Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tables”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Axial and reflection asymmetry of the nuclear ground state

More than a decade ago we published a calculation of nuclear ground-state masses and deformations in Atomic Data and Nuclear Data Tables [P. Moeller, J.R. Nix, W.D. Myers, W.J. Swiatecki, At. Data Nucl. Data Tables 59 (1995) 185]. In this study, triaxial nuclear shapes were not considered. We have now enhanced our model and studied the influence of triaxial shape degrees of freedom on the nuclear ground-state potential-energy (mass) and ground-state shape. It turns out that a few hundred nuclei are affected to a varying degree with the largest effect, about 0.7 MeV, occurring near {sup 108}Ru. We provide here a table of the calculated effects of triaxial shape degrees of freedom. Although axial-asymmetry effects were not considered in the 1995 mass calculation, it did study the effects of reflection-asymmetric shape degrees of freedom ({epsilon}{sub 3}) on nuclear masses. However, the magnitude of the effect was not tabulated. Here, we provide such a table. In addition we calculate the effect in a much improved fashion: we search a four-dimensional deformation space ({epsilon}{sub 2}, {epsilon}{sub 3}, {epsilon}{sub 4}, and {epsilon}{sub 6}). This is now possible because the computational resources available to us today are more than 100,000 times better than at the time we calculated the mass table published in 1995.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Use of Implanted Markers and Interportal Adjustment With Real-Time Tracking Radiotherapy System to Reduce Intrafraction Prostate Motion

Purpose: Interportal adjustment was applied to patients with prostate cancer using three fiducial markers and two sets of fluoroscopy in a real-time tumor-tracking radiotherapy (RTRT) system. The incidence of table position adjustment required to keep intrafractional uncertainty within 2.0 mm was investigated in this study. Methods and Materials: The coordinates of the center of gravity of the three fiducial markers were measured at the start of every portal irradiation in intensity-modulated radiotherapy (IMRT) with seven ports. The table position was adjusted to the planned position if the discrepancy was larger than 2.0 mm in the anterior-posterior (AP), cranial-caudal (CC), or left-right (LR) directions. In total, we analyzed 4,541 observations in 20 patients who received 70 Gy in 30 fractions (7.6 times a day on average). Results: The incidence of table position adjustment at 10 minutes from the initial setup of each treatment was 14.2%, 12.3%, and 5.0% of the observations in the AP, CC, and LR directions, respectively. The accumulated incidence of the table position adjustment was significantly higher at 10 minutes than at 2 minutes for AP (p = 0.0033) and CC (p = 0.0110) but not LR (p = 0.4296). An adjustment greater than 5 mm was required at least once in the treatment period in 11 (55%) patients. Conclusions: Interportal adjustment of table position was required in more than 10% of portal irradiations during the 10-minute period after initial setup to maintain treatment accuracy within 2.0 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Seasonal Controls of CO 2 and CH 4 Dynamics in a Temporarily Flooded Subtropical Wetland

Subtropical and tropical wetlands play a prominent role in the global carbon (C) cycle; yet factors that influence their C fluxes remain uncertain. We collected measurements from a temporarily flooded subtropical wetland over 3 years to investigate environmental drivers impacting CO 2 and CH 4 fluxes. The wetland was a sink of CO 2 (-469 to -380 g C-CO 2 · m -2 · year -1 ) and a source of CH 4 (25.1 to 32.1 g C-CH 4 · m -2 · year -1 ) to the atmosphere. Dry season CH 4 emissions represented 41 to 49% of the annual budget, reflecting the importance of continuous CH 4 flux measurements. Gross primary productivity (GPP) increased with temperature and radiation, and the influence of VPD on GPP varied with soil inundation. Higher water tables decreased Reco and increased GPP, and a higher GPP in turn lead to enhanced R eco likely through enhancements of GPP on autotrophic respiration. This suggests that the impact of the water table on R eco depends on the cancelling effects of hydrology and GPP. Emissions of CH 4 increased with soil temperature, water table, and GPP until soils were inundated at which point temperature and GPP became the main drivers. Water table and temperature influenced GPP and CH 4 fluxes, and increases in GPP directly enhanced CH 4 emissions. In addition to impacting C fluxes directly through water table depth, hydrology also determined the hierarchy of the dominance of factors controlling C fluxes and their response. The positive climate forcing of subtropical wetlands may be dictated by plant-mediated and climate interactions, with hydrological factors playing a major role in determining the greenhouse gas sink or source strength of subtropical wetlands.

54 ENVIRONMENTAL SCIENCES↗

Author Correction: Genome-guided isolation of the hyperthermophilic aerobe Fervidibacter sacchari reveals conserved polysaccharide metabolism in the Armatimonadota

Correction to: Nature Communicationshttps://doi.org/10.1038/s41467-024-53784-3, published online 4 November 2024 In the version of this article initially published, Table 1 did not include the properties of the taxa being proposed or refer directly to another location in the main manuscript describing the properties. As such, the original manuscript did not comply with Rule 27 (2)(c) of the ICNP. Also, Table 1 listed the order Fervidibacterales as the nomenclatural type for the class Fervidibacteria, which violates latest emended version of Rule 15 stating that the nomenclatural type for a class must be a genus. Below we provide a modification of Table 1 containing protologues with these errors corrected. We have also changed the order of the taxa in the table to meet the most common ordering. (Table presented.) Taxon names proposed under the ICNP Proposed taxon Etymology Description Genus Fervidibacter Fer.vi.di.bac’ter. L. masc. adj. fervidus, hot, steaming; N.L. masc. n. bacter, a rod; N.L. masc. n. Fervidibacter, a hot rod Thermophilic or hyperthermophilic inhabitants of freshwater thermal environments. All members are likely polysaccharide-degrading chemoheterotrophs with numerous carbohydrate-active enzymes encoded in their genomes. Aerobic, with high-affinity and/or low-affinity terminal oxidases present in the genomes. The oxidative pentose phosphate pathway and the tricarboxylic acid cycle are complete in genomes belonging to the genus. Gram-stain-negative and diderm cell envelope structure. Ovoid- to rod-shaped morphology. Spores are not formed. The genus is a distinct phylogenetic lineage in the family Fervidibacteraceae, the order Fervidibacterales, and the class Fervidibacteria in the phylum Armatimonadota. The type species is Fervidibacter sacchariT. Species Fervidibacter sacchari sac’cha.ri. N.L. gen. n. sacchari, of sugar Hyperthermophilic, microaerophilic, facultatively anaerobic, and grows chemoheterotrophically on monosaccharides and polysaccharides. Cells are ovoid- to rod-shaped, Gram-stain negative, and are 0.9–1.3 µm in width and 1.6–3.6 µm in length. Grows between 65 and 87.5 °C and an optimum temperature of 80 °C, and a pH range of 6.5–8.6 with an optimum pH of 7.5. Grows at an optimum O2 concentration of 5–10%. Grows on D-arabinose, D-galactose, D-glucose, D-rhamnose, D-ribose, D-xylose, chondroitin sulfate, colloidal chitin, galactan, gellan gum, guar gum, karaya gum, locust bean gum, xantham gum, xyloglucan, β-glucan, glycogen, starch, AFEX-pretreated corn stover, miscanthus, sugarcane bagasse, acetate and casamino acids. Grows weakly on xyloglucan under fermentation conditions. The major fatty acids (>10%) are C16:0, C18:0 and/or cyclo-C17:0, and iso-C16:0. The major respiratory quinones (>10%) are MK-8 and MK-9. The isolate and genomes of the species have been recovered from geothermal springs in the Great Basin, Nevada, USA. GC content of genomes range between 51–52%. Subunits for both the high-affinity and low-affinity terminal oxidases are encoded in the genomes. Genomes also encode a Group 3d [NiFe] hydrogenase, which produces hydrogen as an electron sink for NAD+ regeneration. The type strain PD1T (= JCM 39283T = DSM 113467T) was isolated from Great Boiling Spring in Nevada, USA. Family Fervidibacteraceae Fer.vi.di.bac.te.ra’ce.ae. N.L. masc. n. Fervidibacter type genus of the family; L. suff. -aceae ending to denote a family; N.L. fem. pl. n. Fervidibacteraceae the family of the genus Fervidibacter Thermophilic or hyperthermophilic inhabitants of freshwater thermal environments. All members are likely polysaccharide-degrading chemoheterotrophs with numerous carbohydrate-active enzymes encoded in their genomes. Aerobic, with high-affinity and/or low-affinity terminal oxidases present in the genomes. The oxidative pentose phosphate pathway and the tricarboxylic acid cycle are complete in genomes belonging to the family. The family is a distinct phylogenetic lineage in the order Fervidibacterales and the class Fervidibacteria in the phylum Armatimonadota. The type genus is Fervidibacter. Order Fervidibacterales Fer.vi.di.bac.te.ra’les. N.L. masc. n. Fervidibacter type genus of the order; L. suff. -ales ending to denote an order; N.L. fem. pl. n. Fervidibacterales the order of the genus Fervidibacter Thermophilic or hyperthermophilic inhabitants of freshwater thermal environments. All members are likely polysaccharide-degrading chemoheterotrophs with numerous carbohydrate-active enzymes encoded in their genomes. Aerobic or strictly anaerobic. Phylogenomic placement of this lineage within the Fervidibacteria and relative evolutionary divergence supports delineation of this lineage as an order within the class Fervidibacteria and phylum Armatimonadota. The type genus is Fervidibacter. Class Fervidibacteria Fer.vi.di.bac.te’ri.a. N.L. masc. n. Fervidibacter type genus of the type order of the class; L. suff. -ia ending to denote a class; N.L. neut. pl. n. Fervidibacteria the class of the order Fervidibacterales Thermophilic or hyperthermophilic inhabitants of freshwater thermal environments. All members are likely polysaccharide-degrading chemoheterotrophs with numerous carbohydrate-active enzymes encoded in their genomes. Aerobic or strictly anaerobic. Phylogenomic placement of this lineage within the Armatimonadota and relative evolutionary divergence supports delineation of this lineage as a class within the Armatimonadota. The type genus is Fervidibacter. The error has not been corrected in the PDF or HTML versions of the Article.

Nou, Nancy O↗

Belowground plant allocation regulates rice methane emissions from degraded peat soils

Carbon-rich peat soils have been drained and used extensively for agriculture throughout human history, leading to significant losses of their soil carbon. One solution for rewetting degraded peat is wet crop cultivation. Crops such as rice, which can grow in water-saturated conditions, could enable agricultural production to be maintained whilst reducing CO 2 and N 2 O emissions from peat. However, wet rice cultivation can release considerable methane (CH 4 ). Water table and soil management strategies may enhance rice yield and minimize CH 4 emissions, but they also influence plant biomass allocation strategies. It remains unclear how water and soil management influences rice allocation strategies and how changing plant allocation and associated traits, particularly belowground, influence CH 4 -related processes. We examined belowground biomass (BGB), aboveground biomass (AGB), belowground:aboveground ratio (BGB:ABG), and a range of root traits (root length, root diameter, root volume, root area, and specific root length) under different soil and water treatments; and evaluated plant trait linkages to CH 4 . Rice (Oryza sativa L.) was grown for six months in field mesocosms under high (saturated) or low water table treatments, and in either degraded peat soil or degraded peat covered with mineral soil. We found that BGB and BGB:AGB were lowest in water saturated conditions where mineral soil had been added to the peat, and highest in low-water table peat soils. Furthermore, CH 4 and BGB were positively related, with BGB explaining 60% of the variation in CH 4 but only under low water table conditions. Our results suggest that a mix of low water table and mineral soil addition could minimize belowground plant allocation in rice, which could further lower CH 4 likely because root-derived carbon is a key substrate for methanogenesis. Minimizing root allocation, in conjunction with water and soil management, could be explored as a strategy for lowering CH 4 emissions from wet rice cultivation in degraded peatlands.

54 ENVIRONMENTAL SCIENCES↗

Nuclear Magnetic Dipole and Electric Quadrupole Moments: Their Measurement and Tabulation as Accessible Data

The most recent tabulations of nuclear magnetic dipole and electric quadrupole moments have been prepared and published by the Nuclear Data Section of the IAEA, Vienna [N. J. Stone, Report No. INDC(NDS)-0650 (2013); Report No. INDC(NDS)-0658 (2014)]. The first of these is a table of recommended quadrupole moments for all isotopes in which all experimental results are made consistent with a limited number of adopted standards for each element; the second is a combined listing of all measurements of both moments. Both tables cover all isotopes and energy levels. In this paper, the considerations relevant to the preparation of both tables are described, together with observations as to the importance and (where appropriate) application of necessary corrections to achieve the “best” values. Some discussion of experimental methods is included with emphasis on their precision. The aim of the published quadrupole moment table is to provide a standard reference in which the value given for each moment is the best available and for which full provenance is given. A table of recommended magnetic dipole moments is in preparation, with the same objective in view.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Erratum: “Beyond chemical accuracy in the heavy p-block: The first ionization potentials and electron affinities of Ga–Kr, In–Xe, and Tl–Rn” [J. Chem. Phys. 151, 024303 (2019)]

In Ref. 1 incorrect values for the spin-orbit effects on the electron affinities (EAs) of Ga and In were used in Table IV. The KRCI values shown in Table III of Ref. 1, -0.49 and -0.94 kcal/mol for Ga and In, respectively, should have been given. Correct use of these latter values results in final FPD EAs for Ga and In of 6.97 and 8.91 kcal/mol, respectively. The incorrect FPD values were also given in the Abstract and Conclusion sections of Ref. 1. In addition, the experimental EA for In shown in the last column of Table IV was incorrect and should be 8.85 kcal/mol (the actual value being 8.8534 but only two decimal places are displayed throughout this table). A complete replacement for Table IV is given below with the corrected values given in bold font. The corrected FPD and experimental EA values for In in particular changes some of the conclusions of Ref. 1, namely when it is stated both in the abstract and the main text (Sec. III.B and Conclusions) that the experimental EA values for all of the group 13 (Ga, In, and Tl) EAs are too large. This is obviously not true for the EA of In, where the actual FPD value and the experimental result of Walter et al. are in excellent agreement, to within 0.1 kcal/mol. The FPD EAs of the other two group 13 elements, Ga and Tl, differ from their experimental values by 2.5 and 1.3 kcal/mol, respectively, which is still outside of the estimated uncertainty limits of this FPD approach (conservatively ±0.5 kcal/mol), particularly for Ga, therefore the original conclusions for these two elements are largely unchanged.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

NEW HYPERON EQUATIONS OF STATE FOR SUPERNOVAE AND NEUTRON STARS IN DENSITY-DEPENDENT HADRON FIELD THEORY

We develop new hyperon equation of state (EoS) tables for core-collapse supernova simulations and neutron stars. These EoS tables are based on a density-dependent relativistic hadron field theory where baryon-baryon interaction is mediated by mesons, using the parameter set DD2 for nucleons. Furthermore, light and heavy nuclei along with interacting nucleons are treated in the nuclear statistical equilibrium model of Hempel and Schaffner-Bielich which includes excluded volume effects. Of all possible hyperons, we consider only the contribution of Λs. We have developed two variants of hyperonic EoS tables: in the npΛφ case the repulsive hyperon-hyperon interaction mediated by the strange φ meson is taken into account, and in the npΛ case it is not. The EoS tables for the two cases encompass a wide range of densities (10{sup –12} to ∼1 fm{sup –3}), temperatures (0.1 to 158.48 MeV), and proton fractions (0.01 to 0.60). The effects of Λ hyperons on thermodynamic quantities such as free energy per baryon, pressure, or entropy per baryon are investigated and found to be significant at higher densities. The cold, β-equilibrated EoS (with the crust included self-consistently) results in a 2.1 M {sub ☉} maximum mass neutron star for the npΛφ case, whereas that for the npΛ case is 1.95 M {sub ☉}. The npΛφ EoS represents the first supernova EoS table involving hyperons that is directly compatible with the recently measured 2 M {sub ☉} neutron stars.

79 ASTRONOMY AND ASTROPHYSICS↗

Review of Particle Physics

The Review summarizes much of particle physics and cosmology. Using data from previous editions, plus 3,324 new measurements from 878 papers, we list, evaluate, and average measured properties of gauge bosons and the recently discovered Higgs boson, leptons, quarks, mesons, and baryons. We summarize searches for hypothetical particles such as supersymmetric particles, heavy bosons, axions, dark photons, etc. Particle properties and search limits are listed in Summary Tables. We give numerous tables, figures, formulae, and reviews of topics such as Higgs Boson Physics, Supersymmetry, Grand Unified Theories, Neutrino Mixing, Dark Energy, Dark Matter, Cosmology, Particle Detectors, Colliders, Probability and Statistics. Among the 120 reviews are many that are new or heavily revised, including a new review on High Energy Soft QCD and Diffraction and one on the Determination of CKM Angles from B Hadrons. The Review is divided into two volumes. Volume 1 includes the Summary Tables and 98 review articles. Volume 2 consists of the Particle Listings and contains also 22 reviews that address specific aspects of the data presented in the Listings. The complete Review (both volumes) is published online on the website of the Particle Data Group (pdg.lbl.gov) and in a journal. Volume 1 is available in print as the PDG Book. A Pariicle Physics Booklet with the Summary Tables and essential tables, figures, and equations from selected review articles is available in print and as a web version optimized for use on phones as well as an Android app.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Review of Particle Physics

Abstract The Review summarizes much of particle physics and cosmology. Using data from previous editions, plus 2,143 new measurements from 709 papers, we list, evaluate, and average measured properties of gauge bosons and the recently discovered Higgs boson, leptons, quarks, mesons, and baryons. We summarize searches for hypothetical particles such as supersymmetric particles, heavy bosons, axions, dark photons, etc. Particle properties and search limits are listed in Summary Tables. We give numerous tables, figures, formulae, and reviews of topics such as Higgs Boson Physics, Supersymmetry, Grand Unified Theories, Neutrino Mixing, Dark Energy, Dark Matter, Cosmology, Particle Detectors, Colliders, Probability and Statistics. Among the 120 reviews are many that are new or heavily revised, including a new review on Machine Learning, and one on Spectroscopy of Light Meson Resonances. The Review is divided into two volumes. Volume 1 includes the Summary Tables and 97 review articles. Volume 2 consists of the Particle Listings and contains also 23 reviews that address specific aspects of the data presented in the Listings. The complete Review (both volumes) is published online on the website of the Particle Data Group (pdg.lbl.gov) and in a journal. Volume 1 is available in print as the PDG Book. A Particle Physics Booklet with the Summary Tables and essential tables, figures, and equations from selected review articles is available in print, as a web version optimized for use on phones, and as an Android app.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pretest Modeling A Spent Nuclear Fuel Seismic Shake Test

The U.S. Department of Energy Spent Fuel and Waste Science and Technology (SFWST) program is planning to conduct a series of full-scale shake table tests to simulate hypothetical earthquake conditions and record the response of surrogate spent nuclear fuel (SNF) assemblies in a dry canister storage system mockup. The shake table motions will represent a range of hypothetical earthquake conditions at hypothetical locations in the continental U.S. to generally define the range of mechanical loads that SNF can be expected to experience during extended dry storage periods. This paper describes the pretest predictions made with LS-DYNA models of the mockup storage systems. The test will use two dry storage system configurations, a mockup vertical concrete cask (VCC) and a mockup horizontal storage module (HSM). The test will use a production-quality canister and basket. Within the canister will be four instrumented fuel assemblies with fuel rods containing surrogate mass and 28 instrumented dummy assemblies that are intended to match the mass and outer dimension of a fuel assembly. The finite element models include models of the VCC and HSM on the shake table to calculate the system level dynamic responses and separate single fuel assembly models to calculate stress and strain in fuel assembly components. Both types of models include nonlinear behavior like rod-to-rod contact and the ability for VCC’s to rock and slide. This paper presents the expected response of the VCC, HSM, and fuel assemblies to the shake table testing that is planned to start in April of 2024. The earthquake conditions represent seismic hazards in the 2,000-to-20,000-year return period range. The test data is expected to confirm the expectation that fuel rod cladding will remain intact, fuel assembly structural components like guide tubes will remain intact, and no significant VCC sliding or tipping will occur in the range of conditions to be tested with the shake table.

Klymyshyn, Nicholas A.↗

SU-E-T-754: Three-Dimensional Patient Modeling Using Photogrammetry for Collision Avoidance

Purpose: To evaluate photogrammetry for creating a three-dimensional patient model. Methods: A mannequin was configured on the couch of a CT scanner to simulate a patient setup using an indexed positioning device. A CT fiducial was placed on the indexed CT table-overlay at the reference index position. Two dimensional photogrammetry targets were placed on the table in known positions. A digital SLR camera was used to obtain 27 images from different positions around the CT table. The images were imported into a commercial photogrammetry package and a 3D model constructed. Each photogrammetry target was identified on 2 to 5 images. The CT DICOM metadata and the position of the CT fiducial were used to calculate the coordinates of the photogrammetry targets in the CT image frame of reference. The coordinates were transferred to the photogrammetry software to orient the 3D model. The mannequin setup was transferred to the treatment couch of a linear accelerator and positioned at isocenter using in-room lasers. The treatment couch coordinates were noted and compared with prediction. The collision free regions were measured over the full range of gantry and table motion and were compared with predictions obtained using a general purpose polygon interference algorithm. Results: The reconstructed 3D model consisted of 180000 triangles. The difference between the predicted and measured couch positions were 5 mm, 1 mm, and 1 mm for longitudinal, lateral, and vertical, respectively. The collision prediction tested 64620 gantry table combinations in 11.1 seconds. The accuracy was 96.5%, with false positive and negative results occurring at the boundaries of the collision space. Conclusion: Photogrammetry can be used as a tool for collision avoidance during treatment planning. The results indicate that a buffer zone is necessary to avoid false negatives at the boundary of the collision-free zone. Testing with human patients is underway. Research partially supported by a grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

SU-F-I-72: Evaluation of the Ancillary Lead Shielding for Optimizing Radiation Protection in the Interventional Radiology Department

Purpose: The rising complexity of interventional fluoroscopic procedures has resulted in an increase of occupational radiation exposures in the interventional radiology (IR) department. This study assessed the impact of ancillary shielding on optimizing radiation protection for the IR staff. Methods: Scattered radiation measurements were performed in two IR suites equipped with Axiom Artis systems (Siemens Healthcare, Erlangen, Germany) installed in 2006 and 2010. Both rooms had suspended ceiling-mounted lead-acrylic shields of 75×60 cm (Mavig, Munich, Germany) with lead equivalency of 0.5 mm, and under-table drapes of 70×116 cm and 65×70 cm in the newer and the older room respectively. The larger skirt can be wrapped around the table’s corner and in addition the newer suite had two upper shields of 25×55 cm and 25×35 cm. The patient was simulated by 30 cm of acrylic, air kerma rate (AKR) was measured with the 180cc ionization chamber (AccuPro Radcal Corporation, Monrovia, CA, USA) at different positions. The ancillary shields, x-ray tube, image detector, and table height were adjusted by the IR radiologist to simulate various clinical setups. The same exposure parameters were used for all acquisitions. AKR measurements were made at different positions relative to the operator. Results: The AKR measurements demonstrated 91–99% x-ray attenuation by the drapes in both suites. The smaller size of the under-table skirt and absence of the side-drapes in the older room resulted in a 20–50 fold increase of scattered radiation to the operator. The mobile suspended lead-acrylic shield reduced AKR by 90–94% measured at 150–170 cm height. The recommendations were made to replace the smaller under-table skirt and to use the ceiling-mounted shields for all IR procedures. Conclusion: The ancillary shielding may significantly affect radiation exposure to the IR staff. The use of suspended ceiling-mounted shields is especially important for reduction of interventional radiologists’ cranial radiation.

60 APPLIED LIFE SCIENCES↗

Utah FORGE: Geochemical Data for Cold Groundwaters and Produced Geothermal Fluids

Geochemical data for cold groundwaters and produced geothermal fluids around the Utah FORGE site. The data is compiled into four tables in the attached Excel File. Table 1 is a compilation of compositions (anions, cations, weak acids, oxygen, hydrogen, and carbon isotopes) for cold groundwaters and produced geothermal waters in the Milford valley, Utah. Table 2 is a compilation of noble gas (He, Ne, Ar) and He and Ne isotopic compositions for cold groundwaters and produced geothermal waters in the Milford valley, Utah. Table 3 provides values for calculated advective and diffusive fluxes of helium. Table 4 provides values of calculated subsurface stored heat between the Opal Mound fault and the Utah FORGE site, which are related to volumes of recently solidified magmatic heat sources.

15 GEOTHERMAL ENERGY↗

DOE EV Data Collection - Vehicle Data

Vehicle data consist of electric vehicle performance data collected directly from the vehicle during standard operations. Data were collected using onboard data loggers that were either installed by the project team or preinstalled by the original equipment manufacturer. Data recorded by the data loggers were made accessible via an online web portal or an application programming interface. Different data loggers were used (HEM, ViriCiti, and Geotab), and the method for each vehicle is defined in the vehicle attributes file. Some systems collected data on a “trip-level” basis, in which each row of a table represents a single trip (the period between a key-on and key-off event), whereas other data were collected on a per-day basis, in which each row represents a single day of operation. Data were collected over a range of data collection periods, depending on the project. Data have been anonymized by removing information or decreasing information resolution as necessary so that fleets are not identifiable. Due to the wide range of vehicle types represented and variation in data collection, data parameters and frequencies differ between vehicles and fleets The **Performance Data Daily/Trip Data Dictionaries** contain definitions for each available parameter associated with a vehicle’s operations, aggregated at either a daily or trip level. The parameters available will vary from vehicle to vehicle, but every possible parameter will be defined. The **Vehicle Attributes Data Dictionary** contains definitions for each available parameter associated with a vehicle’s physical and functional attributes and fleet context. The **Vehicle Attributes** table contains specific vehicle characteristics, coded to an anonymous Vehicle ID. This Vehicle ID can be used as a key between vehicle data and vehicle attribute tables. The **Vehicle Data** tables contain the data from each vehicle’s operations, aggregated at either a daily or trip level, coded to an anonymous Vehicle ID. This Vehicle ID can be used as a key between vehicle data and vehicle attribute tables. Data is being uploaded quarterly through 2023 and subject to change until the conclusion of the project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Historic climate, cosmogenic 10Be, denudation-rate, and geospatial datasets from the Pikes Peak region, Colorado, USA

This data package contains geographic information system (GIS) layers and tabular datasets associated with the study of elevation-dependent denudation rates on Pikes Peak in the Front Range of the Rocky Mountains, Colorado, USA. The package includes GIS layers used to produce the study-area map, including sample locations, sample watershed boundaries, the Pikes Peak batholith, Pleistocene glacier extent, weather station locations, and elevation and hillshade rasters, together with comma-separated value (CSV) tables and matching CSV data dictionaries. These mapped layers provide the geographic framework for interpreting denudation patterns across the Pikes Peak region and for relating sample locations to watershed geometry, bedrock setting, glacial history, and nearby climate stations. The first group of tables reports climate and geospatial context for the study area. These files include station-based temperature and precipitation data used to characterize elevational gradients in mean annual climate and monthly climate seasonality, sample locations, denudation-rate and topographic metrics, fixed frost-cracking model parameters, frost-cracking intensity and precipitation-frequency metrics, and stream-power inversion results. Together, these data provide the basis for evaluating how denudation varies with elevation, climate, and landscape form across sampled catchments on Pikes Peak. The second group of tables reports cosmogenic nuclide and erosion-model results used in the denudation analysis. Included files contain accelerator mass spectrometry (AMS) measurements for in situ-produced cosmogenic beryllium-10 (10Be), including sample identifiers, measured 10Be:9Be ratios, analytical uncertainties, carrier mass, quartz mass, blank corrections, blank-group statistics, and calculated 10Be concentrations and uncertainties. Additional tables summarize stream-power-law inversion results for sampled catchments, including optimized model parameters, predicted erosion rates, residual metrics, channel-pixel counts, and convergence status, as well as regression equations and summary statistics used to evaluate relationships among elevation, climate, frost cracking, precipitation forcing, and denudation rate. The package contains GIS files, comma-separated value files (.csv), Microsoft Excel files (.xlsx), CSV data dictionaries, a file-level metadata table, and a readme text file.

10Be cosmogenic nuclides↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electron beam loss assumptions for ELI-NPMEGa-ray radioprotection analysis

The ELI-NP project is now working on the design of their conventional facility. Dr. Gheorghe Cata-Danil recently requested that I provide them with information on the location and amount of electron-beam loss in the MEGa-ray source they have proposed for ELI-NP. This memo is intended to document that information, for transmission to ELI-NP. The ELI-NP MEGa-ray source, as presently proposed, consists of two x-band accelerator sections separated by a large chicane, as show in figure 1. The basic parameters of the machine that are pertinent for specifying the radiation source terms are shown in table 1. These are the parameters of the intentionally-produced photobeam. In addition to the photobeam, the electron gun and accelerator will produce 'dark current' that originates throughout the RF structures (that is, distributed along the accelerator axis) and therefore has a distribution of energy below the energy of the photobeam. Because it is emitted from surfaces inside the RF structures, much of it is not transported through the accelerator and is lost in the accelerator RF structures. A large fraction of the total dark current is produced in the photogun and lost at the entrance of the 1st accelerator RF structure. Important sources of radiation during operation are beam alignment screens that are used for observing the image of the electron beam, during adjustment of beam steering and for general diagnostic purposes. Each screen consists of a 1 mm thick Ce:YAG plate that is moved into the path of the beam when desired. This destroys the electron beam, spraying all beam current into the structures downstream of the screen. Only one screen is inserted at a time. These screens may be located after each accelerator RF structure, and after each set of bend magnets, as shown in figure 3. The photobeam energy and currents at each location are listed in table 2; for simplicity, the dark current energy is (conservatively) assumed to be the same as the photobeam energy. In normal operation, the locations of other beam losses and the estimated current and energy of the lost beam are listed in table 3. In addition to these 'normal' beam losses, it is assumed that the beam may be accidentally mis-steered by up to 1 degree at every steering magnet, so that it hits the surrounding beam tube and other structures. This loss can be modeled as occurring at the locations listed in table 2, numbers 1-7 and 16-21. Similarly, it is assumed that any of the dipole magnets, in chicanes or at the beam dump, may fail, resulting in total beam loss straight ahead. These locations can be assumed to be the same as listed in table 2, numbers 8-10, 12-14, 22-24, 26, and 27. The data provided above are estimates of the beam loss, for the purpose of calculating radiation source terms. Dark current estimates are conservative, until we acquire actual operational data. Neither the estimated currents nor the estimated energies listed above contain any intentional margin. when they have performed similar calculations for their own purposes, they have typically added approximately 10% to the beam energy to provide some overall margin in the analysis.

42 ENGINEERING↗