrated over the whole pulse length, is about 95%. We have plans to make the ion source steady state and test with a bending magnet. This kind of boron ion source could be competitive to conventional boron ion sources that utilize compounds such as BF3, and could be useful for semiconductor industry application.

43 PARTICLE ACCELERATORS↗