Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “refraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Parabolic single-crystal diamond lenses for coherent x-ray imaging

We demonstrate parabolic single-crystal diamond compound refractive lenses designed for coherent x-ray imaging resilient to extreme thermal and radiation loading expected from next generation light sources. To ensure the preservation of coherence and resilience, the lenses are manufactured from the highest-quality single-crystalline synthetic diamond material grown by a high-pressure high-temperature technique. Picosecond laser milling is applied to machine lenses to parabolic with a similar or equal to 1 mu m precision and surface roughness. A compound refractive lens comprised of six lenses with a radius of curvature R = 200 mu m at the vertex of the parabola and a geometrical aperture A = 900 mu m focuses 10 keV x-ray photons from an undulator source at the Advanced Photon Source facility to a focal spot size of similar or equal to 20 x 90 mu m(2) with a gain factor of similar or equal to 50 - 100. (C) 2015 Author(s).

Terentyev, Sergey↗

An x-ray backlit Talbot-Lau deflectometer for high-energy-density electron density diagnostics

X-ray phase-contrast techniques can measure electron density gradients in high-energy-density plasmas through refraction induced phase shifts. An 8 keV Talbot-Lau interferometer consisting of free standing ultrathin gratings was deployed at an ultra-short, high-intensity laser system using K-shell emission from a 1-30 J, 8 ps laser pulse focused on thin Cu foil targets. Grating survival was demonstrated for 30 J, 8 ps laser pulses. The first x-ray deflectometry images obtained under laser backlighting showed up to 25% image contrast and thus enabled detection of electron areal density gradients with a maximum value of 8.1 ± 0.5 × 10 23 cm ₋3 in a low-Z millimeter sized sample. An electron density profile was obtained from refraction measurements with an error of <8%. We found the 50 ± 15 μm spatial resolution achieved across the full field of view was limited by the x-ray source-size, similar to conventional radiography.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Hard x-ray nanoprobe of beamline P06 at PETRA III

The hard x-ray scanning microscope at beamline P06 of PETRA III at DESY in Hamburg serves a large user community, from physics, chemistry, and nanotechnology to the bio-medical, materials, environmental, and geosciences. It has been in user operation since 2012, and is mainly based on nanofocusing refractive x-ray lenses. Using refractive optics, nearly gaussian-limited nanobeams in the range from 50 to 100 nm can be generated in the hard x-ray energy range from 8 to 30 keV. The degree of coherence can be traded off against the flux in the nanobeam by a two-stage focusing scheme. We give a brief overview on published results from this instrument and describe its most important components and parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The life science x-ray scattering beamline at NSLS-II

We report the current development status of the High Brightness X-ray Scattering for Life Sciences (or Life Science X-ray Scattering, LiX) beamline at the NSLS-II facility of Brookhaven National Laboratory. This instrument will operate in the x-ray energy range of 2.1-18 keV, provide variable beam sizes from 1 micron to ∼0.5 mm, and support user experiments in three scientific areas: (1) high-throughput solution scattering, in-line size exclusion chromatography and flow mixers-based time-resolved solution scattering of biological macro-molecules, (2) diffraction from single- and multi-layered lipid membranes, and (3) scattering-based scanning probe imaging of biological tissues. In order to satisfy the beam stability required for these experiments and to switch rapidly between different types of experiments, we have adopted a secondary source with refractive lenses for secondary focusing, a detector system consisting of three Pilatus detectors, and specialized experimental modules that can be quickly exchanged and each dedicated to a defined set of experiments. The construction of this beamline is on schedule for completion in September 2015. User experiments are expected to start in Spring 2016.

43 PARTICLE ACCELERATORS↗

Synthetic diagnostics platform for fusion plasmas (invited)

A Synthetic Diagnostics Platform (SDP) for fusion plasmas has been developed which provides state of the art synthetic reflectometry, beam emission spectroscopy, and Electron Cyclotron Emission (ECE) diagnostics. Interfaces to the plasma simulation codes GTC, XGC-1, GTS, and M3D-C{sup 1} are provided, enabling detailed validation of these codes. In this paper, we give an overview of SDP’s capabilities, and introduce the synthetic diagnostic modules. A recently developed synthetic ECE Imaging module which self-consistently includes refraction, diffraction, emission, and absorption effects is discussed in detail. Its capabilities are demonstrated on two model plasmas. The importance of synthetic diagnostics in validation is shown by applying the SDP to M3D-C{sup 1} output and comparing it with measurements from an edge harmonic oscillation mode on DIII-D.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large tuning of narrow-beam terahertz plasmonic lasers operating at 78 K

A new tuning mechanism is demonstrated for single-mode metal-clad plasmonic lasers, in which the refractive-index of the laser’s surrounding medium affects the resonant-cavity mode in the same vein as the refractive-index of gain medium inside the cavity. Reversible, continuous, and mode-hop-free tuning of ~57 GHz is realized for single-mode narrow-beam terahertz plasmonic quantum-cascade lasers (QCLs), which is demonstrated at a much more practical temperature of 78 K. The tuning is based on post-process deposition/etching of a dielectric (silicon-dioxide) on a QCL chip that has already been soldered and wire-bonded onto a copper mount. This is a considerably larger tuning range compared to previously reported results for terahertz QCLs with directional far-field radiation patterns. The key enabling mechanism for tuning is a recently developed antenna-feedback scheme for plasmonic lasers, which leads to the generation of hybrid surface-plasmon-polaritons propagating outside the cavity of the laser with a large spatial extent. The effect of dielectric deposition on QCL’s characteristics is investigated in detail including that on maximum operating temperature, peak output power, and far-field radiation patterns. Single-lobed beam with low divergence (<7°) is maintained through the tuning range. The antenna-feedback scheme is ideally suited for modulation of plasmonic lasers and their sensing applications due to the sensitive dependence of spectral and radiative properties of the laser on its surrounding medium.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma and radiation detection via fiber interferometry

Photonic Doppler velocimetry tracks motion during high-speed, single-event experiments using telecommunication fiber components. The same technology can be applied in situations where there is no actual motion, but rather a change in the optical path length. Migration of plasma into vacuum alters the refractive index near a fiber probe, while intense radiation modifies the refractive index of the fiber itself. Lastly, these changes can diagnose extreme environments in a flexible, time-resolved manner.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optical constants of magnetron sputtered Pt thin films with improved accuracy in the N- and O-electronic shell absorption regions

We introduce an experimental, self-consistent determination of the optical constants (refractive index) of Pt using a combination of photoabsorption and reflectance data in the photon energy range 25–778 eV, which includes the N- and O-shell electronic absorption edges of Pt. We compare our new experimental values with Pt optical constant data sets from the literature. Our Pt optical constant values demonstrate highly resolved absorption-edge fine structure around the O 2,3 and N 6,7 edges in both the absorptive and dispersive portions of the refractive index, which were missing in the earlier literature.

36 MATERIALS SCIENCE↗

Single shot high bandwidth laser plasma probe

Herein a novel scheme to probe a plasma's ion acoustic resonances in single shot high-bandwidth pump-probe experiments is proposed. Our design utilizes concepts similar to smoothing by spectral dispersion; however, we propose a method of applying the bandwidth to the probe that avoids the effects of angular dispersion. Theoretical modeling and fluid simulations of the interaction are presented and compared. The results show the possibility of recovering a plasma's full complex index of refraction in a single shot pump-probe experiment. This wavelength dependent refractive index is directly related to the plasma's particle distribution function and can be used to recover plasma parameters including electron and ion temperatures, electron density, and plasma flow velocity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Implementation of Talbot–Lau x-ray deflectometry in the pulsed power environment using a copper X-pinch backlighter

A Talbot–Lau x-ray deflectometer can map electron density gradients in high energy density plasmas, as well as provide information about plasma elemental composition through single-image x-ray refraction and attenuation measurements. A new adaptation to a pulsed power environment used backlighting from copper X-pinches, allowing for electron density mapping of a low-Z object. Even though the X-pinch backlighter is not properly optimized for emitting x-rays in terms of source size and photon fluence, Moire fringe patterns with contrast up to 14% and fringe shift due to refraction on a beryllium object are obtained. Due to the proximity of the deflectometer with the X-pinch (~6 cm), it is shown that a protective filter is required to avoid damage in the closest (i.e., source) grating due to both plasma debris and mechanical shock. Regarding grating survival, these did not show any damage due to the intense magnetic field or heating induced by plasma radiation. Electron density on beryllium was measured with a difference lower than 16%. The areal electron density mapping of the sample was limited by source size characteristics, in similarity to transmission radiography. These results show the potential of plasma electron density as well as material mapping through Talbot–Lau x-ray deflectometry in a pulsed power environment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Compositional dependence of linear and nonlinear optical response in crystalline hafnium zirconium oxide thin films

Composition dependence of second harmonic generation, refractive index, extinction coefficient, and optical bandgap in 20 nm thick crystalline Hf 1– x Zr x O 2 (0 ≤ x ≤ 1) thin films is reported here. The refractive index exhibits a general increase with increasing ZrO 2 content with all values within the range of 1.98–2.14 from 880 nm to 400 nm wavelengths. A composition dependence of the indirect optical bandgap is observed, decreasing from 5.81 eV for HfO 2 to 5.17 eV for Hf 0.4 Zr 0.6 O 2 . The bandgap increases for compositions with x > 0.6, reaching 5.31 eV for Hf 0.1 Zr 0.9 O 2 . Second harmonic signals are measured for 880 nm incident light. The magnitude of the second harmonic signal scales with the magnitude of the remanant polarization in the composition series. Film compositions that display near zero remanent polarizations exhibit minimal second harmonic generation while those with maximum remanent polarization also display the largest second harmonic signal. The results are discussed in the context of ferroelectric phase assemblage in the hafnium zirconium oxide films and demonstrate a path toward a silicon-compatible integrated nonlinear optical material.

36 MATERIALS SCIENCE↗

X-ray phase contrast and absorption imaging for the quantification of transient cavitation in high-speed nozzle flows

In this work, high-flux synchrotron radiation has been employed in a time-resolved manner to characterise the distinct topology features and dynamics of different cavitation regimes arising in a throttle orifice with an abrupt flow-entry contraction. Radiographs obtained though both X-ray phase- contrast and absorption imaging have been captured at 67,890 frames per second. The flow lied in the turbulent regime (Re=35,500), while moderate (CN=2.0) to well-established (CN=6.0) cavitation conditions were examined encompassing the cloud and vortical cavitation regimes with pertinent transient features, such as cloud-cavity shedding. X-ray Phase-Contrast Imaging (XPCI), exploiting the shift in the X-ray wave phase during interactions with matter, offers sharp-refractive index gradients in the interface region. Hence, it is suitable for capturing fine morphological fluctuations of transient cavitation structures. Nevertheless, the technique cannot provide information on the quantity of vapour within the orifice. Such data have been obtained utilising absorption imaging, where beam attenuation is not associated with scattering and refraction events, and hence can be explicitly correlated with the projected vapour thickness in line-of-sight measurements. A combination of the two methods is proposed, as it has been found is capable of quantifying the vapour content arising in the complex nozzle flow, while also faithfully illustrating the dynamics of the highly-transient cavitation features.

42 ENGINEERING↗

Observation of a highly conductive warm dense state of water with ultrafast pump–probe free-electron-laser measurements

The electrical conductivity of water under extreme temperatures and densities plays a central role in modeling planetary magnetic fields. Experimental data are vital to test theories of high-energy-density water and assess the possible development and presence of extraterrestrial life. These states are also important in biology and chemistry studies when specimens in water are confined and excited using ultrafast optical or free-electron lasers (FELs). Here we utilize femtosecond optical lasers to measure the transient reflection and transmission of ultrathin water sheet samples uniformly heated by a 13.6 nm FEL approaching a highly conducting state at electron temperatures exceeding 20 000 K. The experiment probes the trajectory of water through the high-energy-density phase space and provides insights into changes in the index of refraction, charge carrier densities, and AC electrical conductivity at optical frequencies. At excitation energy densities exceeding 10 MJ/kg, the index of refraction falls to n = 0.7, and the thermally excited free-carrier density reaches ne = 5 × 1027 m−3, which is over an order of magnitude higher than that of the electron carriers produced by direct photoionization. Significant specular reflection is observed owing to critical electron density shielding of electromagnetic waves. The measured optical conductivity reaches 2 × 104 S/m, a value that is one to two orders of magnitude lower than those of simple metals in a liquid state. At electron temperatures below 15 000 K, the experimental results agree well with the theoretical calculations using density-functional theory/molecular-dynamics simulations. With increasing temperature, the electron density increases and the system approaches a Fermi distribution. In this regime, the conductivities agree better with predictions from the Ziman theory of liquid metals.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modeling the spectral modification of lower hybrid wave in the presence of drift-wave type density fluctuation in the scrape-off-layer of the EAST tokamak

In this work, the spectrum change of the lower hybrid (LH) waves caused by a low-frequency density fluctuation in the scrape-off-layer is studied by applying the wave scattering model developed by Bonoli and Ott [Phys. Fluids 25, 359 (1982)] via a Monte Carlo method. A ray-tracing model specific to this purpose is developed to evaluate the probability distribution of both the poloidal refractive index (N θ ) and the parallel refractive index (N ∥ ) of the LH wave at the last closed flux surface (LCFS).The probability distributions of N ∥ and N θ at the LCFS are studied using the EAST parameters as a function of wave frequency, the initial N ∥ , and the polar injection position, which may influence the lower hybrid current drive efficiency.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-order ( N = 4–6) multiphoton absorption and mid-infrared Kerr nonlinearity in GaP, ZnSe, GaSe, and ZGP crystals

We report a study of high-order multiphoton absorption, nonlinear refraction, and their anisotropy in four notable mid-infrared χ (2) crystals: GaP, ZnSe, GaSe, and ZGP using femtosecond pulses at 2.35 μm with peak intensity in excess of 200 GW/cm 2 . We found that the nonlinear absorption obeys a perturbation model with multiphoton absorption (MPA) orders from N = 4–6, in agreement with the bandgaps of the crystals. A study of the role of free carrier absorption, performed by changing the pulse duration from 30 to 70 fs while maintaining a constant peak intensity, showed that, at our intensity levels, free carriers generated during the MPA process absorb much more strongly than would be expected from their known linear absorption cross section. Possible mechanisms for this anomalous behavior are high-field effects, such as intravalley scattering in the conduction band and absorption to higher lying bands. Nonlinear refractive indices were measured using (i) closed aperture Z-scan and (ii) spectral broadening due to self-phase modulation, both methods agreeing with each other.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simulating the filamentation of smoothed laser beams with three-dimensional nonlinear dynamics

In a plasma, the ponderomotive force of an inhomogeneous electromagnetic field expels plasma from regions of high intensity. When a laser propagates through a plasma, this force creates density wells that subsequently modify the index of refraction. The beam refracts and focuses into these wells and may filament. In extreme cases, the laser beam will spray due to increasing angular divergence of the beam. The threshold for ponderomotive self-focusing is well established for isolated laser hotspots or speckles. Here, we define a practical threshold for characterizing the filamentation of thousands of speckles that are found in the focal plane of high-power laser beams spatially smoothed with random phase plates as used at high energy and power laser facilities studying inertial confinement fusion. This threshold is tested against three-dimensional simulations of speckled laser light propagating through plasma. Four metrics are applied to assess filamentation: the fraction of power above five times the average intensity, an effective f-number, the mean-squared perpendicular wavenumber, and the fraction of rarefied density with deviation from the initial density exceeding | δn/ n| = 0.1. The speckled beams studied are generated by random phase plates, both with and without additional polarization smoothing, in a parameter regime of relevance to indirect drive experiments. While filamentation has been discussed extensively in the literature, we believe this to be the first published simulation study with three-dimensional nonlinear hydrodynamics that addresses the onset threshold of ponderomotive filamentation and establishes the lengths and time scales necessary to reach a statistical steady state.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Current advances on Talbot–Lau x-ray imaging diagnostics for high energy density experiments (invited)

Talbot–Lau x-ray interferometry is a refraction-based diagnostic that can map electron density gradients through phase-contrast methods. The Talbot–Lau x-ray deflectometry (TXD) diagnostics have been deployed in several high energy density experiments. To improve diagnostic performance, a monochromatic TXD was implemented on the Multi-Tera Watt (MTW) laser using 8 keV multilayer mirrors (Δθ/θ = 4.5%-5.6%). Copper foil and wire targets were irradiated at 10 14 –10 15 W/cm 2 . Laser pulse length (~10 to 80 ps) and backlighter target configurations were explored in the context of Moiré fringe contrast and spatial resolution. Foil and wire targets delivered increased contrast <30%. The best spatial resolution (<6 μm) was measured for foils irradiated 80° from the surface. Further TXD diagnostic capability enhancement was achieved through the development of advanced data postprocessing tools. The Talbot Interferometry Analysis (TIA) code enabled x-ray refraction measurements from the MTW monochromatic TXD. Additionally, phase, attenuation, and dark-field maps of an ablating x-pinch load were retrieved through TXD. The images show a dense wire core of ~60 μm diameter surrounded by low-density material of ~40 μm thickness with an outer diameter ratio of ~2.3. Attenuation at 8 keV was measured at ~20% for the dense core and ~10% for the low-density material. Instrumental and experimental limitations for monochromatic TXD diagnostics are presented. Enhanced postprocessing capabilities enabled by TIA are demonstrated in the context of high-intensity laser and pulsed power experimental data analysis. Significant advances in TXD diagnostic capabilities are presented. Furthermore, these results inform future diagnostic technique upgrades that will improve the accuracy of plasma characterization through TXD.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nonlinear optical properties of lanthanum titanate glasses prepared by levitation melting

Lanthanum titanate glasses (17 La 2 O 3 -83 TiO 2 ) are fabricated via aerodynamic levitation melting. Here, nonlinear refraction and absorption were measured with the Z scan technique using ps optical pulses at 532 nm wavelength with peak intensities in the range of 0.25–2.5 GW/cm 2 . The two-photon absorption coefficient (β) and the effective nonlinear refraction coefficient (⁠$n^{eff}_{2}$) are found to be, respectively, 2.19 cm/GW and 152 × 10 -16 cm 2 /W (85 × 10 -13 esu). The Raman gain is measured to be 106 × 10 -11 cm/W. The nonlinearity strength is found to be nearly 60 times larger in lanthanum titanate glasses relative to silica.

36 MATERIALS SCIENCE↗