Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectrometry data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Measurements of the mass and isotopic yields of the {sup 233}U(n{sub th},f) reaction at the Lohengrin spectrometer

Over the last 10 years, a vast campaign of measurements has been initiated to improve the precision of neutron data for the involved key nuclei ({sup 232}Th, {sup 233}Pa and {sup 233}U) of the innovative Th -{sup 233}U cycle. This latter might indeed provide cleaner nuclear energy than the present U-Pu one. New measurements of charge and mass distributions of the fission products have been achieved at the Lohengrin spectrometer of the Inst. Laue-Langevin (ILL) during fall 2010 to complete the experimental data of {sup 233}U(n,f) that exist mainly for light fission fragments. That is why we performed measurements of mass and isotopic yields with a special focus on the heavy fission fragment part. Mass yields were measured by ion counting with an ionization chamber after separation by the Lohengrin spectrometer. Isotopic yields were derived from gamma spectrometry of mass-separated beams using HPGe clover detectors. This paper will present the results of these fission yield measurements along with details on the experimental set-up and the chosen analysis method. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of the Ultimate One-Dimensional Time to Explosion (UODTX) Apparatus

With recent advancements in experimental capabilities and worldwide improvement of digital data acquisition and control, there is sufficient justification to develop a new version of the One Dimensional Time to eXplosion (ODTX) system to allow for additional diagnostics and improved control to increase sample throughput and increase the adaptability of future experiments. The legacy ODTX system was designed to measure time to explosion (TTX) for a given temperature, which it does well, but it was not equipped to handle the recent experimental advances of Pressure-ODTX (PODTX) and Composition-ODTX (CODTX). PODTX involves fielding a pressure transducer as an additional diagnostic and applying arbitrary heating-profiles to the system anvils. CODTX furthers this concept by including in-situ gas-composition analysis via infrared (IR) absorption techniques with plans to extend CODTX to solid composition detection and in-situ mass spectrometry (MS). The legacy ODTX system was not built with these experiments in mind and performing them involves substantial modifications and downtime to the existing machine. Developing a standalone system that can perform all C/P/ODTX experiments and is adaptable to unconceived experiments would allow for the continued use of ODTX as a work-horse for Small Scale Safety Testing (SSST), but also provide a testbed for new explosive safety research. This system would ultimately be housed in the neighboring ODTX cell and would live at the High Explosive Application Facility (HEAF) until the end of its service life. HEAF, Chemistry, and Engineering would be the primary stakeholders for the system’s design as they all have experiments that they want to perform. Engineering would be responsible for the system development and would work closely with HEAF to ensure that the system is built with high explosive (HE) safety in mind. By the end of development and after product realization, HEAF/Chemistry would be the system owner, operator, and primary user. The proposed system design is highly influenced by the existing ODTX design. The system will have load frame to support the experiment, anvils to confine the explosive, and some means of applying confining pressure. The samples will be able to be heated and cooled through the confining the anvils. The biggest change from the legacy design is the ability to add diagnostics to the experiment as needed: thermocouples (TCs), resistance temperature detectors (RTDs), pressure transducers (PTs), infrared transmittance/absorbance (IR), mass spectrometry (MS), strain gages (SGs), photonic doppler velocimeter (PDV), as well as arbitrary 4-20 mV signals and +/- 10 VDC signals. The current design does not allow for flexibility in that respect and is hardwired with a few diagnostic channels. The onus will fall on designing a load frame that can support system modifications as well as a data acquisition system that can handle the multitude of signal types.

36 MATERIALS SCIENCE↗

Heavy Ion Deep-Inelastic Collisions Studied By Discrete Gamma-Ray Spectroscopy

The distributions of products of {sup 208}Pb+350 MeV {sup 64}Ni, {sup 130}Te+275 MeV {sup 64}Ni and {sup 208}Pb+345 MeV {sup 58}Ni collisions have been determined in thick target gamma-ray coincidence experiments. Analysis of gamma cross-coincidence data allowed to account for neutron evaporation to reconstruct primary product distributions. For the three studied systems the neutron-to-proton ratio equilibration as a function of the mass transfer have been obtained from the experimental data and compared to a simple Liquid Drop energy minimization.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Top-Down Characterization of the Post-Translationally Modified Intact Periplasmic Proteome from the Bacterium Novosphingobium aromaticivorans

The periplasm of Gram-negative bacteria is a dynamic and physiologically important subcellular compartment where the constant exposure to potential environmental insults amplifies the need for proper protein folding and modifications. Top-down proteomics analysis of the periplasmic fraction at the intact protein level provides unrestricted characterization and annotation of the periplasmic proteome, including the post-translational modifications (PTMs) on these proteins. Here, we used single-dimension ultra-high pressure liquid chromatography coupled with the Fourier transform mass spectrometry (FTMS) to investigate the intact periplasmic proteome of Novosphingobium aromaticivorans . Our top-down analysis provided the confident identification of 55 proteins in the periplasm and characterized their PTMs including signal peptide removal, N-terminal methionine excision, acetylation, glutathionylation, pyroglutamate, and disulfide bond formation. This study provides the first experimental evidence for the expression and periplasmic localization of many hypothetical and uncharacterized proteins and the first unrestrictive, large-scale data on PTMs in the bacterial periplasm.

Wu, Si↗

Evaluating the performance of two neutron spectrum unfolding codes based on iterative procedures and artificial neural networks

In this work the performance of two neutron spectrum unfolding codes based on iterative procedures and artificial neural networks is evaluated. The first one code based on traditional iterative procedures and called Neutron spectrometry and dosimetry from the Universidad Autonoma de Zacatecas (NSDUAZ) use the SPUNIT iterative algorithm and was designed to unfold neutron spectrum and calculate 15 dosimetric quantities and 7 IAEA survey meters. The main feature of this code is the automated selection of the initial guess spectrum trough a compendium of neutron spectrum compiled by the IAEA. The second one code known as Neutron spectrometry and dosimetry with artificial neural networks (NDSann) is a code designed using neural nets technology. The artificial intelligence approach of neural net does not solve mathematical equations. By using the knowledge stored at synaptic weights on a neural net properly trained, the code is capable to unfold neutron spectrum and to simultaneously calculate 15 dosimetric quantities, needing as entrance data, only the rate counts measured with a Bonner spheres system. Similarities of both NSDUAZ and NSDann codes are: they follow the same easy and intuitive user's philosophy and were designed in a graphical interface under the LabVIEW programming environment. Both codes unfold the neutron spectrum expressed in 60 energy bins, calculate 15 dosimetric quantities and generate a full report in HTML format. Differences of these codes are: NSDUAZ code was designed using classical iterative approaches and needs an initial guess spectrum in order to initiate the iterative procedure. In NSDUAZ, a programming routine was designed to calculate 7 IAEA instrument survey meters using the fluence-dose conversion coefficients. NSDann code use artificial neural networks for solving the ill-conditioned equation system of neutron spectrometry problem through synaptic weights of a properly trained neural network. Contrary to iterative procedures, in neural net approach it is possible to reduce the rate counts used to unfold the neutron spectrum. To evaluate these codes a computer tool called Neutron Spectrometry and dosimetry computer tool was designed. The results obtained with this package are showed. The codes here mentioned are freely available upon request to the authors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhanced Spatial Proteomics and Metabolomics from a Single Tissue Section Using MALDI-MSI and LCM-microPOTS Platforms

Spatially resolved mass spectrometry (MS)-based multi-omics workflows are becoming more utilized for revealing the complex biology that occurs within tissues. However, these approaches commonly require multiple independent tissue sections to analyze the metabolite and protein compositions of these samples. This poses a significant challenge in preserving cell- or region-specific molecular fidelity, as variations between tissue sections can compromise the accurate correlation of molecular data. Here, in this study, we developed workflows for comprehensive multi-omics profiling from a single tissue section (STS) using different MS modalities. We enhanced the functionality of an electrically insulated substrate by employing metal-assisted approaches that enabled both MS-based untargeted spatial metabolomics and proteomics from STS. This allowed metabolite imaging using matrix-assisted laser desorption/ionization-MS imaging (MALDI-MSI), without compromising it for subsequent proteome profiling with laser capture microdissection (LCM)-based technology. Specifically, implementing copper tape as a backing for polyethylene naphthalate (PEN) slides enabled the detection of >140 metabolites across a poplar root tissue section using MALDI-trapped ion mobility spectrometry time of flight (timsTOF)-MS. Afterwards, we detected 6,571 unique proteins from two distinct root regions by leveraging LCM technology coupled to our microdroplet based sample preparation approach. We also developed an alternative workflow utilizing gold-coated PEN substrates for imaging with MALDI-Fourier-transform ion cyclotron resonance (FTICR)-MS, which permitted the profiling of >170 metabolites and the identification of 6,542 unique proteins across a single poplar root tissue section. These results were comparable to using each assay independently without modifications. These approaches offer new opportunities for high-resolution molecular profiling of multiple omics-levels across biological tissues.

Veličković, Marija [Pacific Northwest National Lab↗

Storage Conditions of Human Kidney Tissue Sections Affect Spatial Lipidomics Analysis Reproducibility

Lipids often are labile, unstable, and tend to degrade overtime, so it is of the upmost importance to study these molecules in their most native state. In this study, we sought to understand the optimal storage conditions for spatial lipidomic analysis of human kidney tissue sections. Specifically, we evaluated human kidney tissue sections on several different days throughout the span of a week using our established protocol for elucidating lipids using high mass resolution matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI). We studied kidney tissue sections stored under five different conditions: open stored at –80 °C, vacuumed sealed and stored at –80 °C, with matrix preapplied before storage at –80 °C, under a nitrogen atmosphere and stored at –80 °C, and at room temperature in a desiccator. Results were compared to data obtained from kidney tissue sections that were prepared and analyzed immediately after cryosectioning. Data was processed using METASPACE. After a week of storage, the sections stored at room temperature showed the largest amount of lipid degradation, while sections stored under nitrogen and at –80 °C retained the greatest number of overlapping annotations in relation to freshly cut tissue. Overall, we found that molecular degradation of the tissue sections was unavoidable over time, regardless of storage conditions, but storing tissue sections in an inert gas at low temperatures can curtail molecular degradation within tissue sections.

60 APPLIED LIFE SCIENCES↗

Structural Study of Analogues of Titan’s Haze by Trapped Ion Mobility Coupled with a Fourier Transform Ion Cyclotron Mass Spectrometer

The aerosols present in the atmosphere of the Saturn’s moon Titan are of particular planetary science interest and several spacecraft missions are already allowed to gather spectroscopic data. Titan haze’s analogs, so-called tholins, were produced on earth to push forward the comprehension of their formation and properties. In this study, this highly complex mixture was analyzed here for the first time by trapped ion mobility spectrometry coupled to ultra-high resolution mass spectrometry (FTICR MS). Electrospray ionization revealed the characteristic CHN{sub x}-class components, with CHN{sub 5–6} and DBE 6–7 most abundant. Deploying specialized visualization, enabled by accurate mass measurements and elemental composition assignments, the adapted Kendrick mass defect analysis highlights the C{sub 2}H{sub 3}N homolog series, whereas the nitrogen-modified van Krevelen diagram exhibits a clear trend towards H/C 1.5 and N/C 0.5. More interestingly, the representation of m/z versus collision cross section (CCS) allowed hypothesizing a ramified N-PAH structural motif. State-of-the-art IMS is currently not able to resolve the isomeric continuum of ultra-complex mixtures; thus, peak parameters other than the CCS value are explored. As such, analyzing the mobility peak width versus m/z shows a linear increase in isomeric diversity between m/z 170 and 350 and a near plateau in diversity at higher m/z for the N-PAH-like structure. Due to the high complexity of the sample, these structural insights are only to be revealed by TIMS-FTICR MS. .

79 ASTRONOMY AND ASTROPHYSICS↗

Validation of Monte Carlo simulation of neutron production in a spallation experiment

A renewed interest in experimental research on Accelerator-Driven Systems (ADS) has been initiated by the global attempt to produce energy from thorium as a safe(r), clean(er) and (more) proliferation-resistant alternative to the uranium-fuelled thermal nuclear reactors. The ADS research has been actively pursued at the Joint Institute for Nuclear Research (JINR), Dubna, since decades. Most recently, the emission of fast neutrons was experimentally investigated at the massive (m = 512 kg) natural uranium spallation target QUINTA. The target has been irradiated with the relativistic deuteron beams of energy from 0.5 AGeV up to 4 AGeV at the JINR Nuclotron accelerator in numerous experiments since 2011. Neutron production inside the target was studied through the gamma-ray spectrometry measurement of natural uranium activation detectors. Experimental reaction rates for (n,γ), (n,f) and (n,2n) reactions in uranium have provided valuable information about the neutron distribution over a wide range of energies up to some GeV. The experimental data were compared to the predictions of Monte Carlo simulations using the MCNPX 2.7.0 code. In conclusion, the results are presented and potential sources of partial disagreement are discussed later in this work.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

No 182 W excess in the Ontong Java Plateau source

We report that small-scale W isotope variations in ancient and modern terrestrial rocks provide insights into Earth's accretion and early differentiation history as well as the long-term evolution of the Earth's mantle. Tungsten isotope studies on such rocks have exploited advances in mass spectrometry, both NTIMS and MC-ICPMS, which now permit the determination of W isotope ratios at unprecedented precision. While W isotope studies performed in different labs by MC-ICPMS and NTIMS generally exhibit excellent agreement, obtaining accurate W isotope data at this level of precision remains analytically challenging. For example, a recent NTIMS study reported a relatively large, +24 ppm excess in 182 W/ 184 W for a Phanerozoic sample from the Ontong Java Plateau (OJP), but no such 182 W/ 184 W anomaly was found in another study by MC-ICPMS. The present study aims to resolve the discrepancy between these two previous studies, and more generally to evaluate the agreement between different recent W isotope studies by NTIMS and MC-ICPMS. To this end, we report new W isotope data for OJP drill core samples obtained by MC-ICPMS. Additionally, the OJP samples analyzed here exhibit no resolvable 182 W/ 184 W excess relative to the standards and most terrestrial rocks. Moreover, the OJP samples as well as the terrestrial rock standards analyzed here exhibit small but variable W isotope variations for ratios involving 183 W, producing coupled variations in both ‘radiogenic’ (i.e., 182 W/ 183 W) and ‘non-radiogenic’ (i.e., 183 W/ 184 W) ratios. These W isotope variations are analytical in origin, induced during sample preparation, and very likely caused by a nuclear field shift isotope fractionation affecting primarily the odd isotope ( 183 W). The recently reported 182 W excess for an OJP sample may result from this nuclear field shift effect, as the NTIMS analyses had to rely on a double normalization involving the 183 W/ 184 W ratio. More generally, these results demonstrate that using 183 W data from any MC-ICPMS or NTIMS study requires a careful quantification of any potential analytical 183 W effect. Nevertheless, once such effects are taken into account, then both 182 W/ 184 W and 183 W/ 184 W can accurately be determined to a very high level of precision.

07 ISOTOPE AND RADIATION SOURCES↗

An Introduction to the Benchmarking and Publications for Non-Targeted Analysis Working Group

Non-targeted analysis (NTA) encompasses a rapidly evolving set of mass spectrometry techniques aimed at characterizing the chemical composition of complex samples, identifying unknown compounds, and/or classifying samples, without prior knowledge regarding the chemical content of the samples. Recent advances in NTA are the result of improved and more accessible instrumentation for data generation, and analysis tools for data evaluation and interpretation. As researchers continue to develop NTA approaches in various scientific fields, there is a growing need to identify, disseminate, and adopt community-wide method reporting guidelines. In 2018, NTA researchers formed the Benchmarking and Publications for Non-Targeted Analysis Working Group (BP4NTA) to address this need. Consisting of participants from around the world and representing fields ranging from environmental science and food chemistry to ‘omics and toxicology, BP4NTA provides resources addressing a variety of challenges associated with NTA. Furthermore, thus far, BP4NTA group members have aimed to establish consensus on NTA-related terms and concepts, and to create consistency in reporting practices by providing resources on a public website, including consensus definitions, reference content, and lists of available tools. Moving forward, BP4NTA will provide a setting for NTA researchers to continue discussing emerging challenges and contribute to additional harmonization efforts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dramatic Conformer-Dependent Reactivity of the Acetaldehyde Oxide Criegee Intermediate with Dimethylamine Via a 1,2-Insertion Mechanism

The reactivity of carbonyl oxides has previously been shown to exhibit strong conformer and substituent dependencies. Through a combination of synchrotron multiplexed photoionization mass spectrometry experiments (298 K, 4 Torr) and high-level theory (CCSD(T)-F12/cc-pVTZ-F12//B2PLYP-D3/cc-pVTZ with an added CCSDT(Q) correction), we explore the conformer dependence of the reaction of acetaldehyde oxide (CH 3 CHOO) with dimethyl amine (DMA). The experimental data supports the theoretically predicted 1,2-insertion mechanism and the formation of an amine-functionalized hydroperoxide reaction product. Tunable-VUV photoionization probing of anti- or anti- + syn-CH 3 CHOO reveals a strong conformer dependence of the title reaction. Here, the rate coefficient of DMA with anti-CH 3 CHOO is predicted to exceed that for the reaction with syn-CH 3 CHOO by a factor of ~34,000, which is attributed to submerged barrier (syn) vs. barrierless (anti) mechanisms for energetically downhill reactions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An approach toward quantification of organic compounds in complex environmental samples using high-resolution electrospray ionization mass spectrometry

Quantitative analysis of individual compounds in complex mixtures using high-resolution electrospray ionization mass spectrometry (HR-ESI-MS) is complicated by differences in the ionization efficiencies of analyte molecules in the mixture, resulting in signal suppression during ionization. However, the ability to obtain concentration estimates of compounds in an environmental sample is important for data interpretation and comparison. We introduce an approach for estimating mass concentrations of analytes observed in a multicomponent mixture by HR-ESI-MS, without prior separation. The approach relies on a calibration of the instrument using appropriate standards added to the mixture of studied analytes. An illustration of how the proposed calibration can be applied in practice is provided for aqueous extracts of isoprene photooxidation organic aerosol, with multifunctional organic acids standards. We show that the observed ion sensitivities in ESI-MS are positively correlated with the “adjusted mass,” defined as a product of the molecular mass and the H/C ratio in the molecule (adjusted mass = H/C x molecular mass). The correlation of the observed ESI sensitivity with adjusted mass is justified by considering trends of the physical and chemical properties of organic compounds that affect ionization in the positive ion mode, i.e., gas-phase basicity, polarizability, and molecular size.

Environmental Molecular Sciences Laboratory↗

Q Value of {sup 115}In->{sup 115}Sn(3/2{sup +}): The Lowest Known Energy beta Decay

Using precision, cryogenic, Penning-trap mass spectrometry we have measured the atomic mass difference M[{sup 115}In]-M[{sup 115}Sn] to be 497.489(10) keV/c{sup 2}. Combined with the energy of the 3/2{sup +} first excited state of {sup 115}Sn[J. Blachot, Nuclear Data Sheets 104, 967 (2005)], the Q value of the {sup 115}In(9/2{sup +})->{sup 115}Sn(3/2{sup +}) beta decay is determined to be 155(24) eV. This confirms the inference of Cattadori et al.[Nucl. Phys. A 748, 333 (2005)] that this small branching-ratio beta decay has the lowest-known Q value. We also report improved values of the individual atomic masses: M[{sup 115}In]=114.903 878 774(16) u and M[{sup 115}Sn]=114.903 344 697(17) u.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Novel Method to Investigate Stoichiometry and Performance of Buried Passivated Contacts Utilizing Time-of-Flight SIMS

We report on methods using time-of-flight secondary-ion mass spectrometry (TOF-SIMS) to elucidate critical information about the buried interfaces in interdigitated back-contact silicon solar cells. We examined the stoichiometry of the tunneling oxide with TOF-SIMS and X-ray photoelectron spectroscopy (XPS). Interestingly, the data indicates that the stoichiometry of the tunneling oxide moves away from SiO 2 towards lower stoichiometry (SiO x ) upon the crystallization annealing treatment, and towards SiO 2 again upon Al 2 O 3 deposition and a subsequent forming gas anneal. We also report on an important artifact for samples with an Al 2 O 3 passivation layer related to the oxygen content of the matrix.

14 SOLAR ENERGY↗

Bridging New Observational Capabilities and Process-Level Simulation: Insights into Aerosol Roles in the Earth System

The spatial distribution of ambient aerosol particles significantly impacts aerosol–radiation–cloud interactions, which contribute to the largest uncertainty in global anthropogenic radiative forcing estimations. However, the atmospheric boundary layer and lower free troposphere have not been adequately sampled in terms of spatiotemporal resolution, hindering a comprehensive characterization of various atmospheric processes and impeding our understanding of the Earth system. To address this research data gap, we have leveraged the development of uncrewed aerial systems (UAS) and advanced measurement techniques to obtain mesoscale spatial data on aerosol microphysical and optical properties around the U.S. Southern Great Plains (SGP) atmospheric observatory. Our study also benefits from state-of-the-art laboratory facilities that include three-dimensional molecular imaging techniques enabled by secondary ion mass spectrometry and nanogram-level chemical composition analysis via micronebulization aerosol mass spectrometry. Through our study, we have developed a framework for observation–modeling integration, enabling an examination of how various assumptions about the organic–inorganic components mixing state, inferred from chemical analysis, affect clouds and radiation in observation-constrained model simulations. By integrating observational constraints (derived from offline chemical analysis of the aerosol surface using collected samples) with in situ UAS observations, we have identified a prominent role of organic-enriched nanometer layers located at the surface of aerosol particles in determining profiles of aerosol optical and hygroscopic properties over the SGP observatory. Furthermore, we have improved the agreement between predicted clouds and ground-based cloud lidar measurements. This UAS–model–laboratory integration exemplifies how these new advanced capabilities can significantly enhance our understanding of aerosol–radiation–cloud interactions.

54 ENVIRONMENTAL SCIENCES↗

Comparability of Liquid Chromatography Tandem Mass Spectrometry Analysis of Dissolved Organic Matter across Laboratories

Non-targeted liquid chromatography tandem highresolution mass spectrometry (LC−MS/MS) is increasingly applied for the structure-resolved chemical analysis of dissolved organic matter (DOM). With new developments in MS instrumentation and analysis software, the approach has gained substantial momentum over the past decade. However, achieving high-quality analytical data that is reproducible and comparable across laboratories can be a bottleneck in non-targeted metabolomics and organic matter chemical analysis, especially for data reuse in repository-scale analyses. Understanding the capabilities as well as challenges of comparing LC−MS/MS data from different laboratories is necessary for inferring global trends from public data sets. To illuminate instrumentation factors that drive differences and variability, we used a standardized data analysis pipeline, including classical (CMN) and featurebased molecular networking (FBMN), to analyze data from a ring trial by 24 laboratories on identical sample sets of algal and DOM extracts that were mixed in predefined concentrations and spiked with standards. Our results showed that data sets from similar mass spectrometer types with unified instrument parameters were qualitatively comparable, resolving the same general trends and shared mass spectral features. Interlaboratory comparability was best for high-intensity features, while low-intensity features showed greater detection variability. Our analysis also highlights challenges when comparing data from instruments with different acquisition rates or operating with less standardized methods. Lastly, we provide recommendations for data integration, public data sharing, standardization, and best practices for standardized LC−MS/MS data acquisition, which will be critical for long-term time series and intercomparability of DOM chemical analyses.

DOM↗