Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantum imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Reconstruction of a cone-beam CT image via forward iterative projection matching

Purpose: To demonstrate the feasibility of reconstructing a cone-beam CT (CBCT) image by deformably altering a prior fan-beam CT (FBCT) image such that it matches the anatomy portrayed in the CBCT projection data set. Methods: A prior FBCT image of the patient is assumed to be available as a source image. A CBCT projection data set is obtained and used as a target image set. A parametrized deformation model is applied to the source FBCT image, digitally reconstructed radiographs (DRRs) that emulate the CBCT projection image geometry are calculated and compared to the target CBCT projection data, and the deformation model parameters are adjusted iteratively until the DRRs optimally match the CBCT projection data set. The resulting deformed FBCT image is hypothesized to be an accurate representation of the patient's anatomy imaged by the CBCT system. The process is demonstrated via numerical simulation. A known deformation is applied to a prior FBCT image and used to create a synthetic set of CBCT target projections. The iterative projection matching process is then applied to reconstruct the deformation represented in the synthetic target projections; the reconstructed deformation is then compared to the known deformation. The sensitivity of the process to the number of projections and the DRR/CBCT projection mismatch is explored by systematically adding noise to and perturbing the contrast of the target projections relative to the iterated source DRRs and by reducing the number of projections. Results: When there is no noise or contrast mismatch in the CBCT projection images, a set of 64 projections allows the known deformed CT image to be reconstructed to within a nRMS error of 1% and the known deformation to within a nRMS error of 7%. A CT image nRMS error of less than 4% is maintained at noise levels up to 3% of the mean projection intensity, at which the deformation error is 13%. At 1% noise level, the number of projections can be reduced to 8 while maintaining CT image and deformation errors of less than 4% and 13%, respectively. The method is sensitive to contrast mismatch between the simulated projections and the target projections when the soft-tissue contrast in the projections is low. Conclusions: By using prior knowledge available in a FBCT image, the authors show that a CBCT image can be iteratively reconstructed from a comparatively small number of projection images, thus saving acquisition time and reducing imaging dose. This will enable more frequent daily imaging during radiation therapy. Because the process preserves the CT numbers of the FBCT image, the resulting 3D image intensities will be more accurate than a CBCT image reconstructed via conventional backprojection methods. Reconstruction errors are insensitive to noise at levels beyond what would typically be found in CBCT projection data, but are sensitive to contrast mismatch errors between the CBCT projection data and the DRRs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Features of Construction of the Fluorescent Microscope for the Study of Epithelial-Mesenchymal Transition of Cells in Vitro

An optical luminescent microscope has been developed to monitor the behavior of tumor cells that were modified by GFP and RFP fluorescent proteins and to monitor the formation of metastases in biochips. Images of cells in the light of GFP and RFP fluorescence proteins, as well as in the photography mode, are recorded in the microscope by an noncooled CMOS matrix at the excitation of luminescence by blue and green LEDs and illumination of cells with white LEDs, respectively. The obtained fluorescent images and photos in white light are recorded by the matrix in the same coordinate system and do not require additional processing for combination. The power of irradiation of cells with LEDs does not exceed 50 μW/mm{sup 2} at an exposure time of 1 s, which is an order of magnitude lower than the radiation power causing photodestruction and phototoxicity of cells during long-term studies. Relative parameters of the optical channel of the luminescent microscope have been introduced that allow comparing the sensitivity of the recording system and the minimum power level of the radiation that excites luminescence for optical elements with different spectral characteristics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimizing the formation of depth-confined nitrogen vacancy center spin ensembles in diamond for quantum sensing

Spin ensembles of nitrogen vacancy (NV) centers in diamond are emerging as powerful spin-based sensors for magnetic, electric and thermal field imaging with high spatial and temporal resolution. In this work, we characterize the formation of depth-confined NV center ensembles, activated by electron irradiation in diamond layers grown by plasma enhanced chemical vapor deposition with nitrogen co-doping. To do so, we exploit the high magnetic sensitivity of ensembles of NV centers to probe their spin environment as a function of growth and irradiation parameters. We engineer an NV ensemble whose magnetic sensitivity is within a factor of two of the static NV-NV dipolar interaction limit, thus demonstrating a powerful platform for quantum sensing.

36 MATERIALS SCIENCE↗

Mutual capacitance of liquid conductors in deformable tactile sensing arrays

Advances in highly deformable electronics are needed in order to enable emerging categories of soft computing devices ranging from wearable electronics, to medical devices, and soft robotic components. The combination of highly elastic substrates with intrinsically stretchable conductors holds the promise of enabling electronic sensors that can conform to curved objects, reconfigurable displays, or soft biological tissues, including the skin. Here, we contribute sensing principles for tactile (mechanical image) sensors based on very low modulus polymer substrates with embedded liquid metal microfluidic arrays. The sensors are fabricated using a single-step casting method that utilizes fine nylon filaments to produce arrays of cylindrical channels on two layers. The liquid metal (gallium indium alloy) conductors that fill these channels readily adopt the shape of the embedding membrane, yielding levels of deformability greater than 400%, due to the use of soft polymer substrates. We modeled the sensor performance using electrostatic theory and continuum mechanics, yielding excellent agreement with experiments. Using a matrix-addressed capacitance measurement technique, we are able to resolve strain distributions with millimeter resolution over areas of several square centimeters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lagrangian formulation of irreversible thermodynamics and the second law of thermodynamics

We show that the equations which describe irreversible evolution of a system can be derived from a variational principle. We suggest a Lagrangian, which depends on the properties of the normal and the so-called “mirror-image” system. The Lagrangian is symmetric in time and therefore compatible with microscopic reversibility. The evolution equations in the normal and mirror-imaged systems are decoupled and describe therefore independent irreversible evolution of each of the systems. The second law of thermodynamics follows from a symmetry of the Lagrangian. Entropy increase in the normal system is balanced by the entropy decrease in the mirror-image system, such that there exists an “integral of evolution” which is a constant. The derivation relies on the property of local equilibrium, which states that the local relations between the thermodynamic quantities in non-equilibrium are the same as in equilibrium.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Complex-valued acquisition of the diffraction imaging by incoherent quasimonochromatic light without a support constraint

A scheme for complex-valued acquisition of the diffraction imaging with quasimonochromatic incoherent light is theoretically proposed. The main idea is to project the real and the imaginary parts of a Fraunhofer diffraction field on intensity distributions, respectively, with the use of a {pi}/2 phase-changing plate. The whole procedure is iterative algorithm free and needs no a priori knowledge of an arbitrary object. A numerical experiment and a quantitative confirmation are also given. To our knowledge, it was the first physical proposal for the complex-valued acquisition of a diffraction imaging by two-dimensional coherent patterns with thermal illumination.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Imaging exciton–polariton transport in MoSe2 waveguides

The exciton polariton (EP), a half-light and half-matter quasiparticle, is potentially an important element for future photonic and quantum technologies1-4. It provides both strong light-matter interactions and long-distance propagation that is necessary for applications associated with energy or information transfer. Recently, strongly-coupled cavity EPs at room temperature have been demonstrated in van der Waals (vdW) materials due to their strongly-bound excitons5-9. Here we report a nano-optical imaging study of waveguide EPs in MoSe2, a prototypical vdW semiconductor. The measured propagation length of the EPs is sensitive to the excitation photon energy and reaches over 12 μm. The polariton wavelength can be conveniently altered from 600 nm down to 300 nm by controlling the waveguide thickness. Furthermore, we found an intriguing back-bending polariton dispersion close to the exciton resonance. The observed EPs in vdW semiconductors could be useful in future nanophotonic circuits operating in the near-infrared to visible spectral regions.

36 MATERIALS SCIENCE↗

A robust geometry estimation method for spiral, sequential and circular cone-beam micro-CT

Purpose: The authors propose a novel method for misalignment estimation of micro-CT scanners using an adaptive genetic algorithm. Methods: The proposed algorithm is able to estimate the rotational geometry, the direction vector of table movement and the displacement between different imaging threads of a dual source or even multisource scanner. The calibration procedure does not rely on dedicated calibration phantoms and a sequence scan of a single metal bead is sufficient to geometrically calibrate the whole imaging system for spiral, sequential, and circular scan protocols. Dual source spiral and sequential scan protocols in micro-computed tomography result in projection data that-besides the source and detector positions and orientations-also require a precise knowledge of the table direction vector to be reconstructed properly. If those geometric parameters are not known accurately severe artifacts and a loss in spatial resolution appear in the reconstructed images as long as no geometry calibration is performed. The table direction vector is further required to ensure that consecutive volumes of a sequence scan can be stitched together and to allow the reconstruction of spiral data at all. Results: The algorithm's performance is evaluated using simulations of a micro-CT system with known geometry and misalignment. To assess the quality of the algorithm in a real world scenario the calibration of a micro-CT scanner is performed and several reconstructions with and without geometry estimation are presented. Conclusions: The results indicate that the algorithm successfully estimates all geometry parameters, misalignment artifacts in the reconstructed volumes vanish, and the spatial resolution is increased as can be shown by the evaluation of modulation transfer function measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Extreme ultra-violet burst, particle heating, and whistler wave emission in fast magnetic reconnection induced by kink-driven Rayleigh-Taylor instability

A spatially localized energetic extreme ultra-violet (EUV) burst is imaged at the presumed position of fast magnetic reconnection in a plasma jet produced by a coaxial helicity injection source; this EUV burst indicates strong localized electron heating. A circularly polarized high frequency magnetic field perturbation is simultaneously observed at some distance from the reconnection region indicating that the reconnection emits whistler waves and that Hall dynamics likely governs the reconnection. Spectroscopic measurement also shows simultaneous fast ion heating. The electron heating is consistent with Ohmic dissipation, while the ion heating is consistent with ion trajectories becoming stochastic.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Location deterministic biosensing from quantum-dot-nanowire assemblies

Semiconductor quantum dots (QDs) with high fluorescent brightness, stability, and tunable sizes, have received considerable interest for imaging, sensing, and delivery of biomolecules. In this research, we demonstrate location deterministic biochemical detection from arrays of QD-nanowire hybrid assemblies. QDs with diameters less than 10 nm are manipulated and precisely positioned on the tips of the assembled Gold (Au) nanowires. The manipulation mechanisms are quantitatively understood as the synergetic effects of dielectrophoretic (DEP) and alternating current electroosmosis (ACEO) due to AC electric fields. The QD-nanowire hybrid sensors operate uniquely by concentrating bioanalytes to QDs on the tips of nanowires before detection, offering much enhanced efficiency and sensitivity, in addition to the position-predictable rationality. This research could result in advances in QD-based biomedical detection and inspires an innovative approach for fabricating various QD-based nanodevices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Observation of emission process in hydrogen-like nitrogen Z-pinch discharge with time integrated soft X-ray spectrum pinhole image

The emission spectra of hydrogen-like nitrogen Balmer at the wavelength of 13.4 nm in capillary Z-pinch discharge plasma are experimentally examined. Ionization to fully strip nitrogen at the pinch maximum, and subsequent rapid expansion cooling are required to establish the population inversion between the principal quantum number of n = 2 and n = 3. The ionization and recombination processes with estimated plasma parameters are evaluated by utilizing a time integrated spectrum pinhole image containing radial spatial information. A cylindrical capillary plasma is pinched by a triangular pulsed current with peak amplitude of 50 kA and pulse width of 50 ns.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Validation of velocity map imaging conditions over larger areas

We have established through simulations and experiments the area over which Velocity Map Imaging (VMI) conditions prevail. We designed a VMI setup in which we can vary the ionization position perpendicular to the center axis of the time-of-flight spectrometer. We show that weak extraction conditions are far superior over standard three-plate setups if the aim is to increase the ionization volume without distorting VMI conditions. This is important for a number of crossed molecular beam experiments that already utilize weak extraction conditions, but to a greater extent for surface studies where fragments are desorbed or scattered off a surface in all directions. Our results on the dissociation of NO{sub 2} at 226 nm show that ionization of the fragments can occur up to {+-}5.5 mm away from the center axis of the time-of-flight spectrometer without affecting resolution or arrival position.

43 PARTICLE ACCELERATORS↗

Generation of a suite of 3D computer-generated breast phantoms from a limited set of human subject data

Purpose: The authors previously reported on a three-dimensional computer-generated breast phantom, based on empirical human image data, including a realistic finite-element based compression model that was capable of simulating multimodality imaging data. The computerized breast phantoms are a hybrid of two phantom generation techniques, combining empirical breast CT (bCT) data with flexible computer graphics techniques. However, to date, these phantoms have been based on single human subjects. In this paper, the authors report on a new method to generate multiple phantoms, simulating additional subjects from the limited set of original dedicated breast CT data. The authors developed an image morphing technique to construct new phantoms by gradually transitioning between two human subject datasets, with the potential to generate hundreds of additional pseudoindependent phantoms from the limited bCT cases. The authors conducted a preliminary subjective assessment with a limited number of observers (n= 4) to illustrate how realistic the simulated images generated with the pseudoindependent phantoms appeared. Methods: Several mesh-based geometric transformations were developed to generate distorted breast datasets from the original human subject data. Segmented bCT data from two different human subjects were used as the 'base' and 'target' for morphing. Several combinations of transformations were applied to morph between the 'base' and 'target' datasets such as changing the breast shape, rotating the glandular data, and changing the distribution of the glandular tissue. Following the morphing, regions of skin and fat were assigned to the morphed dataset in order to appropriately assign mechanical properties during the compression simulation. The resulting morphed breast was compressed using a finite element algorithm and simulated mammograms were generated using techniques described previously. Sixty-two simulated mammograms, generated from morphing three human subject datasets, were used in a preliminary observer evaluation where four board certified breast radiologists with varying amounts of experience ranked the level of realism (from 1 ='fake' to 10 ='real') of the simulated images. Results: The morphing technique was able to successfully generate new and unique morphed datasets from the original human subject data. The radiologists evaluated the realism of simulated mammograms generated from the morphed and unmorphed human subject datasets and scored the realism with an average ranking of 5.87 {+-} 1.99, confirming that overall the phantom image datasets appeared more 'real' than 'fake.' Moreover, there was not a significant difference (p > 0.1) between the realism of the unmorphed datasets (6.0 {+-} 1.95) compared to the morphed datasets (5.86 {+-} 1.99). Three of the four observers had overall average rankings of 6.89 {+-} 0.89, 6.9 {+-} 1.24, 6.76 {+-} 1.22, whereas the fourth observer ranked them noticeably lower at 2.94 {+-} 0.7. Conclusions: This work presents a technique that can be used to generate a suite of realistic computerized breast phantoms from a limited number of human subjects. This suite of flexible breast phantoms can be used for multimodality imaging research to provide a known truth while concurrently producing realistic simulated imaging data.

60 APPLIED LIFE SCIENCES↗

Superior photo-carrier diffusion dynamics in organic-inorganic hybrid perovskites revealed by spatiotemporal conductivity imaging

Abstract The outstanding performance of organic-inorganic metal trihalide solar cells benefits from the exceptional photo-physical properties of both electrons and holes in the material. Here, we directly probe the free-carrier dynamics in Cs-doped FAPbI 3 thin films by spatiotemporal photoconductivity imaging. Using charge transport layers to selectively quench one type of carriers, we show that the two relaxation times on the order of 1 μs and 10 μs correspond to the lifetimes of electrons and holes in FACsPbI 3 , respectively. Strikingly, the diffusion mapping indicates that the difference in electron/hole lifetimes is largely compensated by their disparate mobility. Consequently, the long diffusion lengths (3~5 μm) of both carriers are comparable to each other, a feature closely related to the unique charge trapping and de-trapping processes in hybrid trihalide perovskites. Our results unveil the origin of superior diffusion dynamics in this material, crucially important for solar-cell applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of tunable electromagnetic band gap material with disordered cavity resonator for X band imaging applications by resistive devices

Electromagnetic band gap (EBG) integrated monopole antenna is investigated in deformed cavity resonator in this study. The operation frequency is chosen as X band frequency regime and designs are completed for this frequency. Firstly, a square grounded monopole antenna is designed and analytically examined, then EBG grounded monopole is designed and tested. After that operation, an 8 cm × 8 cm × 8 cm cubic cavity resonator designed and antennas are examined in it. Moreover, a cuboid deformation is added in one corner of metallic cavity resonator to perturb rectangular eigenmodes. Also, tunability of this structure is tested by various resistive lumped elements, and according to results, resonance shifting and magnitude changes are obtained. This suggested structure is also an adjustable impedance surface and can be used in sensing, detection and microwave imaging applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Distortion-free magnetic resonance imaging in the zero-field limit

MRI is a powerful technique for clinical diagnosis and materials characterization. Images are acquired in a homogeneous static magnetic field much higher than the fields generated across the field of view by the spatially encoding field gradients. Without such a high field, the concomitant components of the field gradient dictated by Maxwell's equations lead to severe distortions that make imaging impossible with conventional MRI encoding. In this paper, we present a distortion-free image of a phantom acquired with a fundamentally different methodology in which the applied static field approaches zero. Our technique involves encoding with pulses of uniform and gradient field, and acquiring the magnetic field signals with a SQUID. The method can be extended to weak ambient fields, potentially enabling imaging in the Earth's field without cancellation coils or shielding. Other potential applications include quantum information processing and fundamental studies of long-range ferromagnetic interactions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ultrafast supercontinuum fiber-laser based pump-probe scanning magneto-optical Kerr effect microscope for the investigation of electron spin dynamics in semiconductors at cryogenic temperatures with picosecond time and micrometer spatial resolution

We describe a two-color pump-probe scanning magneto-optical Kerr effect microscope which we have developed to investigate electron spin phenomena in semiconductors at cryogenic temperatures with picosecond time and micrometer spatial resolution. The key innovation of our microscope is the usage of an ultrafast “white light” supercontinuum fiber-laser source which provides access to the whole visible and near-infrared spectral range. Our Kerr microscope allows for the independent selection of the excitation and detection energy while avoiding the necessity to synchronize the pulse trains of two separate picosecond laser systems. The ability to independently tune the pump and probe wavelength enables the investigation of the influence of excitation energy on the optically induced electron spin dynamics in semiconductors. We demonstrate picosecond real-space imaging of the diffusive expansion of optically excited electron spin packets in a (110) GaAs quantum well sample to illustrate the capabilities of the instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High power THz sources for nonlinear imaging

Many biological and chemical compounds have unique absorption features in the THz (0.1 - 10 THz) region, making the use of THz waves attractive for imaging in defense, security, biomedical imaging, and monitoring of industrial processes. Unlike optical radiation, THz frequencies can pass through many substances such as paper, clothing, ceramic, etc. with little attenuation. The use of currently available THz systems is limited by lack of highpower, sources as well as sensitive detectors and detector arrays operating at room temperature. Here we present a novel, high power THz source based on intracavity downconverison of optical pulses. The source delivers 6 ps pulses at 1.5 THz, with an average power of >300 μW and peak powers >450 mW. We propose an imaging method based on frequency upconverison that is ideally suited to use the narrow bandwidth and high peak powers produced by the source. By upconverting the THz image to the infrared, commercially available detectors can be used for real time imaging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗