Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “process quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Piezoelectric properties of K{sub 4}CuNb{sub 8}O{sub 23} modified (Na{sub 0.5}K{sub 0.5})NbO{sub 3} lead-free piezoceramics

Dense K{sub 4}CuNb{sub 8}O{sub 23} modified (Na{sub 0.5}K{sub 0.5})NbO{sub 3} (NKN:KCN) ceramics were synthesized by using conventional oxide mixing process. The maximum mechanical quality factor Q{sub m} of NKN:KCN ceramics reaches up to 1150, the piezoelectric constant d{sub 33} and the planar electromechanical coefficient k{sub p} still maintain relatively high levels, which are about 100 pC/N and 40%, respectively. Middle frequency (455 kHz) lead-free resonators were fabricated by using NKN:KCN, and remarkable improvements in resonance characteristics were found by KCN doping.

36 MATERIALS SCIENCE↗

GaSb-based, 2.2 {mu}m type-I laser fabricated on GaAs substrate operating continuous wave at room temperature

We report on a Sb-based type-I laser grown on GaAs substrate, emitting continuous wave at room temperature around 2.2 {mu}m. The device was grown using solid-source molecular beam epitaxy and comprised two GaInAsSb quantum wells embedded in AlGaAsSb barriers. Despite the large lattice mismatch, a good crystalline quality was obtained, and processed devices operated continuous wave up to 50 deg. C with threshold current densities in the range of 1.5-2.2 kA/cm{sup 2}. An optical output power of 3.7 mW was obtained at 20 deg. C.

36 MATERIALS SCIENCE↗

Strain relaxation of thin Si{sub 0.6}Ge{sub 0.4} grown with low-temperature buffers by molecular beam epitaxy

A double-low-temperature-buffer variable-temperature growth scheme was studied for fabrication of strain-relaxed thin Si{sub 0.6}Ge{sub 0.4} layer on Si(001) by using molecular beam epitaxy (MBE), with particular focuses on the influence of growth temperature of individual low-temperature-buffer layers on the relaxation process and final structural qualities. The low-temperature buffers consisted of a 40 nm Si layer grown at an optimized temperature of {approx}400 deg. C, followed by a 20 nm Si{sub 0.6}Ge{sub 0.4} layer grown at temperatures ranging from 50 to 550 deg. C. A significant relaxation increase together with a surface roughness decrease both by a factor of {approx}2, accompanied with the cross-hatch/cross-hatch-free surface morphology transition, took place for the sample containing a low-temperature Si{sub 0.6}Ge{sub 0.4} layer that was grown at {approx}200 deg. C. This dramatic change was explained by the association with a certain onset stage of the ordered/disordered growth transition during the low-temperature MBE, where the high density of misfit dislocation segments generated near surface cusps largely facilitated the strain relaxation of the top Si{sub 0.6}Ge{sub 0.4} layer.

36 MATERIALS SCIENCE↗

Optical emission spectroscopy of metal vapor dominated laser-arc hybrid welding plasma

During laser-arc hybrid welding, plasma properties affect the welding process and the weld quality. However, hybrid welding plasmas have not been systematically studied. Here we examine electron temperatures, species densities, and electrical conductivity for laser, arc, and laser-arc hybrid welding using optical emission spectroscopy. The effects of arc currents and heat source separation distances were examined because these parameters significantly affect weld quality. Time-average plasma electron temperatures, electron and ion densities, electrical conductivity, and arc stability decrease with increasing heat source separation distance during hybrid welding. Heat source separation distance affects these properties more significantly than the arc current within the range of currents considered. Improved arc stability and higher electrical conductivity of the hybrid welding plasma result from increased heat flux, electron temperatures, electron density, and metal vapor concentrations relative to arc or laser welding.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Use of Monocrystalline Silicon as Tool Material for Highly Accurate Blanking of Thin Metal Foils

The trend towards miniaturisation of metallic mass production components combined with increased component functionality is still unbroken. Manufacturing these components by forming and blanking offers economical and ecological advantages combined with the needed accuracy. The complexity of producing tools with geometries below 50 {mu}m by conventional manufacturing methods becomes disproportional higher. Expensive serial finishing operations are required to achieve an adequate surface roughness combined with accurate geometry details. A novel approach for producing such tools is the use of advanced etching technologies for monocrystalline silicon that are well-established in the microsystems technology. High-precision vertical geometries with a width down to 5 {mu}m are possible. The present study shows a novel concept using this potential for the blanking of thin copper foils with monocrystallline silicon as a tool material. A self-contained machine-tool with compact outer dimensions was designed to avoid tensile stresses in the brittle silicon punch by an accurate, careful alignment of the punch, die and metal foil. A microscopic analysis of the monocrystalline silicon punch shows appropriate properties regarding flank angle, edge geometry and surface quality for the blanking process. Using a monocrystalline silicon punch with a width of 70 {mu}m blanking experiments on as-rolled copper foils with a thickness of 20 {mu}m demonstrate the general applicability of this material for micro production processes.

36 MATERIALS SCIENCE↗

Microwave plasma based single step method for free standing graphene synthesis at atmospheric conditions

Microwave atmospheric pressure plasmas driven by surface waves were used to synthesize graphene sheets from vaporized ethanol molecules carried through argon plasma. In the plasma, ethanol decomposes creating carbon atoms that form nanostructures in the outlet plasma stream, where external cooling/heating was applied. It was found that the outlet gas stream temperature plays an important role in the nucleation processes and the structural quality of the produced nanostructures. The synthesis of few layers (from one to five) graphene has been confirmed by high-resolution transmission electron microscopy. Raman spectral studies were conducted to determine the ratio of the 2D to G peaks (>2). Disorder D-peak to G-peak intensity ratio decreases when outlet gas stream temperature decreases.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Polycrystalline indium phosphide on silicon by indium assisted growth in hydride vapor phase epitaxy

Polycrystalline InP was grown on Si(001) and Si(111) substrates by using indium (In) metal as a starting material in hydride vapor phase epitaxy (HVPE) reactor. In metal was deposited on silicon substrates by thermal evaporation technique. The deposited In resulted in islands of different size and was found to be polycrystalline in nature. Different growth experiments of growing InP were performed, and the growth mechanism was investigated. Atomic force microscopy and scanning electron microscopy for morphological investigation, Scanning Auger microscopy for surface and compositional analyses, powder X-ray diffraction for crystallinity, and micro photoluminescence for optical quality assessment were conducted. It is shown that the growth starts first by phosphidisation of the In islands to InP followed by subsequent selective deposition of InP in HVPE regardless of the Si substrate orientation. Polycrystalline InP of large grain size is achieved and the growth rate as high as 21 μm/h is obtained on both substrates. Sulfur doping of the polycrystalline InP was investigated by growing alternating layers of sulfur doped and unintentionally doped InP for equal interval of time. These layers could be delineated by stain etching showing that enough amount of sulfur can be incorporated. Grains of large lateral dimension up to 3 μm polycrystalline InP on Si with good morphological and optical quality is obtained. The process is generic and it can also be applied for the growth of other polycrystalline III–V semiconductor layers on low cost and flexible substrates for solar cell applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Temperature dependent transport characteristics of graphene/n-Si diodes

Realizing an optimal Schottky interface of graphene on Si is challenging, as the electrical transport strongly depends on the graphene quality and the fabrication processes. Such interfaces are of increasing research interest for integration in diverse electronic devices as they are thermally and chemically stable in all environments, unlike standard metal/semiconductor interfaces. We fabricate such interfaces with n-type Si at ambient conditions and find their electrical characteristics to be highly rectifying, with minimal reverse leakage current (<10{sup −10} A) and rectification of more than 10{sup 6}. We extract Schottky barrier height of 0.69 eV for the exfoliated graphene and 0.83 eV for the CVD graphene devices at room temperature. The temperature dependent electrical characteristics suggest the influence of inhomogeneities at the graphene/n-Si interface. A quantitative analysis of the inhomogeneity in Schottky barrier heights is presented using the potential fluctuation model proposed by Werner and Güttler.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

α-z-Rényi relative entropies

We consider a two-parameter family of Rényi relative entropies D{sub α,z}(ρ ∥ σ) that are quantum generalisations of the classical Rényi divergence D{sub α}(p ∥ q). This family includes many known relative entropies (or divergences) such as the quantum relative entropy, the recently defined quantum Rényi divergences, as well as the quantum Rényi relative entropies. All its members satisfy the quantum generalizations of Rényi’s axioms for a divergence. We consider the range of the parameters α, z for which the data-processing inequality holds. We also investigate a variety of limiting cases for the two parameters, obtaining explicit formulas for each one of them.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dynamics of metal-induced crystallization of ultrathin Ge films by rapid thermal annealing

Though Ge crystallization has been widely studied, few works investigate metal-induced crystallization of ultrathin Ge films. For 2 nm Ge films in oxide matrix, crystallization becomes challenging due to easy oxidation and low mobility of Ge atoms. Introducing metal atoms may alleviate these problems, but the functions and the behaviours of metal atoms need to be clarified. This paper investigates the crystallization dynamics of a multilayer structure 1.9 nm Ge/0.5 nm Al/1.5 nm Al{sub 2}O{sub 3} under rapid thermal annealing (RTA). The functions of metal atoms, like effective anti-oxidation, downshifting Raman peaks, and incapability to decrease crystallization temperature, are found and explained. The metal behaviours, such as inter-diffusion and defect generation, are supported with direct evidences, Al-Ge nanobicrystals, and Al cluster in Ge atoms. With these understandings, a two-step RTA process achieves high-quality 2 nm nanocrystal Ge films with Raman peak at 298 cm{sup −1} of FWHM 10.3 cm{sup −1} and atomic smooth interfaces.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Auger generation as an intrinsic limit to tunneling field-effect transistor performance

Many in the microelectronics field view tunneling field-effect transistors (TFETs) as society's best hope for achieving a >10× power reduction for electronic devices; however, despite a decade of considerable worldwide research, experimental TFET results have significantly underperformed simulations and conventional MOSFETs. To explain the discrepancy between TFET experiments and simulations, we investigate the parasitic leakage current due to Auger generation, an intrinsic mechanism that cannot be mitigated with improved material quality or better device processing. We expose the intrinsic link between the Auger and band-to-band tunneling rates, highlighting the difficulty of increasing one without the other. From this link, we show that Auger generation imposes a fundamental limit on ultimate TFET performance.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Acousto-optic laser projection systems for displaying TV information

This review addresses various approaches to television projection imaging on large screens using lasers. Results are presented of theoretical and experimental studies of an acousto-optic projection system operating on the principle of projecting an image of an entire amplitude-modulated television line in a single laser pulse. We consider characteristic features of image formation in such a system and the requirements for its individual components. Particular attention is paid to nonlinear distortions of the image signal, which show up most severely at low modulation signal frequencies. We discuss the feasibility of improving the process efficiency and image quality using acousto-optic modulators and pulsed lasers. Real-time projectors with pulsed line imaging can be used for controlling high-intensity laser radiation. (review)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

CaloScore v2: single-shot calorimeter shower simulation with diffusion models

Diffusion generative models are promising alternatives for fast surrogate models, producing high-fidelity physics simulations. However, the generation time often requires an expensive denoising process with hundreds of function evaluations, restricting the current applicability of these models in a realistic setting. In this work, we report updates on the CaloScorearchitecture, detailing the changes in the diffusion process, which produces higher quality samples, and the use of progressive distillation, resulting in a diffusion model capable of generating new samples with a single function evaluation. Here we demonstrate these improvements using the Calorimeter Simulation Challenge 2022 dataset.

47 OTHER INSTRUMENTATION↗

Effects of new leptons in electroweak precision data

We obtain limits on generic vectorlike leptons at the TeV scale from electroweak precision tests. These limits are complementary to the ones obtained from lepton flavor violating processes. In general, the quality of the global electroweak fit is comparable to the one for the standard model. In the case of an extra neutrino singlet mixing with the muon or electron, the global fit allows for a relatively large Higgs mass (M{sub H} < or approx. 260 GeV at 90% C.L.), thus relaxing the tension between the direct CERN LEP limit and the standard model fit.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optimizing Multi-Robot Placements for Wire Arc Additive Manufacturing

Wire arc additive manufacturing is a metal additive manufacturing process in which the material is deposited using arc welding technology. It is gaining popularity due to high material deposition rates and faster build time. It is en-abled using robotic manipulators and can build relatively large-scale parts faster when compared with other metal additive manufacturing processes. However, the size of the large-scale parts is limited by the size of the industrial manipulator being used for the process. This limitation is overcome by using a fixed configuration multi-robot cell in which manipulators work cooperatively to build large-scale parts quickly. A fixed multi-robot cell with closely spaced industrial manipulators has high flexibility, but it restricts the part size that can be built. If the manipulators are spread out, the cell loses its flexibility but can build relatively larger parts. This issue can be avoided by using larger size manipulators, which are expensive, or by moving the modest size manipulators based on the part geometries. This paper presents a novel algorithm to generate multi-robot placements for different part geometries to be built using wire arc additive manufacturing. Furthermore, the algorithm hierarchically optimizes the build time and the inverse kinematics consistency in robot paths to improve the process efficiency and part quality. We compare the results with fixed multi-robot cells and provide insights to users to make an informed decision on whether to use a fixed or a flexible multi-robot cell for wire arc additive manufacturing.

Bhatt, Prahar↗

Inverse determination of the penalty parameter in penalized weighted least-squares algorithm for noise reduction of low-dose CBCT

Purpose: A statistical projection restoration algorithm based on the penalized weighted least-squares (PWLS) criterion can substantially improve the image quality of low-dose CBCT images. The performance of PWLS is largely dependent on the choice of the penalty parameter. Previously, the penalty parameter was chosen empirically by trial and error. In this work, the authors developed an inverse technique to calculate the penalty parameter in PWLS for noise suppression of low-dose CBCT in image guided radiotherapy (IGRT). Methods: In IGRT, a daily CBCT is acquired for the same patient during a treatment course. In this work, the authors acquired the CBCT with a high-mAs protocol for the first session and then a lower mAs protocol for the subsequent sessions. The high-mAs projections served as the goal (ideal) toward, which the low-mAs projections were to be smoothed by minimizing the PWLS objective function. The penalty parameter was determined through an inverse calculation of the derivative of the objective function incorporating both the high and low-mAs projections. Then the parameter obtained can be used for PWLS to smooth the noise in low-dose projections. CBCT projections for a CatPhan 600 and an anthropomorphic head phantom, as well as for a brain patient, were used to evaluate the performance of the proposed technique. Results: The penalty parameter in PWLS was obtained for each CBCT projection using the proposed strategy. The noise in the low-dose CBCT images reconstructed from the smoothed projections was greatly suppressed. Image quality in PWLS-processed low-dose CBCT was comparable to its corresponding high-dose CBCT. Conclusions: A technique was proposed to estimate the penalty parameter for PWLS algorithm. It provides an objective and efficient way to obtain the penalty parameter for image restoration algorithms that require predefined smoothing parameters.

61 RADIATION PROTECTION AND DOSIMETRY↗

Temporal and spectral imaging with micro-CT

Purpose: Micro-CT is widely used for small animal imaging in preclinical studies of cardiopulmonary disease, but further development is needed to improve spatial resolution, temporal resolution, and material contrast. We present a technique for visualizing the changing distribution of iodine in the cardiac cycle with dual source micro-CT. Methods: The approach entails a retrospectively gated dual energy scan with optimized filters and voltages, and a series of computational operations to reconstruct the data. Projection interpolation and five-dimensional bilateral filtration (three spatial dimensions + time + energy) are used to reduce noise and artifacts associated with retrospective gating. We reconstruct separate volumes corresponding to different cardiac phases and apply a linear transformation to decompose these volumes into components representing concentrations of water and iodine. Since the resulting material images are still compromised by noise, we improve their quality in an iterative process that minimizes the discrepancy between the original acquired projections and the projections predicted by the reconstructed volumes. The values in the voxels of each of the reconstructed volumes represent the coefficients of linear combinations of basis functions over time and energy. We have implemented the reconstruction algorithm on a graphics processing unit (GPU) with CUDA. We tested the utility of the technique in simulations and applied the technique in an in vivo scan of a C57BL/6 mouse injected with blood pool contrast agent at a dose of 0.01 ml/g body weight. Postreconstruction, at each cardiac phase in the iodine images, we segmented the left ventricle and computed its volume. Using the maximum and minimum volumes in the left ventricle, we calculated the stroke volume, the ejection fraction, and the cardiac output. Results: Our proposed method produces five-dimensional volumetric images that distinguish different materials at different points in time, and can be used to segment regions containing iodinated blood and compute measures of cardiac function. Conclusions: We believe this combined spectral and temporal imaging technique will be useful for future studies of cardiopulmonary disease in small animals.

60 APPLIED LIFE SCIENCES↗

TH-E-19A-01: Quality and Safety in Radiation Therapy

Clinical radiotherapy data clearly demonstrate the link between the quality and safety of radiation treatments and the outcome for patients. The medical physicist plays an essential role in this process. To ensure the highest quality treatments, the medical physicist must understand and employ modern quality improvement techniques. This extends well beyond the duties traditionally associated with prescriptive QA measures. This session will review the current best practices for improving quality and safety in radiation therapy. General elements of quality management will be reviewed including: what makes a good quality management structure, the use of prospective risk analysis such as FMEA, and the use of incident learning. All of these practices are recommended in society-level documents and are incorporated into the new Practice Accreditation program developed by ASTRO. To be effective, however, these techniques must be practical in a resource-limited environment. This session will therefore focus on practical tools such as the newly-released radiation oncology incident learning system, RO-ILS, supported by AAPM and ASTRO. With these general constructs in mind, a case study will be presented of quality management in an SBRT service. An example FMEA risk assessment will be presented along with incident learning examples including root cause analysis. As the physicist's role as “quality officer” continues to evolve it will be essential to understand and employ the most effective techniques for quality improvement. This session will provide a concrete overview of the fundamentals in quality and safety. Learning Objectives: Recognize the essential elements of a good quality management system in radiotherapy. Understand the value of incident learning and the AAPM/ASTRO ROILS incident learning system. Appreciate failure mode and effects analysis as a risk assessment tool and its use in resource-limited environments. Understand the fundamental principles of good error proofing that extends beyond traditional prescriptive QA measures.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗