Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spatial”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Spatial correlation of photon pairs produced in spontaneous parametric down-conversion

We report the observation of spatial biphoton correlation in spontaneous parametric down conversion. The optical bench includes a type-I BBO crystal of effective length 2 mm, pumped by a 100 mW violet laser diode centered at 405.38 nm. Photon pairs are created with degenerate wavelength {approx_equal}810.76 nm. Once the horizontal counting rates have been measured, a simple geometrical recipe is shown to be useful in calculating bounds for the width of vertical counting rates. The spatial correlation between idler and signal photons is illustrated with a coincidence distribution of the coordinate pair (x{sub s},x{sub i}), with x{sub i,s} the idler (signal) detector position in horizontal scan.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spatially autoresonant stimulated Raman scattering in inhomogeneous plasmas in the kinetic regime

The impact of spatial autoresonance on backward stimulated Raman scattering in inhomogeneous plasmas is investigated in the regime where the dominant nonlinear frequency shift of the Langmuir wave is due to kinetic effects. By numerically solving the coupled mode equations, the spatial growth of the Langmuir wave is observed to self-adjust so as to cancel the detuning from resonance due to inhomogeneity, giving rise to phase-locked solutions to the electron plasma wave equation. For a single resonant point in a linear density profile, the envelope of the electron plasma wave is characterized by a growth that begins at the resonant point and is proportional to the square of distance propagated. In the more physical case where the scattered light is seeded with a broadband noise, autoresonance may lead to a reflectivity well above the level predicted by the usual Rosenbluth gain factor [M. N. Rosenbluth, Phys. Rev. Lett. 29, 565 (1972)].

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast Transient And Spatially Non-Homogenous Accident Analysis Of Two-Dimensional Cylindrical Nuclear Reactor

The research about fast transient and spatially non-homogenous nuclear reactor accident analysis of two-dimensional nuclear reactor has been done. This research is about prediction of reactor behavior is during accident. In the present study, space-time diffusion equation is solved by using direct methods which consider spatial factor in detail during nuclear reactor accident simulation. Set of equations that obtained from full implicit finite-difference discretization method is solved by using iterative methods ADI (Alternating Direct Implicit). The indication of accident is decreasing macroscopic absorption cross-section that results large external reactivity. The power reactor has a peak value before reactor has new balance condition. Changing of temperature reactor produce a negative Doppler feedback reactivity. The reactivity will reduce excess positive reactivity. Temperature reactor during accident is still in below fuel melting point which is in secure condition.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Temporal and spatial study of neon ion emission from a plasma focus device

The temporal and spatial characteristics of the neon ion beam emissions from a low energy plasma focus device have been studied by employing a multiple Faraday cup assembly and the CR-39 track detectors at different angular and axial positions. In addition, the operating gas pressures were also varied to study the temporal and spatial characteristics of the neon ion beam emissions. The Faraday cup analyses show that the ion flux strongly depends on the operating gas pressure as well as the angular positions. The estimated ion energy measurements at the aperture of the Faraday cup indicate that the plasma focus device is a source of polyenergetic ions ranging from approximately a few keV to a few hundreds of keV, irrespective of the angular positions. The exposed CR-39 detectors have shown the formation of multiple ion tracks with diameter ranging from 2 to 13 {mu}m. The populations of lower diameter tracks (2-6 {mu}m) are observed to be more at 0 deg. and 10 deg. angles. It is also noticed that the most populated track counts have shifted toward the higher diameter as the angular positions change from 0 deg. to 70 deg. The present study enables us to predict a clear picture of ion flux and energy distribution inside the plasma focus chamber that will help to use the device for material irradiation application in a more controlled manner.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatially resolved lasers using a glassy cholesteric liquid crystal film with lateral pitch gradient

To fabricate spatially resolved glassy cholesteric liquid crystal (CLC) lasers, a lateral pitch gradient was introduced by thermally activated diffusion across the interface of two films comprising nematic and cholesteric oligofluorene doped with a red-emitting oligifluorene. The formation of spatially resolved Grandjean–Cano bands was accountable by strong surface anchoring at substrates and the qualitative chiral concentration profile. Across each band there was a common stop band, and a set of bands produced multiple lasing peaks across the spectral range determined by light-emitter’s fluorescence spectrum. The resultant lasing thresholds, 6.6–7.6 mJ/cm 2 , and slope efficiencies, 0.2%–1.5%, are superior to those reported to date for gradient-pitch CLC lasers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-Resolution X-ray Microprobe Using a Spatial Filter and Its Application to Micro-XAFS Measurements

An x-ray microprobe system with total-reflection mirror optics for trace element analysis has been developed at beamline 37XU of SPring-8. To achieve sub-microprobe, a spatial filter has been installed downstream of a monochromator. Focusing tests have been performed in the x-ray energy range of 6-14 keV. A focused beam size of 0.83 {mu}m(V)x1.35 {mu}m(H) has been obtained at an x-ray energy of 10 keV, and using a spatial filter in the horizontal direction, the beam size is down to 0.84 {mu}m. Micro-x-ray absorption fine structure (XAFS) spectroscopy of submicrometer particles has been done by utilizing the total-reflection mirror optics. It was clearly observed from the nickel K-edge XAFS spectra that the oxidation state of nickel was a mixture of metal and oxide even in the single submicrometer particle.

07 ISOTOPE AND RADIATION SOURCES↗

Strong terahertz radiation by beating of spatial-triangular lasers in a plasma

Resonant excitation of terahertz (THz) radiation by beating of two spatial-triangular laser beams having different frequencies and wave numbers but the same electric fields is proposed, where the ponderomotive force in the transverse direction is realized due to the beating and spatial variation of the lasers' fields. This gives rise to a stronger transient transverse current due to a sharp gradient in the laser field, and subsequently THz radiation is excited resonantly in the presence of a periodic density structure. The present scheme yields the THz field {approx}10{sup 5} kV/cm and the efficiency {approx}10{sup -2} for the laser intensity {approx}10{sup 14} W/cm{sup 2}.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a Negative Hydrogen Ion Source for Spatial Beam Profile Measurement of a High Intensity Positive Ion Beam

We have been developing a negative hydrogen ion (H{sup -} ion) source for a spatial beam profile monitor of a high intensity positive ion beam as a new diagnostic tool. In case of a high intensity continuous-wave (CW) deuteron (D{sup +}) beam for the International Fusion Materials Irradiation Facility (IFMIF), it is difficult to measure the beam qualities in the severe high radiation environment during about one-year cyclic operation period. Conventional techniques are next to unusable for diagnostics in the operation period of about eleven months and for maintenance in the one-month shutdown period. Therefore, we have proposed an active beam probe system by using a negative ion beam and started an experimental study for the proof-of-principle (PoP) of the new spatial beam profile monitoring tool. In this paper, we present the status of development of the H{sup -} ion source as a probe beam source for the PoP experiment.

43 PARTICLE ACCELERATORS↗

Quantification of errors in large-eddy simulations of a spatially evolving mixing layer using polynomial chaos

A stochastic approach based on generalized polynomial chaos (gPC) is used to quantify the error in large-eddy simulation (LES) of a spatially evolving mixing layer flow and its sensitivity to different simulation parameters, viz., the grid stretching in the streamwise and lateral directions and the subgrid-scale (SGS) Smagorinsky model constant (C{sub S}). The error is evaluated with respect to the results of a highly resolved LES and for different quantities of interest, namely, the mean streamwise velocity, the momentum thickness, and the shear stress. A typical feature of the considered spatially evolving flow is the progressive transition from a laminar regime, highly dependent on the inlet conditions, to a fully developed turbulent one. Therefore, the computational domain is divided in two different zones (inlet dependent and fully turbulent) and the gPC error analysis is carried out for these two zones separately. An optimization of the parameters is also carried out for both these zones. For all the considered quantities, the results point out that the error is mainly governed by the value of the C{sub S} constant. At the end of the inlet-dependent zone, a strong coupling between the normal stretching ratio and the C{sub S} value is observed. The error sensitivity to the parameter values is significantly larger in the inlet-dependent upstream region; however, low-error values can be obtained in this region for all the considered physical quantities by an ad hoc tuning of the parameters. Conversely, in the turbulent regime the error is globally lower and less sensitive to the parameter variations, but it is more difficult to find a set of parameter values leading to optimal results for all the analyzed physical quantities. A similar analysis is also carried out for the dynamic Smagorinsky model, by varying the grid stretching ratios. Comparing the databases generated with the different subgrid-scale models, it is possible to observe that the error cost function computed for the streamwise velocity and for the momentum thickness is not significantly sensitive to the used SGS closure. Conversely, the prediction of the shear stress is much more accurate when using a dynamic subgrid-scale model and the variance of the error is lower in magnitude.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spatially resolving variations in giant magnetoresistance, undetectable with four-point probe measurements, using infrared microspectroscopy

Magnetorefractive infrared (IR) microspectroscopy is demonstrated to resolve spatial variations in giant magnetoresistance (GMR) and, by modelling, provide an insight into the origin of the variations. Spatial variations are shown to be masked in conventional four-point probe electrical or IR spectral measurements. IR microspectroscopy was performed at the SMIS beamline at the SOLEIL synchrotron, modified to enable measurements in magnetic fields. A GMR gradient was induced in a CoFe/Cu multilayer sample by annealing in a temperature gradient. Modelling revealed that variations in GMR at 900 Oe could be attributed to local variations in interlayer coupling locally changing the switching field.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Diagnosing the plasma nonuniformity in an iron opacity experiment by spatially resolved Al 1s-2p absorption spectroscopy

Generating a well-characterized hot-dense sample is of great importance to high quality opacity measurements. In this paper, we report on an experimental investigation of the plasma nonuniformity in a radiatively heated iron opacity sample by spatially resolved Al 1s-2p absorption spectroscopy. The iron sample was tamped by plastic at both sides and was heated by thermal x-ray radiation generated in a gold Hohlraum, and an Al layer attached to it was used as a tracer for temperature diagnosis. Spatially resolved 1s-2p transition absorption spectra of the Al tracer were measured by the technique of point-projection-spectroscopy, and temperatures in the sample were obtained by comparing the measured spectra with detailed-term-accounting model calculations, with the density of the sample deduced using a combination of side-on radiography and radiative hydrodynamic simulation. The results showed the existence of axial temperature nonuniformity in the sample, and these temperature variations have been used to explain the shift of iron 2p-3d transition absorption feature along the axial direction of the Hohlraum used to heat the sample successfully.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Formation of spatially periodic fronts of high-energy electrons in a radio-frequency driven surface microdischarge

The generation of spatially periodic fronts of high-energy electrons (>13.48 eV) has been investigated in a radio-frequency surface microdischarge in atmospheric-pressure argon. Optical emission spectroscopy is used to study the Ar I 2p{sub 1}-1s{sub 2} transition surrounding a filamentary microdischarge, both spatially and with respect to the phase of the applied voltage. The formation of excitation fronts, which remain at a constant propagation distance throughout the RF cycle and for the duration of the pulse, may be explained by a localized increase in the electric field at the tip of surface-charge layers that are deposited during the extension phase.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measuring time of flight of fusion products in an inertial electrostatic confinement fusion device for spatial profiling of fusion reactions

A new diagnostic has been developed that uses the time of flight (TOF) of the products from a nuclear fusion reaction to determine the location where the fusion reaction occurred. The TOF diagnostic uses charged particle detectors on opposing sides of the inertial electrostatic confinement (IEC) device that are coupled to high resolution timing electronics to measure the spatial profile of fusion reactions occurring between the two charged particle detectors. This diagnostic was constructed and tested by the University of Wisconsin-Madison Inertial Electrostatic Confinement Fusion Group in the IEC device, HOMER, which accelerates deuterium ions to fusion relevant energies in a high voltage ({approx}100 kV), spherically symmetric, electrostatic potential well [J. F. Santarius, G. L. Kulcinski, R. P. Ashley, D. R. Boris, B. B. Cipiti, S. K. Murali, G. R. Piefer, R. F. Radel, T. E. Radel, and A. L. Wehmeyer, Fusion Sci. Technol. 47, 1238 (2005)]. The TOF diagnostic detects the products of D(d,p)T reactions and determines where along a chord through the device the fusion event occurred. The diagnostic is also capable of using charged particle spectroscopy to determine the Doppler shift imparted to the fusion products by the center of mass energy of the fusion reactants. The TOF diagnostic is thus able to collect spatial profiles of the fusion reaction density along a chord through the device, coupled with the center of mass energy of the reactions occurring at each location. This provides levels of diagnostic detail never before achieved on an IEC device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Power-law spatial dispersion from fractional Liouville equation

A microscopic model in the framework of fractional kinetics to describe spatial dispersion of power-law type is suggested. The Liouville equation with the Caputo fractional derivatives is used to obtain the power-law dependence of the absolute permittivity on the wave vector. The fractional differential equations for electrostatic potential in the media with power-law spatial dispersion are derived. The particular solutions of these equations for the electric potential of point charge in this media are considered.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Supercontinuum spatial modulation spectroscopy: Detection and noise limitations

Supercontinuum spatial modulation spectroscopy is a facile tool for conducting single molecule/particle extinction spectroscopy throughout the visible and near infrared (420–1100 nm). The technique's capabilities are benchmarked using individual Au nanoparticles (NPs) as a standard since they are well studied and display a prominent plasmon resonance in the visible. Extinction spectra of individual Au NPs with diameters (d) ranging from d ∼ 8 to 40 nm are resolved with extinction cross sections (σ{sub ext}) of σ{sub ext} ∼1 × 10{sup −13}–1 ×10{sup −11} cm{sup 2}. Corresponding signal-to-noise ratios range from ∼30 to ∼1400. The technique's limit of detection is determined to be 4.3 × 10{sup −14} cm{sup 2} (4.3 nm{sup 2}). To showcase supercontinuum spatial modulation spectroscopy's broader applicability, extinction spectra are acquired for other model systems, such as individual single-walled carbon nanotubes (SWCNTs) and CdSe nanowires. We show for the first time extinction spectra of individual (8,3) and (6,5) SWCNTs. For both chiralities, their E{sub 11} [(8,3) 1.30 eV (952 nm); (6,5) 1.26 eV (986 nm)] and E{sub 22} [(8,3) 1.86 eV (667 nm); (6,5) 2.19 eV (567 nm)] excitonic resonances are seen with corresponding cross sections of σ{sub ext} ∼ 10{sup −13} cm{sup 2} μm{sup −1}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interplay of point defects, extended defects, and carrier localization in the efficiency droop of InGaN quantum wells light-emitting diodes investigated using spatially resolved electroluminescence and photoluminescence

We perform both spatially resolved electroluminescence (SREL) as a function of injection current and spatially resolved photoluminescence (SRPL) as a function of excitation power on InGaN quantum well blue light-emitting diodes to investigate the underlying physics for the phenomenon of the external quantum efficiency (EQE) droop. SREL allows us to study two most commonly observed but distinctly different droop behaviors on a single device, minimizing the ambiguity trying to compare independently fabricated devices. Two representative devices are studied: one with macroscopic scale material non-uniformity, the other being macroscopically uniform, but both with microscopic scale fluctuations. We suggest that the EQE–current curve reflects the interplay of three effects: nonradiative recombination through point defects, carrier localization due to either In composition or well width fluctuation, and nonradiative recombination of the extended defects, which is common to various optoelectronic devices. By comparing SREL and SRPL, two very different excitation/detection modes, we show that individual singular sites exhibiting either particularly strong or weak emission in SRPL do not usually play any significant and direct role in the EQE droop. We introduce a two-level model that can capture the basic physical processes that dictate the EQE–current dependence and describe the whole operating range of the device from 0.01 to 100 A/cm{sup 2}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Note: Laser beam scanning using a ferroelectric liquid crystal spatial light modulator

In this work we describe laser beam scanning using a ferroelectric liquid crystal spatial light modulator. Commercially available ferroelectric liquid crystal spatial light modulators are capable of displaying 85 colored images in 1 s using a time dithering technique. Each colored image, in fact, comprises 24 single bit (black and white) images displayed sequentially. We have used each single bit image to write a binary phase hologram. For a collimated laser beam incident on the hologram, one of the diffracted beams can be made to travel along a user defined direction. We have constructed a beam scanner employing the above arrangement and demonstrated its use to scan a single laser beam in a laser scanning optical sectioning microscope setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Temporally and spatially resolved characterization of microwave induced argon plasmas: Experiment and modeling

Experiments and modeling of the plasma-microwave interaction have been performed in a coaxial microwave plasma source at a field frequency of 2.45 GHz generating argon plasmas at pressures of 20 and 40 millibars and a ratio of flow rate to pressure of 0.125 sccm/Pa. The incident microwave power between 100 W and 300 W is supplied in a regime of a pulse-width modulation with cycle duration of 110 ms and a power-on time of 23 ms. The experiments are based on heterodyne reflectometry and microwave interferometry at 45.75 GHz. They provide the temporal behaviour of the complex reflection coefficient, the microwave power in the plasma, as well as the electron density in the afterglow zone of the discharge. The self-consistent spatially two-dimensional and time-dependent modeling complements the analysis of the plasma-microwave interaction delivering the plasma and electromagnetic field parameters. The consolidating experimental observations and model predictions allow further characterizing the plasma source. The generated plasma has a core occupying the region close to the end of the inner electrode, where maximum electron densities above 10{sup 20} m{sup −3} and electron temperatures of about 1 eV are observed. Due to a longer outer electrode of the coaxial structure, the plasma region is extended and fills the volume comprised by the outer electrode. The electron density reaches values of the order of 10{sup 19} m{sup −3}. The heating of the gas occurs in its great part due to elastic collisions with the plasma electrons. However, the contribution of the convective heating is important especially in the extended plasma region, where the gas temperature reaches its maximum values up to approximately 1400 K. The temporally and spatially resolved modeling enables a thorough investigation of the plasma-microwave interaction which clearly shows that the power in-coupling occurs in the region of the highest electron density during the early stage of the discharge. In the steady state phase, however, the power in-coupling occurs close to the source walls where the electron density is significantly lower than on the discharge axis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗