Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor selection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Application and Certification of Comparative Vacuum Monitoring Sensors for Structural Health Monitoring of 737 Wing Box Fittings

Multi-site fatigue damage, hidden cracks in hard-to-reach locations, disbonded joints, erosion, impact, and corrosion are among the major flaws encountered in today's extensive fleet of aging aircraft and space vehicles. The use of in-situ sensors for real-time health monitoring of aircraft structures are a viable option to overcome inspection impediments stemming from accessibility limitations, complex geometries, and the location and depth of hidden damage. Reliable, structural health monitoring systems can automatically process data, assess structural condition, and signal the need for human intervention. Prevention of unexpected flaw growth and structural failure can be improved if on-board health monitoring systems are used to continuously assess structural integrity. Such systems are able to detect incipient damage before catastrophic failures occurs. Condition-based maintenance practices could be substituted for the current time-based maintenance approach. Other advantages of on-board distributed sensor systems are that they can eliminate costly, and potentially damaging, disassembly, improve sensitivity by producing optimum placement of sensors and decrease maintenance costs by eliminating more time- consuming manual inspections. This report presents a Sandia Labs-aviation industry effort to move SHM into routine use for aircraft maintenance. This program addressed formal SHM technology validation and certification issues so that the full spectrum of concerns, including design, deployment, performance and certification were appropriately considered. The Airworthiness Assurance NDI Validation Center (AANC) at Sandia Labs, in conjunction with Boeing, Delta Air Lines, Structural Monitoring Systems Ltd., Anodyne Electronics Manufacturing Corp. and the Federal Aviation Administration (FAA) carried out a certification program to formally introduce Comparative Vacuum Monitoring (CVM) as a structural health monitoring solution to a specific aircraft wing box application. Validation tasks were designed to address the SHM equipment, the health monitoring task, the resolution required, the sensor interrogation procedures, the conditions under which the monitoring will occur, the potential inspector population, adoption of CVM into an airline maintenance program and the document revisions necessary to allow for routine use of CVM as an alternate means of performing periodic structural inspects. To carry out the validation process, knowledge of aircraft maintenance practices was coupled with an unbiased, independent evaluation. Sandia Labs designed, implemented, and analyzed the results from a focused and statistically-relevant experimental effort to quantify the reliability of the CVM system applied to the Boeing 737 Wing Box fitting application. All factors that affect SHM sensitivity were included in this program: flaw size, shape, orientation and location relative to the sensors, as well as operational and environmental variables. Statistical methods were applied to performance data to derive Probability of Detection (POD) values for CVM sensors in a manner that agrees with current nondestructive inspection (NDI) validation requirements and also is acceptable to both the aviation industry and regulatory bodies. This report presents the use of several different statistical methods, some of them adapted from NDI performance assessments and some proposed to address the unique nature of damage detection via SHM systems, and discusses how they can converge to produce a confident quantification of SHM performance An important element in developing SHM validation processes is a clear understanding of the regulatory measures needed to adopt SHM solutions along with the knowledge of the structural and maintenance characteristics that may impact the operational performance of an SHM system. This report describes the major elements of an SHM validation approach and differentiates the SHM elements from those found in NDI validation. The activities conducted in this program demonstrated the feasibility of routine SHM usage in general and CVM in particular for the application selected. They also helped establish an optimum OEM-airline-regulator process and determined how to safely adopt SHM solutions. This formal SHM validation will allow aircraft manufacturers and airlines to confidently make informed decisions about the proper utilization of CVM technology. It will also streamline the regulatory actions and formal certification measures needed to assure the safe application of SHM solutions.

42 ENGINEERING↗

The Structure and Transport of Water and Hydrated Ions Within Hydrophobic, Nanoscale Channels

The purpose of this project includes an experimental and modeling investigation into water and hydrated ion structure and transport at nanomaterials interfaces. This is a topic relevant to understanding the function of many biological systems such as aquaporins that efficiently shuttle water and ion channels that permit selective transport of specific ions across cell membranes. Carbon nanotubes (CNT) are model nanoscale, hydrophobic channels that can be functionalized, making them artificial analogs for these biological channels. This project investigates the microscopic properties of water such as water density distributions and dynamics within CNTs using Nuclear Magnetic Resonance (NMR) and the structure of hydrated ions at CNT interfaces via X-ray Absorption Spectroscopy (XAS). Another component of this work is molecular simulation, which can predict experimental measurables such as the proton relaxation times, chemical shifts, and can compute the electronic structure of CNTs. Some of the fundamental questions this work is addressing are: (1) what is the length scale below which nanoscale effects such as molecular ordering become important, (2) is there a relationship between molecular ordering and transport?, and (3) how do ions interact with CNT interfaces? These are questions of interest to the scientific community, but they also impact the future generation of sensors, filters, and other devices that operate on the nanometer length scale. To enable some of the proposed applications of CNTs as ion filtration media and electrolytic supercapacitors, a detailed knowledge of water and ion structure at CNT interfaces is critical.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Photon Detector For Inverse Photoemission Spectroscopy With Improved Energy Resolution

We present the results from newly designed and fabricated double window photon detector to improve the overall energy resolution for inverse photoemission spectroscopy (IPES). This simple design allows us to introduce an absorption gas (Krypton) to decrease the band-width of the energy selective photon detector and thus improve the resolution. Resonance absorption line of Kr of wavelength of 123.6 nm was used. By fitting the Fermi edge of the IPES spectrum of silver, we find an overall energy resolution improved by 73 meV. The design is modular and ensures ease and safety of handling.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A multi-cone x-ray imaging Bragg crystal spectrometer

This article describes a new x-ray imaging Bragg crystal spectrometer, which—in combination with a streak camera or a gated strip detector—can be used for time-resolved measurements of x-ray line spectra at the National Ignition Facility and other high power laser facilities. The main advantage of this instrument is that it produces perfect images of a point source for each wavelength in a selectable spectral range and that the detector plane can be perpendicular to the crystal surface or inclined by an arbitrary angle with respect to the crystal surface. Furthermore, these unique imaging properties are obtained by bending the x-ray diffracting crystal into a certain shape, which is generated by arranging multiple cones with different aperture angles on a common nodal line.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal Hydraulic Experimental Test Article (FY2020 Status Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA will be installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2. The design work for the facility has been completed. Since the FY19 THETA status report, the THETA primary system components have been assembled and tested using de-ionized water. Some results of this testing at select Richardson and Reynolds numbers are included herein. The custom THETA sodium flowmeter (permanent magnet submersible sodium flowmeter) has been built and calibrated using sodium in an auxiliary facility against a NIST traceable vortex shedder type flowmeter. The permanent magnet flowmeter showed excellent performance, following the theoretical equation for measured voltage quite well, with an error < 3.5% at flow rates ranging from 3-24 GPM at temperatures up to 400 °C. The secondary sodium system for heat rejection from intermediate heat exchanger has been analyzed according to ASME code. All secondary side piping, fittings and a U-stamped air-to-sodium heat exchanger have been procured.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Highly Integrated Wide Bandgap Power Module for Next Generation Plug-In Vehicles (Final Report)

Wide bandgap devices are key enablers for high power density traction inverters. A highly integrated wide bandgap (WBG) power module enables higher temperature operation, higher inverter efficiency and overall smaller die area with the same power delivery. However, it requires careful design of the power module to take advantage of all the superior material properties that silicon carbide (SiC) provides over conventional silicon (Si) Insulated Gate Bipolar Transistor (IGBT) based design. This project developed an efficient and densely packed SiC power module for an automotive traction inverter application. Extensive study was performed to select the best performing SiC die considering a wide range of temperature variation, suitability to integrate into target packaging, robust body diode performance and overall high electrical efficiency. Multiple design ideas were explored to achieve lower stray inductance for both power loop and signal loop, uniform current distribution, compact form factor, and very high thermal performance. The final power module package includes all six inverter switches in the same module (six-pack) with die sintered at both bottom and top surfaces utilizing high performance substrate to achieve high electrical and thermal performance. Two power module variants were developed using 900 V and 1200 V devices for operating at two different high voltage levels (> 600 V HV battery). Both power modules were comprehensively characterized, and high efficiency operation of the inverter was confirmed through analysis. Finally, a complete functional inverter was built with the 1200V power modules using other essential components (HV capacitors, gate driver board, controller board, current sensor, connectors etc.) and tested using GM’s standard test procedure. There are several challenges associated with adopting WBG devices for high voltage operation. In order to assess and mitigate those challenges, GM and subrecipients of this project have conducted multiple detailed studies. This includes phase current reconstruction using integrated Rogowski coil, device junction temperature estimation using on-state gate resistance, modeling and testing the effect of high voltage and fast switching on motor insulation and bearings, partial discharge inception voltage measurement under different environmental conditions. Findings of all these studies are summarized in this report.

33 ADVANCED PROPULSION SYSTEMS↗

Aromatic 3,5-Di(2′,4′-dicarboxylphenyl)benozoic acid based coordination polymers as luminescent sensor for the sensitive detection of chromate anions in aqueous solution

Highlights: • The novel pentacarboxylate of 3,5-di(2′,4′-dicarboxylphenyl)benozoic acid were firstly introduced here. • Topology analyses reveal that complex 1 is a 2D {6"3}{sub 2}{6"4.8.10}{6"4.8"2}{sub 2} trilayer structure, and complex 2 is a 3D {6.8"2}{sub 2}{6"4.8"2}{sub 2}{8.10"4.12} network. • Two coordination polymers both show highly sensitive sensing of Cr(VI) anions in aqueous solution. - Abstract: Based on the mixed ligands of aromatic pentacarboxylate of 3,5-di(2′,4′-dicarboxylphenyl)benozoic acid (H{sub 5}L) and 1,4-bis(imidazol-1-yl) benzene (bib), two novel coordination polymers, namely, [Ni{sub 1.5}(H{sub 2}L)(bib){sub 1.5}(H{sub 2}O){sub 2}]{sub n} (1), and {[Pb_2(HL)(bib)_1_._5(H_2O)]·H_2O}{sub n} (2) have been synthesized and characterized by EA, IR, TG, PXRD. Structure analyses reveal that complexes 1 and 2 are both (3,4,4)-connected structures with the same stoichiometry of (3-c){sub 2}(4-c){sub 2}(4-c), the 2D {6"3}{sub 2}{6"4.8.10}{6"4.8"2}{sub 2} trilayer for 1, and 3D {6.8"2}{sub 2}{6"4.8"2}{sub 2}{8.10"4.12} network for 2. Complexes 1 and 2 exhibit excellent recyclable, selective, and sensitive detection of Cr(VI) anions in aqueous solution. The possible mechanism for selective luminescence quenching responses toward Cr(VI) anions is also discussed in detail.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Molecular Dynamics Investigation of the ω-Current in the Kv1.2 Voltage Sensor Domains

Voltage sensor domains (VSD) are transmembrane proteins that respond to changes in membrane voltage and modulate the activity of ion channels, enzymes, or in the case of proton channels allow permeation of protons across the cell membrane. VSDs consist of four transmembrane segments, S1–S4, forming an antiparallel helical bundle. The S4 segment contains several positively charged residues, mainly arginines, located at every third position along the helix. In the voltage-gated Shaker K + channel, the mutation of the first arginine of S4 to a smaller uncharged amino acid allows permeation of cations through the VSD. These currents, known as ω-currents, pass through the VSD and are distinct from K + currents passing through the main ion conduction pore. Here we report molecular dynamics simulations of the ω-current in the resting-state conformation for Kv1.2 and for four of its mutants. The four tested mutants exhibit various degrees of conductivity for K + and Cl - ions, with a slight selectivity for K + over Cl - . Analysis of the ion permeation pathway, in the case of a highly conductive mutant, reveals a negatively charged constriction region near the center of the membrane that might act as a selectivity filter to prevent permeation of anions through the pore. The residues R1 in S4 and E1 in S2 are located at the narrowest region of the ω-pore for the resting state conformation of the VSD, in agreement with experiments showing that the largest increase in current is produced by the double mutation E1D and R1S.

Biophysics↗

Readout IC requirement trends based on a simplified parametric seeker model.

Modern space based optical sensors place substantial demands on the focal plane array readout integrated circuit. Active pixel readout designs offer direct access to individual pixel data but require analog to digital conversion at or near each pixel. Thus, circuit designers must create precise, fundamentally analog circuitry within tightly constrained areas on the integrated circuit. Rapidly changing phenomena necessitate tradeoffs between sampling and conversion speed, data precision, and heat generation adjacent the detector array, especially of concern for thermally sensitive space grade infrared detectors. A simplified parametric model is presented that illustrates seeker system performance and analog to digital conversion requirements trends in the visible through mid-wave infrared, for varying sample rate. Notional limiting-case Earth optical backgrounds were generated using MODTRAN4 with a range of cloud extremes and approximate practical albedo limits for typical surface features from a composite of the Mosart and Aster spectral albedo databases. The dynamic range requirements imposed by these background spectra are discussed in the context of optical band selection and readout design impacts.

47 OTHER INSTRUMENTATION↗

Enhanced biochemical sensing with high- Q transmission resonances in free-standing membrane metasurfaces

Optical metasurfaces provide solutions to label-free biochemical sensing by localizing light resonantly beyond the diffraction limit, thereby selectively enhancing light–matter interactions for improved analytical performance. However, high-Q resonances in metasurfaces are usually achieved in the reflection mode, which impedes metasurface integration into compact imaging systems. Here, we demonstrate a metasurface platform for advanced biochemical sensing based on the physics of the bound states in the continuum (BIC) and electromagnetically induced transparency (EIT) modes, which arise when two interfering resonances from a periodic pattern of tilted elliptic holes overlap both spectrally and spatially, creating a narrow transparency window in the mid-infrared spectrum. We experimentally measure these resonant peaks observed in transmission mode (Q ~ 734 at λ ~ 8.8 µm) in free-standing silicon membranes and confirm their tunability through geometric scaling. We also demonstrate the strong coupling of the BIC-EIT modes with a thinly coated PMMA film on the metasurface, characterized by a large Rabi splitting (32 cm -1 ) and biosensing of protein monolayers in transmission mode. Our new photonic platform can facilitate the integration of metasurface biochemical sensors into compact and monolithic optical systems while being compatible with scalable manufacturing, thereby clearing the way for on-site biochemical sensing in everyday applications.

Rosas, Samir [Univ. of Wisconsin, Madison, WI (Uni↗

Development of High-Temperature Bonding Techniques to Enable High-Temperature Static or Dynamic Strain Measurements

Current light-water nuclear reactors rely on a variety of different sensors and sensor applications to meet their structural health monitoring needs throughout the entirety of the reactor primary, secondary, and containment systems. Optical fiber–based sensor technologies could provide solutions to reduce the sensor system footprint while enhancing the measurement fidelity and spatial resolution by leveraging distributed monitoring techniques. Moreover, advanced reactors may require optical fiber–based sensors for structural health monitoring because their operating temperatures will exceed the limits of conventional transducers used to acquire dynamic strain or acoustic data in nuclear power plants. Therefore, this report describes experiments targeting the development of high-temperature bonding techniques that would allow for potentially long lengths of fibers to be bonded to metallic reactor components in advanced reactor systems. The high temperatures experienced within target application, next-generation nuclear reactors, necessitate a high-temperature resistant bond to limit the amount of tension on the fiber at the target application temperature. The primary bonding method investigated in this work is brazing; hot-rolling has also been investigated to a lesser extent. Both techniques are well-suited to bonding optical fibers to large reactor components such as primary coolant piping, pressure vessels, or heat exchangers. Optical frequency domain reflectometry was used to monitor the strain in metal-coated optical fibers before, during, and after the high-temperature bonding process. On select optical fibers that were successfully bonded, additional thermal cycling was performed to assess the extent to which the fiber remained bonded based on the expected thermal expansion of the test specimen material. The results of the various experiments yielded the following general conclusions: (1) brazing is a viable technique for bonding and allows significant compressive strain to be applied to the fiber at room temperature; (2) hot-rolling is a viable technique as well, which has been more optimized than the brazing technique for bonding, but less residual compressive strain has been observed with this technique; and (3) both techniques will need further development and optimization to demonstrate bonding of a long length of fiber that can provably operate at relevant temperatures for an advanced nuclear reactor application.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Puromycin-resistant lentiviral control shRNA vector, pLKO.1 induces unexpected cellular differentiation of P19 embryonic stem cells

RNA silencing is used as a common method for investigating loss-of-function effects of genes of interest. In mammalian cells, RNA interference (RNAi) or RNA silencing can be achieved by transient siRNA (small or short interfering RNA) transfection or by stable shRNA (short hairpin RNA) systems. Various vectors are used for efficient delivery of shRNA. Lentiviral vectors offer an efficient delivery system for stable and long-term expression of the shRNA in mammalian cells. The widely used lentiviral pLKO.1 plasmid vector is very popular in RNAi studies. A large RNAi database, a TRC (the RNAi Consortium) library, was established based on the pLKO.1-TRC plasmid vector. This plasmid (also called pLKO.1-puro) has a puromycin-resistant gene for selection in mammalian cells along with designs for generating lentiviral particles as well for RNA silencing. While using the pLKO.1-puro TRC control shRNA plasmid for transfection in murine P19 embryonic stem (ES) cells, it was unexpectedly discovered that this plasmid vector induced robust endodermal differentiation. Since P19 ES cells are pluripotent and respond to external stimuli that have the potential to alter the phenotype and thus its stemness, other cell types used in RNA silencing studies do not display the obvious effect and therefore, may affect experiments in subtle ways that would go undetected. This study for the first time provides evidence that raises concern and warrants extreme caution while using the pLKO.1-puro control shRNA vector because of its unexpected non-specific effects on cellular integrity. - Highlights: • In P19 ES cells the pLKO.1-puro lentiviral control shRNA vector induced endodermal differentiation. • P19 ES cells harboring the pCDNA3 plasmid vector retained their stem-ness as opposed to those harboring the pLKO.1-puro vector. • P19 ES cells can serve as a sensor to determine vector safety. • Extreme caution is warranted while using the widely used pLKO.1-puro lentiviral vector for experimental and therapeutic designs.

60 APPLIED LIFE SCIENCES↗

Test beam demonstration of silicon microstrip modules with transverse momentum discrimination for the future CMS tracking detector

A new CMS Tracker is under development for operation at the High Luminosity LHC from 2026 onwards. It includes an outer tracker based on dedicated modules that will reconstruct short track segments, called stubs, using spatially coincident clusters in two closely spaced silicon sensor layers. These modules allow the rejection of low transverse momentum track hits and reduce the data volume before transmission to the first level trigger. The inclusion of tracking information in the trigger decision is essential to limit the first level trigger accept rate. A customized front-end readout chip, the CMS Binary Chip (CBC), containing stub finding logic has been designed for this purpose. A prototype module, equipped with the CBC chip, has been constructed and operated for the first time in a 4 GeemVem/emc positron beam at DESY. The behaviour of the stub finding was studied for different angles of beam incidence on a module, which allows an estimate of the sensitivity to transverse momentum within the future CMS detector. A sharp transverse momentum threshold around 2 emVem/emc was demonstrated, which meets the requirement to reject a large fraction of low momentum tracks present in the LHC environment on-detector. This is the first realistic demonstration of a silicon tracking module that is able to select data, based on the particle's transverse momentum, for use in a first level trigger at the LHC . The results from this test are described here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-Time Monitoring of Selenium Species in Power Plant Wastewaters via Optical Spectroscopy

Energy Research Company (ERCo) and Lehigh University are developing a new rapid sensor for measuring trace amounts of selenium in coal-fired power plant wastewater streams down to the single parts-per-billion (ppb) level. With EPA regulations pending on releases of selenium in wastewaters from power plants, plant operators are finding that commercially available technology is not suitable for ensuring compliance with the new regulations. These regulations require monitoring selenium at the single ppb level. There are several important advantages of our instrument as compared to other potential methods such as ICP-MS or ICP-OES. First, the method is rapid, allowing for analyses within minutes. Second, the method is amenable to automation, so dedicated lab personnel are not required. Third, the apparatus is compact and comprised of off-the-shelf components that are inexpensive compared to other laboratory instruments. Fourth, our instrument is designed to be used in the field and will collect data from any water source in near real time. Fifth, maintenance is minimal and finally, the cost is quite low. Furthermore, selective concentration of different ionization states of selenium was also demonstrated. Selenium is present in wastewaters in two main ionization states, +4 and +6. The fraction of each ionization state is important to know because it affects selenium treatment technologies. We were able to measure each one with a single instrument. The Phase II work plan will automate our instrument and expand the measurements to other heavy metals such as mercury and arsenic, the two other heavy metals covered in the new EPA regulations. We will also field test the instrument at an operating coal fired power plant.

20 FOSSIL-FUELED POWER PLANTS↗

Integrated Approach to Fluoride High Temperature Reactor Technology and Licensing Challenges (FHR-IRP)

This document constitutes progress made on this project by the Georgia Tech led Integrated Approach to Fluoride High Temperature Reactor Technology and Licensing Challenges (FHR-IRP). This is the first draft of the project final report. Chapter 3 is focused on Tritium management. Tritium management in Fluoride-salt High-temperature Reactors (FHRs) presents a major operational concern and a significant challenge. Tritium is generated via multiple pathways including various interactions in fuel and structural materials, as well as coolant (primarily interaction with lithium and beryllium), leading to a complex evolution and spatial distribution of tritium generation rate. FHR generates orders of magnitude more tritium than in LWRs, and has potential for a significant release, via permeation through structural materials (due to high temperature), and through heat exchanger(s). Therefore, accurate estimate is necessary. For that purpose relevant tritium production pathways were identified. A methodology to obtain space-time dependent tritium generation rate was developed and implemented, employing SCALE and MCNP codes. Detailed models of the reference Advanced High Temperature Reactor (AHTR) design were developed. A multi-parametric metrics was introduced to capture relevant tritium production indicators, including the instantaneous tritium production rate, total tritium production (neglecting subsequent decay), and accumulated tritium production (accounting for the decay). The obtained results will inform tritium management, including the sizing of the components, and to gain insight on the impact of the core design parameters on tritium generation rates. Research effort on Liquid Salt Impurity Removal, Redox and Corrosion Control is discussed in Chapter 4. Section 4.1 is an introduction chapter. Based on the current available knowledge and operation experience on previous MSRs and other types of nuclear reactors, the report identifies the major impurities that are related to either material compatibility, salt properties or radioactive source terms, and the potential contamination sources of these impurities, their transport in the primary coolant loop and available cleanup methodologies for a particular group of impurity. In section 4.2, the available purification methods were discussed, including the liquid/liquid extraction using liquid Bi-Li which has been applied in MSBR and electrochemical purification which is developed based on Pyroprocessing. In this section, the new multi-stage and multi-salt-component was developed and discussed. Section 4.3 discussed the redox potential control for salt chemistry and corrosion mitigation, including the control theory and the soluble/soluble buffer control method. The section also developed method on how to analyze soluble/soluble redox reaction in a molten salt system and designed an electrochemical sensor for redox potential control. Corrosion models were also reported in this section. Section 4.4 focused on how to measure the fundamental properties in a molten salt. As an example, the section focused on La fluoride in the molten salt. The section developed methods on how analyze electrochemical measurement data to obtain the fundamental properties including the redox potential, diffusion coefficient and exchange current density. All these fundamental information is important for salt purification system development. Section 4.5 focused on measurements of corrosion products in the salts. Because of the different behaviors between Cr and La in the salt, new analysis method for Cr fluorides in the salt was developed. Some results for Fe fluoride in the salt and corrosion measurements were also reported. Section 4.6 demonstrated the separation of oxide from the salt. This section also measured the solubility of La 2 O 3 in the salt as function of temperature. Section 4.7 focused on the separation of La and Ce from the molten salt. These two elements were selected because La was found to be separated by using inert electrode, while for separation of Ce, reactive electrode must be selected. Section 4.8 demonstrated the separation iodine ions from the molten salt. Two kinds of working electrode materials (metal W and graphite) were investigated. Section 4.9 focused on the fundamental data of fission products and actinides in liquid Bi. The chapter reviewed the available data, then based a CALPHAD model, the available data were broadened to the concentration-dependent cases.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Selective Thermal Reduction of Single-layer MoO3 nanostructures on Au(111)

MoO{sub 3} is an interesting oxide prototype because its catalytic activity is sensitive to the presence and nature of defects. In this work, we demonstrate that we can control the number of defects in single-layer MoO{sub 3} nanostructures grown on Au(111) by a simple thermal reduction treatment. X-ray photoelectron spectroscopy demonstrates the formation of Mo{sup 5+} species and oxygen vacancies during annealing at 650 K. The percentage of Mo{sup 5+} increases with the duration of annealing, until a stable composition containing 50% Mo{sup 6+} and 50% Mo{sup 5+} is obtained. Surprisingly, the formation of lower oxidation states such as Mo{sup 4+} was not observed. The reduced MoO{sub x} islands remain one layer high, based on scanning tunneling microscope (STM) images. The two-dimensional nature of the reduced oxide nanocrystals may be due to a large barrier for structural reorganization and, thus, may account for the absence of Mo oxidation states lower than +5. Based on scanning tunneling microscopy images and density functional calculations, we propose that the formation of Mo{sup 5+} ions during annealing is not associated with formation of oxygen point defects, but can be attributed to the formation of extended one-dimensional shear defects. These reduced structures are useful for studying the dependence of reactivity on defect type, and present exciting possibilities for chemical sensors and other applications.

36 MATERIALS SCIENCE↗

Colors of entangled two-photon absorption

Multiphoton absorption of entangled photons offers ways for obtaining unique information about chemical and biological processes. Measurements with entangled photons may enable sensing biological signatures with high selectivity and at very low light levels to protect against photodamage. In this paper, we present a theoretical and experimental study of the excitation wavelength dependence of the entangled two-photon absorption (ETPA) process in a molecular system, which provides insights into how entanglement affects molecular spectra. We demonstrate that the ETPA excitation spectrum can be different from that of classical TPA as well as that for one-photon resonant absorption (OPA) with photons of doubled frequency. These results are modeled by assuming the ETPA cross-section is governed by a two-photon excited state radiative linewidth rather than by electron-phonon interactions, and this leads to excitation spectra that match the observed results. Further, we find that the two-photon-allowed states with highest TPA and ETPA intensities have high electronic entanglements, with ETPA especially favoring states with the longest radiative lifetimes. These results provide concepts for the development of quantum light–based spectroscopy and microscopy that will lead to much higher efficiency of ETPA sensors and low-intensity detection schemes.

Science & Technology - Other Topics↗

Nanomaterial-Treated Filters for the Uptake of Heavy Metals from Water Sources

We describe the synthesis and properties of ligand-modified gold nanoparticles (AuNPs) grown on stainless steel wool filters. Their selectivity and efficiency with regards to heavy metal uptake from groundwater and other sources of drinking water found at or near DOE facilities were also investigated. The nanomaterial-treated filters are advantageous because they serve as inactive supports that allow for efficient flow of the contaminated water, and can be easily replaced after heavy metal uptake. They are also comparable to nanomaterials free in solution with regards to the effectiveness of remediation of drinking water. Environmental stewardship is at the forefront of core competencies at SRNS. This includes treatment and remediation of contaminated groundwater. Among contaminants present in water resources, hazardous heavy metals and radioactive contaminants are the main concerns in the DOE complex. With the advent of nanotechnology, new remediation technologies have emerged. AuNPs have unique optical properties and enormous surface areas, making them good candidates for water remediation. They can be functionalized with ligands, e.g. citrate and L-cysteine, allowing them to serve as an excellent platform for environmental stewardship applications. Objectives: 1. Nanomaterial development and characterization Ligand-modified AuNPs: (a) in solution and (b) on stainless steel wool filters 2. Nanomaterial evaluation for efficiency and selectivity of heavy metal uptake, including Cu{sup 2+} and Zn{sup 2+}. Materials and Methods: Chloroauric acid (HAuCl{sub 4}), sodium citrate (reducing and capping agent); Stainless steel wool (SSW) was used as a support and filter; L-cysteine- ligand for surface functionalization; Zinc acetate and copper nitrate: heavy metal ions contaminants. Au NPs were prepared by wet chemistry methods. They were characterized by UV-Vis, Zeta sizer and potential, SEM, EDS and EDS mapping to understand their physico-chemical properties. Results and Discussions: Surface modification of AuNPs with surfactants changes their optical properties. Citrate capped AuNPs demonstrate high loading capacity for both heavy metals. L-cysteine capped AuNPs demonstrate high loading capacity for Zn{sup 2+}. Citrate capped AuNPs have excellent sensitivity towards heavy metal ions (0.05 mM can be detected). L-cysteine capped AuNPs can detect heavy metal ions at low concentrations, making them useful for sensing. Conclusions: AuNPs in solution and on SSW were successfully synthesized and characterized. Two functional sensing and remediation technologies - colorimetric sensor and AuNP-treated filters - were developed through wet chemistry methods. AuNP SSW filters exhibit different characteristics (size, shape, etc.) than AuNPs in solution and are efficient at the uptake of heavy metal ions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗