Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “thermal testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

ECAR-6330 Rev 0 Computational Fluid Dynamics Evaluation of Core Pressure Drop for the Primary Coolant Apparatus Test

PCAT is a thermal-hydraulic test loop for MARVEL reactor. The design gap thickness between the heater rods of PCAT core is 1.0 mm. The heater elements were manufactured within a straightness tolerance for the designed gap thickness, but several elements have been distorted out of tolerance during the welding process. The distortion of heater rods could lead to flow maldistribution and excessive hotspot temperature when the gap between two heater rods is too narrow. Wire-wraps are the spacer devices widely used in the sodium cooled fast reactor system to maintain the design fuel pitch. Generally, a wire spacer can enhance the turbulent heat transfer, but it increases the pressure drop, which is not desirable for a natural-circulation system like PCAT. Therefore, three short wire-wrap spacers per heater have been proposed to contain the core pressure drops and keep the heater-to-heater gap in an acceptable range. The objectives of this ECAR is to evaluate the PCAR core pressure drop with short wire spacers to confirm that the additional pressure drop due to the wire spacer will not disturb the natural circulation of the PCAT.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Proportional and Integral Thermal Control System for Large Scale Heating Tests

The National Aeronautics and Space Administration Armstrong Flight Research Center (Edwards, California) Flight Loads Laboratory is a unique national laboratory that supports thermal, mechanical, thermal/mechanical, and structural dynamics research and testing. A Proportional Integral thermal control system was designed and implemented to support thermal tests. A thermal control algorithm supporting a quartz lamp heater was developed based on the Proportional Integral control concept and a linearized heating process. The thermal control equations were derived and expressed in terms of power levels, integral gain, proportional gain, and differences between thermal setpoints and skin temperatures. Besides the derived equations, user's predefined thermal test information generated in the form of thermal maps was used to implement the thermal control system capabilities. Graphite heater closed-loop thermal control and graphite heater open-loop power level were added later to fulfill the demand for higher temperature tests. Verification and validation tests were performed to ensure that the thermal control system requirements were achieved. This thermal control system has successfully supported many milestone thermal and thermal/mechanical tests for almost a decade with temperatures ranging from 50 F to 3000 F and temperature rise rates from -10 F/s to 70 F/s for a variety of test articles having unique thermal profiles and test setups.

Thermal Control System↗

Hypervelocity impact testing of Shuttle Orbiter thermal protection system tiles

Results are presented from a series of 22 hypervelocity impact tests carried out on the thermal protection system (TPS) for the Shuttle Orbiter. Both coated and uncoated low-density (0.14 g/cu cm) LI-900 and high-density (0.35 g/cu cm) LI-2200 tiles were tested. The results are used to develop the penetration and damage correlations which can be used in meteoroid and debris hazard analyses for spacecraft with a ceramic tile TPS. It is shown that tile coatings act as a 'bumper' to fragment the impacting projectile, with thicker coating providing increased protection.

Christiansen, Eric L.↗

DEVELOPMENT OF A LOW HEAT LEAK CFRP STAND FOR MIRI COOLER JT HEAT EXCHANGER STAGE

A low heat leak stand is being developed for the Heat exchanger Stage Assembly (HSA) of the cryocooler subsystem for the Mid Infra-Red Instrument (MIRI) of the James Webb Space Telescope (JWST). The HSA stand is a hexapod structure supporting the 18 K HSA in a nominal 40 K background environment. Carbon fiber reinforced plastic (CFRP) has been selected for this application to meet the stringent design requirements of a low parasitic heat leak (less than 3.8 mW including both conductive and radiative heat loads for the thermal environment defined above) and a resonance frequency above 120 Hz. A directional lay-up of T300/polycyanate has been chosen for the construction of the hexapod struts. End fittings made of Invar 36 are bonded to the struts to provide structural interfaces. The development effort includes fabricating and testing (including cryogenic thermal cycling) six types of coupons for material characterization, determination of structural degradation due to thermal cycling, and selection of the joint bonding epoxy. Consequently, strut samples are used for final material characterization, performance assessment, and bond joint design evaluation. This paper describes the development process and addresses the challenges in meeting the design requirements. Results of finite element analysis (FEA) for the composite structure and experimental data collected through structural and thermal testing are also presented.

42 ENGINEERING↗

The solar simulation test of the ITALSAT thermal structural model

The ITALSAT structural/thermal model (STM) was submitted to a solar simulation test in order to verify the spacecraft thermal design and the thermal mathematical model which will be used to predict the on orbit temperatures. The STM was representative of the flight model in terms of configuration, structures, appendages and thermal hardware; dissipating dummy units were used to simulate the electronic units. The test consisted of the main phases: on station (beginning of life), on station (end of life), and transfer orbit. Preliminary results indicate that the test performances were satisfactory. The spacecraft measured temperatures were up to 15 degrees higher than the predicted ones. This imposes a careful correlation analysis in order to have reliable flight temperature predictions.

Giommi, M.↗

Electrochromic Radiator Coupon Level Testing and Full Scale Thermal Math Modeling for Use on Altair Lunar Lander

In order to control system and component temperatures, many spacecraft thermal control systems use a radiator coupled with a pumped fluid loop to reject waste heat from the vehicle. Since heat loads and radiation environments can vary considerably according to mission phase, the thermal control system must be able to vary the heat rejection. The ability to "turn down" the heat rejected from the thermal control system is critically important when designing the system.. Electrochromic technology as a radiator coating is being investigated to vary the amount of heat being rejected by a radiator. Coupon level tests were performed to test the feasibility of the technology. Furthermore, thermal math models were developed to better understand the turndown ratios required by full scale radiator architectures to handle the various operation scenarios during a mission profile for Altair Lunar Lander. This paper summarizes results from coupon level tests as well as thermal math models developed to investigate how electrochromics can be used to provide the largest turn down ratio for a radiator. Data from the various design concepts of radiators and their architectures are outlined. Recommendations are made on which electrochromic radiator concept should be carried further for future thermal vacuum testing.

Sheth, Rubik↗

Lessons Learned from Recent Testing in the Nuclear Thermal Rocket Element Environmental Simulator

The Nuclear Thermal Rocket Element Environmental Simulator (NTREES) facility is designed to perform realistic non-nuclear testing of nuclear thermal rocket (NTR) fuel elements and fuel materials. Although the NTREES facility cannot reproduce the neutron and gamma environment of an operating NTR, it can simulate the thermal hydraulic environment within an NTR fuel element to provide critical information on material performance and compatibility. The NTREES facility is currently being reconfigured with an all new suite of pyrometers, a new coil and feedthrough design along with a new gas sampling system for the mass spectrometer. Also new is the ability to perform chamber purges using argon. All of these modifications are the result of experiences gained through several years of testing various NTR components under a wide range of operating conditions. The testing details and the lessons learned from those tests are discussed in this presentation.

Emrich, William J., Jr.↗

A review of test results on solar thermal power modules with dish-mounted Stirling and Brayton cycle engines

This paper presents results of development tests of various solar thermal parabolic dish modules and assemblies that used dish-mounted Brayton or Stirling cycle engines for production of electric power. These tests indicate that early modules achieve net efficiencies up to 29 percent in converting sunlight to electricity, as delivered to the grid. Various equipment deficiencies were observed and a number of malfunctions occurred. The performance measurements, as well as the malfunctions and other test experience, provided information that should be of value in developing systems with improved performance and reduced maintenance.

Jaffe, Leonard D.↗

Thermal Performance of Spandrel Assemblies in Glazed Wall Systems: Laboratory Test Design – Challenges and Test Results

Accurate thermal performance calculation procedures for opaque spandrel areas in curtain wall and window wall systems are essential for rating systems when comparing spandrel systems. However, there is a lack of consensus in thermal modeling needed for accurately characterizing heat transfer through spandrel assemblies due to the complex arrangement of materials and structural components. Several studies indicate that conventional 2D thermal simulations may overestimate R-values by 30% compared to physical testing and 3D simulations. Detailed simulations and well-curated laboratory test data are necessary to build confidence in simulation models, which will later be used to develop correlations to improve widely used conventional 2D thermal simulations. This study aims to experimentally test heat transfer through various spandrel assemblies to validate 3D simulation models. Also, the challenges of conducting a thorough testing design along with the solutions would be documented. The team developed a design for testing spandrel assemblies, making appropriate modifications to the existing heat, air, and moisture (HAM) chamber to accommodate the testing needs. Two moveable baffles were designed and fabricated to guide airflow direction parallel to the test article surface. The data acquisition capabilities in the chamber were upgraded to add more than two hundred sensors to the climate and indoor side of the chamber. The goal is to provide a quality dataset for validating complex 3D modeling simulations, which will be used to develop improved thermal simulation techniques that more accurately represent the thermal behavior of spandrel assemblies and their integration within the building envelope. This paper will summarize the results for the boundary conditions of the testing and the temperature variation across different locations of the spandrel assemblies.

Kunwar, Niraj [ORNL] (ORCID:0000000263457652)↗

Evaluation of Select Heat and Pressure Measurement Gauges for Potential Use in the NRC/OECD High Energy Arc Fault (HEAF) Test Program

In an effort to improve the current state of the art in fire probabilistic risk assessment methodology, the U.S. Nuclear Regulatory Commission, Office of Regulatory Research, contracted Sandia National Laboratories (SNL) to conduct a series of scoping tests to identify thermal and mechanical probes that could be used to characterize the zone of influence (ZOI) during high energy arc fault (HEAF) testing. For the thermal evaluation, passive and active probes were exposed to HEAF-like heat fluxes for a period of 2 seconds at the SNL's National Solar Thermal Test Facility to determine their ability to survive and measure such an extreme environment. Thermal probes tested included temperature lacquers (passive), NANMAC thermocouples, directional flame thermometers, modified plate thermometers, infrared temperature sensors, and a Gardon heat flux gauge. Similarly, passive and active pressure probes were evaluated by exposing them to pressures resulting from various high-explosive detonations at the Sandia Terminal Ballistic Facility. Pressure probes included bikini pressure gauges (passive) and pressure transducers. Results from these tests provided good insight to determine which probes should be considered for use during future HEAF testing.

47 OTHER INSTRUMENTATION↗

Electrochromic Radiator Coupon Level Testing and Full Scale Thermal Math Modeling for Use on Altair Lunar Lander

In order to control system and component temperatures, many spacecraft thermal control systems use a radiator coupled with a pumped fluid loop to reject waste heat from the vehicle. Since heat loads and radiation environments can vary considerably according to mission phase, the thermal control system must be able to vary the heat rejection. The ability to "turn down" the heat rejected from the thermal control system is critically important when designing the system. Electrochromic technology as a radiator coating is being investigated to vary the amount of heat rejected by a radiator. Coupon level tests were performed to test the feasibility of this technology. Furthermore, thermal math models were developed to better understand the turndown ratios required by full scale radiator architectures to handle the various operation scenarios encountered during a mission profile for the Altair Lunar Lander. This paper summarizes results from coupon level tests as well as the thermal math models developed to investigate how electrochromics can be used to increase turn down ratios for a radiator. Data from the various design concepts of radiators and their architectures are outlined. Recommendations are made on which electrochromic radiator concept should be carried further for future thermal vacuum testing.

Bannon, Erika T.↗

The Structural Heat Intercept-Insulation-Vibration Evaluation Rig (SHIVER)

NASA is currently investigating methods to reduce the boil-off rate on large cryogenic upper stages. Two such methods to reduce the total heat load on existing upper stages are vapor cooling of the cryogenic tank support structure and integration of thick multilayer insulation systems to the upper stage of a launch vehicle. Previous efforts have flown a 2-layer MLI blanket and shown an improved thermal performance, and other efforts have ground-tested blankets up to 70 layers thick on tanks with diameters between 2 3 meters. However, thick multilayer insulation installation and testing in both thermal and structural modes has not been completed on a large scale tank. Similarly, multiple vapor cooled shields are common place on science payload helium dewars; however, minimal effort has gone into intercepting heat on large structural surfaces associated with rocket stages. A majority of the vapor cooling effort focuses on metallic cylinders called skirts, which are the most common structural components for launch vehicles. In order to provide test data for comparison with analytical models, a representative test tank is currently being designed to include skirt structural systems with integral vapor cooling. The tank is 4 m in diameter and 6.8 m tall to contain 5000 kg of liquid hydrogen. A multilayer insulation system will be designed to insulate the tank and structure while being installed in a representative manner that can be extended to tanks up to 10 meters in diameter. In order to prove that the insulation system and vapor cooling attachment methods are structurally sound, acoustic testing will also be performed on the system. The test tank with insulation and vapor cooled shield installed will be tested thermally in the B2 test facility at NASAs Plumbrook Station both before and after being vibration tested at Plumbrooks Space Power Facility.

Cryogenic Fluid Management↗

Considerations in STS payload environmental verification

Considerations regarding the Space Transportation System (STS) payload environmental verification are reviewed. It is noted that emphasis is placed on testing at the subassembly level and that the basic objective of structural dynamic payload verification is to ensure reliability in a cost-effective manner. Structural analyses consist of: (1) stress analysis for critical loading conditions, (2) model analysis for launch and orbital configurations, (3) flight loads analysis, (4) test simulation analysis to verify models, (5) kinematic analysis of deployment/retraction sequences, and (6) structural-thermal-optical program analysis. In addition to these approaches, payload verification programs are being developed in the thermal-vacuum area. These include the exposure to extreme temperatures, temperature cycling, thermal-balance testing and thermal-vacuum testing.

Keegan, W. B.↗

Turbine blade and vane heat flux sensor development, phase 1

Heat flux sensors available for installation in the hot section airfoils of advanced aircraft gas turbine engines were developed. Two heat flux sensors were designed, fabricated, calibrated, and tested. Measurement techniques are compared in an atmospheric pressure combustor rig test. Sensors, embedded thermocouple and the Gordon gauge, were fabricated that met the geometric and fabricability requirements and could withstand the hot section environmental conditions. Calibration data indicate that these sensors yielded repeatable results and have the potential to meet the accuracy goal of measuring local heat flux to within 5%. Thermal cycle tests and thermal soak tests indicated that the sensors are capable of surviving extended periods of exposure to the environment conditions in the turbine. Problems in calibration of the sensors caused by severe non-one dimensional heat flow were encountered. Modifications to the calibration techniques are needed to minimize this problem and proof testing of the sensors in an engine is needed to verify the designs.

Atkinson, W. H.↗

Thermal Conductivity Estimation from Transient Test Data with Embedded Thermocouples using Genetic Algorithm Optimization

Inverse heat transfer methodology previously developed to estimate thermal properties of high temperature fibrous insulation from embedded thermocouples was applied to the thermoplastic polymer, polyether-ether-ketone (PEEK). A small experimental setup was utilized to test the PEEK sample between temperatures of 300 K and 525 K at atmospheric pressure. Cylindrical plugs of PEEK with three thermocouples embedded at various depths were incorporated in the test sample. The experimental PEEK thermocouple data were used as the boundary and initial conditions of a one-dimensional numerical thermal model to predict the internal temperatures of the material. The thermal conductivity of PEEK was estimated with the Continuous Genetic Algorithm optimization technique by searching for the coefficients of a functional form of thermal conductivity that minimized the difference between the experimentally measured and model predicted internal temperature values. The thermal testing, one-dimensional numerical thermal model, optimization algorithm, analysis, and results are presented.

Thermal Properties↗

Acoustic testing of high temperature panels

Results are presented of a series of thermal-acoustic tests conducted on the NASA Langley Research Center Thermal-Acoustic Test Apparatus to (1) investigate techniques for obtaining strain measurements on metallic and carbon-carbon materials at elevated temperature; (2) document the dynamic strain response characteristics of several superalloy honeycomb thermal protection system panels at elevated temperatures of up to 1200 F; and (3) determine the strain response and sonic fatigue behavior of four carbon-carbon panels at both ambient and elevated temperatures. A second study tested four carbon-carbon panels to document panel dynamic response characteristics at ambient and elevated temperature, determine time to failure and faliure modes, and collect continuous strain data up to panel failure. Strain data are presented from both types of panels, and problems encountered in obtaining reliable strain data on the carbon-carbon panels are described. The failure modes of the carbon-carbon panels are examined.

Leatherwood, Jack D.↗