Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “thin membrane”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Development of Microwave Resonant Cavity Transducer Recalibration Procedures

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. For this test, we have developed a cylindrical resonator, which was machined from stainless steel 316 and electroplated with silver on the interior surfaces. Inner diameter of the cylindrical cavity is 22.2 mm, and the thin wall is approximately 200µm thick. The cavity was excited through a WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. Sodium flow rate sensing study was performed in a liquid sodium vessel at 340°C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred KHz was observed. From the measurements, we observed significant scatter in high temperature liquid sodium at low flow velocity values. Our hypothesis is that this is caused by temperature drift in the liquid, which results in thermal expansion of the cavity and a drift in the resonator frequency. In this report, we investigate temperature dependence of the resonant frequency through development of analytic models and preliminary analysis of experimental data. In addition, we develop a procedure for compensation for temperature drift during flow sensing.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The production of ultrathin polyimide films for the solar sail program and Large Space Structures Technology (LSST): A feasibility study

Polyimide membranes of a thickness range from under 0.01 micron m to greater than 1 micron m can be produced at an estimated cost of 50 cents per sq m (plus the cost of the polymer). The polymer of interest is dissolved in a solvent which is solube in water. The polymer or casting solution is allowed to flow down an inclined ramp onto a water surface where a pool of floating polymer develops. The solvent dissolves into the water lowering the surface tension of the water on equently, the contact angle of the polymer pool is very low and the edge of the pool is very thin. The solvent dissolves from this thin region too rapidly to be replenished from the bulk of the pool and a solid polymer film forms. Firm formation is rapid and spontaneous and the film spreads out unaided, many feet from the leading edge of the pool. The driving force for this process is the exothermic solution of the organic solvent from the polymer solution into the water.

Forester, R. H.↗

Microfluidic Platforms for on-chip Formulation and Small-Angle x-ray Analysis of the Phase Behavior of Lipid/Water Mixtures

We present a microfluidic platform for on-chip formulation and X-ray analysis of lipidic mesophases formed upon mixing lipids and water. The platform is designed to study the effect of detergents on the phase behavior of lipid/water mixtures. The platform allows automated preparation of multiple samples of different composition from stock solutions and subsequent on-chip small-angle X-ray diffraction (SAXS) data collection. To ensure X-ray transparency of the platform we used thin layers of cyclic olefin copolymer (COC) and PDMS. The viability of the platform is demonstrated by mapping out a section of the phase diagram for lipid monoolein mixed with solutions of detergent {beta}-octylglucoside. The platform reported here is a viable alternative to the traditional method of establishing phase diagrams for lipid/solution mixtures. Compared to the conventional approach, a significantly smaller amount of sample is required for mapping phase diagrams of lipidic mesophases and samples of various compositions are prepared automatically. In ongoing work we are using these chips to rapidly determine the phase behavior of a range of lipids to establish their suitability for membrane protein crystallization, especially with respect to their sensitivity to detergent concentration.

59 BASIC BIOLOGICAL SCIENCES↗

In-house synthesized poly(ether ether ketone) ionenes. I. ToF-SIMS spectra in the positive ion mode

Static time-of-flight secondary ion mass spectrometry (ToF-SIMS) was performed for acquiring the high-resolution surface spectra of four types of synthesized imidazolium ionene membranes. These novel membranes have aromatic ether–ketone–ether linkages inspired by poly(ether ether ketone) (PEEK). The PEEK-ionenes synthesized for this study have imidazolium cations placed in the polymeric backbone with bistriflimide [Tf 2 N]- counterions. The attention given to synthetically modified PEEK derivatives, such as PEEK-ionenes, is considerable due to their ability to selectively capture CO 2 molecules and other light gases. Therefore, it is important to characterize the surface of these synthesized novel PEEK-ionenes. In this work, characteristic and unique peaks were identified in the positive spectra of each sample. The differences in mass spectra among the samples provide insights for optimizing or fine-tuning the PEEK-ionenes synthesis to achieve a high-performance CO 2 separation membrane with enhanced permeability, selectivity, and mechanical stability. The SIMS spectra and identified characteristic peaks of these synthesized ionenes will serve as a reference in the positive mode, complementing the corresponding spectra reported in the negative ion mode (Paper II).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Amorphous Silk Fibroin Membranes for Separation of CO2

Amorphous silk fibroin has shown promise as a polymeric material derivable from natural sources for making membranes for use in removing CO2 from mixed-gas streams. For most applications of silk fibroin, for purposes other than gas separation, this material is used in its highly crystalline, nearly natural form because this form has uncommonly high tensile strength. However, the crystalline phase of silk fibroin is impermeable, making it necessary to convert the material to amorphous form to obtain the high permeability needed for gas separation. Accordingly, one aspect of the present development is a process for generating amorphous silk fibroin by treating native silk fibroin in an aqueous methanol/salt solution. The resulting material remains self-standing and can be prepared as thin film suitable for permeation testing. The permeability of this material by pure CO2 has been found to be highly improved, and its mixed-gas permeability has been found to exceed the mixed-gas permeabilities of several ultrahigh-CO2-permeable synthetic polymers. Only one of the synthetic polymers poly(trimethylsilylpropyne) [PTMSP] may be more highly permeable by CO2. PTMSP becomes unstable with time, whereas amorphous silk should not, although at the time of this reporting this has not been conclusively proven.

Aberg, Christopher M.↗

Broad-band efficiency calibration of ITER bolometer prototypes using Pt absorbers on SiN membranes

The energy resolved efficiency of two bolometer detector prototypes for ITER with 4 channels each and absorber thicknesses of 4.5 μm and 12.5 μm, respectively, has been calibrated in a broad spectral range from 1.46 eV up to 25 keV. The calibration in the energy range above 3 eV was performed against previously calibrated silicon photodiodes using monochromatized synchrotron radiation provided by five different beamlines of Physikalische Technische Bundesanstalt at the electron storage rings BESSY II and Metrology Light Source in Berlin. For the measurements in the visible range, a setup was realised using monochromatized halogen lamp radiation and a calibrated laser power meter as reference. The measurements clearly demonstrate that the efficiency of the bolometer prototype detectors in the range from 50 eV up to ≈6 keV is close to unity; at a photon energy of 20 keV the bolometer with the thick absorber detects 80% of the photons, the one with the thin absorber about 50%. This indicates that the detectors will be well capable of measuring the plasma radiation expected from the standard ITER scenario. However, a minimum absorber thickness will be required for the high temperatures in the central plasma. At 11.56 keV, the sharp Pt-L{sub 3} absorption edge allowed to cross-check the absorber thickness by fitting the measured efficiency to the theoretically expected absorption of X-rays in a homogeneous Pt-layer. Furthermore, below 50 eV the efficiency first follows the losses due to reflectance expected for Pt, but below 10 eV it is reduced further by a factor of 2 for the thick absorber and a factor of 4 for the thin absorber. Most probably, the different histories in production, storage, and operation led to varying surface conditions and additional loss channels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

VitroJet: new features and case studies

Single-particle cryo-electron microscopy has become a widely adopted method in structural biology due to many recent technological advances in microscopes, detectors and image processing. Before being able to inspect a biological sample in an electron microscope, it needs to be deposited in a thin layer on a grid and rapidly frozen. The VitroJet was designed with this aim, as well as avoiding the delicate manual handling and transfer steps that occur during the conventional grid-preparation process. Since its creation, numerous technical developments have resulted in a device that is now widely utilized in multiple laboratories worldwide. It features plasma treatment, low-volume sample deposition through pin printing, optical ice-thickness measurement and cryofixation of pre-clipped Autogrids through jet vitrification. This paper presents recent technical improvements to the VitroJet and the benefits that it brings to the cryo-EM workflow. A wide variety of applications are shown: membrane proteins, nucleosomes, fatty-acid synthase, Tobacco mosaic virus, lipid nanoparticles, tick-borne encephalitis viruses and bacteriophages. These case studies illustrate the advancement of the VitroJet into an instrument that enables accurate control and reproducibility, demonstrating its suitability for time-efficient cryo-EM structure determination.

59 BASIC BIOLOGICAL SCIENCES↗

Mobilifilum chasei: morphology and ecology of a spirochete from an intertidal stratified microbial mat community

Spirochetes were found in the lower anoxiphototrophic layer of a stratified microbial mat (North Pond, Laguna Figueroa, Baja California, Mexico). Ultra-structural analysis of thin sections of field samples revealed spirochetes approximately 0.25 micrometer in diameter with 10 or more periplasmic flagella, leading to the interpretation that these spirochetes bear 10 flagellar insertions on each end. Morphometric study showed these free-living spirochetes greatly resemble certain symbiotic ones, i.e., Borrelia and certain termite spirochetes, the transverse sections of which are presented here. The ultrastructure of this spirochete also resembles Hollandina and Diplocalyx (spirochetes symbiotic in arthropods) more than it does Spirochaeta, the well known genus of mud-dwelling spirochetes. The new spirochete was detected in mat material collected both in 1985 and in 1987. Unique morphology (i.e., conspicuous outer coat of inner membrane, large number of periplasmic flagella) and ecology prompt us to name a new free-living spirochete.

Non-NASA Center↗

Simultaneously Blocking Chemical Crosstalk and Internal Short Circuit via Gel-Stretching Derived Nanoporous Non-Shrinkage Separator for Safe Lithium-Ion Batteries

The separator, an ionic permeable and electronic insulating membrane between cathode and anode, plays a crucial role in the electrochemical and safety performance of batteries. However, the commercial polyolefin separators not only suffer from inevitable thermal shrinkage at elevated temperature, but also fail to inhibit the hidden chemical crosstalk of reactive gases such as O 2 , leading to often reported thermal runaway (TR) and hence preventing large-scale implementation of high-energy-density lithium-ion batteries. Herein, a nanoporous non-shrinkage separator (GS-PI) was fabricated via a novel gel-stretching orientation approach to eliminate TR. In situ synchrotron small angle X-ray scattering during heating clearly showed that the as-prepared thin GS-PI separator exhibits superior mechanical tolerance at high temperature, thus effectively preventing internal short circuit. Meanwhile, the unique nanoporous structure design further blocks chemical crosstalk and the associated exothermic reactions. Accelerating Rate Calorimetry test revealed that the practical 1 Ah LiNi 0.6 Co 0.2 Mn 0.2 O 2 (NCM622)/graphite pouch cell using GS-PI nanoporous separator show a maximum temperature rise (dT/dt max ) of only 3.7 °C s -1 compared to 131.6 °C s -1 in the case of Al 2 O 3 @PE macroporous separator. Furthermore, despite the reduced pore size, the GS-PI separator demonstrates better cycling stability than conventional Al 2 O 3 @PE separator at high temperature without sacrificing specific capacity and rate capability.

25 ENERGY STORAGE↗

Polyimide as a durable cathode for all-solid-state Li(Na)–organic batteries with boosted cell-level energy density

The integration of organic electrode materials (OEMs) with solid-state electrolytes (SSEs) is expected to build an all-solid-state battery (ASSB) with long-term sustainability, high safety, and high energy density. Despite this great promise, the cell-level energy density is still far from practically applicable, which stems from the ultrathick SSE layer and thin cathode layer used in a pellet-type ASSB design. Here, a cost-effective polyimide (PI) material was first exploited as an organic cathode for sulfide-based ASSBs. A capacity of ~190 mAh g -1 was delivered with almost no capacity decay over 300 cycles. Moreover, for the first time, a dry-film approach was introduced to manufacture a sheet-type Li–organic ASSB with an ultrathin SSE layer and a high-areal-loading PI cathode. Notably, PI is a perfect candidate for dry-film technology due to its high thermal stability and extraordinary chemical inertness toward sulfide SSEs. Remarkably, the free-standing SSE membrane was merely 46 μm thick, and an ultralow areal resistance of 3.3 Ω cm 2 was achieved, more than tenfold lower than that of reported SSE pellets. One order of magnitude boost in the cell-level energy density was achieved. This work presents a significant leap in transferring organic ASSB technology from laboratory research to factory manufacturing.

25 ENERGY STORAGE↗

Performance of a Multifunctional Space Evaporator- Absorber-Radiator (SEAR)

The Space Evaporator-Absorber-Radiator (SEAR) is a nonventing thermal control subsystem that combines a Space Water Membrane Evaporator (SWME) with a Lithium Chloride Absorber Radiator (LCAR). The LCAR is a heat pump radiator that absorbs water vapor produced in the SWME. Because of the very low water vapor pressure at equilibrium with lithium chloride solution, the LCAR can absorb water vapor at a temperature considerably higher than the SWME, enabling heat rejection by thermal radiation from a relatively small area radiator. Prior SEAR prototypes used a flexible LCAR that was designed to be installed on the outer surface of a portable life support system (PLSS) backpack. This paper describes a SEAR subsystem that incorporates a very compact LCAR. The compact, multifunctional LCAR is built in the form of thin panels that can also serve as the PLSS structural shell. We designed and assembled a 2 sq ft prototype LCAR based on this design and measured its performance in thermal vacuum tests when supplied with water vapor by a SWME. These tests validated our models for SEAR performance and showed that there is enough area available on the PLSS backpack shell to enable heat rejection from the LCAR.

Izenson, Michael G.↗

Defect Tolerance and Nanomechanics in Transistors that Use Semiconductor Nanomaterials and Ultrathin Dielectrics

This paper describes experimental and theoretical studies of the mechanics of free-standing nanoribbons and membranes of single-crystalline silicon transfer printed onto patterned dielectric layers. The results show that analytical descriptions of the mechanics agree well with experimental data, and they explicitly reveal how the geometry of dielectric layers (i.e., the width and depth of the features of relief) and the silicon (i.e., the thickness and widths of the ribbons) affect mechanical bowing (i.e., “sagging”) in the suspended regions of the silicon. Here, this system is of practical importance in the use of semiconductor nanomaterials for electronic devices, because incomplete sagging near defects in gate dielectrics provides a level of robustness against electrical shorting in those regions which exceeds that associated with conventional deposition techniques for thin films. Field effect transistors formed using silicon nanoribbons transferred onto a range of ultrathin gate dielectrics, including patterned epoxy, organic self-assembled monolayers, and HfO 2 , demonstrate these concepts.

36 MATERIALS SCIENCE↗

Dynamic quasistatic characterization of finite elements for shell structures.

Finite elements for shell structures have been investigated extensively, with numerous formulations offered in the literature. These elements are vital in modern computational solid mechanics due to their computational efficiency and accuracy for thin and moderately thick shell structures, allowing larger and more comprehensive (e.g. multi-scale and multi-physics) simulations. Problems now of interest in the research and development community are routinely pushing our computational capabilities, and thus shell finite elements are being used to deliver efficient yet high quality computations. Much work in the literature is devoted to the formulation of shell elements and their numerical accuracy, but there is little published work on the computational characterization and comparison of shell elements for modern solid mechanics problems. The present study is a comparison of three disparate shell element formulations in the Sandia National Laboratories massively parallel Sierra Solid Mechanics code. A constant membrane and bending stress shell element (Key and Hoff, 1995), a thick shell hex element (Key et al., 2004) and a 7-parameter shell element (Buechter et al., 1994) are available in Sierra Solid Mechanics for explicit transient dynamic, implicit transient dynamic and quasistatic calculations. Herein these three elements are applied to a set of canonical dynamic and quasistatic problems, and their numerical accuracy, computational efficiency and scalability are investigated. The results show the trade-off between the relative inefficiency and improved accuracy of the latter two high quality element types when compared with the highly optimized and more widely used constant membrane and bending stress shell element.

36 MATERIALS SCIENCE↗

Review of hydro-instability experiments with alternate capsule supports in indirect-drive implosions on the National Ignition Facility

Hydrodynamic instability growth of capsule support membranes (or “tents”) has been recognized as one of the major contributors to the performance degradation in high-compression plastic capsule implosions at the National Ignition Facility (NIF). The capsules were supported by tents because the nominal 10-μm diameter fill tubes were not strong enough to support capsules by themselves in indirect-drive implosions on NIF. After it was recognized that the tents had a significant impact of implosion's stability, new alternative support methods were investigated. While some of these methods completely eliminated tent, other concepts still used tents, but concentrated on mitigating their impact. The tent-less methods included “fishing pole” reinforced fill tubes, cantilevered fill tubes, and thin-wire “tetra cage” supports. In the “fishing pole” concept, a 10-μm fill tube was inserted inside 30-μm fill tube for extra support with the connection point located 300 μm away from the capsule surface. The cantilevered fill tubes were supported by 12-μm thick SiC rods, offset by up to 300 μm from the capsule surfaces. In the “tetra-cage” concept, 2.5-μm thick wires (carbon nanotube yarns) were used to support a capsule. Other concepts used “polar tents” and a “foam-shell” to mitigate the effects of the tents. The “polar tents” had significantly reduced contact area between the tents and the capsule compared to the nominal tents. In the “foam-shell” concept, a 200-μm thick, 30 mg/cc SiO 2 foam layer was used to offset the tents away from the capsule surface in an attempt to mitigate their effects. These concepts were investigated in x-ray radiography experiments and compared with perturbations from standard tent support. The measured perturbations in the “fishing pole,” cantilevered fill tube, and “tetra-cage” concepts compared favorably with (were smaller than) nominal tent perturbations and were recommended for further testing for feasibility in layered DT implosions. The “polar tents” were tested in layered DT implosions with a relatively-stable “high-foot” drive showing an improvement in neutron yield in one experiment compared to companion implosions with nominal tents. Furthermore, this article reviews and summarizes recent experiments on these alternate capsule support concepts. In addition, the concept of magnetic levitation is also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demonstration of Microwave Cavity Transducer Performance in High Temperature Fluid Flow Sensing: Development of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment, which is similar to that of an advanced reactor. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. For this test, we have developed a cylindrical resonator, which was machined from stainless steel 316 and electroplated with silver on the interior surfaces. Outer diameter of the cylindrical cavity is approximately 3cm, and the thin wall is approximately 200µm thick. We have also developed and insertion probe consisting of a 50cm WR-42 brass waveguide enclosed in a protective SS316 tube. The cavity was excited through a WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. As a calibration experiment, we have assembled a water vessel with a center feed, and with dimensions similar to those of the liquid sodium setup. Frequency shift of the cavity spectral response was obtained at room temperature and ambient pressure by gradually increasing water flow rate from 0 to 25GPM (gallons per minute). Corresponding monotonic increase of resonant frequency by several hundred KHz was observed. Next, a sodium flow rate sensing study was performed in a liquid sodium vessel at 340° C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred KHz was observed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Chemically Inert Hydrocarbon-Based Slurries for Rapid Laser Sintering of Thin Proton-Conducting Ceramics

The process of rapid laser sintering of thin BaZrO 3 –BaCeO 3 -based proton-conducting electrolytes is being developed for easy fabrication of ceramic fuel cells and electrolyzers. However, cracks on the electrolytes caused by volume change due to chemical reactions between the basic ceramic constituents and the polar solvents during wet processing has been problematic. In order to address this issue, the use of chemically inert saturated-hydrocarbon-based slurries comprised of hexadecane, polybutene, and a long-chain saturated fatty acid were investigated in this work. By optimizing slurry composition and laser sintering conditions, a 20 mm long, 4 mm wide, 13.5-μm-thick and 97%-dense BaCe 0.7 Zr 0.1 Y 0.07 Sm 0.13 O 3-d membrane showing proton conductivity on the order of 10 –4 S•cm –1 at 600 °C was successfully prepared in just three seconds by laser sintering. As a result, the use of saturated-hydrocarbon-based slurries will facilitate wet processing and rapid laser sintering of proton-conducting ceramic electrolytes.

36 MATERIALS SCIENCE↗

Performance of a Multifunctional Space Evaporator-Absorber-Radiator (SEAR)

The Space Evaporator-Absorber-Radiator (SEAR) is a nonventing thermal control subsystem that combines a Space Water Membrane Evaporator (SWME) with a Lithium Chloride Absorber Radiator (LCAR). The LCAR is a heat pump radiator that absorbs water vapor produced in the SWME. Because of the very low water vapor pressure at equilibrium with lithium chloride solution, the LCAR can absorb water vapor at a temperature considerably higher than the SWME, enabling heat rejection sufficient for most EVA activities by thermal radiation from a relatively small area radiator. Prior SEAR prototypes used a flexible LCAR that was designed to be installed on the outer surface of a portable life support system (PLSS) backpack. This paper describes a SEAR subsystem that incorporates a very compact LCAR. The compact, multifunctional LCAR is built in the form of thin panels that can also serve as the PLSS structural shell. We designed and assembled a 2 ft² prototype LCAR based on this design and measured its performance in thermal vacuum tests when supplied with water vapor by a SWME. These tests validated our models for SEAR performance and showed that there is enough area available on the PLSS backpack shell to enable rejection of metabolic heat from the LCAR. We used results of these tests to assess future performance potential and suggest approaches for integrating the SEAR system with future space suits.

Izenson, Michael G.↗

An on sun parametric study of solar hydrogen production using WO{sub 3} photoanodes

The solar production of hydrogen using photoactive electrodes is a topic receiving much attention in recent years. The use of thin metal oxide films as photoanodes allows the water splitting reaction to occur at a much lower applied voltage than would be necessary with a straight electrolysis process. The University of Nevada Las Vegas in collaboration with the UK based firm Hydrogen Solar and funded by the United States Department of Energy, has developed a prototype of this type of cell using a WO{sub 3} photoanode. An on-sun test facility has been constructed by the UNLV Center for Energy Research (CER) where a study is being conducted with regard to the effects various design parameters on the rate of hydrogen evolution. Parameters being studied include electrolyte temperature, electrolyte flow rate, electrolyte resistivity, applied voltage, and membrane to electrode spacing. The data collected is used in a parametric study of the cell performance. The results of this study are then used to establish general trends as to the effects of these parameters on the performance of the cells outside of a laboratory environment. (author)

08 HYDROGEN↗