Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “shape optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Temperature dependent localized surface plasmon resonance properties of supported gold nanoparticles

The well known localized surface plasmon resonance (LSPR) of gold nanoparticles (AuNPs) supported on a dielectric substrate depends on the particle shape, size and type of dielectric material. The particle size and shape mainly vary with the method of preparation and the parameters involved there in. In this report, we show preparation of AuNPs supported on quartz substrate by direct current sputtering followed by thermal annealing at an optimized temperature of 400 °C. The samples were characterized using optical absorption spectra, scanning electron microscopy (SEM) and the energy dispersive x-ray spectrum. The LSPR position could be tuned by varying annealing temperature. The LSPR was found to be blue shifted up to 10 nm with annealing temperature varying from 400 °C to 800 °C. The change in LSPR was ascribed to the morphology of AuNPs over quartz.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Ultra-high wear resistance of ultra-nanocrystalline diamond film: Correlation with microstructure and morphology

Nanostructured diamond films are having numerous unique properties including superior tribological behavior which is promising for enhancing energy efficiency and life time of the sliding devices. High wear resistance is the principal criterion for the smooth functioning of any sliding device. Such properties are achievable by tailoring the grain size and grain boundary volume fraction in nanodiamond film. Ultra-nanocrystalline diamond (UNCD) film was attainable using optimized gas plasma condition in a microwave plasma enhanced chemical vapor deposition (MPECVD) system. Crystalline phase of ultra-nanodiamond grains with matrix phase of amorphous carbon and short range ordered graphite are encapsulated in nanowire shaped morphology. Film showed ultra-high wear resistance and frictional stability in micro-tribological contact conditions. The negligible wear of film at the beginning of the tribological contact was later transformed into the wearless regime for prolonged sliding cycles. Both surface roughness and high contact stress were the main reasons of wear at the beginning of sliding cycles. However, the interface gets smoothened due to continuous sliding, finally leaded to the wearless regime.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

High-Fidelity Adiabatic Passage by Composite Sequences of Chirped Pulses

We present a method for optimization of the technique of adiabatic passage between two quantum states by composite sequences of frequency-chirped pulses with specific relative phases: composite adiabatic passage (CAP). By choosing the composite phases appropriately the nonadiabatic losses can be canceled to any desired order with sufficiently long sequences, regardless of the nonadiabatic coupling. The values of the composite phases are universal for they do not depend on the pulse shapes and the chirp. The accuracy of the CAP technique and its robustness against parameter variations make CAP suitable for high-fidelity quantum information processing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-542: Comparison of Stereotactic Radiosurgery (SRS) of Brain Lesions Using Gamma Knife, VMAT, IMRT, and Conformal Arcs

Purpose: To compare dose distributions in stereotactic radiation surgery of brain lesions using gamma Knife, VMAT, conformal arcs, and IMRT in order to provide an optimal treatment. Methods: Dose distributions from single shot of 4C model of Gamma Knife at the helmet collimation sizes of 4, 8, 14, and 18 mm in diameter were compared with full arcs with the square shapes of 4×4 (or 5×5), 8×8 (or 10×10), and spherical shapes of 16 or 20 mm in diameter using EDR3 films in the same gamma knife QA phantom. Plans for ten SRS cases with single and multiple lesions were created in gamma knife plans and Pinnacle plans. The external beam plans had enlarged field size by 2-mm and used single conformal full circle arc for solitary lesion and none coplanar arcs/beams for multiple lesions. Coverage, conformity index, dose to critical organs, and integral dose to the brain and nearby critical structures were compared on all plans. Structures and dose matrices were registered in a Velocity deformable image registration system. Results: Single full circle arc from Elekta beam-modulate MLC (4-mm leaf thickness) and agility MLC (5-mm leaf thickness) have larger penumbra and less flatness than that of Gamma Knife single shot. None-coplanar arcs or beams were required to achieve similar dose distribution. In general, Gamma Knife plans provided significant less integral dose than that of linac-based plans. Benefits of IMRT and VMAT versus gamma Knife and conformal arcs were not significant. Conclusion: Our dose measurement and treatment planning evaluation clearly demonstrated dose distribution differences amount current popular SRS modalities for small solitary and multiple brain lesions. The trend of using MLC shape beams or arcs to replace conventional cones should be revisited in order to keep lower integral dose if the late correlates with some radiation-induced side effects. Pilot grant from Elekta LLC.

60 APPLIED LIFE SCIENCES↗

Super-resolution within a one-dimensional phononic crystal of resonators using time reversal in an equivalent circuit model

An equivalent circuit model has been developed to model a one-dimensional waveguide with many side-branch Helmholtz resonators. This waveguide constitutes a phononic crystal that has been shown to have decreased phase speed below the resonance frequency of an individual resonator. This decreased phase speed can be exploited to achieve super-resolution using broadband time reversal focusing techniques. It is shown that the equivalent circuit model is capable of quantifying this change in phase speed of the crystal and also the small-scale wave-resonator interactions within the crystal. The equivalent circuit model enables the parameterization of the physical variables and the optimization of the focusing bandwidth by balancing the combination of increasing resolution and decreasing amplitude near the resonance frequency. It is shown that the quality factor—in this case, the quality factor determined by the geometric shape of each resonator—controls the range of frequencies that are strongly affected by the Helmholtz resonators.

Kingsley, Adam D.↗

INTEGRATE - Inverse Network Transformations for Efficient Generation of Robust Airfoil and Turbine Enhancements

The INTEGRATE (Inverse Network Transformations for Efficient Generation of Robust Airfoil and Turbine Enhancements) project is developing a new inverse-design capability for the aerodynamic design of wind turbine rotors using invertible neural networks. This AI-based design technology can capture complex non-linear aerodynamic effects while being 100 times faster than design approaches based on computational fluid dynamics. This project enables innovation in wind turbine design by accelerating time to market through higher-accuracy early design iterations to reduce the levelized cost of energy. INVERTIBLE NEURAL NETWORKS Researchers are leveraging a specialized invertible neural network (INN) architecture along with the novel dimension-reduction methods and airfoil/blade shape representations developed by collaborators at the National Institute of Standards and Technology (NIST) learns complex relationships between airfoil or blade shapes and their associated aerodynamic and structural properties. This INN architecture will accelerate designs by providing a cost-effective alternative to current industrial aerodynamic design processes, including: - Blade element momentum (BEM) theory models: limited effectiveness for design of offshore rotors with large, flexible blades where nonlinear aerodynamic effects dominate - Direct design using computational fluid dynamics (CFD): cost-prohibitive - Inverse-design models based on deep neural networks (DNNs): attractive alternative to CFD for 2D design problems, but quickly overwhelmed by the increased number of design variables in 3D problems AUTOMATED COMPUTATIONAL FLUID DYNAMICS FOR TRAINING DATA GENERATION - MERCURY FRAMEWORK The INN is trained on data obtained using the University of Marylands (UMD) Mercury Framework, which has with robust automated mesh generation capabilities and advanced turbulence and transition models validated for wind energy applications. Mercury is a multi-mesh paradigm, heterogeneous CPU-GPU framework. The framework incorporates three flow solvers at UMD, 1) OverTURNS, a structured solver on CPUs, 2) HAMSTR, a line based unstructured solver on CPUs, and 3) GARFIELD, a structured solver on GPUs. The framework is based on Python, that is often used to wrap C or Fortran codes for interoperability with other solvers. Communication between multiple solvers is accomplished with a Topology Independent Overset Grid Assembler (TIOGA). NOVEL AIRFOIL SHAPE REPRESENTATIONS USING GRASSMAN SPACES We developed a novel representation of shapes which decouples affine-style deformations from a rich set of data-driven deformations over a submanifold of the Grassmannian. The Grassmannian representation as an analytic generative model, informed by a database of physically relevant airfoils, offers (i) a rich set of novel 2D airfoil deformations not previously captured in the data , (ii) improved low-dimensional parameter domain for inferential statistics informing design/manufacturing, and (iii) consistent 3D blade representation and perturbation over a sequence of nominal shapes. TECHNOLOGY TRANSFER DEMONSTRATION - COUPLING WITH NREL WISDEM Researchers have integrated the inverse-design tool for 2D airfoils (INN-Airfoil) into WISDEM (Wind Plant Integrated Systems Design and Engineering Model), a multidisciplinary design and optimization framework for assessing the cost of energy, as part of tech-transfer demonstration. The integration of INN-Airfoil into WISDEM allows for the design of airfoils along with the blades that meet the dynamic design constraints on cost of energy, annual energy production, and the capital costs. Through preliminary studies, researchers have shown that the coupled INN-Airfoil + WISDEM approach reduces the cost of energy by around 1% compared to the conventional design approach. This page will serve as a place to easily access all the publications from this work and the repositories for the software developed and released through this pr...

aerodynamics↗

Installation and Testing of a Jorin Visual Process Analyzer

The Jorin Visual Process Analyzer (ViPA) is an on-line instrument that uses video microscope imaging to detect and measure the physical characteristics of dispersed objects within a process stream or laboratory sample. Object analysis is performed by capturing an on-going sequence of single frames from the video feed and relaying the images in real time to a nearby control computer where the ViPA software then processes and transfigures the information from the images into meaningful process data. The ViPA captures and analyzes approximately 15 images per second and continuously records 17 material parameters including size, shape and optical density. The ViPA software uses the measured parameters to differentiate between different classes of objects including organic droplets, gas bubbles, and solid particles. Procurement of this instrument provides a unique capability to support predictive modeling and further understanding of mass transfer during solvent extraction processes. Organic droplet data collected using the ViPA can be used to develop dispersion profiles of the liquid-liquid mixing and disengagements sections for each type of process equipment. These profiles will provide insight into mixing dynamics and will guide the prevention of emulsion formation that leads to system losses. Additionally, the measurement capabilities of the ViPA will provide the input needed to create new two-phase Computational Fluid Dynamics (CFD) models that characterize both mixing and separation operations in the various types of equipment. These models can then be used to improve process efficiency by optimizing operation parameters for each proposed extraction cycle.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Localized Overheating Phenomena and Optimization of Spark-Plasma Sintering Tooling Design

The present paper shows the application of a three-dimensional coupled electrical, thermal, mechanical finite element macro-scale modeling framework of Spark Plasma Sintering (SPS) to an actual problem of SPS tooling overheating, encountered during SPS experimentation. The overheating phenomenon is analyzed by varying the geometry of the tooling that exhibits the problem, namely by modeling various tooling configurations involving sequences of disk-shape spacers with step-wise increasing radii. The analysis is conducted by means of finite element simulations, intended to obtain temperature spatial distributions in the graphite press-forms, including punches, dies, and spacers; to identify the temperature peaks and their respective timing, and to propose a more suitable SPS tooling configuration with the avoidance of the overheating as a final aim. Electric currents-based Joule heating, heat transfer, mechanical conditions, and densification are imbedded in the model, utilizing the finite-element software COMSOL™, which possesses a distinguishing ability of coupling multiple physics. Thereby the implementation of a finite element method applicable to a broad range of SPS procedures is carried out, together with the more specific optimization of the SPS tooling design when dealing with excessive heating phenomena.

36 MATERIALS SCIENCE↗

Overview of KSTAR initial operation

Since the successful first plasma generation in the middle of 2008, three experimental campaigns were successfully made for the KSTAR device, accompanied with a necessary upgrade in the power supply, heating, wall-conditioning and diagnostic systems. KSTAR was operated with the toroidal magnetic field up to 3.6 T and the circular and shaped plasmas with current up to 700 kA and pulse length of 7 s, have been achieved with limited capacity of PF magnet power supplies. The mission of the KSTAR experimental program is to achieve steady-state operations with high performance plasmas relevant to ITER and future reactors. The first phase (2008-2012) of operation of KSTAR is dedicated to the development of operational capabilities for a super-conducting device with relatively short pulse. Development of start-up scenario for a super-conducting tokamak and the understanding of magnetic field errors on start-up are one of the important issues to be resolved. Some specific operation techniques for a super-conducting device are also developed and tested. The second harmonic pre-ionization with 84 and 110 GHz gyrotrons is an example. Various parameters have been scanned to optimize the pre-ionization. Another example is the ICRF wall conditioning (ICWC), which was routinely applied during the shot to shot interval. The plasma operation window has been extended in terms of plasma beta and stability boundary. The achievement of high confinement mode was made in the last campaign with the first neutral beam injector and good wall conditioning. Plasma control has been applied in shape and position control and now a preliminary kinetic control scheme is being applied including plasma current and density. Advanced control schemes will be developed and tested in future operations including active profiles, heating and current drives and control coil-driven magnetic perturbation.

Kwon, M↗

SU-F-T-347: An Absolute Dose-Volume Constraint Based Deterministic Optimization Framework for Multi-Co60 Source Focused Radiotherapy

Purpose: Treatment plan optimization in multi-Co60 source focused radiotherapy with multiple isocenters is challenging, because dose distribution is normalized to maximum dose during optimization and evaluation. The objective functions are traditionally defined based on relative dosimetric distribution. This study presents an alternative absolute dose-volume constraint (ADC) based deterministic optimization framework (ADC-DOF). Methods: The initial isocenters are placed on the eroded target surface. Collimator size is chosen based on the area of 2D contour on corresponding axial slice. The isocenter spacing is determined by adjacent collimator sizes. The weights are optimized by minimizing the deviation from ADCs using the steepest descent technique. An iterative procedure is developed to reduce the number of isocenters, where the isocenter with lowest weight is removed without affecting plan quality. The ADC-DOF is compared with the genetic algorithm (GA) using the same arbitrary shaped target (254cc), with a 15mm margin ring structure representing normal tissues. Results: For ADC-DOF, the ADCs imposed on target and ring are (D100>10Gy, D50,10, 0<12Gy, 15Gy and 20Gy) and (D40<10Gy). The resulting D100, 50, 10, 0 and D40 are (9.9Gy, 12.0Gy, 14.1Gy and 16.2Gy) and (10.2Gy). The objectives of GA are to maximize 50% isodose target coverage (TC) while minimize the dose delivered to the ring structure, which results in 97% TC and 47.2% average dose in ring structure. For ADC-DOF (GA) techniques, 20 out of 38 (10 out of 12) initial isocenters are used in the final plan, and the computation time is 8.7s (412.2s) on an i5 computer. Conclusion: We have developed a new optimization technique using ADC and deterministic optimization. Compared with GA, ADC-DOF uses more isocenters but is faster and more robust, and achieves a better conformity. For future work, we will focus on developing a more effective mechanism for initial isocenter determination.

60 APPLIED LIFE SCIENCES↗

SU-C-BRB-02: Symmetric and Asymmetric MLC Based Lung Shielding and Dose Optimization During Translating Bed TBI

Purpose: The primary aim was to introduce a dose optimization method for translating bed total body irradiation technique that ensures lung shielding dynamically. Symmetric and asymmetric dynamic MLC apertures were employed for this purpose. Methods: The MLC aperture sizes were defined based on the radiological depth values along the divergent ray lines passing through the individual CT slices. Based on these RD values, asymmetrically shaped MLC apertures were defined every 9 mm of the phantom in superior-inferior direction. Individual MLC files were created with MATLAB™ and were imported into Eclipse™ treatment planning system for dose calculations. Lungs can be shielded to an optimum level by reducing the MLC aperture width over the lungs. The process was repeated with symmetrically shaped apertures. Results: Dose-volume histogram (DVH) analysis shows that the asymmetric MLC based technique provides better dose coverage to the body and optimum shielding of the lungs compared to symmetrically shaped beam apertures. Midline dose homogeneity is within ±3% with asymmetric MLC apertures whereas it remains within ±4.5% with symmetric ones (except head region where it drops down to −7%). The substantial over and under dosage of ±5% at tissue interfaces has been reduced to ±2% with asymmetric MLC technique. Lungs dose can be reduced to any desired limit. In this experiment lungs dose was reduced to 80% of the prescribed dose, as was desired. Conclusion: The novel asymmetric MLC based technique assures optimum shielding of OARs (e.g. lungs) and better 3-D dose homogeneity and body-dose coverage in comparison with the symmetric MLC aperture optimization. The authors acknowledge the financial and infrastructural support provided by Pakistan Institute of Engineering & Applied Sciences (PIEAS), Islamabad and Aga Khan University Hospital (AKUH), Karachi during the course of this research project. Authors have no conflict of interest with any national / international body for the presented work.

60 APPLIED LIFE SCIENCES↗

Comparison of arc-modulated cone beam therapy and helical tomotherapy for three different types of cancer

Purpose: Arc-modulated cone beam therapy (AMCBT) is a fast treatment technique deliverable in a single rotation with a conventional C-arm shaped linac. In this planning study, the authors assess the dosimetric properties of single-arc therapy in comparison to helical tomotherapy for three different tumor types. Methods: Treatment plans for three patients with prostate carcinoma, three patients with anal cancer, and three patients with head and neck cancer were optimized for helical tomotherapy and AMCBT. The dosimetric comparison of the two techniques is based on physical quantities derived from dose-volume histograms. Results: For prostate cancer, the quality of dose distributions calculated for AMCBT was of equal quality as that generated for tomotherapy with the additional benefits of a faster delivery and a lower integral dose. For highly complex geometries, the plan quality achievable with helical tomotherapy could not be achieved with arc-modulated cone beam therapy. Conclusions: Rotation therapy with a conventional linac in a single arc is capable to deliver a high and homogeneous dose to the target and spare organs at risk. Advantages of this technique are a fast treatment time and a lower integral dose in comparison to helical tomotherapy. For highly complex cases, e.g., with several target regions, the dose shaping capabilities of AMCBT are inferior to those of tomotherapy. However, treatment plans for AMCBT were also clinically acceptable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electron choreography at the attosecond time scale

Abstract In this work, we report on coherent control of electron dynamics in atoms via attosecond pulse-shaping. We show that the photoelectron emission from argon gas produced by absorption of an attosecond pulse train (APT) made of odd and even harmonics can be manipulated along the direction of polarization of the light by tuning the spectral components (amplitude and phase) of the pulse. In addition, we show that APTs produced with a two-color (400- plus 800 nm) femtosecond driving field exhibit high temporal tunability, which is optimized for an intensity ratio between the two colors in the range of 0.1 to 5%.

74 ATOMIC AND MOLECULAR PHYSICS↗

Nuclear ground-state masses and deformations: FRDM(2012)

We tabulate the atomic mass excesses and binding energies, ground-state shell-plus-pairing corrections, ground-state microscopic corrections, and nuclear ground-state deformations of 9318 nuclei ranging from {sup 16}O to A=339. The calculations are based on the finite-range droplet macroscopic and the folded-Yukawa single-particle microscopic nuclear-structure models, which are completely specified. Relative to our FRDM(1992) mass table in Möller et al. (1995), the results are obtained in the same model, but with considerably improved treatment of deformation and fewer of the approximations that were necessary earlier, due to limitations in computer power. The more accurate execution of the model and the more extensive and more accurate experimental mass data base now available allow us to determine one additional macroscopic-model parameter, the density-symmetry coefficient L, which was not varied in the previous calculation, but set to zero. Because we now realize that the FRDM is inaccurate for some highly deformed shapes occurring in fission, because some effects are derived in terms of perturbations around a sphere, we only adjust its macroscopic parameters to ground-state masses. The values of ten constants are determined directly from an optimization to fit ground-state masses of 2149 nuclei ranging from {sup 16}O to {sub 106}{sup 265}Sg and {sub 108}{sup 264}Hs. The error of the mass model is 0.5595 MeV for the entire region of nuclei included in the adjustment, but is only 0.3549 MeV for the region N≥65. We also provide masses in the FRLDM, which in the more accurate treatments now has an error of 0.6618 MeV, with 0.5181 MeV for nuclei with N≥65, both somewhat larger than in the FRDM. But in contrast to the FRDM, it is suitable for studies of fission and has been extensively so applied elsewhere, with FRLDM(2002) constants. The FRLDM(2012) fits 31 fission-barrier heights from {sup 70}Se to {sup 252}Cf with a root-mean-square deviation of 1.052 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Using dorsal surface for individual identification of dairy calves through 3D deep learning algorithms

Advances in machine learning techniques have allowed the development of computer vision systems (CVS) that can accurately predict several phenotypes of interest for livestock operations. In this context, 3D images taken from a top-down view are particularly useful for estimating body condition score, growth development, and body biometrics in cattle. Frequently, such CVS rely on identification (ID) systems, such as electronic tags, as a way to match animal ID and the predicted phenotype. However, the same 3D images used to predict body weight and other animal biometrics could be adopted for animal recognition as well. Such alternative would optimize CVS to recognize animal ID and monitor growth development simultaneously while leveraging the same hardware infrastructure. Furthermore, this strategy could be used to recognize animals with similar color patterns. Nonetheless, growing animals are continuously changing body shape, which could limit its use as an invariant feature for pattern recognition. Thus, the objectives of this study were: (1) to compare algorithms for different 3D object representations to identify individual animals; and (2) to evaluate how short-term changes in body shape due to animal growth affect the predictive performance of these algorithms. For objective 1, the algorithms were trained (n = 4,558) and tested (n = 1,139) using images from 38 Holstein calves. For objective 2, we designed three different experiments using images (n = 2,347) from five Holstein calves taken over six weeks during their growing period, always training and testing on different weeks. Each experiment evaluated how changing a different parameter of the image capturing procedure affected the predictive ability of the trained algorithms. In the first experiment, we varied the total number of images per animal in the training set; in the second experiment, we varied the number of weeks while keeping a fixed number of images in the training set; and in the third experiment, we skipped weeks between images in the training and test sets. The F 1 score for objective (1) was up to 0.804 when testing with the last frames of each video, and up to 0.959 when using random frames for testing. For objective (2), the F 1 score was up to 0.947 for the first experiment when using 130 images per animal; up to 0.979 for the second experiment when using all five weeks; and up to 0.917 when not skipping weeks between training and testing. In conclusion, these results show that deep learning algorithms can be used to identify individual animals through their dorsal area 3D surfaces, and, from our experiments using calves in their growing period, that they are robust enough to account for changes in body shape and size, making them a promising tool for animal recognition during growth.

3D neural networks↗

Columnar to equiaxed transition and grain refinement of cast CrCoNi medium-entropy alloy by microalloying with titanium and carbon

Thermomechanical processing has been used to control the grain size/shape of the equiatomic CrCoNi medium-entropy alloy (MEA) and obtain excellent strength and ductility. However, in the cast state, the alloy has coarse columnar grains with average widths and lengths of approximately 120 and 1000 μm, respectively, resulting in inferior mechanical properties. To overcome this deficiency, we microalloyed with Ti and C and successfully changed the grain shape (from columnar to equiaxed) and refined the grain size. The degree to which the microstructure changes depends on the amount of Ti and C added, with the best results obtained at 0.4 at.% each. In the optimal alloy [(CrCoNi) 99.2 Ti 0.4 C 0.4 ], the as-cast grains were nearly equiaxed with a uniform size of ~75 μm. Associated with this change in grain shape/size was a significant improvement of yield strength, ultimate tensile strength and elongation to fracture at both 293 and 77 K. Finally, the columnar to equiaxed transition is attributed to the strong mutual affinity of C and Ti, which leads to their build-up ahead of the solid-liquid interface and, in turn, to enhanced constitutional undercooling.

36 MATERIALS SCIENCE↗

Joining Light Metals with Polymer Composites Through Metal Overcasting

This work investigates a unique technique to join aluminum (Al) and magnesium (Mg) alloys to carbon fiber reinforced polymer (CFRP) composites without the use of adhesives or mechanical fasteners. The joints were made using an overcasting technique where the molten alloys were cast around the polymer composites using high pressure die casting method. Rapid cooling during casting allowed the composite to be embedded inside the cast metal without causing any gross damage to the former even though the molten metal temperature exceeded the melting point of the composite matrix by several 100’s of deg. C. The metal/composite interface was examined using optical microscopy and x-ray imaging and the joint strength was examined through tensile testing. Although evidence of polymer melting was evident in the x-ray images, the embedded section of the composite coupons retained their overall shape and integrity. Preliminary tension tests on Al/CFRP composites showed strength degradation of the CFRP and it failed near the metal/CFRP interface (outside the joint). Strength degradation in the CFRP suggests that the overcasting process needs further optimization to minimize thermal excursion in the CFRP. Nevertheless, the overcasting process shows great promise as a unique joining technique with application in fabricating light-weight structures for automotive and transportation industries.

overcasting, Casting, Mg Castings, Al Casting, Joi↗