Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “target setting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

MO-FG-CAMPUS-TeP1-04: Pseudo-In-Vivo Dose Verification of a New Mono-Isocentric Technique for the Treatment of Multiple Brain Metastases

Purpose: To validate dose calculation and delivery accuracy of a recently introduced mono-isocentric technique for the treatment of multiple brain metastases in a realistic clinical case. Methods: Anonymized CT scans of a patient were used to model a hollow phantom that duplicates anatomy of the skull. A 3D printer was used to construct the phantom of a radiologically bone-equivalent material. The hollow phantom was subsequently filled with a polymer gel 3D dosimeter which also acted as a water-equivalent material. Irradiation plan consisted of 5 targets and was identical to the one delivered to the specific patient except for the prescription dose which was optimized to match the gel dose-response characteristics. Dose delivery was performed using a single setup isocenter dynamic conformal arcs technique. Gel dose read-out was carried out by a 1.5 T MRI scanner. All steps of the corresponding patient’s treatment protocol were strictly followed providing an end-to-end quality assurance test. Pseudo-in-vivo measured 3D dose distribution and calculated one were compared in terms of spatial agreement, dose profiles, 3D gamma indices (5%/2mm, 20% dose threshold), DVHs and DVH metrics. Results: MR-identified polymerized areas and calculated high dose regions were found to agree within 1.5 mm for all targets, taking into account all sources of spatial uncertainties involved (i.e., set-up errors, MR-related geometric distortions and registration inaccuracies). Good dosimetric agreement was observed in the vast majority of the examined profiles. 3D gamma index passing rate reached 91%. DVH and corresponding metrics comparison resulted in a satisfying agreement between measured and calculated datasets within targets and selected organs-at-risk. Conclusion: A novel, pseudo-in-vivo QA test was implemented to validate spatial and dosimetric accuracy in treatment of multiple metastases. End-to-end testing demonstrated that our gel dosimetry phantom is suited for such QA procedures, allowing for 3D analysis of both targeting placement and dose.

60 APPLIED LIFE SCIENCES↗

Study of Robustness of IMPT and IMRT for Prostate Cancer Against Organ Movement

Purpose: Intensity-modulated radiotherapy with photons (IMRT) and protons (IMPT) produces dose distributions that have high conformality to the planning target volume and sufficient sparing of the organs at risk if calculated on a single static computed tomography (CT) scan. For prostate cancer patients, organ movement with related changes to the density distribution in the irradiated volume occurs during the treatment course. We evaluated the sensitivity of IMPT and IMRT plans to organ movement. Methods and Materials: IMPT and IMRT treatment plans were evaluated for 4 patients with an average of 16 CT data sets per patient. The treatment plans were recalculated on all treatment CT scans, and the dose was accumulated in the reference geometry using a deformable registration algorithm. Accurate dose calculation methods were applied for both IMPT and IMRT. Results: With IMPT, unacceptably low total doses in the gross tumor volume were observed for patients with gas in the rectum on the planning CT scan. To achieve a total equivalent uniform dose (EUD) and EUD spread similar to that with IMRT, two methods were crucial for IMPT-a rectal gas water-equivalent density overwrite in the original planning CT scan and initial beam weight setting to achieve a homogeneous dose distribution for the whole planning target volume for each field separately. An improvement in the total EUD for the prostate and rectal wall was also observed for IMRT with the water-equivalent density overwrite of the rectal cavities. Conclusion: The sensitivities of IMPT and IMRT to organ movement are of the same order if appropriate planning strategies are applied. The latter is especially crucial for IMPT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Search for anomalous fragments produced in collisions with heavy target nuclei and in delta Z = 1 peripheral interactions

We exposed a stack of CR39 track detectors containing Ag foils to a 1.7-GeV/nucleon 56Fe beam and investigated the anomalous mean-free-path effect. Neither the whole set of 7517 nor a subset of 2542 interacting fragments produced probably in the Ag target show an effect. By combining the data of this and an earlier experiment we can also exclude an effect for 3219 interacting fragments produced in delta Z = 1 collisions.

Polyethylene Glycols↗

SU-F-P-31: Dosimetric Effects of Roll and Pitch Corrections Using Robotic Table

Purpose: To quantify the dosimetric effect of roll and pitch corrections being performed by two types of robotic tables available at our institution: BrainLabTM 5DOF robotic table installed at VERO (BrainLab&MHI) dedicated SBRT linear accelerator and 6DOF robotic couch by IBA Proton Therapy with QFixTM couch top. Methods: Planning study used a thorax phantom (CIRSTM), scanned at 4DCT protocol; targets (IGTV, PTV) were determined according to the institutional lung site-specific standards. 12 CT sets were generated with Pitch and Roll angles ranging from −4 to +4 degrees each. 2 table tops were placed onto the scans according to the modality-specific patient treatment workflows. The pitched/rolled CT sets were fused to the original CT scan and the verification treatment plans were generated (12 photon SBRT plans and 12 proton conventional fractionation lung plans). Then the CT sets were fused again to simulate the effect of patient roll/pitch corrections by the robotic table. DVH sets were evaluated for all cases. Results: The effect of not correcting the phantom position for roll/pitch in photon SBRT cases was reducing the target coverage by 2% as maximum; correcting the positional errors by robotic table varied the target coverage within 0.7%. in case of proton treatment, not correcting the phantom position led to the coverage loss up to 4%, applying the corrections using robotic table reduced the coverage variation to less than 2% for PTV and within 1% for IGTV. Conclusion: correcting the patient position by using robotic tables is highly preferable, despite the small dosimetric changes introduced by the devices.

60 APPLIED LIFE SCIENCES↗

Wind farm structural response and wake dynamics for an evolving stable boundary layer: computational and experimental comparisons

Abstract. The wind turbine design process requires performing thousands of simulations for a wide range of inflow and control conditions, which necessitates computationally efficient yet time-accurate models, especially when considering wind farm settings. To this end, FAST.Farm is a dynamic-wake-meandering-based mid-fidelity engineering tool developed by the National Renewable Energy Laboratory targeted at accurately and efficiently predicting wind turbine power production and structural loading in wind farm settings, including wake interactions between turbines. This work is an extension of a study that addressed constructing a diurnal cycle evolution based on experimental data (Quon, 2024). Here, this inflow is used to validate the turbine structural and wake-meandering response between experimental data, FAST.Farm simulation results, and high-fidelity large-eddy simulation results from the coupled Simulator fOr Wind Farm Applications (SOWFA)–OpenFAST tool. The validation occurs within the nocturnal stable boundary layer when corresponding meteorological and turbine data are available. To this end, we compared the load results from FAST.Farm and SOWFA–OpenFAST to multi-turbine measurements from a subset of a full-scale wind farm. Computational predictions of blade-root and tower-base bending loads are compared to 10 min statistics of strain gauge measurements during 3.5 h of the evolving stable boundary layer, generally with good agreement. This time period coincided with an active wake-steering campaign of an upstream turbine, resulting in time-varying yaw positions of all turbines. Wake meandering was also compared between the computational solutions, generally with excellent agreement. Simulations were based on a high-fidelity precursor constructed from inflow measurements and using state-of-the-art mesoscale-to-microscale coupling.

17 WIND ENERGY↗

Accurate Cross-section Calculations for Low-Energy Electron-Atom Collisions

We describe a recently developed fully relativistic B-spline R-matrix method for atomic structure as well as calculations for electron and photon collision with atoms and ions. The method is based on the solution of the many-electron Fock-Dirac equation and allows to employ non-orthogonal sets of atomic orbitals. A B-spline basis is used to generate both the target description and the R-matrix basis functions in the inner region. Employing B-splines of different orders for the large and small components prevents the appearance of spurious states in the spectrum of the Dirac equation. Using term-dependent and thus nonorthogonal sets of one-electron functions enables us to generate accurate and flexible representations of the target states and the scattering function. Our method is based upon the Dirac-Coulomb Hamiltonian and thus may be employed for any complex atom or ion, without the use of phenomenological core potentials. Example results from recent applications of the method for accurate calculations of low-energy electron scattering from noble gases are presented. In most cases we obtained a substantial improvement over results obtained in previous Breit-Pauli R-matrix calculations.

74 ATOMIC AND MOLECULAR PHYSICS↗

Sci—Fri AM: Mountain — 06: Optimizing planning target volume in lung radiotherapy using deformable registration

A four dimensional computed tomography (4DCT) image is acquired for all radically treated, lung cancer patients to define the internal target volume (ITV), which encompasses tumour motion due to breathing and subclinical disease. Patient set-up error and anatomical motion that is not due to breathing is addressed through an additional 1 cm margin around the ITV to obtain the planning target volume (PTV). The objective of this retrospective study is to find the minimum PTV margin that provides an acceptable probability of delivering the prescribed dose to the ITV. Acquisition of a kV cone beam computed tomography (CBCT) image at each fraction was used to shift the treatment couch to accurately align the spinal cord and carina. Our method utilized deformable image registration to automatically position the planning ITV on each CBCT. We evaluated the percentage of the ITV surface that fell within various PTVs for 79 fractions across 18 patients. Treatment success was defined as a situation where at least 99% of the ITV is covered by the PTV. Overall, this is to be achieved in at least 90% of the treatment fractions. The current approach with a 1cm PTV margin was successful ∼96% of the time. This analysis revealed that the current margin can be reduced to 0.8cm isotropic or 0.6×0.6×1 cm{sup 3} non-isotropic, which were successful 92 and 91 percent of the time respectively. Moreover, we have shown that these margins maintain accuracy, despite intrafractional variation, and maximize CBCT image guidance capabilities.

60 APPLIED LIFE SCIENCES↗

International Review of the Development and Implementation of Energy Efficiency Standards and Labeling Programs

Appliance energy efficiency standards and labeling (S&L) programs have been important policy tools for regulating the efficiency of energy-using products for over 40 years and continue to expand in terms of geographic and product coverage. The most common S&L programs include mandatory minimum energy performance standards (MEPS) that seek to push the market for efficient products, and energy information and endorsement labels that seek to pull the market. This study seeks to review and compare some of the earliest and most well-developed S&L programs in three countries and one region: the U.S. MEPS and ENERGY STAR, Australia MEPS and Energy Label, European Union MEPS and Ecodesign requirements and Energy Label and Japanese Top Runner programs. For each program, key elements of S&L programs are evaluated and comparative analyses across the programs undertaken to identify best practice examples of individual elements as well as cross-cutting factors for success and lessons learned in international S&L program development and implementation. The international review and comparative analysis identified several overarching themes and highlighted some common factors behind successful program elements. First, standard-setting and programmatic implementation can benefit significantly from a legal framework that stipulates a specific timeline or schedule for standard-setting and revision, product coverage and legal sanctions for non-compliance. Second, the different MEPS programs revealed similarities in targeting efficiency gains that are technically feasible and economically justified as the principle for choosing a standard level, in many cases at a level that no product on the current market could reach. Third, detailed survey data such as the U.S. Residential Energy Consumption Survey (RECS) and rigorous analyses provide a strong foundation for standard-setting while incorporating the participation of different groups of stakeholders further strengthen the process. Fourth, sufficient program resources for program implementation and evaluation are critical to the effectiveness of standards and labeling programs and cost-sharing between national and local governments can help ensure adequate resources and uniform implementation. Lastly, check-testing and punitive measures are important forms of enforcement while the cancellation of registration or product sales-based fines have also proven effective in reducing non-compliance. The international comparative analysis also revealed the differing degree to which the level of government decentralization has influenced S&L programs and while no single country has best practices in all elements of standards and labeling development and implementation, national examples of best practices for specific elements do exist. For example, the U.S. has exemplified the use of rigorous analyses for standard-setting and robust data source with the RECS database while Japan's Top Runner standard-setting principle has motivated manufacturers to exceed targets. In terms of standards implementation and enforcement, Australia has demonstrated success with enforcement given its long history of check-testing and enforcement initiatives while mandatory information-sharing between EU jurisdictions on compliance results is another important enforcement mechanism. These examples show that it is important to evaluate not only the drivers of different paths of standards and labeling development, but also the country-specific context for best practice examples in order to understand how and why certain elements of specific S&L programs have been effective.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Time Domain Simulations of Single Molecule Raman Scattering

Non-equilibrium chemical phenomena are known to play an important role in single molecule microscopy and spectroscopy. Herein, we explore these effects through ab initio molecular dynamics (AIMD)-based Raman spectral simulations. We target an isolated aromatic thiol (thiobenzonitrile, TBN) as a prototypical molecular system. We first show that the essential features contained in the ensemble-averaged Raman spectrum of TBN can be reproduced by averaging over 18 short AIMD trajectories spanning a total simulation time of ~60 ps. This involved more than 90,000 polarizability calculations at the B3LYP/def2-TZVP level of theory. We then illustrate that the short trajectories (~3.3 ps total simulation time), where the accessible phase space is not fully sampled, provide a basis set for understanding key features that are often observed in measurements targeting single molecules. Our results suggest that a complete understanding of single molecule Raman scattering needs to account for molecular conformational flexibility and non-equilibrium chemical phenomena. These effects are well-captured using the described AIMD-based single molecule Raman spectral simulations.

Apra, Edoardo↗

New short-time alignment technique for 70-meter antenna surface panels

With severely limited field modification time for upgrading the 64-m antenna to 70-m diameter, a new shorter time method for aligning the surface panels of the main reflector was needed. For each target on the surface panel, both distance (or range) and elevation angle measurements are made. A new technique for setting the surface panels at zenith look has been devised. This article describes the software required to convert the computed target distortions obtained from the JPL-IDEAS structural analysis computer program (defining the gravity load change from a 45-deg elevation angle to zenith look) into the theodolite reading at zenith look. The technique results in a perfectly shaped reflector at the 45-deg rigging elevation, with acceptable surface error tolerance.

Katow, M. S.↗

The Influenza A Virus Endoribonuclease PA-X Usurps Host mRNA Processing Machinery to Limit Host Gene Expression

Often, many viruses shut off host gene expression to inhibit antiviral responses. Viral proteins and host proteins required for viral replication are typically spared in this process, yet the mechanisms of target selectivity during host shutoff remain poorly understood. Using transcriptome-wide and targeted reporter experiments, we demonstrate that the influenza A virus endoribonuclease PA-X usurps RNA splicing to selectively target host RNAs for destruction. Proximity-labeling proteomics reveals that PA-X interacts with cellular RNA processing proteins, some of which are partially required for host shutoff. Thus, PA-X taps into host nuclear pre-mRNA processing mechanisms to destroy nascent mRNAs shortly after their synthesis. This mechanism sets PA-X apart from other viral host shutoff proteins that target actively translating mRNAs in the cytoplasm. Our study reveals a unique mechanism of host shutoff that helps us understand how influenza viruses suppress host gene expression.

59 BASIC BIOLOGICAL SCIENCES↗

Effects of Interfractional Motion and Anatomic Changes on Proton Therapy Dose Distribution in Lung Cancer

Purpose: Proton doses are sensitive to intra- and interfractional anatomic changes. We analyzed the effects of interfractional anatomic changes in doses to lung tumors treated with proton therapy. Methods and Materials: Weekly four-dimensional computed tomography (4D-CT) scans were acquired for 8 patients with mobile Stage III non-small cell lung cancer who were actually treated with intensity-modulated photon radiotherapy. A conformal proton therapy passive scattering plan was designed for each patient. Dose distributions were recalculated at end-inspiration and end-expiration breathing phases on each weekly 4D-CT data set using the same plans with alignment based on bone registration. Results: Clinical target volume (CTV) coverage was compromised (from 99% to 90.9%) in 1 patient because of anatomic changes and motion pattern variation. For the rest of the patients, the mean CTV coverage on the repeated weekly 4D-CT data sets was 98.4%, compared with 99% for the original plans. For all 8 patients, however, a mean 4% increase in the volume of the contralateral lung receiving a dose of at least 5 Gy (V5) and a mean 4.4-Gy increase in the spinal cord maximum dose was observed in the repeated 4D-CT data sets. A strong correlation between the CTV density change resulting from tumor shrinkage or anatomic variations and mean contralateral lung dose was observed. Conclusions: Adaptive re-planning during proton therapy may be indicated in selected patients with non-small cell lung cancer. For most patients, however, CTV coverage is adequate if tumor motion is taken into consideration in the original simulation and planning processes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

First low-frequency Einstein@Home all-sky search for continuous gravitational waves in Advanced LIGO data

We report results of a deep all-sky search for periodic gravitational waves from isolated neutron stars in data from the first Advanced LIGO observing run. This search investigates the low frequency range of Advanced LIGO data, between 20 and 100 Hz, much of which was not explored in initial LIGO. The search was made possible by the computing power provided by the volunteers of the Einstein@Home project. We find no significant signal candidate and set the most stringent upper limits to date on the amplitude of gravitational wave signals from the target population, corresponding to a sensitivity depth of 48.7 [1/$\sqrt{Hz}$]. At the frequency of best strain sensitivity, near 100 Hz, we set 90% confidence upper limits of 1.8×10 ₋25 . At the low end of our frequency range, 20 Hz, we achieve upper limits of 3.9×10 ₋24 . At 55 Hz we can exclude sources with ellipticities greater than 10 ₋5 within 100 pc of Earth with fiducial value of the principal moment of inertia of 10 38 kg m 2 .

79 ASTRONOMY AND ASTROPHYSICS↗

Final Approach Navigation to Europa: Setting Up for a Successful Landing

Jupiter's moon Europa has been a prime target in the search for extraterrestrial life since the Galileo orbiter indicated that a saltwater ocean may exist beneath its icy crust. The proposed Europa Lander mission targets revolutionary science investigations on the surface of Europa with the main objective to search for evidence of life. Europa presents unique challenges to a landing mission because of its hostile radiation environment and the lack of information about its terrain. This paper provides an overview of Europa Lander Navigation-Deorbit, Descent, and Landing (DDL) technology development study, which is focused on the interface between ground navigation operations and onboard DDL behavior and the challenges associated with landing a probe on Europa.

McElrath, Tim↗

Detecting Unclassified Electromagnetic Signals for Secure Wireless Communication Using Open Set Recognition

We developed multiple machine learning methods for the detection and classification of new wireless communication waveforms, which is critical for targeted attacks in wireless networks and electronic warfare. Our machine learning models are capable of dynamically detecting security threats in near real time through our advanced open set recognition (OSR) approach. This model has demonstrated significant improvements in the detection of unknown waveforms, thereby enhancing the security and reliability of mission critical communications. Our approach to detecting uncertain security threats is novel; we advanced OSR techniques by incorporating domain knowledge of wireless signals. Specifically, we combined time and frequency domain model features to enhance the model’s performance. Utilizing an OSR approach eliminates the need for training data to be distributed similarly to the deployment environment and removes the requirement for the training set to contains all possible threat classes. This is crucial because it is often infeasible to determine and characterize all potential security threats in advance. Our model were trained on simulated data, generated in partnership with the University at Albany, State of New York. The data set contained a diverse array of wireless signals, including those with additive white Gaussian noise and multipath signals, with and without line of sight. This comprehensive training set allowed us to optimize our models to detect unknown waveforms under various challenging scenarios, such as low signal-to-noise ratios. By training on various waveforms, varying signal-to-noise ratio, and different sample sizes under normal conditions, our models were fine tuned to perform effectively in challenging environments.

99 - GENERAL AND MISCELLANEOUS↗

Dose Gradient Near Target-Normal Structure Interface for Nonisocentric CyberKnife and Isocentric Intensity-Modulated Body Radiotherapy for Prostate Cancer

Purpose: The treatment planning quality between nonisocentric CyberKnife (CK) and isocentric intensity modulation treatment was studied for hypofractionated prostate body radiotherapy. In particular, the dose gradient across the target and the critical structures such as the rectum and bladder was characterized. Methods and Materials: In the present study, patients treated with CK underwent repeat planning for nine fixed-field intensity-modulated radiotherapy (IMRT) using identical contour sets and dose-volume constraints. To calculate the dose falloff, the clinical target volume contours were expanded 30 mm anteriorly and posteriorly and 50 mm uniformly in other directions for all patients in the CK and IMRT plans. Results: We found that all the plans satisfied the dose-volume constraints, with the CK plans showing significantly better conformity than the IMRT plans at a relative greater dose inhomogeneity. The rectal and bladder volumes receiving a low dose were also lower for CK than for IMRT. The average conformity index, the ratio of the prescription isodose volume and clinical target volume, was 1.18 {+-} 0.08 for the CK plans vs. 1.44 {+-} 0.11 for the IMRT plans. The average homogeneity index, the ratio of the maximal dose and the prescribed dose to the clinical target volume, was 1.45 {+-} 0.12 for the CK plans vs. 1.28 {+-} 0.06 for the IMRT plans. The average percentage of dose falloff was 2.9% {+-} 0.8%/mm for CK and 3.1% {+-} 1.0%/mm for IMRT in the anterior direction, 3.8% {+-} 1.6%/mm for CK and 3.2% {+-} 1.9%/mm for IMRT in the posterior direction, and 3.6% {+-} 0.4% for CK and 3.6% {+-} 0.4% for IMRT in all directions. Conclusion: Nonisocentric CK was as capable of producing equivalent fast dose falloff as high-number fixed-field IMRT delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Digital Tomosynthesis for Respiratory Gated Liver Treatment: Clinical Feasibility for Daily Image Guidance

Purpose: Breath-hold (BH) treatment minimizes internal target volumes (ITV) when treating sites prone to motion. Digital tomosynthesis (DTS) imaging has advantages over cone-beam CT (CBCT) for BH imaging: BH-DTS scan can be completed during a single breath-hold, whereas BH-CBCT is usually acquired by parsing the gantry rotation into multiple BH segments. This study evaluates the localization accuracy of DTS for BH treatment of liver tumors. Methods: Both planning CT and on-board DTS/CBCT images were acquired under BH, using the planning CT BH window as reference. Onboard imaging data sets included two independent DTS orientations (coronal and sagittal), and CBCT images. Soft tissue target positioning was measured by each imaging modality and translated into couch shifts. Performance of the two DTS orientations was evaluated by comparing target positioning with the CBCT benchmark, determined by two observers. Results: Image data sets were collected from thirty-eight treatment fractions (14 patients). Mean differences between the two DTS methods and the CBCT method were <1 mm in all directions (except the lateral direction with sagittal-DTS: 1.2 mm); the standard deviation was in the range of 2.1-3.5 mm for all techniques. The Pearson correlation showed good interobserver agreement for the coronal-DTS (0.72-0.78). The interobserver agreement for the sagittal-DTS was good for the in-plane directions (0.70-0.82), but poor in the out-of-plane direction (lateral, 0.26). Conclusions: BH-DTS may be a simpler alternative to BH-CBCT for onboard soft tissue localization of the liver, although the precision of DTS localization appears to be somewhat lower because of the presence of subtle out-of-plane blur.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detection of ℓ = 4 and ℓ = 5 modes in 12 years of solar VIRGO-SPM data—tests on Kepler observations of 16 Cyg A and B

We present the detection of ℓ = 4 and ℓ = 5 modes in power spectra of the Sun, constructed from 12 yr full-disk VIRGO-SPM data sets. A method for enhancing the detectability of these modes in asteroseismic targets is presented and applied to Kepler data of the two solar analogues 16 Cyg A and B. For these targets, we see indications of a signal from ℓ = 4 modes, while nothing is yet seen for ℓ = 5 modes. We further simulate the power spectra of these stars and from this we estimate that it should indeed be possible to see such indications of ℓ = 4 modes at the present length of the data sets. In the simulation process, we briefly look into the apparent misfit between observed and calculated mode visibilities. We predict that firm detections of at least ℓ = 4 should be possible in any case at the end of the Kepler mission. For ℓ = 5, we do not predict any firm detections from Kepler data.

79 ASTRONOMY AND ASTROPHYSICS↗