At least 1,279 records · Page 71

Optimal scheduling for profit maximization of energy storage merchants considering market impact based on dynamic programming

This paper analyzes how electricity merchants' market impact affects merchants' profit. Energy storage has long been studied for its role in maximizing profit, and merchant decisions are assumed to have no impact on market prices. However, the trading decisions of large-scale energy storage merchants (e.g., pumped storage hydro) will affect the market prices. This paper employs dynamic programming theory to investigate merchants' optimal economic dispatch considering the market impact and physical characteristics of storage systems. Our findings show that the State-of-Charge (SOC) based analytical solution significantly facilitates energy storage merchants' decision-making. The SOC range is segmented into three regions by two optimal SOC reference points, which depend on the available energy in storage, given prices, and market impact. By comparing the current storage SOC with the reference points, the merchant can get the corresponding optimal actions. We analytically show that if the merchant neglects the market impact on the power market, she will exaggerate her expected profit when the price-taker and price-maker merchants have the same generating and pumping upper limits offered to Independent System Operators (ISOs). Furthermore, the profit-maximizing merchant must, therefore, assay to balance the trade-off correctly between the intensity of market impact and the dispatched power. Our findings are verified by numerical simulation, and results demonstrate the ramifications for electricity merchants in energy arbitrage decisions.

25 ENERGY STORAGE↗

A bilevel multistage stochastic self-scheduling model with indivisibilities for trading in the continuous intraday electricity market

In this paper, we study the profit maximization problem of a virtual power plant trading in the continuous intraday electricity market. Our virtual power plant model is compatible with renewable, and thermal assets, covering a range of virtual power plants currently participating in energy markets. We model the trading problem as a bilevel multistage stochastic program. The upper level of the problem accounts for the profit maximization of the virtual power plant with explicit modeling of the technical constraints of the operational status of the thermal power plant including minimum start-up and shut-down times, ramp-up and ramp-down rates, and minimum generation level. The upper level also decides which continuous and indivisible (fill-or-kill) orders are submitted to the market. The lower-level problem accounts for the clearing of the continuous intraday market, i.e., matching of buy and sell orders. Because of the presence of fill-or-kill orders, the lower-level problem is mixed-integer, which prevents its direct conversion to a single-level problem using duality. In order to solve this challenging problem, we develop a convex-hull extended formulation for the lower-level problem, apply duality theory to obtain a single-level stochastic equivalent formulation, and employ McCormick envelopes to turn the problem into a multistage stochastic mixed-integer linear problem, which we solve using the stochastic dual dynamic integer programming algorithm. We conduct numerical experiments and analyze the optimal trading behavior of a virtual power plant trading in an ideal continuous market without arbitrage.

Bilevel multistage stochastic programming problem↗

Co-optimization of nuclear reactor flexible power operation and maintenance scheduling

As flexible power operation of nuclear power plants becomes more attractive due to the reduction in fossil-fueled dispatchable generation on energy grids, finding optimal power production strategies that balance revenue generation with operational concerns becomes more complex. This article presents a general framework to aid operators in designing economically optimal long term dispatch strategies for nuclear power plants. The principal novelty is the linking of estimated system remaining useable life (RUL) to strategic operational decisions. It is shown that, depending on the relationship between the fixed costs from maintenance and the associated lost revenue from an outage, it can be economically optimal in the long term to delay a maintenance outage and not perform this alongside refueling. For a given relationship between power ramping and degradation, optimal strategies were found that discouraged load following in some situations while minimizing unnecessary maintenance. It is shown that heavy load following can cause maintenance and refueling outages to diverge due to their inverse relationships with respect to load following, potentially leading to a significant loss in capacity factor. As a result, this general framework can be applied to specific reactor dispatch allowing operators to adapt operational strategies as future grid conditions change.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Post-extreme-event restoration using linear topological constraints and DER scheduling to enhance distribution system resilience

In this paper, a post-extreme-event restoration (PEER) algorithm is proposed to improve distribution system resilience. Linear topological constraints are proposed to ensure radial topology after N-k contingencies, possibly in multiple islands. The approach is made comprehensive by considering dispatchable distributed energy resources (DERs), non-dispatchable DERs, and demand responses, as well as on-load tap changers (OLTCs) and shunt capacitors. The goal is to minimize the accumulative expense caused by load reduction payment or penalty, as well as DER operation cost. As a result, the overall system will survive longer with higher resilience during an extreme event. To verify the effectiveness of the PEER algorithm, we proposed a resilience evaluation algorithm using Monte Carlo simulation (MCS) with reduced scenarios. This is based on a probabilistic model for generating random scenarios which consider the uncertainty of line faults and solar irradiance. Combined with the proposed PEER algorithm, this reduced-scenario MCS can evaluate the expected energy not served (EENS) which is an essential index for distribution system resilience. Case studies of the IEEE 33-bus and 123-bus test systems validate the proposed algorithm in reducing EENS.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Tri-level hybrid interval-stochastic optimal scheduling for flexible residential loads under GAN-assisted multiple uncertainties

Various building loads, such as heating, ventilation, and air conditioners (HVACs), electric water heaters (EWHs), and electric vehicles (EVs), can introduce opportunities for improving the flexibility of electricity consumption while satisfying the needs of building owners as well as benefiting the resilience of distribution system. To utilize such flexibility, a tri-level distribution market framework is established, including residential consumers, load aggregators (LAs), and the distribution system operator (DSO). In this work, the uncertainties from all three levels are considered. The random consumption behavior at the consumer level is modeled as a Gaussian noise that is also aggregated and transmitted to the LA level. The weather temperature in the LA level is forecasted as an interval, and the photovoltaic (PV) power in the market-clearing level is modeled by a set of power scenarios generated by Generative Adversarial Networks (GANs). Then, a hybrid interval-stochastic programming is proposed to transform the uncertain problems in the first two levels into deterministic ones. For real-time implementations, a rolling horizon optimization (RHO) scheme is employed to continuously optimize the power consumption based on the latest operating information. Finally, case studies on a modified IEEE 69-bus system validate the effectiveness of the proposed uncertainty modeling strategies and the RHO scheme.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Late Effects After Radiotherapy for Locally Advanced Cervical Cancer: Comparison of Two Brachytherapy Schedules and Effect of Dose Delivered Weekly

Purpose: To compare the severe late effects (Grade 3 or greater) for two groups of cervical cancer patients treated with the same external beam radiotherapy and two high-dose-rate intracavitary brachytherapy regimens and to investigate the influence of the dose delivered each week. Methods and Materials: For 120 patients, intracavitary brachytherapy was delivered with 33.6 Gy in eight fractions to Point A (HD group), and for 119, intracavitary brachytherapy was delivered with 29.4 Gy in seven fractions to Point A (LD group). The cumulative incidence of severe gastrointestinal and genitourinary late effects were calculated for both dose groups using Kaplan-Meier survival analysis. This method was also used to explore whether the number of weeks with different dose levels could predict the cumulative incidence of late effects. Results: The actuarial rate of developing severe gastrointestinal morbidity at 7 years was 10.7% and 8.3% for HD and LD groups, respectively. The rate for genitourinary morbidity was 6.6% for the HD group and 5.0% for the LD group, respectively. No significant difference was found between the two groups. The analyses showed that a marginally significant increase occurred in severe gastrointestinal complications as the number of weeks with a physical dose >20 Gy increased in the HD group (p = .047). Conclusion: To establish dose-response relationships for late complications, three-dimensional imaging and dose-volume histogram parameters are needed. We found some indications that 20 Gy/wk is an upper tolerance level when the dose to the International Commission on Radiation Units and Measurements rectum point is 81 Gy{sub {alpha}/{beta}=3} (isoeffective [equivalent] dose of 2-Gy fractions). However, additional investigations using three-dimensional data are needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Different Fractionation Schedules Toward a Single Fraction in High-Dose-Rate Brachytherapy as Monotherapy for Low-Risk Prostate Cancer Using 3-Dimensional Radiobiological Models

Purpose: The aim of the present study was the investigation of different fractionation schemes to estimate their clinical impact. For this purpose, widely applied radiobiological models and dosimetric measures were used to associate their results with clinical findings. Methods and Materials: The dose distributions of 12 clinical high-dose-rate brachytherapy implants for prostate were evaluated in relation to different fractionation schemes. The fractionation schemes compared were: (1) 1 fraction of 20 Gy; (2) 2 fractions of 14 Gy; (3) 3 fractions of 11 Gy; and (4) 4 fractions of 9.5 Gy. The clinical effectiveness of the different fractionation schemes was estimated through the complication-free tumor control probability (P{sub +}), the biologically effective uniform dose, and the generalized equivalent uniform dose index. Results: For the different fractionation schemes, the tumor control probabilities were 98.5% in 1 × 20 Gy, 98.6% in 2 × 14 Gy, 97.5% in 3 × 11 Gy, and 97.8% in 4 × 9.5 Gy. The corresponding P{sub +} values were 88.8% in 1 × 20 Gy, 83.9% in 2 × 14 Gy, 86.0% in 3 × 11 Gy, and 82.3% in 4 × 9.5 Gy. With use of the fractionation scheme 4 × 9.5 Gy as reference, the isoeffective schemes regarding tumor control for 1, 2, and 3 fractions were 1 × 19.68 Gy, 2 × 13.75 Gy, and 3 × 11.05 Gy. The optimum fractionation schemes for 1, 2, 3, and 4 fractions were 1 × 19.16 Gy with a P{sub +} of 91.8%, 2 × 13.2 Gy with a P{sub +} of 89.6%, 3 × 10.6 Gy with a P{sub +} of 88.4%, and 4 × 9.02 Gy with a P{sub +} of 86.9%. Conclusions: Among the fractionation schemes 1 × 20 Gy, 2 × 14 Gy, 3 × 11 Gy, and 4 × 9.5 Gy, the first scheme was more effective in terms of P{sub +}. After performance of a radiobiological optimization, it was shown that a single fraction of 19.2 to 19.7 Gy (average 19.5 Gy) should produce at least the same benefit as that given by the 4 × 9.5 Gy scheme, and it should reduce the expected total complication probability by approximately 40% to 55%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Mammographic Changes Across Three Different Fractionation Schedules for Early-Stage Breast Cancer

Purpose: As the use of hypofractionated breast radiation therapy (RT) increases, so will the need for long-term data on post-RT mammographic changes. The purpose of the present study was to longitudinally compare the incidence of common mammographic sequelae seen after breast conserving surgery and RT in patients treated with accelerated partial breast irradiation (APBI), hypofractionated whole breast irradiation (HWBI), and conventionally fractionated whole breast irradiation (WBI). Methods and Materials: Patients treated with either APBI or HWBI after breast conserving therapy and with ≥3 mammograms of the treated breast were identified. They were matched 1:1 by age ±5 years to patients treated with WBI. The mammograms were evaluated for common post-RT breast findings by a mammographer who was unaware of the treatment. The outcomes were analyzed using a cumulative logistic regression model; P<.05 indicated statistically significance. Results: Of 89 patients treated with RT from 2006 to 2011, 29 had received APBI, 30 had received HWBI, and 30 had received WBI. Their median age was 60 years (range 33-83). A total of 605 mammograms were evaluated, with a median follow-up of 48 months. The treatment technique did not affect the severity of architectural distortion when the groups were evaluated longitudinally. The likelihood of finding skin thickening decreased with increasing follow-up duration (odds ratio 0.6; P<.001) adjusted for fractionation schemes. No differences were seen with respect to changes in skin thickening, fluid collections, or calcifications among the treatment groups, after adjustment for the follow-up time. The clinical characteristics, including age, race, T stage, and chemotherapy use, were not linked to the likelihood of finding several mammographic phenomena over time. Conclusions: Although specific post-treatment imaging findings evolved over time, RT fractionation did not alter the relative incidence or severity of architectural distortion, skin thickening, fluid collections, or calcifications. These findings will be useful to both radiologists and radiation oncologists when counseling patients regarding follow-up studies after RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗