Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “solutions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Interaction of Concentrated (68%) Aqueous Nitric Acid Solutions with Cheesecloth: A TGA-DSC-MS Study

The exposure of cotton cheesecloth to concentrated aqueous solutions of nitric acid reduced the onset of combustion by 30-40°C (from ~350°C to ~310°C) relative to that of both unexposed cheesecloth and cheesecloth that was rinsed immediately following exposure to the same solution. Cheesecloth exposed to concentrated (68%) nitric acid underwent three exothermic pre-combustion reactions which onset at 125-135°C, 160- 170°C and 200-210°C. These reactions give off mostly water vapor, with lesser amounts of NO and carbon dioxide. Exposure to concentrated nitric acid damages the cellulose polymers, oxidizing them, reducing them in length, and increasing their reactivity in response to thermal stress. Cheesecloth which was rinsed after exposure behaved similarly to unexposed cheesecloth, indicating that NC was not formed on exposure to the concentrated aqueous nitric acid solution. The addition of a 239Pu – 241Am spike in an aqueous nitric – hydrofluoric solution to the cheesecloth reduced the onset temperature of the first exothermic reaction to 126°C and lowered the onset temperature of combustion from ~310°C to ~275°C. When dried on to cellulose substrates in the presence of excess nitrate, metal ions may act as oxidizers, or may catalyze the oxidation of the carbonaceous material, lowering ignition temperatures. No evidence for the formation of nitrocellulose following the exposure of cheesecloth to nitric acid was observed during this study

36 MATERIALS SCIENCE↗

Evaluating a Semi-Quantitative, Spectrophotometric Method for the Rapid Determination of Total Rare Earth Element Concentrations in Citrate Leaching Solutions

Quick, reliable methods to measure the rare earth elements (REEs) in process streams are needed to support real-time parameterization and monitoring for a burgeoning number of REE extraction schemes. Such methods would ideally be fast, reproducible, and field-deployable. This study evaluates the feasibility of using a chromogenic indicator, arsenazo(III) (hereafter abbreviated as Arsz(III)) to detect the concentration of REEs in complex citrate leaching solutions using a spectrophotometer. Arsz(III) forms a chromogenic complex with the lanthanide elements that produces a blue/purple color detectable in the visible light range. Matrices of solutions containing varied concentrations of calcium, iron, and lanthanum were scanned in the presence of an Arsz(III) indicator to generate a modeled relationship that could be used to back calculate REE concentrations. While relatively quick (scan times on the order of seconds), the results indicated that the calcium and iron concentrations of typical mining solutions overwhelm the signal of the REEs, to the extent that sensitivity of the method is no less than 50 µM REEs. These results demonstrate the difficulties of accurately measuring trace metals in complex solutions, although the method may still hold utility for processes with significantly lower calcium and iron concentrations or REE concentrations much greater than 50 µM.

36 MATERIALS SCIENCE↗

Performance Demonstration of an Occupancy Sensor-enabled Integrated Solution for Commercial Buildings

Traditionally, a single-loop fixed-gain controller is applied to supply fan (SF) and cooling coil (CC) valve controls while a fixed-damper position control is applied to outdoor air (OA) damper control at air handling units (AHUs) in commercial buildings. With the increasing application of occupancy sensors, the information generated by occupancy sensors is applied to not only reduce the electricity loads from lighting and controllable plug loads, but also reset OA intake and minimum supply airflow setpoints. Meanwhile, these intermittent operation actions greatly elevate the dynamics of AHU systems, which may introduce unstable SF and CC valve operations and inaccurate OA flow control at AHUs and consequently degrade maximum energy efficiency gains. With virtual fan and valve flow meter technologies, two advanced controls, including cascade control and gain scheduling control, can be implemented on both the SF and CC valve, and an advanced control using a virtual OA flow meter can be implemented on OA damper integrated with occupancy sensors. The goal of this project is to demonstrate the savings, cost, and performance of an integrated solution that integrates the three advanced HVAC controls with occupancy sensors to allow accurate and stable AHU operations in real buildings. The project objectives are to: 1) develop and validate an advance SF control algorithm; 2) develop and validate an advanced CC valve control algorithm; 3) validate an algorithm to implement a virtual OA flow meter; and 4) demonstrate the savings, cost, and performance of the integrated solution in real buildings. The technical approaches are to: 1) select a test system at the University of Oklahoma; 2) develop and implement the algorithms of advanced SF and CC valve controls and validate the performance; 3) develop and implement the advanced OA control using a virtual OA flow meter and validate the performance; 4) demonstrate the savings, cost, and performance of the proposed integrated solution with and without three advanced HVAC controls; and 5) disseminate the project results through publications and presentations. For the SF control, both the gain scheduling and cascade controls can improve the fan energy performance by reducing the fan power during the transient period and the fan control performance at lower speeds by reducing fan speed variation. Moreover, the gain scheduling control provides a simple and low-cost solution and is recommended. The fan power savings can reach 30% in a transient period. For the CC valve control, the gain scheduling control can considerably reduce the supply air temperature oscillation range and frequency under both higher and lower load conditions and the control valve response is much more stable. As a result, the gain scheduling control is recommended. The projected pump energy consumption can be reduced by 68.5%. With the developed virtual OA flow meter, the OA can be accurately controlled at its setpoint, which is determined based on the actual number of occupants in the building provided by occupancy sensors. The RMSE of the proposed OA control is 15.9 L/s. The energy data shows that the fan power and CC cooling energy were significantly reduced. On the other hand, the energy savings majorly results from the occupancy sensors and the energy savings by the advanced HVAC controls is minimal because that the controllers in the test AHU were tuned with very slow response. An annual technical savings potential is estimated as 0.5 quads in the commercial sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparing the MELCOR Aerosol Deposition Model with Exact Analytical Solutions

Exact analytical solutions are presented for the evolution of the aerosol particle mass density function in a control volume for particle deposition due to gravitational settling, thermophoresis, and diffusion. The solutions are for arbitrary initial mass density functions and are applied for an initial lognormal density function. Integration of these solutions provides the suspended mass in the control volume as a function of time. These solutions serve as an exact benchmark to assess the accuracy of numerical methods. For the numerical algorithm used in MELCOR, excellent agreement is obtained for gravitational settling, diffusive deposition, and thermophoretic deposition for the suspended aerosol mass. In all cases, the default number of discrete particle size bins of 10 is shown to converge, with hardly any advantage to using 20 size bins.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Implementation and Operation of Power Flow Control Solutions for Transmission Systems

Power-flow controls (PFCs) technologies provide a suite of alternatives to more-efficiently direct the flow of power on the grid, improving flexibility and enabling the grid to be more responsive and resilient. PFCs can be used in many cases to mitigate overloads and consequently defer the installation of grid-expansion projects. They can also be suitable options in situations where new transmission lines cannot be built because of environmental constraints, land use, or other types of restrictions. Other uses include mitigation of loop or unintended flows, forcing of contractual or scheduled flows, reduction of congestion, and mitigation solutions during large maintenance or construction projects. While many studies have demonstrated the potential economic benefits of PFC for different types of applications, the implementation implications of using multiple PFCs for system operation and reliability have not been analyzed in detail. The lack of information and practical experience on these aspects hinders adoption of this technology. One use case would be that multiple PFCs are required to coordinate congestion management. In such cases, multiple PFCs are deployed in a meshed power system to control power flows across a wide area. The challenges are associated with PFC interaction—namely, the self and mutual power-flow sensitivity of each PFC, which must be accounted for in the calculation of the respective operating setpoints. This report analyzes implementation and operation that must be considered in evaluating transmission solutions using PFCs. The report first analyzes attributes with which PFC-based solutions should comply, based on the objective and characteristics of each particular use case. It then describes different approaches for coordinated control of multiple PFC devices for different applications, including options to avoid adverse interactions and reduce risks due to inappropriate coordination. Control and operation are illustrated through case studies performed on both generic and actual power system models. This report provides insights for transmission planners and operation engineers about the implementation of PFC-based transmission solutions; consequently, it will help them make informed decisions about the adoption of the technology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhancing Power Resilience for Remote Communities: A Comprehensive Renewable Energy Solution for Itbayat Island

The island of Itbayat, Philippines, faces significant challenges in maintaining a reliable and resilient power supply due to its current reliance on a vulnerable power distribution system managed by a local electric cooperative. The existing infrastructure, which includes diesel generators and a radial network configuration with some above-ground lines, is highly susceptible to frequent typhoons and adverse weather conditions. These factors, combined with inadequate staffing and high operational costs, result in frequent power outages that disrupt daily life and hinder economic development. This white paper proposes a comprehensive solution to enhance the resilience and reliability of Itbayat's power system by integrating renewable energy sources, specifically solar photovoltaic (PV) systems, battery storage, and a microgrid controller. The proposed solution aims to reduce dependency on diesel fuel, optimize energy use, and provide a sustainable and robust power supply for the island. Key components of the solution include: 1. Solar PV Installation: Deploying solar PV panels to harness abundant solar energy, reducing reliance on diesel fuel. 2. Battery Storage Systems: Installing battery storage to store excess solar energy and ensure a continuous power supply during low solar generation periods. 3. Microgrid Controller: Implementing a microgrid controller to manage and optimize the integration of solar PV, battery storage, and existing diesel generators. The proposed solution addresses several critical issues, including system vulnerability, generator dependency, and operational inefficiencies. By adopting this innovative approach, Itbayat Island can achieve a more resilient, efficient, and sustainable energy infrastructure, ensuring a stable power supply for its residents and enhancing overall energy security.

14 SOLAR ENERGY↗

Closed-form solutions towards real-time energy-optimal and collision-free speed planning with limited information

Under real-world driving conditions, available information is limited due to communication range, and connected and automated vehicles (CAVs) must plan and follow energy-optimal and collision-free speed trajectory with a high updating rate. To this end, this paper presents a holistic design of a speed planning algorithm using analytical closed-form optimal solutions. Using the simplest vehicle model, we derive closed-form solutions as a function of boundary conditions, and summarize them without and with state constraints imposed by speed limits and vehicle in front. Then, we introduce multiple modes (e.g., eco-approach to traffic signal) to properly respond dynamically changing situations, and present how to set boundary conditions for each mode, while guaranteeing nature of globally optimal solutions. Finally, we perform a large-scale simulation study to identify and quantify the energy impacts of CAVs for real-world driving routes. A simple but effective algorithm based on closed-form solutions shows a significant energy saving potential in comparison with human-driven vehicle and adaptive cruise controlled vehicle with connectivity.

Han, Jihun↗

On the Verification of Deep Reinforcement Learning Solution for Intelligent Operation of Distribution Grids

Capabilities of deep reinforcement learning (DRL) in obtaining fast decision policies in high dimensional and stochastic environments have led to its extensive use in operational research, including the operation of distribution grids with high penetration of distributed energy resources (DER). However, the feasibility and robustness of DRL solutions are not guaranteed for the system operator, and hence, those solutions may be of limited practical value. This paper proposes an analytical method to find feasibility ellipsoids that represent the range of multi-dimensional system states in which the DRL solution is guaranteed to be feasible. Empirical studies and stochastic sampling determine the ratio of the discovered to the actual feasible space as a function of the sample size. In addition, the performance of logarithmic, linear, and exponential penalization of infeasibility during the DRL training are studied and compared in order to reduce the number of infeasible solutions

Hosseini, Mohammad Mehdi↗

A bicarbonate-rich liquid condensed phase in non-saturated solutions in the absence of divalent cations

Bicarbonate (HCO 3 - ) and sodium (Na + )-containing solutions contain droplets of a separate, bicarbonate-rich liquid condensed phase (LCP) that have higher concentrations of HCO 3 - relative to the bulk solution in which they reside. The existence and composition of the LCP droplets has been investigated by nanoparticle tracking analysis, nuclear magnetic resonance spectroscopy, refractive index measurements and X-ray pair distribution function analysis. The bicarbonate-rich LCP species is a previously unaccounted-for, ionic phenomenon which occurs even in solutions with solely monovalent cations. Its existence requires re-evaluation of models used to describe and model aqueous solution physicochemistry, especially those used to describe and model carbonate mineral formation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Kink solutions with power law tails

We present a comprehensive review about the various facets of kink solutions with a power law tail, which have received considerable attention during the last few years. This area of research is in its early stages; although several aspects have become clear by now, there are a number of issues which have only been partially understood or not understood at all. We first discuss the aspects which are reasonably well known and then address in some detail the issues which are only partially or not understood at all. We present a wide class of higher (than sixth) order field theory models admitting implicit kink as well as mirror kink solutions where the two tails facing each other have a power law or a power-tower type fall off, whereas the other two ends not facing each other could have either an exponential or a power law tail. The models admitting implicit kink solutions where the two ends facing each other have an exponential tail while the other two ends have a power law tail are also discussed. Moreover, we present several field theory models which admit explicit kink solutions with a power law fall off; we note that in all these polynomial models while the potential V ( ϕ ) is continuous, its derivative is discontinuous. We also discuss one of the most important and only partially understood issues of the kink–kink and the kink–antikink forces in case the tails facing each other have a power law fall off. Finally, we briefly discuss the kink–antikink collisions at finite velocity and present some open questions.

power-tower tail↗

Pilot Scale Testing of Lignite Adsorption Capability and the Benefits for the Recovery of Rare Earth Elements from Dilute Leach Solutions

Naturally occurring organic materials containing humic acids show a strong affinity towards rare earth elements (REE) and other critical elements. Leaching experiments on lignite coal waste produced from construction sand production revealed that the contained REEs were associated with the organic matter. Furthermore, adsorption studies revealed that the lignite waste was capable of extracting REEs from a model solution and increased the REE content of the lignite waste by more than 100%. As such, this study aimed to utilize the lignite waste to adsorb REEs from pregnant leach solutions and acid mine drainage sources having low REE concentrations and subsequently leach the lignite material to produce pregnant leach solutions containing relatively high amounts of REEs, which benefits the performance and economic viability of downstream separation and purification processes. An integrated flowsheet was developed based on this concept and tested at a pilot scale. The pregnant leachate solution (PLS) was generated from a heap leach pad containing 2000 tons of Baker seam coarse refuse. The pilot scale circuit was comprised of aluminum precipitation, adsorption using the waste lignite, and rare earth-critical metal (RE-CM) precipitation stages in succession. The results indicated that the aluminum precipitation stage removed over 88% and 99% of the Al and Fe, respectively. The adsorption stage increased the REE content associated with the waste lignite from 457 ppm to 1065 ppm on a whole mass basis. Furthermore, the heavy REE (HREE) content in the feedstock increased by approximately 250%, which raised the percentage of HREE in the REE distribution by 19 absolute percentage points. In addition to the REEs, concentrations of other critical elements such as Mn, Ni, and Zn also improved by 75%, 37%, and 250%, respectively. Bench-scale tests revealed that increasing the solids concentration in the waste lignite and PLS mix from 1% to 20% by weight enhanced the adsorption efficiency from 32.0% to 99.5%, respectively. As such, a new flowsheet was proposed which provides significantly higher REE concentrations in the PLS that can be fed directly to solvent extraction and/or oxalic acid precipitation and, thereby, enhancing process efficiency and economics.

58 GEOSCIENCES↗

Modeling Solution Drying by Moving a Liquid-Vapor Interface: Method and Applications

A method of simulating the drying process of a soft matter solution with an implicit solvent model by moving the liquid-vapor interface is applied to various solution films and droplets. For a solution of a polymer and nanoparticles, we observe “polymer-on-top” stratification, similar to that found previously with an explicit solvent model. Furthermore, “polymer-on-top” is found even when the nanoparticle size is smaller than the radius of gyration of the polymer chains. For a suspension droplet of a bidisperse mixture of nanoparticles, we show that core-shell clusters of nanoparticles can be obtained via the “small-on-outside” stratification mechanism at fast evaporation rates. “Large-on-outside” stratification and uniform particle distribution are also observed when the evaporation rate is reduced. Polymeric particles with various morphologies, including Janus spheres, core-shell particles, and patchy particles, are produced from drying droplets of polymer solutions by combining fast evaporation with a controlled interaction between the polymers and the liquid-vapor interface. Our results validate the applicability of the moving interface method to a wide range of drying systems. The limitations of the method are pointed out and cautions are provided to potential practitioners on cases where the method might fail.

36 MATERIALS SCIENCE↗

Experimental Determination of Solubilities of Sodium Polyborates In MgCl 2 Solutions: Solubility Constant of Di-Sodium Hexaborate Tetrahydrate, and Implications For the Diagenetic Formation of Ameghinite

In this paper, solubility measurements were conducted for sodium polyborates in MgCl 2 solutions at 22.5 ± 0.5 °C. According to solution chemistry and XRD patterns, di-sodium tetraborate decahydrate (borax) dissolves congruently, and is the sole solubility-controlling phase, in a 0.01 mol/kg MgCl 2 solution: Na 2 B 4 O 7 •10H 2 O(cr) ⇌ 2Na + + 4B(OH) 4 + 2H + + H 2 O(l). However, in a 0.1 mol/kg MgCl 2 solution borax dissolves incongruently and is in equilibrium with di-sodium hexaborate tetrahydrate: 2Na 2 B 6 O 10 •4H 2 O(cr) + 2Na + + 23H 2 O(l) ⇌ 3Na 2 B 4 O 7 •10H 2 O(cr) + 2H + . In this study, the equilibrium constant (log K 0 ) for Reaction 2 at 25 °C and infinite dilution was determined to be –16.44 ± 0.13 (2σ) based on the experimental data and the Pitzer model for calculations of activity coefficients of aqueous species. In accordance with the log K 0 for Reaction 1 from a previous publication from this research group, and log K 0 for Reaction 2 from this study, the equilibrium constant for dissolution of di-sodium hexaborate tetrahydrate at 25 °C and at infinite dilution, Na 2 B 6 O 10 •4H 2 O(cr) + 10H 2 O(l) ⇌ 2Na + + 6B(OH) 4 - + 4H + was derived to be –45.42 ± 0.16 (2σ). The equilibrium constants determined in this study can find applications in many fields. For example, in the field of nuclear waste management, the formation of di-sodium hexaborate tetrahydrate in brines containing magnesium will decrease borate concentrations, making less borate available for interactions with Am(III). In the field of experimental investigations, based on the equilibrium constant for Reaction 2, the experimental systems can be controlled in terms of acidity around neutral pH by using the equilibrium assemblage of borax and di-sodium hexaborate tetrahydrate at 25 °C. As salt lakes and natural brines contain both borate and magnesium as well as sodium, the formation of sodium hexaborate tetrahydrate may influence the chemical evolution of salt lakes and natural brines. Di-sodium hexaborate tetrahydrate is a polymorph of the mineral ameghinite [chemical formula Na 2 B 6 O 10 •4H 2 O; structural formula NaB 3 O 3 (OH) 4 or Na 2 B 6 O 6 (OH) 8 ]. Finally, di-sodium hexaborate tetrahydrate could be a precursor of ameghinite and could be transformed when borate deposits are subject to diagenesis.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MAGNETO-ACOUSTIC WAVES IN A GRAVITATIONALLY STRATIFIED MAGNETIZED PLASMA: EIGEN-SOLUTIONS AND THEIR APPLICATIONS TO THE SOLAR ATMOSPHERE

Magneto-acoustic gravity (MAG) waves have been studied intensively in the context of astrophysical plasmas. There are three popular choices of analytic modeling using a Cartesian coordinate system: a magnetic field parallel, perpendicular, or at an angle to the gravitational field. Here, we study a gravitationally stratified plasma embedded in a parallel, so called vertical, magnetic field. We find a governing equation for the auxiliary quantity Θ = p {sub 1}/ ρ {sub 0}, and find solutions in terms of hypergeometric functions. With the convenient relationship between Θ and the vertical velocity component, v {sub z}, we derive the solution for v{sub z}. We show that the four linearly independent functions for v{sub z} can also be cast as single hypergeometric functions, rather than the Frobenius series derived by Leroy and Schwartz. We are then able to analyze a case of approximation for a one-layer solution, taking the small wavelength limit. Motivated by solar atmospheric applications, we finally commence study of the eigenmodes of perturbations for a two-layer model using our solutions, solving the dispersion relation numerically. We show that, for a transition between a photospheric and chromospheric plasma embedded in a vertical magnetic field, modes exist that are between the observationally widely investigated three and five minute oscillation periods, interpreted as solar global oscillations in the lower solar atmosphere . It is also shown that, when the density contrast between the layers is large (e.g., applied to photosphere/chromosphere-corona), the global eigenmodes are practically a superposition of the same as in each of the separate one-layer systems.

79 ASTRONOMY AND ASTROPHYSICS↗

A new and inexpensive non-bit-for-bit solution reproducibility test based on time step convergence (TSC1.0)

A test procedure is proposed for identifying numerically significant solution changes in evolution equations used in atmospheric models. The test issues a fail signal when any code modifications or computing environment changes lead to solution differences that exceed the known time step sensitivity of the reference model. Initial evidence is provided using the Community Atmosphere Model (CAM) version 5.3 that the proposed procedure can be used to distinguish rounding-level solution changes from impacts of compiler optimization or parameter perturbation, which are known to cause substantial differences in the simulated climate. The test is not exhaustive since it does not detect issues associated with diagnostic calculations that do not feedback to the model state variables. Nevertheless, it provides a practical and objective way to assess the significance of solution changes. The short simulation length implies low computational cost. The independence between ensemble members allows for parallel execution of all simulations, thus facilitating fast turnaround. The new method is simple to implement since it does not require any code modifications. We expect that the same methodology can be used for any geophysical model to which the concept of time step convergence is applicable.

54 ENVIRONMENTAL SCIENCES↗

A digital twin solution for floating offshore wind turbines validated using a full-scale prototype

Abstract. In this work, we implement, verify, and validate a physics-based digital twin solution applied to a floating offshore wind turbine. The digital twin is validated using measurement data from the full-scale TetraSpar prototype. We focus on the estimation of the aerodynamic loads, wind speed, and section loads along the tower, with the aim of estimating the fatigue lifetime of the tower. Our digital twin solution integrates (1) a Kalman filter to estimate the structural states based on a linear model of the structure and measurements from the turbine, (2) an aerodynamic estimator, and (3) a physics-based virtual sensing procedure to obtain the loads along the tower. The digital twin relies on a set of measurements that are expected to be available on any existing wind turbine (power, pitch, rotor speed, and tower acceleration) and motion sensors that are likely to be standard measurements for a floating platform (inclinometers and GPS sensors). We explore two different pathways to obtain physics-based models: a suite of dedicated Python tools implemented as part of this work and the OpenFAST linearization feature. In our final version of the digital twin, we use components from both approaches. We perform different numerical experiments to verify the individual models of the digital twin. In this simulation realm, we obtain estimated damage equivalent loads of the tower fore–aft bending moment with an accuracy of approximately 5 % to 10 %. When comparing the digital twin estimations with the measurements from the TetraSpar prototype, the errors increased to 10 %–15 % on average. Overall, the accuracy of the results is promising and demonstrates the possibility of using digital twin solutions to estimate fatigue loads on floating offshore wind turbines. A natural continuation of this work would be to implement the monitoring and diagnostics aspect of the digital twin to inform operation and maintenance decisions. The digital twin solution is provided with examples as part of an open-source repository.

17 WIND ENERGY↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Thermodynamics of rock forming crystalline solutions

Analysis of phase diagrams and cation distributions within crystalline solutions as means of obtaining thermodynamic data on rock forming crystalline solutions is discussed along with some aspects of partitioning of elements in coexisting phases. Crystalline solutions, components in a silicate mineral, and chemical potentials of these components were defined. Examples were given for calculating thermodynamic mixing functions in the CaW04-SrW04, olivine-chloride solution, and orthopyroxene systems.

Saxena, S. K.↗