Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,279 records · Page 71

Precision DIS thrust predictions for HERA and EIC

We present predictions for the DIS 1-jettiness event shape $τ^b_1$, or DIS thrust, using the framework of Soft Collinear Effective Theory (SCET) for factorization, resummation of large logarithms, and rigorous treatment of nonperturbative power corrections, matched to fixed-order QCD away from the resummation region. Our predictions reach next-to-next-to-next-to-leading-logarithmic (N 3 LL) accuracy in resummed perturbation theory, matched to $\mathcal{O}(α^2_s)$ fixed-order QCD calculations obtained using the program NLOJet++. We include a rigorous treatment of hadronization corrections, which are universal across different event shapes and kinematic variables x and Q at leading power, and supplement them with a systematic scheme to remove $\mathcal{O}$(Λ QCD ) renormalon ambiguities in their definition. The framework of SCET allows us to connect smoothly the nonperturbative, resummation, and fixed-order regions, whose relative importance varies with x and Q, and to rigorously estimate theoretical uncertainties, across a broad range of x and Q covering existing experimental results from HERA as well as expected new measurements from the upcoming Electron- Ion-Collider (EIC). Our predictions will serve as an important benchmark for the EIC program, enabling the precise determination of the QCD strong coupling α s and the universal nonperturbative first moment parameter Ω 1 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precise measurements of branching fractions for $ {\mathrm{D}}_{\mathrm{s}}^{+} $ meson decays to two pseudoscalar mesons

We measure the branching fractions for seven $D$$^{+}_{s}$ two-body decays to pseudo-scalar mesons, by analyzing data collected at √s = 4.178 ~ 4.226 GeV with the BESIII detector at the BEPCII collider. The branching fractions are determined to be $$ {\displaystyle \begin{array}{c}\mathcal{B}\left({D}_s^{+}\to {K}^{+}\eta \hbox{'}\right)=\left(2.68\pm 0.17\pm 0.17\pm 0.08\right)\times {10}^{-3},\\ {}\mathcal{B}\left({D}_s^{+}\to \eta \hbox{'}{\pi}^{+}\right)=\left(37.8\pm 0.4\pm 2.1\pm 1.2\right)\times {10}^{-3},\\ {}\mathcal{B}\left({D}_s^{+}\to {K}^{+}\eta \right)=\left(1.62\pm 0.10\pm 0.03\pm 0.05\right)\times {10}^{-3},\\ {}\mathcal{B}\left({D}_s^{+}\to \eta {\pi}^{+}\right)=\left(17.41\pm 0.18\pm 0.27\pm 0.54\right)\times {10}^{-3},\\ {}\mathcal{B}\left({D}_s^{+}\to {K}^{+}{K}_S^0\right)=\left(15.02\pm 0.10\pm 0.27\pm 0.47\right)\times {10}^{-3},\\ {}\mathcal{B}\left({D}_s^{+}\to {K}_S^0{\pi}^{+}\right)=\left(1.109\pm 0.034\pm 0.023\pm 0.035\right)\times {10}^{-3},\\ {}\mathcal{B}\left({D}_s^{+}\to {K}^{+}{\pi}^0\right)=\left(0.748\pm 0.049\pm 0.018\pm 0.035\right)\times {10}^{-3},\end{array}} $$ B D s + → K + η ' = 2.68 ± 0.17 ± 0.17 ± 0.08 × 10 - 3 , B D s + → η ' π + = 37.8 ± 0.4 ± 2.1 ± 1.2 × 10 - 3 , B D s + → K + η = 1.62 ± 0.10 ± 0.03 ± 0.05 × 10 - 3 , B D s + → η π + = 17.41 ± 0.18 ± 0.27 ± 0.54 × 10 - 3 , B D s + → K + K S 0 = 15.02 ± 0.10 ± 0.27 ± 0.47 × 10 - 3 , B D s + → K S 0 π + = 1.109 ± 0.034 ± 0.023 ± 0.035 × 10 - 3 , B D s + → K + π 0 = 0.748 ± 0.049 ± 0.018 ± 0.035 × 10 - 3 , where the first uncertainties are statistical, the second are systematic, and the third are from external input branching fraction of the normalization mode $ {D}_s^{+} $ D s + → K + K - π + . Precision of our measurements is significantly improved compared with that of the current world average values.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Precision direct photon spectra at high energy and comparison to the 8 TeV ATLAS data

The direct photon spectrum is computed to the highest currently available precision and compared to ATLAS data from 8 TeV collisions at the LHC. The prediction includes threshold resummation at next-to-next-to-next-to-leading logarithmic order through the program PeTeR, matched to next-to-leading fixed order with fragmentation effects using JetPhox and includes the resummation of leading-logarithmic electroweak Sudakov effects. Remarkably, improved agreement with data can be seen when each component of the calculation is added successively. This comparison demonstrates the importance of both threshold logs and electroweak Sudakov effects. Numerical values for the predictions are included.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision e + e − hemisphere masses in the dijet region with power corrections

We derive high-precision results for the e + e − heavy jet mass (HJM) dσ/dρ and dihemisphere mass (DHM) d 2 σ/(ds 1 ds 2 ) distributions, for s 1 ~ s 2 , in the dijet region. New results include: i) the N 3 LL resummation for HJM of large logarithms ln n (ρ) at small ρ including the exact two-loop non-global hemisphere soft function, the 4-loop cusp anomalous dimension and the 3-loop hard and jet functions, ii) N 3 LL results for DHM with resummation of logarithms ln(s 1,2 /Q 2 ) when there is no large separation between s 1 and s 2 , iii) profile functions for HJM to give results simultaneously valid in the peak and tail regions, iv) a complete two-dimensional basis of non-perturbative functions which can be used for double differential observables, that are needed for both HJM and DHM in the peak region, and v) an implementation of renormalon subtractions for large-angle soft radiation to $\mathcal{O}$ (α$^{3}_{s}$) together with a resummation of the additional large ln(Qρ/Λ QCD ) logarithms. Here Q is the e + e − center-of-mass energy. Our resummation results are combined with known fixed-order $\mathcal{O}$ (α$^{3}_{s}$) results and we discuss the convergence and remaining perturbative uncertainty in the cross section. We also prove that, at order 1/Q, the first moment of the HJM distribution involves an additional non-perturbative parameter compared to the power correction that shifts the tail of the spectrum (where 1 ≫ ρ ≫ Λ QCD /Q). This differs from thrust where a single non-perturbative parameter at order 1/Q describes both the first moment and the tail, and it disfavors models of power corrections employing a single non-perturbative parameter, such as the low-scale effective coupling model. In this paper we focus only on the dijet region, not the far-tail distribution for ρ ≳ 0.2 beyond which the trijet factorization and resummation become important.

Factorization↗

Probing extended scalar sectors with precision e + e - → Zh and Higgs diphoton studies

We compute the one-loop corrections to σ(e + e - → Zh) arising from representative extended Standard Model scalar sector scenarios. According to the new scalar SU(2)L representations, we consider the inert doublet, real and complex triplet, quintuplet, and septuplet models. With the sub-percent level precision expected for prospective future e + e - collider measurements of σ(e + e - → Zh), studies of the Higgsstrahlung process will probe extended scalar sector particle spectrum and interactions in a manner complementary to direct searches at the Large Hadron Collider and possible future pp colliders. We also compare with the sensitivity of future Higgs diphoton decay rate measurements. We find that the σ(e + e - → Zh) and Γ(h → γγ) complementarity is particularly pronounced for the complex triplet model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Observation of muonic Dalitz decays of chib mesons and precise spectroscopy of hidden-beauty states

The decays of the χb1 (1P), χb2 (1P), χb1 (2P) and χb2 (2P) mesons into the Υ(1S)μ + μ − final state are observed with a high significance using proton-proton collision data collected with the LHCb detector and corresponding to an integrated luminosity of 9 fb −1 . The newly observed decays together with the Υ(2S) → Υ(1S)π + π − and Υ(3S) → Υ(2S)π+π− decay modes are used for precision measurements of the mass and mass splittings for the hidden-beauty states.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision Measurement of μG p E /G p m at Low Q 2

Precision measurements are presented of the proton electric to magnetic form-factors ratios at Q 2 = 0.3 - 0.8 (GeV/c)2, obtained by polarization-transfer in Hall A of the Jefferson Laboratory. The measured ratios are significantly lower than published values. New global fits to the individual form factors indicate a lower electric form factor and a slightly higher magnetic form factor. The proton charge radius extracted from the new results is somewhat smaller but consistent with previous values obtained from electron–proton scattering, and is in significant disagreement with the recent value obtained from muonic hydrogen. The effects of the new results on other quantities are briefly discussed.

08 HYDROGEN↗

The Qweak: Precision measurement of the proton's weak charge by parity violating experiment

The Qweak experiment at the Thomas Jefferson National Accelerator Facility measures the parity violating asymmetry in longitudinally polarized electron scattering from the proton at very low momentum transfer, Q{sup 2} = 0.026 (GeV/c){sup 2}, at an incident electron beam energy of 1.16 GeV. With this measurement and the earlier results of the parity violating elastic scattering experiments, the Qweak experiment determines the weak charge of the proton with a 4% combined statistical and systematic error. This measurement will be used to determine the weak mixing angle that is predicted by the Standard Model from the Z{sup 0} pole down to lower energies. Qweak will determine to a 0.3% relative precision, providing a competitive measurement of the running of this quantity. Moreover, if there is a significant deviation of the weak mixing angle from the Standard Model prediction, then the Qweak experiment will give a glimpse of possible extensions of the Standard Model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nuclear Forces for Precision Nuclear Physics: A Collection of Perspectives

This is a collection of perspective pieces contributed by the participants of the Institute for Nuclear Theory’s Program on Nuclear Physics for Precision Nuclear Physics which was held virtually from April 19 to May 7, 2021. The collection represents the reflections of a vibrant and engaged community of researchers on the status of theoretical research in low-energy nuclear physics, the challenges ahead, and new ideas and strategies to make progress in nuclear structure and reaction physics, effective field theory, lattice QCD, quantum information, and quantum computing. Please note the contributed pieces solely reflect the perspectives of the respective authors and do not represent the viewpoints of the Institute for Nuclear theory or the organizers of the program.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radar Remote Method of High-Precision Monitoring of the Geodetic Alignment and Natural Oscillations of Dams

The article examines problems of real-time remote monitoring of the geometric form of the upper alignment and natural frequencies of oscillations of a dam using a radiogeodetic method with accuracy to ± 1 mm from a distance up to 1000 m. At the foundation of the method is the use of active radar and miniature switched re-radiators in the form of slot antennas located in a linear row along the top edge of a dam. By contrast with the method of telemetry that uses high-precision optical devices — tachometers, levelers, etc. — the radiogeodetic method can be executed in real time with minimum effect from weather conditions.

42 ENGINEERING↗

Precision Compton polarimetry for the QWeak experiment at Jefferson Lab

The Q Weak experiment, scheduled to run in 2010-2012 in Hall C at Jefferson Lab, will measure the parity-violating asymmetry in elastic electron-proton scattering at 1.1 GeV to determine the weak charge of the proton, Q{sub Weak}{sup p} = 1 - 4 sin{sup 2} {theta}{sub W}. The dominant experimental systematic uncertainty will be the knowledge of the electron beam polarization. With a new Compton polarimeter we aim to measure the beam polarization with a statistical precision of 1% in one hour and a systematic uncertainty of 1%. A low-gain Fabry-Perot cavity laser system provides the circularly polarized photons. The scattered electrons are detected in radiation-hard diamond strip detectors, and form the basis for a coincidence trigger using distributed logic boards. The photon detector uses a fast, undoped CsI crystal with simultaneous sampling and integrating read-out. Coincident events are used to cross-calibrate the photon and electron detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision mass measurements of 44 V and 44m V for nucleon-nucleon interaction studies

Here, we discuss the motivation and technique of Penning trap mass spectrometry applied to radioactive 44 V and 44m V, using the LEBIT 9.4 T Penning trap mass spectrometer at the National Superconducting Cyclotron Laboratory (NSCL) at Michigan State University. A complementary measurement of these nuclides, performed at the CSRe in Lanzhou, China, was recently published, but with errors several times larger than obtainable for a short-lived radionuclide in a Penning trap. Interpretation of the higher precision results is ongoing and a full accounting of this measurement is anticipated in the coming months.

44-vanadium↗

Superconducting Tunnel Junctions for High-Precision EUV Spectroscopy

We have characterized the photon response of superconducting tunnel junctions in the extreme ultraviolet energy range below 100 eV with a pulsed 355 nm laser. The detectors are operated at rates up to 5000 counts/s, are very linear in energy and have an energy resolution between 0.9 and 2 eV. Here, we observe multiple peaks that correspond to an integer number of photons with a Poissonian probability distribution and that can be used for high-accuracy energy calibration. The uncertainty of the centroid depends on the detector resolution and the counting statistics and can be as low as 1 meV for well-separated peaks with > 10 5 counts. We discuss the precision of the peak centroid as a function of detector resolution and total number of counts and the accuracy of the energy calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polyatomic interferences on high precision uranium isotope ratio measurements by MC-ICP-MS: Applications to environmental sampling for nuclear safeguards

Modern mass spectrometry and separation techniques have made measurement of major uranium isotope ratios a routine task; however accurate and precise measurement of the minor uranium isotopes remains a challenge as sample size decreases. One particular challenge is the presence of isobaric interferences and their impact on the accuracy of minor isotope 234 U and 236 U measurements. Furthermore, we present techniques used for routine U isotopic analysis of environmental nuclear safeguards samples and evaluate polyatomic interferences that negatively impact accuracy as well as methods to mitigate their impacts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A multiple ion counter total evaporation (MICTE) method for precise analysis of plutonium by thermal ionization mass spectrometry

This study presents a total evaporation method for the analysis of sub-picogram quantities of Pu, utilizing an array of multiple ion counters. Data from three standards are presented to assess the utility of the technique. An external precision of 1.5% RSD (2σ) was achieved on aliquots approaching 100 fg for the minor 240 Pu isotope. Accurate analysis of <1 femtogram of 240 Pu, is achievable, with an external reproducibility of better than 10% RSD (2σ). Finally, this new technique represents a significant advance in the total evaporation method and will allow routine measurement of femtogram sized Pu samples by thermal ionization mass spectrometry.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

The Most Reliable and Precise Model to Determine Schottky Barrier Height and Photoelectron Yield Spectroscopy

Schottky barrier height (SBH), φ, plays a crucial role in the design of electronic and photo-electronic devices. In order to reckon SBH via internal photoemission (IPE), the technique is through extrapolating square root of IPE yield-and cube root of IPE yield-photon energy plots to zero before this work, this work was motivated by the most reliable and precise model to determine the SBH via IPE. A phenomenological model for connection IPE quantum yield and photon energy has been successfully established based on Fermi–Dirac distribution. The results of experimental observations fitted via the model indicate that the modeled quantum yield agrees well with experimental data. This model emphasizes the threshold of photon energy for calculating SBH, and the SBH of InN/GaN, p-type GaP/p-type Si, Pt/GaP, Au/GaAs, Si/SiO{sub 2} and Cu/SiO{sub 2} were obtained with high reliability after the method had been applied.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improved Precision and Accuracy of Quantification of Rare Earth Element Abundances via Medium-Resolution LA-ICP-MS

Laser ablation ICP-MS enables streamlined, high-sensitivity measurements of rare earth element (REE) abundances in geological materials. However, many REE isotope mass stations are plagued by isobaric interferences, particularly from diatomic oxides and argides. In this study, we compare REE abundances quantitated from mass spectra collected with low-resolution (m/Δm = 300 at 5% peak height) and medium-resolution (m/Δm = 2500) mass discrimination. A wide array of geological samples was analyzed, including USGS and NIST glasses ranging from mafic to felsic in composition, with NIST 610 employed as the bracketing calibrating reference material. The medium-resolution REE analyses are shown to be significantly more accurate and precise (at the 95% confidence level) than low-resolution analyses, particularly in samples characterized by low (<μg/g levels) REE abundances. A list of preferred mass stations that are least susceptible to isobaric interferences is reported. These findings impact the reliability of REE abundances derived from LA-ICP-MS methods, particularly those relying on mass analyzers that do not offer tuneable mass-resolution and/or collision cell technologies that can reduce oxide and/or argide formation. .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

3D Reconstruction of a High-Energy Diffraction Microscopy Sample Using Multi-modal Serial Sectioning with High-Precision EBSD and Surface Profilometry

High-energy diffraction microscopy (HEDM) combined with in situ mechanical testing is a powerful nondestructive technique for tracking the evolving microstructure within polycrystalline materials during deformation. This technique relies on a sophisticated analysis of X-ray diffraction patterns to produce a three-dimensional reconstruction of grains and other microstructural features within the interrogated volume. However, it is known that HEDM can fail to identify certain microstructural features, particularly smaller grains or twinned regions. Characterization of the identical sample volume using high-resolution surface-specific techniques, particularly electron backscatter diffraction (EBSD), can not only provide additional microstructure information about the interrogated volume but also highlight opportunities for improvement of the HEDM reconstruction algorithms. In this study, a sample fabricated from undeformed “low solvus, high refractory” nickel-based superalloy was scanned using HEDM. The volume interrogated by HEDM was then carefully characterized using a combination of surface-specific techniques, including epi-illumination optical microscopy, zero-tilt secondary and backscattered electron imaging, scanning white light interferometry, and high-precision EBSD. Custom data fusion protocols were developed to integrate and align the microstructure maps captured by these surface-specific techniques and HEDM. The raw and processed data from HEDM and serial sectioning have been made available via the Materials Data Facility (MDF) at https://doi.org/10.18126/4y0p-v604 for further investigation.

36 MATERIALS SCIENCE↗