Effect of pressure on high-temperature oxidation of Ni alloys in supercritical CO 2 containing impurities
Direct supercritical CO 2 (sCO 2 ) power cycles require structural materials compatible with hot sCO 2 containing high levels of water and oxygen impurities. Chromia-forming Ni-based superalloys, which are leading candidates at temperatures > 600 °C, have shown good compatibility in pure sCO 2 , however potential impurity effects are not well understood. In this report we exposed several commercial Ni-based alloys to 95%CO 2 -4%H 2 O-(1-3)%O 2 at 750 °C and 0.1 or 20 MPa for 2500 h. Protective chromia scales formed in all cases. Nevertheless, water vapor-assisted oxide volatilization clearly occurred at high pressure. The volatilization rates decreased with time, but still represent a potentially serious compatibility issue in real, high-velocity, sCO 2 systems.