Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “software estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Resolving local ambiguity using semantics of shape.

We demonstrate a new semantic method for automatic analysis of wide-area, high-resolution overhead imagery to tip and cue human intelligence analysts to human activity. In the open demonstration, we find and trace cars and rooftops. Our methodology, extended to analysis of voxels, may be applicable to understanding morphology and to automatic tracing of neurons in large-scale, serial-section TEM datasets. We defined an algorithm and software implementation that efficiently finds all combinations of image blobs that satisfy given shape semantics, where image blobs are formed as a general-purpose, first step that 'oversegments' image pixels into blobs of similar pixels. We will demonstrate the remarkable power (ROC) of this combinatorial-based work flow for automatically tracing any automobiles in a scene by applying semantics that require a subset of image blobs to fill out a rectangular shape, with width and height in given intervals. In most applications we find that the new combinatorial-based work flow produces alternative (overlapping) tracings of possible objects (e.g. cars) in a scene. To force an estimation (tracing) of a consistent collection of objects (cars), a quick-and-simple greedy algorithm is often sufficient. We will demonstrate a more powerful resolution method: we produce a weighted graph from the conflicts in all of our enumerated hypotheses, and then solve a maximal independent vertex set problem on this graph to resolve conflicting hypotheses. This graph computation is almost certain to be necessary to adequately resolve multiple, conflicting neuron topologies into a set that is most consistent with a TEM dataset.

99 GENERAL AND MISCELLANEOUS↗

Compartment modeling of dynamic brain PET—The impact of scatter corrections on parameter errors

Purpose: The aim of this study was to investigate the effect of scatter and its correction on kinetic parameters in dynamic brain positron emission tomography (PET) tumor imaging. The 2-tissue compartment model was used, and two different reconstruction methods and two scatter correction (SC) schemes were investigated. Methods: The GATE Monte Carlo (MC) software was used to perform 2 × 15 full PET scan simulations of a voxelized head phantom with inserted tumor regions. The two sets of kinetic parameters of all tissues were chosen to represent the 2-tissue compartment model for the tracer 3′-deoxy-3′-({sup 18}F)fluorothymidine (FLT), and were denoted FLT{sub 1} and FLT{sub 2}. PET data were reconstructed with both 3D filtered back-projection with reprojection (3DRP) and 3D ordered-subset expectation maximization (OSEM). Images including true coincidences with attenuation correction (AC) and true+scattered coincidences with AC and with and without one of two applied SC schemes were reconstructed. Kinetic parameters were estimated by weighted nonlinear least squares fitting of image derived time–activity curves. Calculated parameters were compared to the true input to the MC simulations. Results: The relative parameter biases for scatter-eliminated data were 15%, 16%, 4%, 30%, 9%, and 7% (FLT{sub 1}) and 13%, 6%, 1%, 46%, 12%, and 8% (FLT{sub 2}) for K{sub 1}, k{sub 2}, k{sub 3}, k{sub 4}, V{sub a}, and K{sub i}, respectively. As expected, SC was essential for most parameters since omitting it increased biases by 10 percentage points on average. SC was not found necessary for the estimation of K{sub i} and k{sub 3}, however. There was no significant difference in parameter biases between the two investigated SC schemes or from parameter biases from scatter-eliminated PET data. Furthermore, neither 3DRP nor OSEM yielded the smallest parameter biases consistently although there was a slight favor for 3DRP which produced less biased k{sub 3} and K{sub i} estimates while OSEM resulted in a less biased V{sub a}. The uncertainty in OSEM parameters was about 26% (FLT{sub 1}) and 12% (FLT{sub 2}) larger than for 3DRP although identical postfilters were applied. Conclusions: SC was important for good parameter estimations. Both investigated SC schemes performed equally well on average and properly corrected for the scattered radiation, without introducing further bias. Furthermore, 3DRP was slightly favorable over OSEM in terms of kinetic parameter biases and SDs.

60 APPLIED LIFE SCIENCES↗

SU-G-206-11: The Effect of Table Height On CTDIvol and SSDE in CT Scanning: A Phantom Study

Purpose: Localizer projection radiographs acquired prior to CT scans are used to estimate patient size, affecting the function of Automatic Tube Current Modulation (ATCM) and calculation of the Size Specific Dose Estimate (SSDE). Due to geometric effects, the projected patient size varies with scanner table height and with the orientation of the localizer (AP versus PA). Consequently, variations in scanner table height may affect both CTDIvol and the calculated size-corrected dose index (SSDE). This study sought to characterize these effects. Methods: An anthropomorphic phantom was imaged using an AP localizer, followed by a diagnostic scan using ATCM and our institution’s routine abdomen protocol. This was repeated at various scanner table heights, recording the scanner-reported CTDIvol for each diagnostic scan. The width of the phantom was measured from the localizer and diagnostic images using in-house software. The measured phantom width and scanner-reported CTDIvol were used to calculate SSDE. This was repeated using PA localizers followed by diagnostic scans. Results: 1) The localizer-based phantom width varied by up to 54% of the nominal phantom width between minimum and maximum table heights. 2) Changing the table height caused a variation in scanner-reported CTDIvol of a factor greater than 4.6 when using a PA localizer and almost 2 when using an AP localizer. 3) SSDE, calculated from measured phantom size and scanner-reported CTDIvol, varied by a factor of more than 2.8 when using a PA localizer and almost 1.5 when using an AP localizer. Conclusion: Our study demonstrates that off-center patient positioning affects the efficacy of ATCM, more severely when localizers are acquired in the PA rather than AP projection. Further, patient positioning errors can cause a large variation in the calculated SSDE. This hinders interpretation of SSDE for individual patients and aggregate SSDE data when evaluating CT protocols and clinical practices.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP1-13: Innovative Tracking Detector for Dose Monitoring in Hadron Therapy: Realization and Monte Carlo Simulations

Purpose: Development of strategies to monitor range uncertainties is necessary to improve treatment planning in Charged Particle Therapy (CPT) and fully exploit the advantages of ion beams. Our group developed (within the framework of the INSIDE project funded by the Italian research ministry) and is currently building a compact detector Dose Profiler (DP) able to backtrack charged secondary particles produced in the patient during the irradiation. Furthermore we are studying monitoring strategy exploiting charged secondary emission profiles to control the range of the ion beam. Methods: This contribution reports on the DP detector design and construction status. The detector consists of a charged secondary tracker composed of scintillating fiber layers and a LYSO calorimeter for particles energy measurement.The detector layout has been optimized using the FLUKA Monte Carlo (MC) simulation software. The simulation of a 220 MeV Carbon beam impinging on a PMMA target has been performed to study the detector response, exploiting previous secondary radiation measurements performed by our group. The emission profile of charged secondary particles was reconstructed backtracking the particles to their generation point to benchmark the DP performances. Results: The DP construction status, including the technological details will be presented. The feasibility of range monitoring with DP will be demonstrated by means of MC studies. The correlation of the charged secondary particles emission shape with the position of the Bragg peak (BP) will be shown, as well as the spatial resolution achievable on the BP position estimation (less than 3 mm) in the clinical like conditions. Conclusion: The simulation studies supported the feasibility of an accurate range monitoring technique exploiting the use of charged secondary fragments emitted during the particle therapy treatment. The DP experimental tests are foreseen in 2016, at CNAO particle therapy center in Pavia.

60 APPLIED LIFE SCIENCES↗

Algorithm and program for precise determination of unit-cell parameters of single crystal taking into account the sample eccentricity

A technique has been developed to refine the unit-cell parameters of single crystals with minimization of the influence of instrumental errors on the result. The corresponding computational procedure HuberUB is added to the software package of Huber-5042 diffractometer with a point detector and closedcycle helium cryostat Displex DE-202. The parameters of unit cell, its orientation, the goniometer zero angles, the sample eccentricity, the distances in the goniometer, and the radiation wavelength were refined by the nonlinear least-squares method, which allows imposition of constraints on the unit-cell parameters, depending on the crystal symmetry. The technique is approved on a LuB{sub 12} single crystal. The unit-cell parameters are determined in a temperature range of 20–295 K, with an absolute error not larger than 0.0004 Å (the relative error is of ~5 × 10{sup –5}). The estimates of the unit-cell parameters obtained by the proposed method are evidenced to be unbiased. Some specific features of the behavior of parameters in the ranges of 120–140 and 20–50 K are revealed, which correlate with the anomalies of the physical properties of the crystal.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

FARM User Guidance and Instructions

The FARM (Feasible Actuator Range Modifier) module is a component of the RAVEN-based FORCE framework for the analysis of Integrated Energy Systems (IES). FARM aids HERON in the solution of the power dispatch problem by evaluating feasible set-point signals to be issued to the control systems of the different IES unit components. Set-points need to satisfy limits on both production variables (i.e., the variables to be optimized such as the electrical power, etc.) and process variables tied to the service life of equipment (e.g., steam flowrate, vessel pressure, turbine firing temperature, etc.). To enforce all these limits, a two-stage approach is adopted. First, the power dispatcher algorithm in HERON module estimates set-points that meet the constraints on the production variables, e.g., power levels and power ramp rate limits. These constraints are called explicit constraints. Then, if necessary, FARM adjusts these set-points to ensure the respect of the limits on the process variables of interest, given the knowledge of the system dynamics acquired through machine learning algorithms. These constraints are called implicit constraints. From this standpoint, FARM constitutes a bridge between the HERON power dispatcher that adopts a simplified description of the IES unit (low-resolution physics) and the HYBRID high-fidelity models (high-resolution physics). In this report, the general workflow and the software requirements of FARM module are summarized, and the detailed instructions for installing FARM software, running built-in example cases, deriving Linear Parameter-Varying (LPV) state-space models, and using FARM for user-defined power dispatch problems are provided.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Atacama Cosmology Telescope: DR6 Sunyaev-Zel'dovich Selected Galaxy Clusters Catalog

We present the results of a search for galaxy clusters in the Atacama Cosmology Telescope (ACT) Data Release 6 (DR6) microwave sky maps covering 16293 square degrees in three frequency bands, using data obtained over the lifetime of the project (2008-2022). We report redshifts and mass estimates for 10040 clusters detected via their Sunyaev-Zel'dovich (SZ) effect with signal-to-noise greater than 4 at a 2.4 arcminute filter scale. The catalog includes 1180 clusters at redshifts greater than 1, and 124 clusters at redshifts greater than 1.5. Using a relation between cluster SZ signal and mass that is consistent with recent weak-lensing measurements, we estimate that clusters detected with signal-to-noise greater than 5 form a sample which is 90% complete for clusters with masses greater than $5 \times 10^{14}$ MSun (measured within a spherical volume with mean density 500 times the critical density). El Gordo, a cluster found in an initial ACT survey of 755 square degrees, remains the most extreme cluster in mass and redshift; we find no cluster with a mass and redshift combination high enough to falsify the standard LCDM cosmology with Gaussian initial perturbations. We make public a variety of data products, including the full cluster candidate list, noise maps, and sky masks, along with our software for cluster detection and instructions for reproducing our cluster catalogs from the public ACT maps.

Aguena, M. [Trieste Observ.; LIneA, Rio de Janeiro↗

A complex approach to assessing porous structure of structured ceramics obtained by SPS technique

Highlights: • A complex approach to microstructural analysis of nanostructured SPS ceramics was presented. • A bunch of gas, intrusion and microscopic methods were applied for open/closed porosity determination in nanoceramics. • Kinetic TPR analysis for structural changes in nanoceramic was carried out. • 3D pore visualization for nanoceramics was provided via SEM/FIB tomography • Porosity calculations were performed via BET, BJH, t-plot, Washburn equation, FEI Avizo 9.1 software results. - Abstract: Spark plasma sintering (SPS) is a highly prospective technology providing rapid consolidation of nano-disperse compositions into structured ceramics with complex structural organization. Characterizing pore structure of such systems remains a challenge due to different types, size and shape of the pores as well as structural defects occurring in the material, thus requiring special methods to quantify certain porosity type. The paper presents a complex approach to studying structure of SPS hematite-based structured ceramics. The method involves a number of gas, intrusion and electron microscopy probing techniques to characterize open and closed pores in the ceramics bulk. Low temperature nitrogen sorption has been implemented to estimate open micro- and mesoporosity in the size range 0.7–50 nm using BET, BJH and t-plot methods to process experimental data. Additionally, structural peculiarities of consolidated structured ceramics have been studied using temperature-programmed reduction (TPR) with the kinetic analysis of the results being carried out. Volume of macropores sized above 50 nm has been measured with mercury intrusion. Closed pores and structural defects have been quantified with SEM and FIB/SEM tomography. By comparing experimental and estimated results we have shown that addressing all porosity types provides a highly precise structural characterization of the material.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A high-throughput pipeline for designing microarray-based pathogen diagnostic assays

fingerprints for microarray-based pathogen diagnostic assays. The oligonucleotide fingerprints, or DNA microarray probes, are designed for identifying target organisms in environmental or clinical samples. The design process is implemented in a high-performance computing software pipeline that incorporates major algorithmic improvements over a previous version to both reduce computation time and improve specificity assessment. Results: The algorithmic improvements result in significant reduction in runtimes, with the updated pipeline being nearly up to five-times faster than the previous version. The improvements in specificity assessment, based on multiple specificity criteria, result in robust and consistent evaluation of cross-hybridization with nontarget sequences. In addition, the multiple criteria provide finer control on the number of resulting fingerprints, which helps in obtaining a larger number of fingerprints with high specificity. Simulation tests for Francisella tularensis and Yersinia pestis, using a well-established hybridization model to estimate cross-hybridization with nontarget sequences, show that the improved specificity criteria yield a larger number of fingerprints as compared to using a single specificity criterion. Conclusion: The faster runtimes, achieved as the result of algorithmic improvements, are critical for extending the pipeline to process multiple target genomes. The larger numbers of identified fingerprints, obtained by considering broader specificity criteria, are essential for designing probes for hard-to-distinguish target sequences.

59 BASIC BIOLOGICAL SCIENCES↗

Bridging the time scale in exascale computing of chemical systems (Final Technical Report)

This report summarizes the work carried out with support of the United States Department of Energy under Award DE-SC0019441. The theme of this project was to develop and apply methods that allowed for the acceleration of atomistic calculations, particularly in challenging areas such as multiphase systems, electrified interfaces, uncertainty estimation, and applications requiring chemical accuracy, which tend to be applications where simulation time is severely bottlenecked by the computational time requirements. Much of the focus was on the application of emerging machine-learning methodologies, although a wide range of methodologies were employed. This report has two major sections. The first focuses on the methodological advances themselves. Within this part, we report a number of major advances, a few examples of which are described here. We report the first machine-learning scheme for the acceleration of electronically grand-canonical calculations (that is, those applicable to electrochemistry). We report new methods of performing transfer learning, in which physics-based priors can be used to provide predictions, often with uncertainty estimates, of images well outside of training sets; we also offer ways to fine-tune these transfer-learning models. We provide a new systematic means to generate and apply minimal training data sets to very large (10,000’s of atoms) systems, with only small training sets appropriate for electronic structure. We developed new methodologies to integrate surface vibrations into surface adsorption calculations. We made advances to the applicability of diffusion Monte Carlo methods to allow (learned) force prediction, finite-size error correction, and force-free means of searching for transition states. We integrated machine-learned atomistic predictions into mechanism generation codes. Additionally, we released new software including AmpTorch, a modernized version of our original atomistic machine-learning code Amp. The second part of this report focuses on the scientific applications that accompanied, and were often enabled by, the methodological advances described earlier. A few examples follow, but full details are in the individual chapters of the report. For example, we developed a general theory of phonon-induced friction on molecular adsorbates. We showed fundamentally how solvent influences the adsorption and desorption process and how it differs from the processes typically involved at the solid–gas interface, making aqueous-phase and electrocatalysis different from traditional thermocatalysis. We examined how metal–insulator and magnetic transitions can be probed, and accelerated exciton dynamics via Frenkel Hamiltonian parameters. We showed that the nearsighted force-training approach, developed within this project, can predict both the stability and reactivity of large nanoparticles, and can also lead to insights on catalyst coverage on binding energies and entropies. These applied studies, which generally integrated with our method development, allowed us to push forward the theoretical understanding of several reaction classes.

08 HYDROGEN↗

Intern Poster

Digital Image Correlation (DIC) is an optical technique that combines image registration and tracking methods for accurate two-dimensional and three-dimensional changes in images. DIC software can be used to track the contour, deformation, and strain of a sample. In the Advanced Test Reactor (ATR) at INL (Idaho National Laboratory) there exists a small working window of samples that can become irradiated. Hundreds of graphite disks called piggybacks have undergone this irradiation as part of the Advanced Reactor Technologies (ART) program. After irradiation, it is desirable to understand the change in tensile strength as a function of dose. Due to the limited space in the ATR, typical dog bone tensile tests reduce the number of graphite samples from hundreds to tens. However, there does exist an ASTM standard, D8289, which uses disc compression of graphite to estimate the tensile strength of the specimen with the Brazilian Disk test fixture. While only used as an estimate, which is typically off by a third, it is the purpose of this study to identify how to amend D8289 to remove the word "estimate" with the help of DIC.

36 MATERIALS SCIENCE↗

Evaluation of Radiation Dose and Image Quality for the Varian Cone Beam Computed Tomography System

Purpose: To compare the image quality and dosimetry on the Varian cone beam computed tomography (CBCT) system between software Version 1.4.13 and Version 1.4.11 (referred to as 'new' and 'old' protocols, respectively, in the following text). This study investigated organ absorbed dose, total effective dose, and image quality of the CBCT system for the head-and-neck and pelvic regions. Methods and Materials: A calibrated Farmer chamber and two standard cylindrical Perspex CT dosimetry phantoms with diameter of 16 cm (head phantom) and 32 cm (body phantom) were used to measure the weighted cone-beam computed tomography dose index (CBCTDIw) of the Varian CBCT system. The absorbed dose of different organs was measured in a female anthropomorphic phantom with thermoluminescent dosimeters (TLD) and the total effective dose was estimated according to International Commission on Radiological Protection (ICRP) Publication 103. The dose measurement and image quality were studied for head-and-neck and pelvic regions, and comparison was made between the new and old protocols. Results: The values of the new CBCTDIw head-and-neck and pelvic protocols were 36.6 and 29.4 mGy, respectively. The total effective doses from the new head-and-neck and pelvic protocols were 1.7 and 8.2 mSv, respectively. The absorbed doses of lens for the new 200{sup o} and old 360{sup o} head-and-neck protocols were 3.8 and 59.4 mGy, respectively. The additional secondary cancer risk from daily CBCT might be up to 2.8%. Conclusions: The new Varian CBCT provided volumetric information for image guidance with acceptable image quality and lower radiation dose. This imaging tool gave a better standard for patient daily setup verification.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

eDNAjoint: An R package for interpreting paired or semi‐paired environmental DNA and traditional survey data in a Bayesian framework

Abstract Environmental DNA (eDNA) sampling is increasingly used in surveys of species distribution as a potentially sensitive and efficient monitoring method. Yet access to modelling tools designed specifically for interpreting this new data type lags behind its ubiquity. While occupancy modelling software has dominated the analytical landscape for eDNA data analysis of single species, this type of model may not always be the most appropriate. The rate of eDNA detection often corresponds to species density, rather than just occupancy, and researchers often have access to observations from non‐genetic sampling methods at the same sites. To provide users access to a modelling framework designed to maximize the use of all available data, we developed an R package, eDNAjoint . The package provides an easy‐to‐use interface for fitting a ‘joint’ model that integrates data from paired or semi‐paired eDNA and traditional surveys in a Bayesian framework. The model can be used to estimate parameters like the probability of a false positive eDNA detection and mean catch rate at a site, and the package allows access to multiple model variations and Bayesian prior customization. Additional functionality can be used for model selection, summarising posteriors and comparing the relative sensitivities of the two survey methods. We demonstrate the use of eDNAjoint by fitting a variation of the model with site‐level covariates that scale the sensitivity of eDNA sampling relative to traditional sampling. The example workflow uses binary eDNA and seine count data for the endangered tidewater goby ( Eucyclogobius newberryi ) from a study by Schmelzle and Kinziger (2016). This use case includes a prior sensitivity analysis and an evaluation of the relationship between detection rates and environmental variables. eDNAjoint has the potential to greatly increase the range of users who will be able to rigorously analyse eDNA and traditional survey data in a Bayesian framework, understand if and how eDNA can improve monitoring practices, and gain confidence in the interpretability of eDNA data.

Keller, Abigail G. [Department of Environment Scie↗

An optimized model and test of the China's first high temperature parabolic trough solar receiver

The vacuum solar receiver is the key component of a parabolic trough solar plant, which plays a prominent role in the gross system efficiency. Recently, China's first high temperature vacuum receiver, Sanle-3 HCE, has been developed and produced by Southeast University and Sanle Electronic Group. Before being utilized in China's first parabolic trough solar plant, accurately estimating the thermal properties of this new receiver is important. This paper first establishes and optimizes a 1-D theoretical model at Matlab program to compute the receiver's major heat loss through glass envelope, and then systematically analyzes the major influence factors of heat loss. With the laboratorial steady state test stand, the heat losses of both good vacuum and non-vacuum Sanle-3 receivers were surveyed. Comparison shows the original 1-D model agrees with the ends covered test while remarkably deviating from end exposed test. For the purpose of identifying the influence of receiver's end to total heat loss, an additional 3-D model is built by CFD software to further investigate the different heat transfer processes of receiver's end components. The 3-D end model is verified by heating power and IR temperature distribution images in the test. Combining the optimized 1-D model with the new 3-D end model, the comparison with test data shows a good accordance. At the same time the heat loss curve and emittance curve of this new receiver are given and compared with those of several other existing receivers as references. (author)

14 SOLAR ENERGY↗

NUTRON NESHAPs Dashboard

My project aims to enhance the Nuclear Material Tracking Application (NUTRON) software by integrating a tool for the National Emission Standards for Hazardous Air Pollutants (NESHAP) emissions calculations and presenting this data on a dashboard. Inefficiencies in the current NESHAP calculation process were addressed, which will result in more timely regulatory compliance efforts. Key improvements include revising the transfer request system, incorporating effective dose calculations, and developing a data visualization dashboard into NUTRON. The project involved creating a wireframe, preparing an Engineering Calculations and Analysis Report (ECAR), stakeholder meetings, and providing supplemental documentation. Key findings indicate that the proposed modifications will streamline the NESHAP calculation process, reduce human error, and provide REC personnel with accurate and timely data for material use determinations and dose estimations. Future work focuses on completing the NUTRON modifications and fully integrating the new features, ensuring a more efficient and reliable system for tracking and reporting nuclear material transfers.

99 - GENERAL AND MISCELLANEOUS↗

A second‐generation virtual‐pinhole PET device for enhancing contrast recovery and improving lesion detectability of a whole‐body PET/CT scanner

Purpose We have developed a second‐generation virtual‐pinhole (VP) positron emission tomography (PET) device that can position a flat‐panel PET detector around a patient's body using a robotic arm to enhance the contrast recovery coefficient (CRC) and detectability of lesions in any region‐of‐interest using a whole‐body PET/computed tomography (CT) scanner. Methods We constructed a flat‐panel VP‐PET device using 32 high‐resolution detectors, each containing a 4 4 MPPC array and 16 16 LYSO crystals of 1.0 1.0 3.0 mm 3 each. The flat‐panel detectors can be positioned around a patient's body anywhere in the imaging field‐of‐view (FOV) of a Siemens Biograph 40 PET/CT scanner by a robotic arm. New hardware, firmware and software have been developed to support the additional detector signals without compromising a scanner's native functions. We stepped a 22 Na point source across the axial FOV of the scanner to measure the sensitivity profile of the VP‐PET device. We also recorded the coincidence events measured by the scanner detectors and by the VP‐PET detectors when imaging phantoms of different sizes. To assess the improvement in the CRC of small lesions, we imaged an elliptical torso phantom measuring 316 228 162 mm 3 that contains spherical tumors with diameters ranging from 3.3 to 11.4 mm with and without the VP‐PET device. Images were reconstructed using a list mode Maximum‐Likelihood Estimation‐Maximization algorithm implemented on multiple graphics processing units (GPUs) to support the unconventional geometries enabled by a VP‐PET system. The mean and standard deviation of the CRC were calculated for tumors of different sizes. Monte Carlo simulation was also conducted to image clusters of lesions in a torso phantom using a PET/CT scanner alone or the same scanner equipped with VP‐PET devices. Receiver operating characteristic (ROC) curves were analyzed for three system configurations to evaluate the improvement in lesion detectability by the VP‐PET device over the native PET/CT scanner. Results The repeatability in positioning the flat‐panel detectors using a robotic arm is better than 0.15 mm in all three directions. Experimental results show that the average CRC of 3.3, 4.3, and 6.0 mm diameter tumors was 0.82%, 2.90%, and 5.25%, respectively, when measured by the native scanner. The corresponding CRC was 2.73%, 6.21% and 10.13% when imaged by the VP‐PET insert device with the flat‐panel detector under the torso phantom. These values may be further improved to 4.31%, 9.65% and 18.01% by a future dual‐panel VP‐PET insert device if DOI detectors are employed to triple its detector efficiency. Monte Carlo simulation results show that the tumor detectability can be improved by a VP‐PET device that has a single flat‐panel detector. The improvement is greater if the VP‐PET device employs a dual‐panel design. Conclusions We have developed a prototype flat‐panel VP‐PET device and integrated it with a clinical PET/CT scanner. It significantly enhances the contrast of lesions, especially for those that are borderline detectable by the native scanner, within regions‐of‐interest specified by users. Simulation demonstrated the enhancement in lesion detectability with the VP‐PET device. This technology may become a cost‐effective solution for organ‐specific imaging tasks.

Jiang, Jianyong↗

Estimation of Anthocyanin Content of Berries by NIR Method

Anthocyanin contents of fruits were estimated by VIS spectrophotometer and compared with spectra measured by NIR spectrophotometer (600-1100 nm step 10 nm). The aim was to find a relationship between NIR method and traditional spectrophotometric method. The testing protocol, using NIR, is easier, faster and non-destructive. NIR spectra were prepared in pairs, reflectance and transmittance. A modular spectrocomputer, realized on the basis of a monochromator and peripherals Bentham Instruments Ltd (GB) and a photometric camera created at Canning Research Institute, were used. An important feature of this camera is the possibility offered for a simultaneous measurement of both transmittance and reflectance with geometry patterns T0/180 and R0/45. The collected spectra were analyzed by CAMO Unscrambler 9.1 software, with PCA, PLS, PCR methods. Based on the analyzed spectra quality and quantity sensitive calibrations were prepared. The results showed that the NIR method allows measuring of the total anthocyanin content in fresh berry fruits or processed products without destroying them.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design of a Particle Shadow-graph Velocimetry and Size (PSVS) System to Determine Particle Size and Density Distributions in Hanford Nuclear Tank Wastes - 12280

Accurate particle size and density distributions for nuclear tank waste materials are essential information that helps determine the engineering requirements for a host of waste management unit operations (e.g., tank mixing, pipeline transport, and filtration). The most prevalent approach for determining particle size and density distribution is highly laborious and involves identifying individual particles using scanning electron microscope/x-ray diffraction and then acquiring the density of the materials from the technical literature. Other methods simply approximate individual particle densities by assuming chemical composition, rather than obtaining actual measurements of particle density. To overcome these limitations, a Particle Shadow-graph Velocimetry and Size (PSVS) system has been designed to simultaneously obtain particle size and density distributions for a broad range of Hanford tank waste materials existing as both individual particles and agglomerates. The PSVS system uses optical hardware, a temperature-controlled settling column, and particle introduction chamber to accurately and reproducibly obtain images of settling particles. Image analysis software provides a highly accurate determination of both particle terminal velocity and equivalent spherical particle diameter. The particle density is then calculated from Newton's terminal settling theory. The PSVS system was designed to accurately image particle/agglomerate sizes between 10 and 1000 μm and particle/agglomerate densities ranging from 1.4 to 11.5 g/cm{sup 3}, where the maximum terminal velocity does not exceed 10 cm/s. Preliminary testing was completed with standard materials and results were in good agreement with terminal settling theory. Recent results of this method development are presented, as well as experimental design. The primary goal of these PSVS system tests was to obtain accurate and reproducible particle size and velocity measurements to estimate particle densities within 20 percent of direct measured density values. The average percent error observed in particle densities was 4.8, 8.2, and 25.8 percent for S1D3 (high-density soda-lime glass), S3D4 (zirconia), and S1D2 (soda-lime glass) beads, respectively. The maximum measured particle density error observed was 14.5, 21.0, and 58.4, for S1D3, S3D4, and S1D2 beads, respectively. Multiple sources of error can exist that contribute to inaccurate estimates of particle density using the PSVS approach. Two significant influences observed were thermal convective currents in the settling column fluid and non-spherical (irregular) particle shapes in the standard test materials. Experimental results using buoyant beads suggest thermal convective currents can influence the movement of settling particles as much as 4 mm/s. These thermal convective currents are clearly a significant concern for smaller and less-dense particles/agglomerates which have terminal velocities of the same magnitude. Significant effort went into the design and fabrication of a thermal control system for the PSVS settling column. However, small temperature variations (<0.3 deg. C) are difficult to prevent and measure accurately. Therefore, although designing the thermal control system was necessary, it is not considered the only solution to minimize error due to thermal convective currents. The use of small diameter (10 to 27 μm) polyethylene buoyant beads (in low concentrations) during actual settling experiments may be necessary to provide insight into particle-particle interactions and fluid velocity correction factors to account for potential influences from thermal convective currents. Future testing will incorporate the buoyant beads into the analysis technique when the suspension fluid is chemically compatible. The use of the Newton's law to calculate particle/agglomerate densities assumes spherical particle shapes. As the actual particle/agglomerates diverge from spherical, the margin of error increases. The selection of high quality (in density and shape) monodispersed particle standards was a direct attempt to reduce the uncertainties associated with non-spherical or irregular particles and to only observe the PSVS method and analysis error. While investigating the source of data scatter for the S1D3 bead (nominal 700 μm) standard, significant irregular particles where discovered. Yet, a subsequent investigation into the S3D4 bead standard was also conducted and it was determined that 60 percent of the particles had a 0.9 to 0.8 centricity, 32 percent were between 0.8 and 0.7, only 7 percent were between 1.0 and 0.9, and the remaining 1 percent of the particles had centricities between 0.7 and 0.6. Contrast this with the S1D3 bead standard, where 100 percent of particles had centricities between 0.95 and 0.98, upon applying the centricity filter. The influence of the non-spherical shape of the S3D4 bead standard is evident when comparing a 3.9 percent average density error for S1D3 glass bead standard with an 8.3 percent average density error for the S3D4 bead standard. Model corrections for non-spherical shape must be implemented to account for these measurement errors during future method validation and system performance assessments. In addition, further work is needed to resolve the higher than expected velocities for the smaller S1D2 particles. Initial measurements conducted with buoyant beads as fluid velocity tracers indicate that fluid velocities can be subtracted from the increased particle velocities to determine the particle terminal velocity, regardless of the surrounding fluid velocity. However, this approach is in its infancy and will need to be carefully and methodically validated. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗